Medium Voltage Distriution Ringmaster Ring Main Unit Catalogue 2009
A new path for achieing your electrical installations A comprehensie offer The Ringmaster range is part of a comprehensie offer of products that are perfectly coordinated to meet all medium and low oltage electrical distriution requirements. All of these products hae een designed to work together: electrical, mechanical and communication compatiility. The electrical installation is thus oth optimised and has improed performance: @ etter serice continuity, @ increased personnel and equipment safety, @ guaranteed upgradeaility, @ effi cient monitoring and control. You therefore hae all the adantages at hand in terms of know-how and creatiity for achieing optimised, safe, upgradeale and compliant installations. Tools for facilitating the design and installation With Schneider Electric, you hae a complete range of tools to help you get to know and install the products whilst complying with current standards and good working practices. These tools, technical sheets and guides, design software, training courses, etc are regularly updated. Schneider Electric is associating itself with your know-how and your creatiity to produce optimised, safe, upgradeale and compliant installations For a real partnership with you A uniersal solution doesn t exist ecause each electrical installation is specifi c. The ariety of cominations on offer allows you to truly customise the technical solutions. You are ale to express your creatiity and put your know-how to est adantage when designing, manufacturing and exploiting an electrical installation.
General contents Presentation 2 Applications 2 Switchgear description 3 VIP protection relays 5 Network remote control 6 Ringmaster selection guide 8 9 Ring main units 10-25 Circuit reaker, metering and switches 26-65 Remote control 66-68 Section 2 69 Installation drawings 70-80 Schematic diagrams 81-112 Section 3 113 114-119 Section 4 121 Schneider Electric, an oeriew and order form 122-128 AMTED399086EN.indd 1
Presentation Applications Ringmaster is the ideal choice for all your MV applications. From simple transformer protection, or sectionalising with remote control, to multi-panel metered consumer switchoards, the Ringmaster range from Schneider Electric offers a solution. Quality engineering for extreme climates enales Ringmaster to proide flexiility for any location. Coering a wide range of options with an indoor and outdoor design and ratings up to 13.8 kv, 630 A and 21 ka, Ringmaster has proed successful in markets around the world. Product adantages Simple, clear operation comined with compact size, high functionality and reliaility extends the applications of the Ringmaster range. Safety to personnel Fully certified internal arc design. design No need for expensie switchrooms. Self powered protection Not reliant on costly attery chargers. Compact Reduced dimensions, gies reduced ciil costs. Virtually maintenance free Low lifetime costs. Modular design Quick, simple & easy to install. Proen design Assured consistent quality. ISO 9001 quality certification. PE40438 Enironmental Manufactured to ISO 14001 enironmental standards. 2 AMTED399086EN.indd
Presentation Switchgear description A ariety of different panel types are aailale for each unit within the range, together with a numer of optional accessories enaling Ringmaster to satisfy the most complex system specification. A multitude of configurations PE57061 Free standing, non-extensile, cale connected ring main unit. Transformer mounted, non-extensile ring main unit, incorporated in a packaged sustation. Free standing, extensile cale connected ring main unit Transformer mounted, extensile ring main unit, incorporated in a packaged sustation. PE57063 PE57066 PE57062 PE57065 PE57064 Free standing, non-extensile circuit reaker. Cale connected extensile switchoard. AMTED399086EN.indd 3
Presentation Switchgear description PE57067 General characteristics Gas pressure indicator as standard Anti-reflex operating handle with facilities for electrical operation Interlocked MV cale test access (no need to remoe cale terminations or use loose earthing deices) Integral self-powered protection with TFL, adjustale cure & relay options enclosure Simple to follow mimic proiding user-friendly operation Earth screened cast-resin gas module Range of dry type metering units Mechanical tripped on-fault indication Resin encapsulated usars in air us chamer for extensile ersion Direct coupling to transformers or cale connection. Standard and quality assurance Manufactured to BS EN ISO 9001. Ringmaster meets the following standards and has otained approal from the UK Electricity Association: IEC 56, IEC 60265, IEC 62271-200, BS EN 60265 and EATS 41-26. 4 AMTED399086EN.indd
Presentation VIP protection relays Self-powered reliaility PE57160 VIP 300 - the leading protection relay proiding a wide range of selectiity and quality of supply The VIP 300 is a three phase oercurrent and earth fault protection deice, proiding protection for networks and equipment. Being an integral part of the highly successful Ringmaster range, its main function is to detect phase and earth faults within the network and to trip the circuit reaker. PE57159 VIP 300 Pick-up current ranges: RN2c, RE2c, CN2, CE2 Oercurrent: 20A-200A. Earth fault: 2A-160A. CE6 and RN6c Oercurrent: 80A-800A. Earth fault: 8A to 640A. Hardened electronics Certified EMC performance to IEC 60255 and EN 50061, EN50082. Separate oercurrent and earth fault trip indication. Flashing LED s indicate when the relay is operating under fault conditions. Flexiility The relay proides for a wide range of protection settings for most applications. The IDMT characteristics employed for oth the oercurrent and earth fault elements can e easily adjusted to proide discrimination with upstream MV and downstream LV protectie deices. Fast power-up of the VIP 300 also proides immediate protection and can detect faults instructing the CB to trip in less than 40ms. Reliaility The relay has a self monitoring deice and diagnostic routine that constantly checks the operation of the relay automatically. Self-powered reliaility The VIP 300 protection relay is a self powered microprocessor ased deice which requires no external DC power source or atteries, making it the ideal solution for location in remote areas where auxiliary supplies are not readily aailale. Ease of use VIP 300 has improed operation and control with the relay settings eing clearly displayed on the front panel. Manual reset flags show separate tripped on fault for either phase or earth fault conditions. VIP 35 proides protection against phase-to-phase faults and earth faults. Testing The VAP 6 hand held test unit, is aailale to proide a simple check of the integrity of the relay and can also e used to perform trip tests on the circuit reaker. The circuit reaker trip inhiit facility allows the relay to e tested without tripping the circuit reaker. Secondary injection can e carried out using conentional test equipment. PE56826 The VIP 30 and VIP 35 are self-powered deices, requiring no external DC power source or atteries. They are designed for use in distriution networks proiding protection for transformers. VAP 6 AMTED399086EN.indd 5
Presentation Network remote control T200E telecontrol Ringmaster and T200E Control your Ringmaster from a remote position The Schneider Electric Easergy T200E telecontrol cainet, which links the Ringmaster to a control centre s automation system, allows you to manage a secondary distriution network from a remote point. Network faults can e identified and isolated and the network reconfigured in seconds without manual interention, which sustantially improes the quality of supply. The small and compact Easergy T200E can e easily mounted directly onto the Ringmaster, saing installation costs and aluale floor space. Telecontrol equipment can e added any time after installation. This makes Ringmaster RMU s een more cost-effectie to install, since a control system can e ought separately if needed at a later date. Other RTUs can also e integrated if required. PE57069 PE57071 Internal iew of Easergy T200E Ringmaster C with Easergy T200E 6 AMTED399086EN.indd
Presentation Network remote control Easergy L500 Continuity of serice guaranteed y an oerall telecontrol offer Schneider Electric offers you a complete solution, including: the Easergy T200 E telecontrol interface, MT switchgear that is adapted for telecontrol. PE56312 DE40901EN HV/MV RN2C RN2C RN2C MV ring L500 network monitoring screen Network control centre RN2C Communication network RN2C RN2C PE57073EN Easergy L500, a low cost solution to immediately improe your SAIDI * * SAIDI: system aerage interruption duration index Easergy L500 is a SCADA proiding all the functions needed to operate the MV network in real time Pre-configured with Easergy range products: MV/LV sustations equipped with T200 E or Flair 200C oerhead line equipped with Flite 116/G200 Broad range of transmission supports: Radio, GSM, GPRS, PSTN, LL, FO. Adantages Simple implementation: one to two weeks only for 20 MV/LV sustations configuration, training and handling within a few days Short return on inestment Simple and fast eolutions y operations managers Serice quality and operations rapidly improed. AMTED399086EN.indd 7
Presentation Ringmaster selection guide PE57072 RN2c RE2c RN6c MU2 CN2 SN6 CE2 CE6 SE6 200 A non extensile ring main unit 200 A extensile ring main unit 630 A non extensile ring main unit 200 A feeder metering unit 200 A non extensile circuit reaker 630 A non extensile switch 200 A extensile circuit reaker 630 A extensile circuit reaker 630 A extensile switch Key to product references Ringmaster is aailale as standard panel types, allowing easy selection and specification. The product references are made up as follows: R Ring main unit 2 200 A C Circuit reaker 6 600 A S Switch 16 16 ka N Non-Extensile 21 21 ka E Extensile MU Metering unit Example: CN2-T1/16 = circuit reaker, non extensile, 200 A, 16 ka fault rating. The Ringmaster catalogue allows easy selection and specification, ased on a road range of worldwide applications. Included in this pulication is: panel type specifications details of optional accessories schematic diagrams Installation drawings. for the Ringmaster range are supplied either fitted or loose, where stated enaling simple panel configuration on site. Details of accessories are contained within the panel type pages. General arrangement drawings General arrangement drawings are gien for each panel type. This allows you to quickly size up switchrooms and calculate external connections at the pre-order stage. Need more information? If your requirements are not listed, please contact your local Schneider Electric representatie, or contact us on: Tel: +44(0) 113 290 3500 Email: MVswitchgearGB@schneider.co.uk Electronic catalogue requests Electronic copies of this selection guide are aailale free of charge upon request. For this, and other MV literature, please email your full contact details to Email: MVswitchgearGB@schneider.co.uk 8 AMTED399086EN.indd
Contents Ring main units Non-extensile ring main unit 200A RN2c-T1, RN2c-T2, RN2c-T3, RN2c-T4, RN2c-T5 10-17 Non-extensile ring main unit 630A RN6c-T1 18 Extensile ring main unit 200A RE2c-T1, RE2c-T2, RE2c-T3, RE2c-T4 19-25 Circuit reaker, metering and switches Non-extensile circuit reaker - 200A CN2-T1, CN2-T6 26-29 Non-extensile Switch 630A SN6-S1, SN6-S2 30-33 Non-extensile metering unit - 200A MU2-M1, MU2-M2, MU2-M3 34-38 Extensile circuit reaker - 200A T2, T7, T*, T12, T**, T13, T15, T16 39-49 Extensile circuit reaker - 630A CE6-T4, CE6-T*, CE6-T8, CE6-T** 50-55 Extensile switch - 630A SE6-S1, SE6-S2, SE6-E1 56-60 Extensile us section - 630A SE6-B1, CE6-B3, CE6-B5 61-65 Remote control Telecontrol unit Easergy T200-E01M, Easergy T200-E04M 66-68 AMTED399086EN.indd 9
Ring main units non-extensile Specification RN2c-T1 TFL RN2c-T2 VIP 300 RN2c-T3 VIP 30 RN2c-T4 VIP 35 RN2c-T5 Glass TFL RN6c-T1 VIP 300 Enironment Indoor / outdoor Transformer mounted Freestanding O O O O O Busars 630A Circuit reaker normal rated current 200A Circuit reaker normal rated current 630A Switch normal rated current 630A 12kV 16kA 3 seconds 75kV BIL 13.8kV 21kA 3 seconds 95kV BIL O O O O O O Ring switch cale earth switch 16kA 3 seconds Ring switch cale earth switch 21kA 3 seconds O O O O O O Circuit reaker earth switch 3.15kA Mechanism Independent manual Proision for motorised mechanism LH ring switch Proision for motorised mechanism RH ring switch Proision for motorised mechanism circuit reaker O O O O O O Protection & control - circuit reaker CT s dual ratio - 100/50/5A class X CT s ratio - 200/1A class X CT s ratio - 500/200/1A class X CT s ratio - 800/400/1A class X Oercurrent & earth fault CT operated trip coils - TFL Oercurrent & earth fault CT operated trip coils - glass TFL Oercurrent relay - VIP 30 Oercurrent & earth fault relay - VIP 35 IDMT oercurrent & earth fault relay - VIP 300 Multi oltage shunt trip coil (see accessories page 11) O O O O O O Mechanical ON/OFF Mechanical EARTH/MAIN Neon indication 3.3-13.8kV O O O O O O Gas pressure indicator (-25 C to +55 C) RSW aux contacts 1NO & 1NC O O O O O O Integral ring cale test facility Integral circuit reaker test facility O O O O O Operating handle Cale (see aailale cale kit accessories) Bottom entry up 1 x 3C 300mm 2 Bottom entry up 3 x 1C 630mm 2 Top entry cales (indoor only) O O O O O O Order codes 12kV, 16kA, 75kV BIL, 0.35G RN2c-T1/16 RN2c-T2/16 RN2c-T3/16 RN2c-T4/16 RN2c-T5/16 RN6c-T1/16 13.8kV, 21kA, 95kV BIL, 0.8G RN2c-T1/21 RN2c-T2/21 RN2c-T3/21 RN2c-T4/21 RN2c-T5/21 RN6c-T1/21 General arrangement drawing - transformer mounted General arrangement drawing - freestanding Schematic diagram - TFL Schematic diagram - VIP 30 Schematic diagram - VIP 35 Schematic diagram - VIP 300 Key: Standard feature O Optional feature RMINST-06 Page 77 RMINST-05 Page 116 RMSCH-01 Page 85 RMINST-06 Page 77 RMINST-05 Page 116 RMSCH-03 Page 86 RMINST-06 Page 77 RMINST-05 Page 116 RMSCH-02 Page 87 RMINST-06 Page 77 RMINST-05 Page 116 RMSCH-15 Page 88 RMINST-06 Page 77 RMINST-05 Page 116 RMSCH-01 Page 85 RMINST-06 Page 77 RMINST-05 Page 116 RMSCH-42 Page 89 10 AMTED399086EN.indd
Ring main units non-extensile RN2c-T1 TFL RN2c-T2 VIP 300 RN2c-T3 VIP 30 RN2c-T4 VIP 35 RN2c-T5 RN6c-T1 Glass TFL VIP 300 Cale kits Circuit reaker cale ox RMR-A/F47 Circuit reaker cale ox with integral cale test facility RMR-F325 Gland plate 1 x 3C O O O O O O RMR-A316 Gland plate 3 x 1C O O O O O O RMR-A319 Small gland plate 1 x 3c O O O O O O RMR-A322 Blank aluminium gland plate O O O O O O RMR-A320 Brass wiping gland 1 x 3C O O O O O RMR-A10 Brass wiping gland 3 x 1C O O O O O O RMR-A11 Small rass wiping gland 1 x 3c O O O O O O RMR-A105 Tuular gland 1 x 3C O O O O O O RMR-A12 Tuular gland 3 x 1C O O O O O O RMR-A13 Small tuular gland O O O O O O RMR-A106 CES5 gland O O O O O O RMR-A120 CES5 gland plate 1 x 3C O O O O O O RMR-A321 CES5 gland adaptor O O O O O O RMR-A525 6 x ECON cale termination kit O O O O O O RMR-A314 3 x STD ECON end cap O O O O O O RMR-A370 3 x ECON cale termination kit O O O O O O RMR-A315 Top entry cales RH cale ox (indoor only) RMR-F303 Top entry cales LH cale ox (indoor only) RMR-F302 Rsw extension ox for 2 x 3C cales (left hand) RMR-F523 Rsw extension ox for 2 x 3C (right hand) RMR-F522 Angled gland plate 1 x 3C O O O O O O RMR-A317 Split gland plate 1 x 3C O O O O O O RMR-A318 Installation items Transformer mounting kit RMR-A/F323 Extension trunking (to clear transformer radiators) O O O O O O RMR-A20 Set of padlocks - 11 no O O O O O O RMR-A343 Anti-andal fixings, including tool O O O O O O RMR-A344 Foundation olts (not required for transformer mounting) O O O O O O RMR-A22 Multicore pilot glands O O O O O O RMR-A342 Time limit fuses (set of 2 - specify rating as tale page 115) O O O O O O RMR-A17 RN2c to MU2 installation kit RMR-A350 Ariel mounting racket O O O O O O RMR-A201 Operational items Operating handle RMR-F345 LH ring switch control auxiliary sw for motorised RMR-F328 mechanism proision LH ring switch termination lock for motorised RMR-F363 mechanism proision (not Easergy) RH ring switch control auxiliary sw for motorised RMR-F329 mechanism proision RH ring switch termination lock for motorised RMR-F364 mechanism proision (not Easergy) Proision for motorised mechanism circuit reaker RMR-F543 Motorised mechanism - specify oltage RMR-F507 CB Termination lock for motorised RMR-F365 mechanism proision (not Easergy) Shunt trip coil (20-250V DC, 110-250V AC) TLF RMR-F581 Shunt trip coil (20-250V DC, 110-250V AC) VIP RMR-F582 Ring switch cale neon indication (11-13.8kV) RMR-F341 Ring switch cale neon indication (3.3-7.2kV) RMR-F348 Circuit reaker cale neon indication (11-13.8kV) RMR-F340 Circuit reaker cale neon indication (3.3-7.2kV) RMR-F347 Phase indication deice O O O O O O RMR-A374 VAP 6 test unit for VIP 300/30/35 O O O O O O RMR-A202 Emergency trip push utton RMR-F339 Gas pressure switch for remote indication only RMR-F368 Key: Standard feature Factory fitted accessory O Loose accessory, assemled on site Kit no. AMTED399086EN.indd 11
Ring main units non-extensile RN2c-T1 TFL RN2c-T2 VIP 300 RN2c-T3 VIP 30 RN2c-T4 VIP 35 RN2c-T5 RN6c-T1 Glass TFL VIP 300 Mechanical interlocks Circuit reaker - key free, EARTH ON RMR-F337 Circuit reaker - key free, MAIN OFF RMR-F338 Switch - key free, SWITCH OFF LH RMR-F335 Switch - key free, SWITCH OFF RH RMR-F336 N. B. specify lock symol at time of ordering ( 3 digits max) not aailale with motor mechanisms Earth fault passage indication (choose proision kit and an EFPI required if not using Easergy T200E) Phase & earth fault proision for Easergy T200E O O O O O O RMR-F310 EFPI proision kit, inside cale ox O O O O O O RMR-A304 EFPI proision kit, CT outside cale ox O O O O O O RMR-A305 EFPI proision kit, inside cale ox, top entry O O O O O O RMR-A308 EFPI proision kit, outside cale ox, top entry O O O O O O RMR-A309 Bowden RR EFPI and CT O O O O O O RMR-A422 Bowden STD EFPI type NB O O O O O O RMR-A277 Bowden LV reset EFPI type NB1 O O O O O O RMR-A278 Bowden LV reset & alarm type NB2 O O O O O O RMR-A279 Fundamentals ER FIND EFPI and CT O O O O O O RMR-A57 N. B. aoe CT s are ring type for split core - please consult Schneider Electric Key: Factory fitted accessory O Loose accessory, assemled on site Kit no. 12 AMTED399086EN.indd
Non-extensile ring main unit 200 A RN2c-T1 DE60180 DE60181 Transformer protection up to 1.6MVA at 11kV Protection & control - CB Oercurrent and earth fault protection using CT operated trip coils with proision for time fuse links Protection CT s - 100/50/5A class X Transformer ratings See tale - page 119 Documents Transformer mounted installation drawing ref: RMINST-06 Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-01 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A/200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Ring cale earth switch, 16/21kA 3s Transformer earth switch, 3.15kA 3s Anti-reflex operating handle Proision for motorised mechanism LH/RH ring switch with plug interface Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Integral ring switch cale test facility Cale Bottom entry up to 1 x 3C 300mm 2 Bottom entry up to 3 x 1C 630mm 2 - see tale, page 11 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi oltage shunt trip coil 20V DC - 250V AC Neon indication Inerted cale oxes (indoor only) Transformer mounting kit Freestanding tee-off cale ox Order information Code RN2c-T1/16 RN2c-T1/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 13
Non-extensile ring main unit 200 A RN2c-T2 DE60180 DE60185 Transformer protection up to 3.5MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142 Protection CT s - 200/1A class X Setting range: Oercurrent: 20-200A Earth fault: 2-160A Transformer ratings See tale - page 119 Documents Transformer mounted installation drawing ref: RMINST-06 Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-03 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A/200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Ring cale earth switch, 16/21kA 3s Transformer earth switch, 3.15kA 3s Anti-reflex operating handle Proision for motorised mechanism LH/RH ring switch with plug interface Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Integral ring switch cale test facility Cale Bottom entry up to 1 x 3C 300mm 2 Bottom entry up to 3 x 1C 630mm 2 - see tale, page 11 CB LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi oltage shunt trip coil 20V DC - 250V AC Neon indication Inerted cale oxes (indoor only) Transformer mounting kit Freestanding tee-off cale ox Order information Code RN2c-T2/16 RN2c-T2/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 14 AMTED399086EN.indd
Non-extensile ring main unit 200 A RN2c-T3 DE60180 DE60182 MV transformer protection Protection & control - CB Self powered oercurrent relay, VIP 30. Protection CT s - 500/200/1A class X Setting range: 500/1A Oercurrent: 20-200A Setting range: 200/1A Oercurrent: 8-80A Transformer ratings See tale - page 119 Documents Transformer mounted installation drawing ref: RMINST-06 Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-02 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A/200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Ring cale earth switch, 16/21kA 3s Transformer earth switch, 3.15kA 3s Anti-reflex operating handle Proision for motorised mechanism LH/RH ring switch with plug interface Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Integral ring switch cale test facility Cale Bottom entry up to 1 x 3C 300mm 2 Bottom entry up to 3 x 1C 630mm 2 - see tale, page 11 CB, LH, RH motor kit LH, RH ring switch indication 1NO 1NC earth On 1NO Multi oltage shunt trip coil 20V DC - 250V AC Neon indication Inerted cale ox (indoor only) Transformer mounting kit Freestanding tee-off cale ox Order information Code RN2c-T3/16 RN2c-T3/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 15
Non-extensile ring main unit 200 A RN2c-T4 DE60180 DE60183 MV transformer protection Protection & control - CB Self powered oercurrent and earth fault relay, VIP 35. Protection CT s - 500/200/1A class X CH30 core alance CT Setting range: 500/1A Oercurrent: 20-200A Earth fault: 25-300A Setting range: 200/1A Oercurrent: 8-80A Earth fault: 10-120A Transformer ratings See tale - page 119 Documents Transformer mounted installation drawing ref: RMINST-06 Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-15 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A/200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Ring cale earth switch, 16/21kA 3s Transformer earth switch, 3.15kA 3s Anti-reflex operating handle Proision for motorised mechanism LH/RH ring switch with plug interface Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Integral ring switch cale test facility Cale Bottom entry up to 1 x 3C 300mm 2 Bottom entry up to 3 x 1C 630mm 2 - see tale, page 11 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi oltage shunt trip coil 20V DC - 250V AC Neon indication Inerted cale oxes (indoor only) Transformer mounting kit Freestanding tee-off cale ox Order information Code RN2c-T4/16 RN2c-T4/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 16 AMTED399086EN.indd
Non-extensile ring main unit 200 A RN2c-T5 DE60180 DE60184 Transformer protection up to 1.6MVA at 11kV Protection & control - CB Oercurrent and earth fault protection using CT operated trip coils with proision for time fuse links (glass fuse link) Protection CT s - 100/50/5A class X Transformer ratings See tale - page 119 Documents Transformer mounted installation drawing ref: RMINST-06 Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-01 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A/200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Ring cale earth switch, 16/21kA 3s Transformer earth switch, 3.15kA 3s Anti-reflex operating handle Proision for motorised mechanism LH/RH ring switch with plug interface Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Integral ring switch cale test facility Cale Bottom entry up to 1 x 3C 300mm 2 Bottom entry up to 3 x 1C 630mm 2 - see tale, page 11 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi oltage shunt trip coil 20V DC - 250V AC Neon indication Inerted cale oxes (indoor only) Transformer mounting kit Freestanding tee off cale ox Order information Code RN2c-T5/16 RN2c-T5/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 17
Non-extensile ring main unit 200 A RN6c-T1 DE60180 DE60186 Network sectionalising up to 12MVA 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142 Protection CT s - 800/400/1A class X Setting range: 800/1A ratio Oercurrent: 80-800A Earth fault: 8-640A Setting range: 400/1A Oercurrent: 40-400A Earth fault: 4-320A Documents Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-42 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A/630A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Circuit reaker earth switch 16/21kA Ring cale earth switch, 16/21kA 3s Anti-reflex operating handle Proision for motorised mechanism LH/RH ring switch and circuit reaker with plug interface Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Integral ring switch and circuit reaker test facility Cale Bottom entry up to 1 x 3C 300mm 2 Bottom entry up to 3 x 1C 630mm 2 - see tale, page 11 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi oltage shunt trip coil 20V DC - 250V AC Neon indication Inerted cale oxes (indoor only) Freestanding Order information Code RN6c-T1/16 RN6c-T1/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 18 AMTED399086EN.indd
Extensile ring main units Specification RE2c-T1 TFL RE2c-T2 VIP 300 RE2c-T3 VIP 30 RE2c-T4 VIP 35 Enironment Indoor / outdoor Transformer mounted Freestanding Extensile (RHS) O O O O Busars 630A Circuit reaker normal rated current 200A Circuit reaker normal rated current 630A Switch normal rated current 630A 12kV 16kA 3 seconds 75kV BIL 13.8kV 21kA 3 seconds 95kV BIL O O O O Ring switch cale earth switch 16kA 3 seconds Ring switch cale earth switch 21kA 3 seconds O O O O Circuit reaker earth switch 3.15kA Extensile rmu usar chamer 630A O O O O Mechanism Independent manual Proision for motorised mechanism LH ring switch Proision for motorised mechanism RH ring switch Proision for motorised mechanism circuit reaker O O O O Protection & control - circuit reaker CT s dual ratio - 100/50/5A class X CT s ratio - 200/1A class X CT s ratio - 500/200/1A class X CT s ratio - 800/400/1A class X Oercurrent & earth fault CT operated trip coils - TFL Oercurrent & earth fault CT operated trip coils - glass TFL Oercurrent relay - VIP 30 Oercurrent & earth fault relay - VIP 35 IDMT oercurrent & earth fault relay - VIP 300 Multi oltage shunt trip coil (see accessories) O O O O Mechanical ON/OFF Mechanical EARTH/MAIN Neon indication 3.3-13.8kV O O O O Gas pressure indicator (-25 C to +55 C) RSW aux contacts 1NO & 1NC O O O O Integral ring cale test facility Operating handle Cale (see aailale cale kit accessories) Bottom entry up 1 x 3C 300mm 2 Bottom entry up 3 x 1C 630mm 2 Top entry cales* (indoor only) (left hand side only) O O O O Order codes 12kV, 16kA, 75kV BIL, 0.35G RE2c-T1/16 RE2c-T2/16 RE2c-T3/16 RE2c-T4/16 13.8kV, 21kA, 95kV BIL, 0.8G RE2c-T1/21 RE2c-T2/21 RE2c-T3/21 RE2c-T4/21 General arrangement drawing - freestanding RMINST-22, Page 75 RMINST-22, Page 75 RMINST-22, Page 75 RMINST-22, Page 75 Schematic diagram - TFL RMSCH-01, Page 85 Schematic diagram - VIP 30 RMSCH-02, Page 87 Schematic diagram - VIP 35 RMSCH-15, Page 88 Schematic diagram - VIP 300 RMSCH-03, Page 86 Key: Standard feature O Optional feature AMTED399086EN.indd 19
Extensile ring main units RE2c-T1 TFL RE2c-T2 VIP 300 RE2c-T3 VIP 30 RE2c-T4 VIP 35 Cale kits Extensile ring main units RMR-A/F47 Gland plate 1 x 3C O O O O RMR-A316 Gland plate 3 x 1C O O O O RMR-A319 Small gland plate 1 x 3C O O O O RMR-A322 Blank aluminium gland plate O O O O RMR-A320 Brass wiping gland 1 x 3C O O O O RMR-A10 Brass wiping gland 3 x 1C O O O O RMR-A10 Small rass wiping gland 1 x 3C O O O O RMR-A105 Tuular gland 1 x 3C O O O O RMR-A12 Tuular gland 3 x 1C O O O O RMR-A13 Small tuular gland 1 x 3C O O O O RMR-A106 CES5 gland O O O O RMR-A120 CES5 gland plate 1 x 3C O O O O RMR-A321 CES5 gland plate adaptor O O O O RMR-A525 6 x ECON cale termination kit O O O O RMR-A314 3 x STD ECON end cap O O O O RMR-A370 3 x ECON cale termination kit O O O O RMR-A315 3 x ECON end cap capacitors O O O O RMR-A371 Top entry cales LH cale ox (indoor only) RMR-F302 Angled gland plate 1 x 3C O O O O RMR-A317 Split gland plate 1 x 3C O O O O RMR-A318 Installation items Transformer mounting kit RMR-A/F323 Extension trunking (to clear radiators) O O O O RMR-A20 Set of padlocks - 11 no O O O O RMR-A343 Anti-andal fixings, including tool O O O O RMR-A344 Foundation olts (not required for transformer mounting) O O O O RMR-A22 Multicore pilot glands O O O O RMR-A342 Time limit fuses (set of 2 - specify rating as tale page 115) O O O O RMR-A17 RE2c to MU2 installation kit RMR-A350 Extensile usar chamer 630A O O O O RMR-F369 Ariel mounting racket O O O O RMR-A201 Operational items Operating handle RMR-F345 LH ring switch control auxiliary sw for motorised mechanism RMR-F328 proision LH ring switch termination lock for motorised mechanism RMR-F363 proision (not Easergy) RH ring switch control auxiliary sw for motorised mechanism RMR-F329 proision RH ring switch termination lock for motorised mechanism RMR-F364 proision (not Easergy) Proision for motorised mechanism circuit reaker RMR-F543 Motorised mechanism - specify oltage RMR-F507 Shunt trip coil (20-250V DC, 110-250V AC) TLF RMR-F581 Shunt trip coil (20-250V DC, 110-250V AC) VIP RMR-F582 Ring switch cale neon indication (11-13.8kV) RMR-F341 Ring switch cale neon indication (3.3-7.2kV) RMR-F348 Circuit reaker neon indication (11-13.8kV) RMR-F340 Circuit reaker neon indication (3.3-7.2kV) RMR-F347 VAP 6 test unit for VIP 300/30/35 RMR-A202 Emergency trip push utton RMR-F339 Gas pressure switch for remote indication only RMR-F368 Key: Standard feature Factory fitted accessory O Loose accessory, assemled on site Kit no. 20 AMTED399086EN.indd
Extensile ring main units RE2c-T1 TFL RE2c-T2 VIP 300 RE2c-T3 VIP 30 RE2c-T4 VIP 35 Kit no. Mechanical interlocks Circuit reaker - key free, earth on RMR-F337 Circuit reaker - key free, main off RMR-F338 Switch - key free, switch off LH RMR-F335 Switch - key free, switch off RH RMR-F336 N. B. specify lock symol at time of ordering (3 digits max) not aailale with motor mechanisms Earth fault passage indication (choose proision kit and an EFPI required if not using Easergy T200E) Phase & earth fault proision for Easergy T200E O O O O RMR-F310 EFPI proision kit, inside cale ox O O O O RMR-A304 EFPI proision kit, CT outside cale ox O O O O RMR-A305 EFPI proision kit, inside cale ox, top entry O O O O RMR-A308 EFPI proision kit, outside cale ox, top entry O O O O RMR-A309 Bowden RR EFPI and CT O O O O RMR-A422 Bowden STD EFPI type NB O O O O RMR-A277 Bowden LV reset EFPI type NB1 O O O O RMR-A278 Bowden LV reset & alarm type NB O O O O RMR-A279 Fundamentals ER FIND EFPI and CT O O O O RMR-A57 N. B. aoe CT s are ring type for split core - please consult Schneider Electric Key: Factory fitted accessory O Loose accessory, assemled on site AMTED399086EN.indd 21
Extensile ring main unit 200 A RE2c-T1 DE60211 DE60187 Multiple transformer feeders or network switching points Protection & control - CB Oercurrent and earth fault protection using CT operated trip coils with proision for time fuse links. Protection CT s - 100/50/5A class X Transformer ratings See tale - page 119 Documents Freestanding installation drawing ref: RMINST-22 Schematic drawing ref: RMSCH-01 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A/200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Ring switch cale earth switch, 16/21kA 3s Transformer earth switch, 3.15kA 3s Anti-reflex operating handle Extensile (RHS) Proision for motorised mechanism LH/RH ring switch with plug interface Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Integral ring switch test facility Cale Bottom entry up to 1 x 3C 300mm 2 Bottom entry up to 3 x 1C 630mm 2 - see tale, page 20 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi oltage shunt trip coil 20V DC - 250V AC Neon indication Integral circuit reaker test facility Inerted cale oxes LH, CB (indoor only) Transformer mounting kit Freestanding tee-off cale ox Order information Code RE2c-T1/16 RE2c-T1/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 22 AMTED399086EN.indd
Extensile ring main unit 200 A RE2c-T2 DE60211 DE60188 Multiple transformer feeders or network switching points Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS 142. Protection CT s - 200/1A class X Setting range: Oercurrent: 20-200A Earth fault: 2-160A Transformer ratings See tale - page 119 Documents Installation drawing ref: RMINST-22 Schematic drawing ref: RMSCH-03 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A/200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Ring switch cale earth switch, 16/21kA 3s Transformer earth switch, 3.15kA 3s Anti-reflex operating handle Extensile (RHS) Proision for motorised mechanism LH/RH ring switch Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Integral ring switch test facility Cale Bottom entry up to 1 x 3C 300mm 2 Bottom entry up to 3 x 1C 630mm 2 - see tale, page 20 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC Multi oltage shunt trip coil 20V DC - 250V AC Neon indication Inerted cale ox LH CB (indoor only) Transformer mounting kit Freestanding tee-off cale ox Order information Code RE2c-T2/16 RE2c-T2/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 23
Extensile ring main unit 200 A RE2c-T3 DE60211 DE60189 MV transformer protection Protection & control - CB Self powered oercurrent relay, VIP 30. Protection CT s - 500/200/1A class X Setting range: 500/1A Oercurrent: 20-200A Setting range: 200/1A Oercurrent: 8-80A Transformer ratings See tale - page 119 Documents Installation drawing ref: RMINST-22 Schematic drawing ref: RMSCH-02 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A/200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Ring switch cale earth switch, 16/21kA 3s Transformer earth switch, 3.15kA Anti-reflex operating handle Extensile (RHS) Proision for motorised mechanism LH/RH ring switch Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Integral ring switch test facility Cale Bottom entry up to 1 x 3C 300mm 2 Bottom entry up to 3 x 1C 630mm 2 - see tale, page 20 CB, LH, RH motor kit LH, RH ring switch indication 1NO 1NC Multi oltage shunt trip coil 20V DC - 250V AC Neon indication Inerted cale oxes LH, CB (indoor only) Transformer mounting kit Freestanding tee-off cale ox Order information Code RE2c-T3/16 RE2c-T3/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 24 AMTED399086EN.indd
Extensile ring main unit 200 A RE2c-T4 DE60211 DE60190 MV transformer protection Protection & control - CB Protection & control - CB Self powered oercurrent and earth fault relay, VIP 35. Protection CT s - 500/200/1A class with CH30 core alance CT Setting range: 500/1A Oercurrent: 20-200A Earth fault 25-300A Setting range: 200/1A Oercurrent: 8-80A Earth fault 10-120A Transformer ratings See tale - page 119 Documents Installation drawing ref: RMINST-22 Schematic drawing ref: RMSCH-15 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A/200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Ring switch cale earth switch, 16/21kA 3s Transformer earth switch, 3.15kA 3s Anti-reflex operating handle Extensile (RHS) Proision for motorised mechanism LH/RH ring switch Mechanical tripped on fault indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC Earth position selected 1NO Earth ON, 1NO Integral ring switch test facility Cale Bottom entry up to 1 x 3C 300mm 2 Bottom entry up to 3 x 1C 630mm 2 - see tale page 20 CB, LH, RH motor kit LH, RH ring switch indication 1NO 1NC Multi oltage shunt trip coil Neon indication Inerted cale oxes LH, CB (indoor only) Transformer mounting Freestanding tee-off cale ox Order information Code RE2c-T4/16 RE2c-T4/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 25
Non-extensile circuit reakers 200 A Specification CN2-T1 Enironment Indoor / outdoor Normal rated current 200A 12kV 16kA 3 seconds 75kV BIL 13.8kV 21kA 3 seconds 95kV BIL O O Cale earth switch 16kA 3 seconds Cale earth switch 21kA 3 seconds O O Transformer earth switch 3.15kA 3 seconds Mechanism Independent manual Protection & control - circuit reaker CT s dual ratio - 100/50/5A class X CT s ratio - 200/1A class X Oercurrent & earth fault CT operated trip coils Time fuse Link O IDMT oercurrent & earth fault relay - VIP 300 20V-250shunt trip coil Circuit reaker auxiliary switch 1NO 2NC Mechanical ON/OFF Mechanical EARTH/MAIN Neon indication (6.6-13.8kV) O O Auxiliary switch contacts 1NO 2NC Gas pressure indicator Integral cale test facility Operating handle Transformer earth switch 3.15kA 3 seconds Cale (see aailale cale kit accessories) Bottom entry up 300mm 2 1 x 3c Bottom entry up 630mm 2 3 x 1c Key: Standard feature O Optional feature CN2-T6 26 AMTED399086EN.indd
Non-extensile circuit reakers 200 A CN2-T1 CN2-T6 Kit no. Cale kits Tee-off cale ox RMR-F47 Gland plate 1 x 3C O O RMR-A48 Gland plate 3 x 1C O O RMR-A49 Angled gland plates (RMR) O O RMR-A50 Blank Blank aluminium gland plate O O RMR-A52 Brass wiping gland 1 x 3C O O RMR-A10 Brass wiping gland 3 x 1C O O RMR-A11 Tuular gland 1 x 3C O O RMR-A12 Tuular gland 3 x 1C O O RMR-A13 CES5 gland plate 1 x 3C O O RMR-A132 Installation items Set of padlocks - 6 no O O RMR-A18/6 Anti-andal fixings, including tool O O RMR-A19 Foundation olts (not required for transformer mounting) O O RMR-A22 Multicore pilot glands O O RMR-A16 Time limit fuses (set of 2 - specify rating as tale page 115) O RMR-A17 Operational items Operating handle RMR-A23 Neon indication (6.6-13.8kV) RMR-F108 Neon lamp test unit (including lamp) O O RMR-A24 Neon lamp O O RMR-A81 VAP 6 test unit for VIP 300 O RMR-A202 Mechanical interlocks Key free, earth on RMR-F85 Key free, unit off RMR-F86 Transformer earth switch, key free, earth on RMR-F110 N. B. specify lock symol at time of ordering (3 digits max) not aailale with motor mechanisms Order codes 12kV, 16kA, 75kV BIL, 0.35G CN2-T1/16 CN2-T6/16 13.8kV, 21kA, 95kV BIL, 0.8G CN2-T1/21 CN2-T6/21 General arrangement drawing - transformer mounted RMINST-04 Page 76 RMINST-04 Page 76 General arrangement drawing - freestanding RMINST-09 Page 117 RMINST-09 Page 117 Schematic diagram RMSCH-26 Page 106 RMSCH-11 Page 96 Key: Standard feature Factory fitted accessory O Loose accessory, assemled on site AMTED399086EN.indd 27
Non-extensile circuit reaker 200 A CN2-T1 DE60250 Transformer protection up to 3.5MVA Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142 Protection CT s - 200/1A class X Setting range: Oercurrent: 20-200A Earth fault: 2A-160A Shunt trip coil, 20V DC-250V AC Transformer ratings See tale - page 119 Documents Transformer mounted installation drawing ref: RMINST-04 Installation drawing for freestanding unit with tee-off cale ox ref: RMINST-09 Schematic drawing ref: RMSCH-26 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Tee-off earth switch, 3.15kA 3s Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 2 NC Integral cale test facilities Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Tee-off cale ox Glands and plates Interlocks See page 27 for details Order information Code CN2-T1/16 CN2-T1/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 28 AMTED399086EN.indd
Non-extensile circuit reaker 200 A CN2-T6 DE60192 Transformer protection up to 1.5MVA Protection & control - CB Oercurrent and earth fault protection using CT operated trip coils with proision for time fuse links. Protection CT s - 100/50/5A class X Shunt trip coil, 20V DC-250V AC Transformer ratings See tale - page 119 Documents Transformer mounted installation drawing ref: RMINST-04 Installation drawing for freestanding unit with tee-off cale ox ref: RMINST-09 Schematic drawing ref: RMSCH-11 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Transformer earth switch, 3.15kA 3s Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 2 NC Integral cale test facilities Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Tee-off cale ox Glands and plates Interlocks See page 27 for details Order information Code CN2-T6/16 CN2-T6/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 29
Non-extensile switch 630 A Specification SN6-S1 Enironment Indoor / outdoor Normal rated current 630A 13.8kV 21kA 3 seconds 95kV BIL Cale earth switch 21kA 3 seconds Transformer earth switch 3.15kA 3 seconds Mechanism Independent manual Proision for actuator 24V DC Actuator 24V DC O Mechanical ON/OFF Mechanical EARTH/MAIN Neon indication (6.6-13.8kV) O O Auxiliary switch contacts 1NO 2NC Phase and earth fault detection CT s for Easergy 200E O Proision for EFPI O O Integral cale test facility Operating handle Transformer earth switch 3.15kA 3 seconds Cale (see aailale cale kit accessories) Bottom entry up 300mm 2 1 x 3c Bottom entry up 630mm 2 3 x 1c Key: Standard feature O Optional feature SN6-S2 30 AMTED399086EN.indd
Non-extensile switch 630 A SN6-S1 SN6-S2 Kit no. Cale kits Tee-off cale ox RMR-F47 Gland plate 1 x 3C O O RMR-A48 Gland plate 3 x 1C O O RMR-A49 Angled gland plates (RMR) O O RMR-A50 Blank aluminium gland plate O O RMR-A52 Brass wiping gland 1 x 3C O O RMR-A10 Brass wiping gland 3 x 1C O O RMR-A11 Tuular gland 1 x 3C O O RMR-A12 Tuular gland 3 x 1C O O RMR-A13 CES5 gland plate 1 x 3C O O RMR-A132 Installation items Set of padlocks - 6 no O O RMR-A18/6 Anti-andal fixings, including tool O O RMR-A19 Foundation olts (not required for transformer mounting) O O RMR-A22 Multicore pilot glands O O RMR-A16 Operational items Operating handle RMR-A23 Neon indication (6.6-13.8kV) RMR-F108 Neon lamp test unit (including lamp) O O RMR-A24 Neon lamp O O RMR-A81 Actuator 24V DC RMR-F67 Mechanical interlocks Key free, earth on RMR-F85 Key free, unit off RMR-F86 Transformer earth switch, key free, earth on RMR-F110 N. B. specify lock symol at time of ordering (3 digits max) not aailale with motor mechanisms Order codes 13.8kV, 21kA, 95kVBIL, 0.8G SN6-S1/21 SN6-S2/21 General arrangement drawing - transformer mounted RMINST-04 Page 76 RMINST-04 Page 76 General arrangement drawing - freestanding RMINST-09 Page 117 RMINST-09 Page 117 Schematic diagram N/A RMSCH-28 Page 107 Key: Standard feature Factory fitted accessory O Loose accessory, assemled on site AMTED399086EN.indd 31
Non-extensile switch 630 A SN6-S1 DE60193 Switch disconnector Protection & control - CB Non-automatic Documents Installation drawing ref: RMINST-04 Installation drawing for freestanding unit with tee-off cale ox ref: RMINST-09 Schematic drawing ref: N/A Enironment Busars 630A Short time withstand 21kA 3s Normal current rating 630A Normal rated oltage 13.8kV Normal rated BIL 95kV Operating mechanism Independent manual Transformer earth switch, 3.15kA 3s Cale earth switch, 21kA 3s Anti-reflex operating handle Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator Integral cale test facilities Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Tee-off cale ox Neon indication Glands and plates Interlocks See page 31 for details Order information Code SN6-S1/21 Rating 21kA, 13.8kV, 95kV BIL 32 AMTED399086EN.indd
Non-extensile switch 630 A SN6-S2 DE60194 Switch disconnector Protection & control - CB Non-automatic Documents Installation drawing ref: RMINST-04 Installation drawing for freestanding unit with tee-off cale ox ref: RMINST-09 Schematic drawing ref: RMSCH-28 Enironment Busars 630A Short time withstand 21kA 3s Normal current rating 630A Normal rated oltage 13.8kV Normal rated BIL 95kV Operating mechanism Independent manual Proision for actuator, 24V DC Transformer earth switch, 3.15kA 3s Cale earth switch, 21kA 3s Anti-reflex operating handle Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator Auxiliary contacts 1NO 2NC Earth selected auxiliary contact 1NO Integral cale test facilities Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Tee-off cale ox Actuator, 24V DC Neon indication Glands and plates See page 31 for details Order information Code SN6-S2/21 Rating 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 33
Non-extensile metering unit 200 A Specification MU2-M1 MU2-M2 MU2-M3 Enironment Indoor / outdoor Normal rated current 200A 12kV 16kA 1 second 75kV BIL Metering* CT s -50/25/5A 0.5s 7.5VA CT s -100/50/5A 0.5s 10VA CT s -200/100/5A 0.5s 10VA VT s -11kV/110V 0.5 50VA *CT s - 2 phases (R & B), VT s phase to phase. 6.6kV VT s are aailale - contact Schneider Electric Cale (see aailale cale kit accessories) Bottom entry up 300mm 2 1 x 3c O O O Bottom entry up 630mm 2 3 x 1c O O O Key: Standard feature O Optional feature 34 AMTED399086EN.indd
Non-extensile metering unit 200 A MU2-M1 MU2-M2 MU2-M3 Kit no. Cale kits Tee-off cale ox RMR-F47 Gland plate 1 x 3C O O O RMR-A48 Gland plate 3 x 1C O O O RMR-A49 Angled gland plates (RMU) O O O RMR-A51 Blank Blank aluminium gland plate O O O RMR-A52 Brass wiping gland 1 x 3C O O O RMR-A10 Brass wiping gland 3 x 1C O O O RMR-A11 Tuular gland 1 x 3C O O O RMR-A12 Tuular gland 3 x 1C O O O RMR-A13 CES5 gland plate 1 x 3C O O O RMR-A132 Installation items Set of padlocks - XX no O O O RMR-A18/6 Foundation olts (not required for transformer mounting) O O O RMR-A22 Multicore pilot glands O O O RMR-A16 RMU - MU2 installation kit O O O RMR-A350 Freestanding installation kit O O O RMR-A90 Order codes 12kV, 16kA, 75kV BIL, 0.35G MU2-M1/16 MU2-M2/16 MU2-M3/16 General arrangement drawing - transformer mounted RMINST-07/08 Page 78-79 RMINST-07/08 Page 78-79 RMINST-07/08 Page 78-79 Schematic diagram RMSCH-14 Page 97 RMSCH-14 Page 97 RMSCH-14 Page 97 Key: Factory fitted accessory O Loose accessory, assemled on site AMTED399086EN.indd 35
Non-extensile metering unit 200 A MU2-M1 DE60210 Non-extensile metering unit Protection & control - CB N/A Metering transformers Metering CT s R & B phases 50/25/5A 7.5VA class 0.5s Metering VT ph - ph 11kV/110V 50VA class 0.5 Documents Installation drawing ref: RMINST-07/08 Schematic drawing ref: RMSCH-14 Enironment Short time withstand 16kA 1s Normal current rating 200A Normal rated oltage 12kV Normal rated BIL 75kV Direct coupling etween RMU and transformer (optional freestanding cale connection) Cale connection Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Cale ox Glands and plates Installation kits See page 35 for details Order information Code MU2-M1/16 Rating 16kA, 12kV, 75kV BIL 36 AMTED399086EN.indd
Non-extensile metering unit 200 A MU2-M2 DE60210 Non-extensile metering unit Protection & control - CB N/A Metering transformers Metering CT s R & B phases 100/50/5A 10VA class 0.5s Metering VT ph - ph 11kV/110V 50VA class 0.5 Documents Installation drawing ref: RMINST-07/08 Schematic drawing ref: RMSCH-14 Enironment Short time withstand 16kA 1s Normal current rating 200A Normal rated oltage 12kV Normal rated BIL 75kV Direct coupling etween RMU and transformer (optional freestanding cale connection) Cale connection Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Cale ox Glands and plates Installation kits See page 35 for details Order information Code MU2-M2/16 Rating 16kA, 12kV, 75kV BIL AMTED399086EN.indd 37
Non-extensile metering unit 200 A MU2-M3 DE60210 Non-extensile metering unit Protection & control - CB N/A Metering transformers Metering CT s R & B phases 200/100/5A 10VA class 0.5s Metering VT ph - ph 11kV/110V 50VA class 0.5 Documents Installation drawing ref: RMINST-07/08 Schematic drawing ref: RMSCH-14 Enironment Short time withstand 16kA 1s Normal current rating 200A Normal rated oltage 12kV Normal rated BIL 75kV Direct coupling etween RMU and transformer (optional freestanding cale connection) Cale connection Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Cale ox Glands and plates Installation kits See page 35 for details Order information Code MU2-M3/16 Rating 16kA, 12kV, 75kV BIL 38 AMTED399086EN.indd
Extensile circuit reakers 200 A Specification T2 T3 Enironment Indoor / outdoor Busars 630A Circuit reaker normal rated current 200A 12kV 16kA 3 seconds 75kV BIL 13.8kV 21kA 3 seconds 95kV BIL O O O O O O O O O O O O Cale earth switch 16kA 3 seconds Cale earth switch 21kA 3 seconds O O O O O O O O O O O O Mechanism Independent manual Proision for actuator 24V DC Actuator 24V DC O O O O Operating handle Protection system CT s dual ratio - 500/200/1A class x Oercurrent relay - VIP 30 CT s dual ratio - 100/50/5A class X CT ratio - 200/1A class X Oercurrent & earth fault CT operated trip coils Oercurrent & earth fault relay VIP 35 Time fuse link O IDMT oercurrent & earth fault relay - VIP 300 20V-250shunt trip coil Auxiliary switch 1NO 2NC Metering CT s -200/100/5A 0.5s 10VA VT s -13.8kV/110V 0.5 10VA 13.8/110V/110V 0.5 50VA 3P 20VA VT s -11kV/110V 0.5 50VA VT s -6.6kV/110V 0.5 50VA VT s phase - phase, CT s R & B VT s phase - earth, CT s RYB Mechanical ON/OFF Mechanical EARTH/MAIN Cale neon indication (6.6-13.8kV) O O O O O O O O O O O O Auxiliary switch contacts 1NO 2NC Earth selected auxiliary contacts 1NO Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Top entry cales O O O O O O O O O O O O Key: Standard feature O Optional feature T7 T11 T12 T13 T14 T15 T16 T19 T20 T21 AMTED399086EN.indd 39
Extensile circuit reakers 200 A T2 T3 T7 T11 T12 Cale kits Gland plate 1 x 3C O O O O O O O O O O O O RMR-A48 Gland plate 3 x 1C O O O O O O O O O O O O RMR-A49 Angled gland plates (RMR) O O O O O O O O O O O O RMR-A50 Blank aluminium gland plate O O O O O O O O O O O O RMR-A52 Brass wiping gland 1 x 3C O O O O O O O O O O O O RMR-A10 Brass wiping gland 3 x 1C O O O O O O O O O O O O RMR-A11 Tuular gland 1 x 3C O O O O O O O O O O O O RMR-A12 Tuular gland 3 x 1C O O O O O O O O O O O O RMR-A13 CES5 gland plate 1 x 3C O O O O O O O O O O O O RMR-A132 Top entry cales standard RMR-F93 panels Top entry cales MU6 only RMR-F94 Installation items 3 phase usars 630A O O O O O RMR-A14 3 phase usars 630A O O O O O O O RMR-A78 Busar end kit O O O O O O O O O O O O RMR-A15 Set of padlocks - 6 no O O O O O O O O O O O O RMR-A18/6 Foundation olts (not required RMR-A22 for transformer mounting) Multicore pilot glands O O O O O O O O O O O O RMR-A16 Time limit fuses (set of 2 - specify O RMR-A17 rating as tale page 115) Operational items Operating handle RMR-A23 Cale neon indication RMR-F108 (6.6-13.8kV) Neon lamp test unit RMR-A24 (including lamp) Neon lamp O O O O O O O O O O O RMR-A81 VAP 6 test unit for VIP 300 O O O O O O O O O O O RMR-A202 Actuator 24V DC RMR-F67 Polarity conersion kit** RMR-F391 Mechanical interlocks Key free, EARTH ON RMR-F85 Key free, MAIN OFF RMR-F86 N. B. specify lock symol at time of ordering (3 digits max) not aailale with motor mechanisms Key: Standard feature Factory fitted accessory O Loose accessory, assemled on site **Only required when unit is used with RE2c ring main units and automation. T13 T14 T15 T16 T19 T20 T21 Kit no. 40 AMTED399086EN.indd
Extensile circuit reakers 200 A T2 T3 T7 T11 T12 Earth fault passage indication (choose proision kit and an EFPI required if not using Easergy 200E) EFPI proision kit, inside O O O O O O O O O O O O RMR-F30 cale ox Bowden STD EFPI type NB O O O O O O O O O O O O RMR-A277 Bowden LV reset EFPI type NB1 O O O O O O O O O O O O RMR-A278 Bowden LV reset & alarm O O O O O O O O O O O O RMR-A279 type NB2 Bowden RR EFPI and CT O O O O O O O O O O O O RMR-A56 Fundamentals ER FIND O O O O O O O O O O O O RMR-A57 EFPI and CT Ancillary items Tool ox O O O O O O O O O O O O RMR-A80 Order code 12kV, 16kA, 75kV BIL, 0.35G 13.8kV, 21kA, 95kV BIL, 0.8G General arrangement drawing Schematic drawing T2/16 T2/21 RMINST-03 Page 74 RMSCH-07 Page 92 T3/16 T3/21 RMINST-02 Page 73 RMSCH-09 Page 94 T7/16 T7/21 RMINST-03 Page 74 RMSCH-06 Page 91 T11/16 T11/21 RMINST-02 Page 73 RMSCH-09 Page 94 T12/16 T12/21 RMINST-03 Page 74 RMSCH-19 Page 100 T13 T13/16 T13/21 RMINST-02 Page 73 RMSCH-20 Page 101 Key: Standard feature Factory fitted accessory O Loose accessory, assemled on site **Only required when unit is used with RE2c ring main units and automation. T14 T14/16 T14/21 RMINST-02 Page 73 RMSCH-20 Page 101 T15 T15/16 T15/21 RMINST-03 Page 74 RMSCH-07 Page 92 T16 T16/16 T16/21 RMINST-03 Page 74 RMSCH-07 Page 92 T19 N/A T19/21 RMINST-02 Page 73 RMSCH-35 Page 109 T20 T20/16 N/A RMINST-02 Page 73 RMSCH-35 Page 109 T21 N/A T21/21 RMINST-02 Page 73 RMSCH-36 Page 110 Kit no. AMTED399086EN.indd 41
Extensile circuit reaker 200 A T2 DE60251 Feeder protection up to 3.5MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 200/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 20-200A Earth fault: 2-160A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-07 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Gas pressure indicator Integral cale test facilities Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Neon indication Glands and plates Interlocks Operating handle Busar kit Top entry cales See page 40 for details Order information Code T2/16 T2/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 42 AMTED399086EN.indd
Extensile circuit reaker 200 A T7 DE60196 Transformer protection up to 1.5MVA at 11kV Protection & control - CB Oercurrent and earth fault protection using CT operated trip coils with proision for time fuse links. Protection CT s - 100/50/5A class X Shunt trip coil, 20V DC-250V AC Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-06 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Neon indication Glands and plates Interlocks Operating handle Busar kit Top entry cales See page 40 for details Order information Code T7/16 T7/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 43
Extensile circuit reaker 200 A T* DE60252 (Select VT rating and switchgear rating from tale elow). Feeder protection up to 3.5MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 200/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 20-200A Earth fault: 2-160A Metering transformers Metering CT s R & B phases 200/100/5A 10VA class 0.5s Metering VT see elow Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Anti-reflex operating handle Cale earth switch, 16/21kA 3s Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Neon indication Glands and plates Interlocks Operating handle Busar kit Top entry cales See page 40 for details Order code 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL Metering VT information: Phase to phase T3/16 T3/21 T11/16 T11/21 N/A T19/21 Phase to earth 6.6kV/110V 11kV/110V* 13.8kV/110V General arrangement drawing Schematic diagram RMINST-02 Page 73 RMSCH-09 Page 94 RMINST-02 Page 73 RMSCH-09 Page 94 RMINST-02 Page 73 RMSCH-35 Page 109 *Please consult Schneider Electric when ordering units with 95kV BIL oltage Tel: +44(0)113 290 3500 T20/16 N/A RMINST-02 Page 73 RMSCH-35 Page 109 44 AMTED399086EN.indd
Extensile circuit reaker 200 A T12 DE60253 Feeder protection up to 3.5MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 200/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 20-200A Earth fault: 2-160A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-19 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Proision for actuator, 24V DC Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Earth selected auxiliary contact1no Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Actuator, 24V DC Neon indication Glands and plates Interlocks Operating handle Busar kit Top entry cales See page 40 for details Order information Code T12/16 T12/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 45
Extensile circuit reaker 200 A T** DE60254 (Select VT rating and switchgear rating from tale elow). Feeder protection up to 3.5MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 200/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 20-200A Earth fault: 2-160A Metering transformers Metering CT s 200/100/5A 10VA class 0.5s Metering VT see elow Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Proision for actuator, 24V DC Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Earth selected auxiliary contact1no Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Actuator, 24V DC Neon indication Glands and plates Interlocks Operating handle Busar kit Top entry cales See page 40 for details Order code 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL Metering VT information: Phase to phase Phase to earth 6.6kV/110V 11kV/110V* 13.8kV/110V General arrangement drawing Schematic diagram T14/16 T14/21 RMINST-02 Page 73 RMSCH-20 Page 101 N/A T21/21 RMINST-02 Page 73 RMSCH-36 Page 110 *Please consult Schneider Electric when ordering units with 95kV BIL oltage Tel: +44(0)113 290 3500 46 AMTED399086EN.indd
Extensile circuit reaker 200 A T13 DE60254 Feeder protection up to 3.5MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 200/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 20-200A Earth fault: 2-160A Metering transformers Metering CT s 200/100/5A 10VA class 0.5s Metering VT ph - ph 11kV/110V 50VA class 0.5 Documents Installation drawing ref: RMINST-02 Schematic drawing ref: RMSCH-20 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Actuator, 24V DC Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Earth selected auxiliary contact1no Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Neon indication Glands and plates Interlocks Operating handle Busar kit Top entry cales See page 40 for details Order information Code T13/16 T13/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 47
Extensile circuit reaker 200 A T15 DE60251 Feeder protection up to 2.5MVA at 11kV Protection & control - CB Self powered oercurrent relay, VIP 30. Protection CT s - 500/200/1A class X Setting range: 500/1A Oercurrent: 20-200A Setting range: 200/1A Oercurrent: 8-80A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-12 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Gas pressure indicator Integral cale test facilities Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Neon indication Glands and plates Interlocks Operating handle Busar kit Top entry cales See page 40 for details Order information Code T15/16 T15/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 48 AMTED399086EN.indd
Extensile circuit reaker 200 A T16 DE60255 Feeder protection up to 2.5MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 35. Protection CT s - 500/200/1A class X CH30 core alance CT Setting range: 500/1A Oercurrent: 20-200A Earth fault: 25-300A Setting range: 200/1A Oercurrent: 8-80A Earth fault: 10-120A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-13 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 200A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Gas pressure indicator Integral cale test facilities Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Neon indication Glands and plates Interlocks Operating handle Busar kit Top entry cales See page 40 for details Order information Code T16/16 T16/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 49
Extensile circuit reakers 630 A Specification CE6- T4 CE6- T5 Enironment Indoor / outdoor Busars 630A Circuit reaker normal rated current 630A 12kV 16kA 3 seconds 75kV BIL 13.8kV 21kA 3 seconds 95kV BIL O O O O O O O O O Cale earth switch 16kA 3 seconds Cale earth switch 21kA 3 seconds O O O O O O O O O Mechanism Independent manual Proision for actuator 24V DC Actuator 24V DC O O O O Operating handle Protection system CT ratio - 800/1A class X IDMT oercurrent & earth fault relay - VIP 300 20V-250V shunt trip coil Auxiliary switch 1NO 2NC Metering CT s - 400/200/5A 0.5s 10VA VT s - 13.8kV/110V/110V/ 0.5 50VA 3P 20VA VT s - 11V/110V 0.5 50VA VT s - 6.6kV/110V 0.5 50VA VT s - phase - phase, CT s R & B VT s phase - earth, CT s RYB Mechanical ON/OFF Mechanical EARTH/MAIN Cale neon indication (6.6-13.8kV) O O O O O O O O O Auxiliary switch contacts 1NO 2NC CT 600/5A 5VA CLS 1 Yph Ammeter 0-600A Earth selected auxiliary contacts 1NO Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Top entry cales O O O O O O O O O Key: Standard feature O Optional feature CE6- T6 CE6- T8 CE6- T9 CE6- T10 CE6- T22 CE6- T23 CE6- T24 50 AMTED399086EN.indd
Extensile circuit reakers 630 A CE6-T4 CE6-T5 CE6-T6 CE6-T8 CE6-T9 CE6-T10 CE6-T22 CE6-T23 CE6-T24 Kit no. Cale kits Gland plate 1 x 3C O O O O O O O O O RMR-A48 Gland plate 3 x 1C O O O O O O O O O RMR-A49 Angled gland plates (RMR) O O O O O O O O O RMR-A50 Blank aluminium gland plate O O O O O O O O O RMR-A52 Brass wiping gland 1 x 3C O O O O O O O O O RMR-A10 Brass wiping gland 3 x 1C O O O O O O O O O RMR-A11 Tuular gland 1 x 3C O O O O O O O O O RMR-A12 Tuular gland 3 x 1C O O O O O O O O O RMR-A13 CES5 gland plate 1 x 3C O O O O O O O O O RMR-A132 Top entry cales standard panels RMR-F93 Top entry cales MU6 only RMR-F94 Installation items 3 phase usars 630A O O RMR-A14 3 phase usars 630A O O O O O O O RMR-A78 Busar end kit O O O O O O O O O RMR-A15 Set of padlocks - 6 no O O O O O O O O O RMR-A18/6 Foundation olts (not required for RMR-A22 transformer mounting) Multicore pilot glands O O O O O O O O O RMR-A16 Operational items Operating handle RMR-A23 Cale neon indication (6.6-13.8kV) RMR-A108 Neon lamp test unit (including lamp) O O O O O O O O O RMR-A24 Neon lamp O O O O O O O O O RMR-A81 VAP 6 test unit for VIP 300 O O O O O O O O RMR-A202 Actuator 24V DC RMR-F67 Polarity conersion kit** RMR-F391 Mechanical interlocks Key free, EARTH ON RMR-F85 Key free, MAIN OFF RMR-F86 N. B. specify lock symol at time of ordering ( 3 digits max) not aailale with motor mechanisms Earth fault passage indication (choose proision kit and an EFPI required if not using Easergy T200E) EFPI proision kit, inside cale ox O O O O O O O O O RMR-F30 Bowden STD EFPI type NB O O O O O O O O O RMR-A277 Bowden LV reset EFPI type NB1 O O O O O O O O O RMR-A278 Bowden LV reset & alarm type NB2 O O O O O O O O O RMR-A279 Bowden RR EFPI and CT O O O O O O O O O RMR-A56 Fundamentals ER FIND EFPI and CT O O O O O O O O O RMR-A57 Ancillary items Tool ox O O O O O O O O O RMR-A80 Order code 12kV, 16kA, 75kV BIL, 0.35G 13.8kV, 21kA, 95kV BIL, 0.8G General arrangement drawing Schematic drawing CE6- T4/16 CE6- T4/21 RMINST-03 Page 74 RMSCH-08 Page 93 CE6- T5/16 CE6- T5/21 RMINST-02 Page 73 RMSCH-10 Page 95 CE6- T6/16 CE6- T6/21 RMINST-02 Page 73 RMSCH-10 Page 95 CE6- T8/16 CE6- T8/21 RMINST-03 Page 74 RMSCH-23 Page 104 Key: Standard feature Factory fitted accessory O Loose accessory, assemled on site **Only required when unit is used with RE2c ring main units and automation. CE6- T9/16 CE6- T9/21 RMINST-02 Page 73 RMSCH-24 Page 105 CE6- T10/16 CE6- T10/21 RMINST-02 Page 73 RMSCH-24 Page 105 N/A N/A CE6- T24/16 CE6- T22/21 RMINST-02 Page 73 RMSCH-37 Page 111 CE6- T12321 RMINST-02 Page 73 RMSCH-38 Page 112 N/A RMINST-02 Page 73 RMSCH-37 Page 111 AMTED399086EN.indd 51
Extensile circuit reaker 630 A CE6-T4 DE60256 Feeder protection up to 12MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 800/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 80-800A Earth fault: 8-640A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-08 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Ammeter 0-600A CT Y ph - 600/5A class 1.0, 5VA Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Neon indication Glands and plates Interlocks Busar kit Top entry cales See page 51 for details Order information Code CE6-T4/16 CE6-T4/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 52 AMTED399086EN.indd
Extensile circuit reaker 630 A CE6-T* DE60197 (Select VT rating and switchgear rating from tale elow). Feeder protection up to 12MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 800/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 80-800A Earth fault: 8-640A Metering transformers Metering CT s 400/200/5A 10VA class 0.5s Metering VT see elow Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Ammeter 0-600A CT Y ph - 600/5A class 1.0, 5VA Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Actuator, 24V DC Neon indication Glands and plates Interlocks Busar kit Top entry cales See page 51 for details Order code 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL Metering VT information: Phase to phase CE6-T5/16 CE6-T5/21 CE6-T6/16 CE6-T6/21 N/A CE6-T22/21 Phase to earth 6.6kV/110V 11kV/110V* 13.8kV/110V General arrangement drawing Schematic diagram RMINST-02 Page 73 RMSCH-10 Page 95 RMINST-02 Page 73 RMSCH-10 Page 95 RMINST-02 Page 73 RMSCH-37 Page 111 *Please consult Schneider Electric when ordering units with 95kV BIL oltage Tel: +44(0)113 290 3500 CE6-T24/16 N/A RMINST-02 Page 73 RMSCH-37 Page 111 AMTED399086EN.indd 53
Extensile circuit reaker 630 A CE6-T8 DE60257 Feeder protection up to 12MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 800/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 80-800A Earth fault: 8-640A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-23 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Proision for actuator, 24V DC Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Earth selected auxiliary contact1no Ammeter 0-600A CT Y ph - 600/5A class 1.0, 5VA Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Actuator, 24V DC Neon indication Glands and plates Interlocks Busar kit Top entry cales See page 51 for details Order information Code CE6-T8/16 CE6-T8/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 54 AMTED399086EN.indd
Extensile circuit reaker 630 A CE6-T** DE60199 (Select VT rating and switchgear rating from tale elow). Feeder protection up to 12MVA at 11kV Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 800/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 80-800A Earth fault: 8-640A Metering transformers Metering CT s 400/200/5A 10VA class 0.5s Metering VT see elow Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A Normal rated oltage 12/13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Cale earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Earth selected auxiliary contacts Ammeter 0-600A CT Y ph- 600/5A class 1.0, 5VA Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Neon indication Glands and plates Interlocks Busar kit Top entry cales See page 51 for details Order code 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL Metering VT information: Phase to phase Phase to earth 6.6kV/110V 11kV/110V* 13.8kV/110V General arrangement drawing Schematic diagram CE6-T9/16 CE6-T9/21 RMINST-02 Page 73 RMSCH-24 Page 105 CE6-T10/16 CE6-T10/21 RMINST-02 Page 73 RMSCH-24 Page 105 *Please consult Schneider Electric when ordering units with 95kV BIL oltage Tel: +44(0)113 290 3500 N/A CE6-T23/21 RMINST-02 Page 73 RMSCH-38 Page 112 AMTED399086EN.indd 55
Extensile switches 630 A Specification SE6-S1 SE6-S2 SE6-E1 Enironment Indoor / outdoor Busars 630A Switch normal rated current 630A 13.8kV 21kA 3 seconds 95kV BIL Cale earth switch 21kA 3 seconds Mechanism Independent manual Proision for actuator 24V DC Actuator 24V DC O Operating handle Mechanical ON/OFF Mechanical EARTH/MAIN Cale neon indication (6.6-13.8kV) Busar neon indication (6.6-13.8kV) Auxiliary switch contacts1no 1 NC Phase and earth fault detection CT s for Easergy T200E O EFPI proision only CT inside ox O O Gas pressure indicator Integral cale test facility Integral test facility RH/LH usar earthing Cale (see aailale cale kit accessories) Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Top entry cales O O Key: Standard feature Factory fitted accessory O Loose accessory, assemled on site 56 AMTED399086EN.indd
Extensile switches 630 A SE6-S1 SE6-S2 SE6-E1 Kit no. Cale kits Gland plate 1 x 3C O O RMR-A48 Gland plate 3 x 1C O O RMR-A49 Angled gland plates (RMR) O O RMR-A50 Blank aluminium gland plate O O RMR-A52 Brass wiping gland 1 x 3C O O RMR-A10 Brass wiping gland 3 x 1C O O RMR-A11 Tuular gland 1 x 3C O O RMR-A12 Tuular gland 3 x 1C O O RMR-A13 CES5 gland plate 1 x 3C O O RMR-A132 Top entry cales RMR-F93 Installation items 3 phase usars 630A O O RMR-A14 Set of padlocks - 6 no O O O RMR-A18/6 Busar end kit (1 end kit required per switchoard) O O O RMR-A15 Foundation olts (not required for transformer mounting) RMR-A22 Multicore pilot glands O RMR-A16 Operational items Operating handle RMR-A23 Cale neon indication (6.6-13.8kV) RMR-F108 Cale and usar neon indication (6.6-13.8kV) RMR-F92 Neon lamp test unit (including lamp) O O RMR-A24 Neon lamp O O RMR-A81 Actuator 24V DC RMR-F67 Polarity conersion kit* RMR-F391 Mechanical interlocks Key free, earth ON RMR-F85 Key free, main OFF RMR-F86 N. B. specify lock symol at time of ordering ( 3 digits max) not aailale with motor mechanisms EFPI proision kit, inside cale ox O O RMR-F30 Bowden STD EFPI NB O O RMR-A277 Bowden LV reset EFPI type NB1 O O RMR-A278 Bowden LV reset & alarm type NB2 O O RMR-A279 Bowden RR EFPI and CT O O RMR-A56 Fundamentals ER FIND EFPI and CT O O RMR-A57 Ancillary items Tool ox O O O RMR-A80 Order code 13.8kV, 21kA, 95kV BIL, 0.8G SE6-S1/21 SE6-S2/21 SE6-E1/21 General arrangement drawing RMINST-03 Page 74 RMINST-03 Page 74 Schematic drawing N/A RMSCH-29 Page 108 Key: Standard feature Factory fitted accessory O Loose accessory, assemled on site **Only required when unit is used with RE2c ring main units and automation. RMINST-03 Page 74 N/A AMTED399086EN.indd 57
Extensile switch 630 A SE6-S1 DE60201 Switch disconnector Protection & control - CB Non-automatic Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-N/A Enironment Busars 630A Short time withstand 21kA 3s Normal current rating 630A Normal rated oltage 13.8kV Normal rated BIL 95kV Operating mechanism Independent manual Cale earth switch, 21kA 3s Anti-reflex operating handles Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Neon indication Glands and plates Interlocks Busar kit Top entry cales See page 57 for details Order information Code SE6-S1/21 Rating 21kA, 13.8kV, 95 kvbil 58 AMTED399086EN.indd
Extensile switch 630 A SE6-S2 DE60202 Switch disconnector Protection & control - CB Non-automatic Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-29 Enironment Busars 630A Short time withstand 21kA 3s Normal current rating 630A Normal rated oltage 13.8kV Normal rated BIL 95kV Operating mechanism Independent manual Proision for actuator, 24V DC Cale earth switch, 21kA 3s Anti-reflex operating handle Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Earth selected auxiliary contact 1NO Gas pressure indicator Integral cale test facility Cale Bottom entry up to 300mm 2 1 x 3c Bottom entry up to 630mm 2 3 x 1c Actuator, 24V DC Neon indication Glands and plates Interlocks Busar kit Top entry cales See page 57 for details Order information Code SE6-S2/21 Rating 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 59
Extensile switch 630 A SE6-E1 DE60203 Busar earthing switch Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-N/A Enironment Busars 630A Short time withstand 21kA 3s Normal current rating 630A Normal rated oltage 13.8kV Normal rated BIL 95kV Operating mechanism Independent manual Cale earth switch, 21kA 3s Anti-reflex operating handle Mechanical earth/main indicator Gas pressure indicator N/A Cale N/A Interlocks Busar kit See page 57 for details Order information Code SE6-E1/21 Rating 21kA, 13.8kV, 95kV BIL 60 AMTED399086EN.indd
Extensile us-section 630 A Specification SE6-B1 CE6-B3 CE6-B5 Enironment Indoor / outdoor Busars 630A Circuit reaker normal rated current 630A Switch normal rated current 630A 12kV 16kA 3 seconds 75kV BIL 13.8kV 21kA 3 seconds 95kV BIL O O RH usar earth switch 16kA 3 seconds RH usar earth switch 21kA 3 seconds O O Mechanism Independent manual Proision for actuator 24V DC Actuator 24V DC O Operating handle Protection system CT ratio - 800/1A class X IDMT oercurrent & earth fault relay - VIP 300 20-250 V shunt trip coil Auxiliary switch1no 2 NC Metering CT s - 400/200/5A 0.5s 10VA VT s - 11kA/110V 0.5 50VA VT s phase - phase, CT s R & B Mechanical ON/OFF Mechanical EARTH/MAIN Earth selected auxiliary contact1no RH usar neon indication O O O Auxiliary switch contacts1no 2NC CT 600/5A 5VA CLS 1 Y phase Ammeter 0-600A Gas pressure indicator Integral test facility RH usar earthing LH usar earthing ( using SE6-E1) O O O Key: Standard feature O Optional feature AMTED399086EN.indd 61
Extensile us-section 630 A SE6-B1 CE6-B3 CE6-B5 Kit no. Installation items 3 phase usars 630A RMR-A14 3 phase usars 630A (Joggle metering) RMR-A79 3 phase usars 630A doule width (metering) RMR-A78 Set of padlocks - XX no O O O RMR-A18/6 Busar end kit (1 end kit required per switchoard) O O O RMR-A15 Foundation olts (not required for transformer mounting) RMR-A22 Multicore pilot glands O O RMR-A16 Operational items Operating handle RMR-A23 LH and RH usar neon indication RMR-F92 Neon lamp test unit (including lamp) O O RMR-A24 Neon lamp O O O RMR-A81 VAP6 test unit for VIP 300 O O RMR-A202 Actuator 24V DC RMR-F67 Polarity conersion kit* RMR-F391 Mechanical interlocks Key free, earth ON RMR-F85 Key free, main OFF RMR-F86 N. B. specify lock symol at time of ordering ( 3 digits max) not aailale with motor mechanisms Ancillary items Tool ox O O O RMR-A80 Order code 12kV, 16kA, 75kV BIL, 0.35G N/A CE6-B3/16 CE6-B5/16 13.8kV, 21kA, 95kV BIL, 0.8G SE6-B1/21 CE6-B3/21 CE6-B5/21 General arrangement drawing RMINST-01 Page 72 RMINST-01 Page 72 Schematic drawing N/A RMSCH-21 Page 102 Key: Standard feature Factory fitted accessory O Loose accessory, assemled on site **Only required when unit is used with RE2c ring main units and automation. RMINST-01 Page 72 RMSCH-22 Page 103 62 AMTED399086EN.indd
Extensile us-section 630 A SE6-B1 DE60204 Bus-section disconnector Protection & control Non-automatic Documents Installation drawing ref: RMINST-01 Schematic drawing ref: N/A Enironment Busars 630A Short time withstand 21kA 3s Normal current rating 630A Normal rated oltage 13.8kV Normal rated BIL 95kV Operating mechanism Independent manual RH usar earth switch, 21kA 3s Anti-reflex operating handle Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator Integral RH usar test facility Cale N/A Neon indication Interlocks Busars See page 62 for details Order information Code SE6-B1/21 Rating 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 63
Extensile us-section 630 A CE6-B3 DE60258 Bus-section circuit reaker Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 800/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 80-800A Earth fault: 8-640A Metering transformers Metering CT s 400/200/5A 10VA class 0.5s Metering VT ph-ph 11kV/110V 50VA class 0.5 Documents Installation drawing ref: RMINST-01 Schematic drawing ref: RMSCH-21 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A Normal rated oltage 13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual RH usar earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Ammeter 0-600A CT Y ph- 600/5A class 1.0 5VA Gas pressure indicator Integral RH usar test facility Cale N/A Neon indication Interlocks Busars See page 62 for details Order information Code CE6-B3/16 CE6-B3/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL 64 AMTED399086EN.indd
Extensile us-section 630 A CE6-B5 DE60259 Bus-section circuit reaker Protection & control - CB Self powered IDMT oercurrent and earth fault relay, VIP 300. In accordance with IEC 60255 and BS142. Protection CT s - 800/1A class X Shunt trip coil, 20V DC-250V AC Setting range: Oercurrent: 80-800A Earth fault: 8-640A Metering transformers Metering CT s 400/200/5A 10VA class 0.5s Metering VT ph-ph 11kV/110V 50VA class 0.5 Documents Installation drawing ref: RMINST-01 Schematic drawing ref: RMSCH-22 Enironment Busars 630A Short time withstand 16/21kA 3s Normal current rating 630A Normal rated oltage 13.8kV Normal rated BIL 75/95kV Operating mechanism Independent manual Proision for actuator, 24V DC RH usar earth switch, 16/21kA 3s Anti-reflex operating handle Mechanical tripped on fault flag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Earth selected auxiliary contacts1no Ammeter 0-600A CT Y ph- 600/5A class 1.0 5VA Gas pressure indicator Integral RH usar test facility Cale N/A Actuator, 24V DC Neon indication Interlocks Busars See page 62 for details Order information Code CE6-B5/16 CE6-B5/21 Rating 16kA, 12kV, 75kV BIL 21kA, 13.8kV, 95kV BIL AMTED399086EN.indd 65
Telecontrol units Easergy T200E - Specification Easergy T200 EO1 single function Easergy T200 EO2 2 functions Enironment Indoor / outdoor Communication RS232C using Westinghouse WISP+ protocol or RS232/RS485 - Modus protocol Freestanding/wall mounted/ switchgear mounted Remoale radio racket ( no radio supplied) Inputs to cainet Switch open - per switch Switch closed - per switch Earth selector earth/mains - per switch 1 spare - per switch Control output to switchgear To switch - Open switch - Close switch - Reset external FPI Output to SCADA - Switch open - Switch closed - Earth selector earth/main - Fault passage indication - phase and/or earth fault From cainet - Local/remote failure - Mains/equipment failure - Battery and charger alarms Local control Push utton open/close switch Local/remote selector Reset/test integral FPI Power restart Local indication Mains present Battery fault Internal supplies on Switch status - open/closed FPI operated Local/remote mode selected Equipment fault (watchdog) Battery and charger Power supply 230V AC Telecomms equipment - 12V DC Control unit - 12V DC Power supply 230V AC Switchgear 24V AC 3 x 7AH sealed lead acid 20 degrees C, 3 hours after loss of supply 5 c/o switch operations Key: Standard feature O Optional feature Easergy T200 EO4 4 functions 66 AMTED399086EN.indd
Telecontrol units Easergy T200-E01M DE60191 Telecontrol unit - single switch control Local indication Mains failure, attery fault, internal supplies on, Switch status - open/closed, FPI operated, local/remote mode selected, equipment fault (Watchdog) Inputs to cainet Switch open Switch closed *Earth selector earth/mains 3 spare Control outputs to switchgear To switch Open switch Close switch Reset FPI Local control Push utton open/close switch Local/remote selector Reset/test integral FPI Optional features Integral phase and earth fault passage indicator 3 phase RMS current measurement Wall mounted/freestanding Documents Installation drawing ref: RMINST-11 Schematic drawing ref: RMSCH-17 Enironment Communication RS232C using Westinghouse WISP+ protocol or RS232/RS485 - Modus protocol Switchgear mounted remoale radio racket ( no radio/modem supplied) Outputs to SCADA Switch open Switch closed Earth selector earth/main Fault passage indication - phase and/or earth fault From cainet Local/remote mode Mains/equipment failure other configurale alarms Batteries and charger Telecomms equipment - 12V DC Control unit - 12V DC Switchgear - 24V DC 3 x 7Ah sealed lead acid Power supply 230V AC +/- 15% 50Hz Autonomy 20 C 5 hours after loss of supply 5 C/O switch operations Deep discharge protection Order information T200-EO1M AMTED399086EN.indd 67
Telecontrol units Easergy T200-E04M DE60195 Telecontrol unit - up to 4 switch control Local indication Mains failure, attery fault, internal supplies on, Switch status - open/closed, FPI operated, local/remote mode selected, equipment fault (Watchdog) Inputs to cainet Switch open Switch closed *Earth selector earth/mains 3 spare Control outputs to switchgear To switch Open switch Close switch Reset FPI Local control Push utton open/close switch Local/remote selector Reset/test integral FPI Optional features Integral phase and earth fault passage indicator 3 phase RMS current measurement Wall mounted/freestanding Documents Installation drawing ref: RMINST-11 Schematic drawing ref: RMSCH-17 Enironment Dimensions 480 x 370 x 280mm Communication RS232C using Westinghouse WISP+ protocol or RS232/RS485 - Modus protocol Switchgear mounted remoale radio racket ( no radio/modem supplied) Outputs to SCADA Switch open Switch closed Earth selector earth/main Fault passage indication - phase and/or earth fault From cainet Local/remote mode Mains/equipment failure other configurale alarms Batteries and charger Telecomms equipment - 12V DC Control unit - 12V DC Switchgear - 24V DC 3 x 7Ah sealed lead acid Power supply 230V AC +/- 15% 50Hz Autonomy 20 C 5 hours after loss of supply 5 C/O switch operations Deep discharge protection Order information T200-EO4M 68 AMTED399086EN.indd