Dyn-Loc IV Quick Start Guide (For Eddy-Current Dynamometers)

Similar documents
INSTALLATION & SERVICE MANUAL. Display Panel

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

Applied Electronics. Commercial Dimming System UPDATE NOTICE

ABB Drives. User s Manual HTL Encoder Interface FEN-31

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

SYSTEM 4C. C R H Electronics Design

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Contents. Document information

Model SRMD Setra Remote Monitoring Display

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

Analog Servo Drive 25A8

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

VX 2400 Dimmer User's Manual

Research RF Sputtering Packages

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual.

Advantium 2 Plus Alarm

Controller Automation, Model II+

INSTALLATION INSTRUCTIONS

PUSH BUTTON START INSTALLATION MANUAL

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

FAQ s on Siemens Magmeters

GLOLAB Two Wire Stepper Motor Positioner

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

LocoNet, the Digitrax Difference

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

8 Channel Status Input Panel model SIP-8

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Fan Coil EC Motor Control

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

A1000 Cheat Sheet (Open Loop Vector)

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual

Brio-Rmanual:Cursamanual.qxd 08/04/ :25 Page1

VLT 6000 HVAC. Contents

Electronic Power Control

Allen-Bradley/Rockwell

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

Servo Info and Centering

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Troubleshooting and Diagnostics

T7560A,B,C Digital Wall Module

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

Operating instructions

CX Zoner Installation & User Guide

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Experiment 5. Strain Gage Measurements

Mobile Device Power Monitor Battery Connection Quick Start Guide

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Operation and Installation Manual

MDC Series

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Model SETR-50 and SETR-51 Trim Tab Control

HP UPS R1500 Generation 3

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

understanding medium frequency induction melting furnace and its components

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

SYSTEM 45. C R H Electronics Design

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

INSTALLER S INSTRUCTIONS FOR TRI-METRIC Battery system monitor, Models TM-2030-RV and TM-2030-A. Contents

Duct Humidity Transmitter

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

GPD 506/P5 Start-up Procedure and Checklist

Electronically Controlled Air Suspension (ECAS) for Trucks

Instruction Manual. This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E E 50-20E E

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Talon and Talon SR User Manual

Multi-Protocol decoder with Load regulation

SELECTION, APPLICATION AND MAINTENANCE

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

TSn SERIES Surge Protective Device

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

HM-W536 Install Guide

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Addendum to the Operating Instructions

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Transcription:

(For Eddy-Current Dynamometers) This Quick Start Guide helps to get the Dyn-Loc IV dynamometer controller configured and running quickly. Other Quick Start Guides are available for specific AC dynamometer/drive combinations. While this Guide helps to get started quickly, it is not a substitute for The Dyn-Loc IV User Manual. Refer to the manual for details not specifically covered in this guide. The manual can be found on our web site: www.dynesystems.com NOTE: This quick Start Guide applies to units with serial number greater than 748 only. Assure that the following required material is on hand before beginning: Dyn-Loc IV User Manual Various types of multi-conductor shielded cable for transducer connections (see table at the end of this document) Mating MS Series connectors, (see table at the end of this document) Use of this guide requires that the dynamometer be connected to a Device Under Test (DUT). The DUT must be capable of rotating under the control of a speed control or throttle position control. NOTE: If the DUT is not operational, energizing the eddy-current dynamometer is NOT recommended. The DUT must be fully operational to carry out the Quick Start Guides process in its entirety. However, connecting and testing of the speed and torque transducers may be carried out without a functional DUT, reference sections 3 and 4 of this quick start guide. This guide outlines steps needed to bring the Dyn-Loc IV to operational status as quickly as possible. Execute these steps exactly in the order presented: 1. Safety Review 2. Dyn-Loc IV Power Connections 3. Speed Transducer Connection & Configuration 4. Torque Transducer Connection & Configuration 5. Dyn-Loc IV Eddy-Current Power Amplifier Connections 6. Water Safeties Interlock 7. Field Current Adjustments 8. Enabling the DUT 9. Enabling the Dyn-Loc IV Controller Controls, Dynamometers, System Integration and Test Cell Automation Dyne Systems, Inc. W209 N17391 Industrial Drive Jackson, Wisconsin 53037 phone: 800.657.0726 website:www.dynesystems.com V1.0 1

1 SAFETY REVIEW Installing and operating this equipment involves hazards relating to rotating equipment and dangerous electrical voltages. To avoid the possibility of serious or fatal injury, only qualified persons familiar with industrial electrical power systems should install power wiring. Review all safety considerations in the manual before executing any steps in this guide or making any adjustments to the Dyn- Loc IV. It is recommended that a licensed electrician perform all power connections exceeding 50 Volts. 2 DYN-LOC IV POWER CONNECTIONS Follow the below steps to connect and supply power to the Dyn-Loc IV: 1. Ensure all incoming power is de-energized prior to proceeding. 2. Place the Dyn-Loc IV controller in a rack or on a suitable surface. NOTE: The Dyn-Loc IV is a rack mountable unit. Rack mounting is recommended due to exposed connections on the Dyn-Loc IV barrier strip. 3. Connect the control transformer secondary (typically 120 VAC) power wires to terminals L3 and L4 on the barrier strip found on the back of the controller. NOTE: If the control transformer secondary supplies 230 VAC to L3 and L4 then the 115V/230V switch inside the Dyn-Loc IV must be set for 230VAC. This switch is located in the back left corner of the bottom circuit board. 4. Connect the field transformer secondary (typically 240 VAC, 277VAC maximum) power wires to terminals L1 and L2 on the barrier strip found on the back of the controller. NOTE: Incoming power to both the control and field transformer primary windings must be fed from the same phase pair. Damage may result from improper phasing. 5. Energize both the control and field transformers. The RPM, MASTER, EM STOP RESET push buttons, digital LED display, and ACTIVE button on the front of the controller will illuminate. 6. De-energize both the control and field transformers. 7. If the push buttons and digital LED display illuminate as expected, proceed to the next step. If not, reference the Dyn-Loc IV user manual or contact Dyne Systems before proceeding. 2 V1.0

3 SPEED TRANSDUCER CONNECTION & CONFIGURATION Refer to the manual (Chapter 8, Section 3) for details on wiring and (Chapter 4, Sections 3 and 4 and Chapter 5, Section 11.4) for configuring a speed transducer. All speed transducers are terminated at the RPM F.B. connector located on the back of the Dyn-Loc IV. A mating 7-pin MS connector is required and can be constructed using items 9, and 10 listed in the Connector Components table at the end of this guide. Follow these steps in the order presented: 1. Ensure all incoming power is de-energized prior to proceeding. 2. Determine the type of speed transducer to be used. Two types of speed transducers are supported: Magnetic Pickup Units (MAGPU s); and Single- Ended encoders. A complete list of pin assignments on the RPM F.B. connector is shown in the Dyn-Loc IV User Manual (Chapter 8). o Magnetic Pickup Unit Wiring If the system uses a Magnetic Pickup, refer to the table below, the Dyn-Loc IV User Manual and supplied drawings for wiring details. Complete the sensor wiring as indicated. Magnetic Pickup Belden 8761 (Item 1 in Cable table) Pin Wire Function A Clear MAGPU (+) B Black MAGPU (-) C Shield Not connected on the sensor end V1.0 3

o Single-Ended Encoder Wiring If the system uses an Encoder, refer to the table below, the Dyn-Loc IV User Manual and supplied drawings for wiring details. Complete the sensor wiring as indicated. Encoder Single Ended Output Belden 9534 (Item 2 in Cable table) Pin Wire Function G Red Encoder Excitation (+12 VDC) C Black Encoder Excitation Common Shield Not connected on the sensor end D Green Direction (Optional) E Green Channel B (Optional) F White Channel A NOTE: Never apply power to the Dyn-Loc IV during sensor wiring. The cable shield must be connected on the Dyn-Loc IV end only, leave shields unconnected at the transducer end to avoid ground loop signal problems. Single-ended encoders require additional hardware adjustments. 3. Using the DIP switches listed below select the type of speed feedback input source you are using. The following DIP switches are located on the DS501 circuit board (bottom center board inside the Dyn-Loc IV): SW3-3 SW3-4 SW1-1 SW1-2 SW1-3 Setting OFF ON OFF OFF OFF Two wire magnetic pickup. ON OFF OFF OFF OFF ON OFF ON OFF OFF ON OFF OFF ON OFF ON OFF OFF OFF ON Encoder pickup non-direction sensitive. Encoder pickup with direction bit output. Encoder pickup with direction derived from B channel encoder signal. Encoder pickup with direction derived from two channel encoder signal but inverts the direction. 4. Energize both the control and field transformers. 5. Test speed transducer by rotating the system (by hand if possible). A speed reading should appear on the RPM display. NOTE: If a magnetic pickup is used, a minimum speed (as a few hundred rpm) may be as high required before a RPM reading is displayed. 4 V1.0

4 TORQUE TRANSDUCER CONNECTION & CONFIGURATION Refer to the Dyn-Loc IV User Manual (Chapter 8, Section 2) for details on wiring and (Chapter 4, Sections 5-9) for configuring a torque transducer. All torque transducers are terminated at the LOAD CELL connector located on the back of the Dyn-Loc IV. A mating 6-pin MS connector is required and can be constructed using items 11 and 12 listed in the Connector Components table at the end of this document. Follow these steps in the order presented: 1. Ensure all incoming power is de-energized prior to proceeding. 2. Determine the type of torque transducer to be used. Two types of torque transducers are supported: Load Cell and Inline Sensor. A complete list of pin assignments on the LOAD CELL connector is shown in the Dyn-Loc IV User Manual (Chapter 8, Section 2). NOTE: Some sensors labeled Inline Torque Sensors should be wired and configured as a Load Cell. Contact Dyne Systems for assistance with this configuration. 3. Refer to the following tables, the Dyne-Loc IV User manual and supplied drawings for wiring details. Complete the sensor wiring as appropriate. Load Cell Belden 9534 (Item 2 in Cable table) Pin Wire Function A Red Excitation (+10 VDC) D Black Shield Excitation Common Excitation Common C Green Input (+) Signal B White Input (-) Signal DS105 PC board (solder) jumpers: JP2 installed, JP1 not installed In-Line Torque Sensor Belden 8761 (Item 1 in Cable table) Pin Wire Function B Clear Torque Sensor Input Both C and D Black Torque Sensor Input Common D Shield DS105 PC board (solder) jumpers: JP1 installed, JP2 not installed NOTE: Never apply power to the Dyn-Loc IV during sensor wiring. The cable shield must be connected on the Dyn-Loc IV end only, leave shields unconnected at the transducer end to avoid ground loop signal problems. Additional hardware may be required for In-Line torque sensor applications. V1.0 5

4. The torque display decimal point location is set from the Dyn-Loc IV front panel. Access the DIP switches by removing the torque display bezel. Set switches #4 and #5 as shown on the table below. Torque Display Decimal Place TQ display Switch #5 TQ display Switch #4 TQ Display OFF OFF 00000 OFF ON 0000.0 ON OFF 000.00 ON ON 00.000 NOTE: The power display decimal point location matches the torque display decimal point. When configuring lever wheel set points (torque), an implied decimal place must be used to match the displayed decimal point location. 5. Ensure that the dynamometer and sensor mounting are free of any external forces that could interfere with torque readings. 6. Energize both the control and field transformers. 7. Calibrate the torque transducer as follows: a. Attach the calibration arm to the dynamometer and attach the weight hanger. b. Press and release the AUTO ZERO button on the Dyn-Loc IV. This will zero the torque display. c. Hang the calibration weights. Calculate the calibration torque reading by multiplying the check arm length (from the dynamometer nameplate) with the amount of weight applied. = h h d. Configure the active lever wheel for the calculated calibration torque and press the Auto-Span button to calibrate. e. Remove the calibration weights. f. Ensure the torque display returns to zero. If yes proceed to step g, if no, return to step b. g. Remove weight hanger, and calibration arm. h. Press and release the AUTO ZERO button on the Dyn-Loc IV. i. Ensure the torque display value returns to zero, if not, return to step h. 6 NOTE: Refer to the HELP number descriptions in the Dyn-Loc IV User Manual (Chapter 9) for HELP XXXX messages appearing on the display during the calibration process. When the eddy-current dynamometer is absorbing and the system is rotating with positive speed values, the torque readings should also be positive. If not, a wiring error may exist. (If so, swap wires on pins B and C of the 6 pin M.S. torque connector) V1.0

8. Refer to the calibration section of the Dyn-Loc IV User Manual for additional calibration information. NOTE: In-line torque sensors can be calibrated either with calibration arms and weights or by performing a shunt calibration. (Refer to Chapter 4 of the Dyne-Loc IV User Manual) 5 EDDY-CURRENT POWER AMPLIFIER CONNECTIONS The internal Eddy-Current Power Amplifier (ECPAU) must be connected to the dynamometer coil (F1, F2) and the external field transformer (L1, L2) (See Section 2 Dyn Loc IV Power Connections). The water safeties of the dynamometer must also be wired to the H20 and IL terminals on the barrier strip. NOTE: The ECPAU internal to the Dyn-Loc IV is rated for 277VAC maximum and 16AMPS maximum. If dynamometer coil specifications exceed these values an external ECPAU is required, contact Dyne Systems for additional information. 6 WATER SAFETY INTERLOCK Water safety interlocks on the Dyn-Loc IV are critical in detecting a dynamometer coolant loss condition. Loss of coolant while the dynamometer is being loaded will result in overheating and likely cause severe damage to the dynamometer. The water safeties interlock can be found on the barrier strip on the back of the Dyn- Loc IV. The water safeties interlock connections are located on the left end of the barrier strip and are labeled as H20 and I.L.. Safety devices, such as pressure, flow, and temperature dry contacts, must be connected in series. When adequate coolant pressure and flow is supplied to the dynamometer all these contacts should be closed. Without closed water safeties the Dyn-Loc IV will not maintain a DYNE ON condition. NOTE: Only use dry contacts, which are contacts not connected to any other circuits or power sources. V1.0 7

7 FIELD CURRENT ADJUSTMENTS DYNAMOMETER CURRENT SETTING The current limit adjustment is made using the CFB (Current Feedback) potentiometer on the DS256 circuit board (location: Dyn-Loc IV left side panel). This adjustment allows adaptation to a wide range of dynamometer field specifications, provides protection for the dynamometer coil, and can influence stability of the dynamometer s control. NOTE: The fuses located on the rear panel of the Dyn-Loc IV must be sized to protect the dynamometer coil. The minimum fuse size allowed is 2.0A. The fuse chosen should provide adequate over-current and short circuit protection and be sized based on the field coil current rating on the dynamometer s nameplate. The voltage rating of the fuse must exceed the voltage used on the secondary of the field transformer. Use the following procedure for eddy current dynamometers only. As mentioned in Section 5, if the dynamometer nameplate calls for more than 16 Amps field current, or the field transformer is greater than 277VAC, an external ECPAU must be used. Exceeding these limitations will damage the Dyn-Loc IV. 1. Ensure Dyn-Loc IV is powered down. 2. Determine the appropriate current measurement location for the application: a. Clamp on a current meter, capable of measuring DC current, around one of the dynamometer field wires. b. Voltage measurement from test points TP7 to TP8 on the DS256 board. In standard applications, 0.01 volts across the resistor is equivalent to 1 amp of field current. TP7 and TP8 is equivalent to the voltage across the gold power resistor found on the heat sink. 3. Turn the CFB potentiometer fully clockwise (1.2 Amps minimum field current will result) 4. Determine the specified field current rating (on nameplate) for the dynamometer. Where applicable, use the hot amps (lesser) value. 5. Apply power to the Dyn-Loc IV 6. Assure the dynamometer is at a standstill 7. Press the TORQUE push button. 8. Set the active lever wheel switches to 9000. 9. Press the DYNE ON push button. NOTE: If the H2O interlocks are made, the control should latch DYNE ON. If the DYNE ON lamp drops out, check the H2O Interlock. If the under speed trip has not been disabled, the Dyn-Loc should trip after about one second. This will cause the OS/US RESET push button to light and a high braking condition (current limit) on the field. You will have one minute to adjust the CFB potentiometer. If it times out repress the DYNE ON button. 10. Turn CFB potentiometer counter-clockwise until you achieve the dynamometer rated field current. Do not exceed the field rating. 11. Push DYNE OFF push button, and OS/US RESET push button simultaneously. Leave the meter connected for the next test. 8 V1.0

ADJUSTING THE FAULT CURRENT The fault current is the current that will be applied to the field if an E-stop, over speed, or under speed occurs. The fault current needs to be adjusted for the application, adjust the fault current as follows: 1. Press the RPM push button to place the controller in RPM mode. 2. Press E-Stop button. NOTE: You will have one minute to adjust the Fault Brake pot found on the DS501 board. This is the center board found in the bottom of the Dyn-Loc. The DYNE ON times out after one minute. If adjustments are incomplete, press the DYNE ON button again. 3. Press the E-Stop reset button 4. Press DYNE OFF push button and OS/US RESET push button simultaneously 8 ENABLING THE DEVICE UNDER TEST (DUT) An eddy-current dynamometer is an energy absorbing device that is not capable of driving a system. The eddy-current dynamometer is driven by the DUT, typically either an engine or an electric motor. Follow these steps in the order presented: NOTE: Speed control of the DUT is required for the below process. 1. Enable the DUT speed control and rotate the system to a safe speed. 2. Be sure that stable speed control of the DUT is achieved. 3. After the DUT and dynamometer are rotating and a speed value is displayed on the Dyn-Loc IV, proceed to Section 9 Enabling the Dyn-Loc IV Controller. V1.0 9

9 ENABLING THE DYN-LOC IV CONTROLLER Before enabling the controller for the first time, set the over speed trip by using the thumb wheel switches on the back of the Dyn-Loc IV. Based on DUT performance specifications, select an appropriate over-speed value. Note that the over-speed setting is in x100 rpm increments. IF STARTING IN TORQUE MODE: 1. Press the TORQUE push button, this will put the Dyn-Loc IV in Torque Control Mode. 2. Set the desired Linear Acceleration (LAC, also known as ramp rate) into the active lever wheels. 3. Press the LAC SET button to set the Linear Acceleration (display units per second) value. NOTE: LAC should be set to match application requirements. 4. Set both front lever wheels to different desired torque setpoint values. 5. Press the DYNE ON button. 6. Observe, the Dyn-Loc IV should control to the active torque setpoint. Ensure accurate and stable control response. 7. Press the non-illuminated ACTIVE button. 8. Observe, the Dyn-Loc IV should control to the newly active torque setpoint. Ensure accurate and stable control response. 9. When done, press the DYNE OFF button (next to the lever wheel switch) to unload the device under test. IF STARTING IN SPEED MODE: 1. Press the RPM push button, this will put the Dyn-Loc IV in Speed Control Mode. 2. Set the desired Linear Acceleration (LAC, also known as ramp rate) into the active lever wheels. 3. Press the LAC SET button to set the Linear Acceleration (display units per second) value. NOTE: LAC should be set to match application requirements. 4. Set both front lever wheels to different desired speed setpoint values. The active setpoint value must match idle/base speed of the DUT. The inactive setpoint value must be just under the idle/base speed of the DUT. 5. Press the DYNE ON button. 6. Observe, the Dyn-Loc IV should control to the active speed setpoint. This should result in little speed variation and minimal torque application. 7. Press the non-illuminated ACTIVE button. 8. Observe, the Dyn-Loc IV should control to the newly active speed setpoint. Ensure accurate and stable control response. 9. When done, press the DYNE OFF button (next to the lever wheel switch) to unload the device under test. 10 V1.0

REFERENCE CONNECTORS AND RELATED PARTS CABLE: Item Description Manufacturer + P/N 1 Multi-conductor cable, 1 twisted pair, 22 AWG, shielded Belden 8761 2 Multi-conductor cable, 4 conductors, 24 AWG, shielded Belden 9534 CONNECTOR COMPONENTS: Item Description Manufacturer + P/N 1 15 Pin, DSUB Connector Male for 4QUAD AMP 205206-9 2 25 Pin, DSUB Connector Male for DTC AMP 5205208-1 3 37 Pin, DSUB Connector Male for REMOTE AMP 205210-8 4 Male Crimp Pin for DSUB Connector AMP 205089-1 5 Female Crimp Pin for DSUB Connector AMP 205090-1 6 Metalized Plastic Shell for 15 Pin DSUB Connector 3M 3357-6515-1C 7 Metalized Plastic Shell for 25 Pin DSUB Connector 3M 3357-6525-1C 8 Metalized Plastic Shell for 37 Pin DSUB Connector 3M 3357-6537-1C 9 7 Pin Male RPM AMPH MS3106A-16S-1P 10 7 Pin Strain Relief AMPH 97-3057-1008-1 11 6 Pin Male LOAD CELL AMPH MS3106A-14S-06P 12 6 Pin Strain Relief AMPH 97-3057-1007-1 13 9 Pin DSUB Connector Female for Serial Port AMP 205203-1 14 Metalized Plastic Shell for 9 Pin DSUB Connector 3M 3357-6509-1C V1.0 11