Standards Affecting a Premise T-1 Installation



Similar documents
Communication, Signal & Data Cables

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

Network Engineers Everywhere:

Position Cat5e (EMT) Modular Plug Connectors. Application Specification

400 Series - Mini USB Buccaneer

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

Serial Data Grade Cables

ULTIMATE SNAP-N-SEAL

Directory chapter 04

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

Broadcast and Commercial AV Cabling MASTER CATALOG

Specification SFTP CAT6 Network Cable 23AWG CU

ETHERLINE Ethernet Cable, Connectors & Tools

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

West Penn Wire. Access Control Systems and Cables WEST PENN WIRE CABLE WITH CONFIDENCE

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

Installation & Weatherproofing Guide for ENCOM Broadband Radios

Standard Buccaneer - Ethernet

Outside Telephone Cable

" EXCEEDING EXPECTATIONS WITH PERFORMANCE "

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

Terminating 25-Pair Cable and 4-Pair Cross Connects

AMPSEAL* Automotive Plug Connector and Header Assembly

ENGINEERING COMMITTEE

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Sound, Alarm & Security Cable 7

Accelerating Light. Copper Cabling Solutions. Category 6A

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Standard Buccaneer - USB

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

T-Extender E-Extender

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

6000 Series Buccaneer

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Security & Control Cables

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

PCb Cable mount twinax. ConneCtorS

COAXICON Contacts. RF Coax Connectors. Product Facts

MICROCABLES. A complete vision of your connectivity needs. Catalogue

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

MYTHBUSTING Takes on Shielded Cabling

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

LocoNet, the Digitrax Difference

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

Generator DoCKInG StatIonS

Ethernet Cat 5e & Cat 6 Patch Panels

Outside Plant DS3 Deployment Connectivity Hardware TROMPETER

Analog Multi-Pair Snake Cable High-Flex and NEC Rated Cables

Microphone and Musical Instrument Cable Overview

Times Microwave Systems Hermetically Sealed Assemblies

Gulf Cable & Electrical Ind. Co.

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Network Cabling Guide

RF & Microwave cable assemblies C291

Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof

Why FOUNDATION Fieldbus?

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

LOW LOSS CABLE PAG. 1

KNOW YOUR OPTIONS: 230 KV POWER CABLES

EH-20 20m antenna. By VE3RGW

CIN::APSE MICROMINIATURE D-SUB

EMC Test Chamber Solutions RF Cable Assemblies and Connectors

Cables and Accessories Selection Guide

Testing, Repairing & Installing Home Telephone Wiring Disclaimer

Cat7/Class F New Installation Concept New infrastructure. Handbook

Cable Specifications. T3 Trunk Cabling APPENDIX

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

LS Data Communication Product

Section kv Power Cables

Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house

75 Ω Transmission System

Sunridge MCB Series Miniature Coaxial Interconnect, 2.5mm or 2.0mm Mated Height

Universal MATE-N-LOK Connectors

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

UTP Video Cables. Pair 2 - Category 5E Type 100Ω. The first pair is used for video transmission.

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

E Series. E Series. Category 6 and 5e. Features

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

CAVEL VS80205 MADE IN ITALY 1000 V

CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections

Ethernet Patch Cord Wiring

INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION.

Transcription:

Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity within their central offices. By the late 80 s it became apparent that the demand from subscribers for bandwidth greater than 56K was becoming a reality. The extension of the T-carrier system into the subscriber network was a natural. The technology having already been developed, the migration to the premise was about to evolve. As T-1 signaling began to migrate outward from the central office, it became evident that standards would be required to help maintain the integrity of the T-carrier system. ANSI accepted the chore and by the late 80 s a number of ANSI T1 standards had been developed and published. From the installer s perspective, two of these standards hold particular relevance. *ANSI T1.403 Carrier-to-Customer Installation - DS1 Metallic Interface *ANSI T1.102 for Telecommunications Digital Hierarchy Electrical Interfaces The content of T1.102 is primarily aimed at the signal delivered from the T-carrier to the customer interface (premise demarc). The content of T1.403 is aimed primarily at the signal and the physical layer to and from the demarc and the CPE (customer premise equipment). More specifically, only to and from the very first piece of CPE. This may be a CSU, DSU, IAD, or router. T1.403 specifically states that all wiring beyond that point (inward to the remaining CPE) should be as specified by the equipment manufacturer. In choosing the proper cable to extend the T-line (demarc extension cable) these coordinated documents call out specific physical and electrical requirements which must be met in the installation. These are summarized as follows: *Balanced pairs, 22 AWG, 100 Ohm impedance. *T-carrier to complete the demarc in RJ48 jack configurations. *T extension to be pinned in plugs configured in RJ48 C or X. (See below for plug pin-out.) Certain D.B. connectors are authorized but rarely used. *Loss budget (attenuation) allotted for this cable section should be 5.5 db. This value translates to about 1,000 feet of properly designed cable without the need for repeaters. This distance will often eliminate the need for costly demarc relocations.

Pin-Outs Terminating in an 8-pin modular plug is specified in ANSI T1.403. USOC RJ48 pinning is required. Step 1 Using a safety razor blade, utility knife, or similar tool, ring the plastic outer sheath approximately 1-1/2 inches from the end. Remove the 1-1/2 inch slug from the construction. The two individually shielded pairs are now exposed. (Note: If the blade modestly nicked the tape and even the insulation, continue anyway. These will be removed in future steps.) Step 2 Remove all tapes flush with the jacket line. (Tip: A simple nick at the lip of each tape will permit easy tearing around the film. This is a very simple process.) You should now have a white x orange pair and a white x blue pair exposed. Step 3 The insulation system of this construction is made up of a dual layered composite. Removing the outer layer (foam) will leave the inner insulation behind. Remove the outer insulation of all four leads leaving the inner insulation adhered to the copper wire. The trick is to cut the outer layer without injuring the inner layer. Inexpensive insulation strippers are best suited for this step. Preferably the design will permit a depth setting to be adjusted and locked with the tool. If the setting is by AWG, start with 18 AWG as the setting. If the tool uses a non-indexed setting, a trial and error approach may be necessary. In either event, the removal process must be performed using a pull direction in a straight line with the cable s construction. If the pull direction is at an angle, the inner insulation is at risk.

Step 4 Quabbin Wire & Cable suggests the use of modular plugs that include a load bar (however there are plugs without a load bar that are popular connectors). This type of plug GREATLY reduces termination time, frustration, and errors. The two drains may be twisted together and inserted through the same position. The load bar accommodates quick, precise arrangement of leads and drains prior to insertion into the plug cavity. The pin out (color code arrangement) for USOC connector RJ48C is as shown in the load bar figure. The jack at the demarc expects to see this arrangement. Step 5 Slide the loaded load bar toward and flush with the jacket. Measuring from the jacket s edge, cut the extended leads and drains straight across and evenly leaving 5/8 inch. Step 6 Slip the load bar outward toward the end of the cut leads. Stop the load bar just short of the immediate end. (Note: The purpose of the load bar is to aim the leads so that they enter the plug cavity precisely positioned to pass through to the correct pin positions.)

Step 7 With the plug s release trigger positioned downward, and the orange conductor positioned leftmost, press the cable with load bar into the plug cavity causing the leads to now extend to the far end of the plug nose. When correctly positioned: 1. The conductors should extend to the end of the plug 2. The load bar should be firmly seated so as to resist further movement in either direction 3. The outer jacket should enter the plug cavity about 1/4 inch Step 8 Using a mod plug crimping tool containing an 8-pin compression die, press the assembled cable and modular connector into the die. Manually complete the mating of the cable and plug by compressing the handles through a complete cycle. The pins should now have continuity with the conductors and the jacket should now be held in place by an included strain relief. Remove the assembly from the crimping tool. This terminated end is ready for installation at the demarc point. Quabbin s Solution Quabbin Wire & Cable has designed part number 9720 to carry this signal. It is a true T-1 demarc extension cable. Cable specification information is shown below. Ask your preferred distributor for it by name and part number.

PN 9720 1) CONSTRUCTION: NOM. DIA. CONDUCTOR: 22 AWG SOLID TINNED COPPER.025" INSULATION: TWO LAYER COMPOSITE POLYOLEFIN.020 WALL THICKNESS.065" PAIRS: COLOR CODED SINGLES TWISTED WITH FILLERS INTO PAIRS WRAPPED WTH AN ALUMINUM POLYESTER FOIL SHIELD (FOIL OUT) 100% COVERAGE PER PAIR. 24 AWG SOLID TINNED COPPER DRAIN EACH PAIR..133" ISOLATOR: EACH PAIR SHALL BE ELECTRICALLY ISOLATED FROM EACH OTHER WITH A POLYESTER TAPE WRAP.136 CABLE: (2) SHIELDED PAIRS PULLED IN STRAIGHT.136" X.272" JACKET: POLYVINYLCHLORIDE, BEIGE,.022" NOM. WALL THICKNESS.178" X.315" 2) PHYSICAL PROPERTIES: TEMPERATURE RATING, MAX. 60 C WT./M', NOM., NET. 35.12 LBS. 3) ELECTRICAL CHARACTERISTICS: CAPACITANCE, MUTUAL DIELECTRIC WITHSTANDING, MIN VOLTAGE RATING, MAX. NEXT, TYPICAL D.C. RESISTANCE, MAX. PER ASTM B258 IMPEDANCE, CHARACTERISTIC, NOM RETURN LOSS, TYPICAL ATTENUATION: 15 PF/FT. AT 1 MHZ 1500V RMS 300V GREATER THAN 60 DB; 500KHZ TO 3.5 MHZ 16.6 OHMS/M' 100.0 OHMS FROM 500 KHZ TO 3.5 MHZ (+/- 10 OHMS AT.772 MHZ AND AT 1.544 MHZ) GREATER THAN 30DB; 500 KHZ TO 3.5 MHZ 4) AGENCY APPROVALS: NEC (UL) TYPE CMR CEC C(UL) TYPE CMR 5) APPLICATION: T1: LEVELS 1,1A AND 1C INTERCONNECTION COMPLIES WITH ANSI T1.403 CARRIER-TO-CUSTOMER INSTALLATION - DS1 METALLIC INTERFACE AT A MAXIMUM LENGTH OF 200M (655FT). RoHS COMPLIANT MATERIALS. NOTE: THIS CONSTRUCTION IS UNIQUELY DESIGNED TO FIT MOST POPULAR RJ-45 CONNECTORS WHEN THE OUTER PRIMARY INSULATION IS REMOVED. 6) PRINT: QUABBIN DATAMAX 100 OHM T1 (DS1) CABLE P/N 9720R -- TYPE CMR (UL) C(UL) 22 AWG SHIELDED

RoHS -- (LOT DESIGNATOR) (SEQUENTIAL FOOTAGE) 7) COLOR CODE: 1. ORANGE X WHITE/ORANGE 2. BLUE X WHITE/BLUE 8) PACKAGING: TO BE PACKAGED AS PER QWC'S STANDARD PACKAGING It is important that the termination be performed using the manufacturer s recommended crimping tools, procedures, and hardware. The following connectors are suggested. Contact the manufacturer for availability and details. Suggested Plug Manufacturer Connector Part Numbers Sentinel Connector Systems* 110-080820-24 (717.843.4240) Stewart Connector Systems (717.235.7512) 940SP3088OB Tyco Electronics (AMP) 5-558530-3 00 (800.468.2023) *This particular connector system does NOT include a load bar; it is however a popular proven connector.