CYTOFLEX FLOW CYTOMETER BENCHTOP CYTOMETRY WITHOUT COMPROMISES

Similar documents
Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

FlowSight. Flow cytometry with vision

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Introduction to flow cytometry

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

APPLICATION INFORMATION

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

Boundary-breaking acoustic focusing cytometry

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois

Immunophenotyping peripheral blood cells

CyAn : 11 Parameter Desktop Flow Cytometer

BD FACSDiva TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Introduction to Flow Cytometry

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

COMPENSATION MIT Flow Cytometry Core Facility

Introduction to Flow Cytometry

Cell Cycle Tutorial. Contents

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Uses of Flow Cytometry

BD FACSComp Software Tutorial

Standardization, Calibration and Quality Control

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

Standard Operating Procedure

Easy to use. Compact. Flexible. Sorting Chip

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

Compensation in Flow Cytometry

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

Fluorescence Compensation. Jennifer Wilshire, PhD

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

Three Rules for Compensation Controls

1. Instrument Layout pg Summit Overview pg Data Storage and Data Files pgs Saving Data pg Start Up pg 8

FACS Laboratory. BD LSRs Operator Training. Training Guide.

These particles have something in common

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit G June Beckman Coulter, Inc N. Harbor Blvd. Fullerton, CA 92835

HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

Cytell Cell Imaging System

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Principles of Flowcytometry

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

Science is hard. Flow cytometry should be easy.

Below is a list of things you should be aware of before you schedule your sort.

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

CyFlow Space Your flexible flow cytometer

Compensation Controls Data Visualization Panel Development Gating Quantum Dots

FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences

Introduction to Flow Cytometry:

Setting up and calibration of a flow cytometer for multicolor immunophenotyping

Zecotek S Light Projection Network Marketing

Attune NxT Acoustic Focusing Cytometer

Analyzer Experiment setup guide for LSRII and Canto s

DELPHI 27 V 2016 CYTOMETRY STRATEGIES IN THE DIAGNOSIS OF HEMATOLOGICAL DISEASES

BD FACSCanto Flow Cytometer. Efficient Easy Powerful

Hoechst HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, )

FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed

EdU Flow Cytometry Kit. User Manual

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

How to operate the BD FACSCanto flow cytometer

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

Automation of Cell Staining Technical Information Bulletin

Compensation: An Instrumental Perspective

Becton-Dickinson FACSCalibur Flow Cytometer Instructions

ArC Amine Reactive Compensation Bead Kit

FACSCanto RUO Special Order QUICK REFERENCE GUIDE

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

UCHC Guide to CellQuest Pro. FACS Calibur instruments

Attune Acoustic Focusing Cytometer

LSR II Users Guide Stanford Shared FACS Facility 06/10/13

GETTING STARTED. 6. Click the New Specimen icon.

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

International Beryllium Conference, Montreal, Canada March 10, 2005

--Verity Software House, ModFit for Proliferation offers online tutorials

A Basic Guide. Institute of Medical Biology, University of Southern Denmark. Ungated Gate 1 (= R1) Gate 4 (=R4) Gate3 (=R3) Gate 2 (= R2) R3 R4

BD FACSVerse. Simply brilliant

flow cytometry reinvented

FlowJo Basic Tutorial

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Fluorescent Array Imaging Reader

Compensation Basics - Bagwell. Compensation Basics. C. Bruce Bagwell MD, Ph.D. Verity Software House, Inc.

CFSE Cell Division Assay Kit

a Beckman Coulter Life Sciences: White Paper

Cell Discovery 360: Explore more possibilities.

LIVE/DEAD Fixable Dead Cell Stain Kits

Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit

Institut für Experimentelle Immunologie und Bildgebung

Transcription:

CYTOFLEX FLOW CYTOMETER BENCHTOP CYTOMETRY WITHOUT COMPROMISES

BENCHTOP CYTOMETRY WITHOUT COMPROMISES The CytoFLEX Flow Cytometer has a unique flow cell design and integrated optics. The innovative Wavelength Division Multiplexing (WDM) detection module includes solid-state, high efficiency, low-noise detectors for excellent performance. The revolutionary system presents optimal excitation and emission, minimizing light loss and maximizing sensitivity. This means that you can easily detect dim populations in your sample. And all with an easy to use software interface. At 40.6 by 40.5 by 33 cm (H by W by D) and less than 22 kg, the compact size and light weight mean that you can take the instrument where it is needed, including inside a laminar flow or biosafety hood. The CytoFLEX Flow Cytometer s superior sensitivity and resolution throughout all configurations give it the edge over other cytometry systems four times its size. Independent Researcher Performance Assessments The CytoFLEX compares very well with all the best instruments out there. It definitely beats every instrument I own in the FITC, PE, PECy7, and APC channels. Ryan Duggan, UC Flow Core Lab Director QNORM RESOLUTION TEST RESULTS. This metric measures the number of bound antibodies that can be resolved from unstained lymphocytes with lower numbers equaling better low-end resolution. # of Antibodies that can be resolved from autotfluorescence 16000 14000 12000 10000 8000 6000 4000 2000 0 CytoFLEX qnorm Resolution Test Lower values = better resolution FITC PE PC7 APC PB Standard Channel Capable of Detecting the Fluorophore Every Event Matters

100 nm 160 nm 200 nm 240 nm 300 nm 500 nm 900 nm The CytoFLEX is the first flow cytometer with an acceptable noise range on which we can clearly demonstrate detection of extracellular vesicles down to a size of 150nm. The potential to combine small particle analysis with the detection of up to 13 additional fluorescence parameters makes this cytometer an outstanding instrument for extracellular vesicle detection. Andreas Spittler, MD, Associate Professor for Pathophysiology, Medical University of Vienna, Core Facility Flow Cytometry & Department of Surgery, Research Laboratories Contact your local representative for a detailed application note: Set-Up of the CytoFLEX for Extracellular Vesicle Measurement. GIGAMIX BEAD ANALYSIS. The Gigamix solution is a mixture of fluorescent Megamix-Plus SSC and Megamix-Plus FSC beads (BioCytex a Stago group company, Marseille, France) which have different sizes, 100, 160, 200, 240, 300, 500, 900 nm (red, purple, orange, blue, green, olive, and fuchsia, respectively). Beads were measured at flow rates of 10, 60 and 120 μl/min. The population of the 100 nm beads is very small and within the range of noise. Increasing the flow rate makes the 100 nm beads more visible. The visibility of all other peaks was also improved indicating that by increasing the flow rate the background noise is not also increased. MFI 450,000 400,000 350,000 300,000 250,000 200,000 150,000 100,000 50,000 0 Linearity Dimly-Responsive Channels Violet610 Violet780 APC-A700 APC-A750 PC7 Violet660 APC 1,000 1,500 2,000 2,500 3,000 Gain Setting - Voltage Applied LINEARITY OF DIMLY RESPONSIVE CHANNELS. Using 8-peak beads, the third brightest peak s median intensity was measured at every gain and plotted versus MFI. Linearity is certainly a great asset of the CytoFLEX. It is truly impressive as all the channels displayed an almost perfect linearity. The minimum R-squared value achieved was 0.9998 which is exceptional. Loïc Tauzin, Valerie Glutz and Miguel Garcia, Ecole Polytechnique Federale De Lausanne Flow Cytometry Core Facility

Laser and Fluorescent Channel Choices The system can be fully configured with up to three lasers and 13 fluorescent channels for 15 analysis parameters or purchased as a one laser 4 color system and upgraded later as needed. Optimal Performance upon Installation The advanced optical system is alignment free. The laser delays are automatically adjusted by the daily QC system, if required. Provides 7 decades of tunable dynamic range <30 MESF FITC <10 MESF PE 200nm particle detection Excitation 488nm 638nm Fluorescence Channels 525/40 BP Fluorochromes FITC, Alexa Fluor 488, CFSE, Fluo-3 585/42 BP PE, PI 610/20 BP 690/50 BP ECD, PE-Texas Red, PE-CF594, PI PC5, PC5.5, PerCP, PerCP-Cy5.5, PI 780/60 BP PC7 660/20 BP 712/25 BP 780/60 BP APC, Alexa Fluor 647, efluor 660 APC-Alexa Fluor 700, Alexa Fluor 700 APC-Alexa Fluor 750, APC-Cy7, APC-H7, APC-eFluor 780 405nm 450/45 BP 525/40 BP 610/20 BP 660/20 BP 780/60 BP Pacific Blue, V450, efluor 450, BV421 Krome Orange, AmCyan, V500, BV510 Violet610, BV605, Qdot 605 Violet660, BV650, Qdot 655 Violet780, BV785, Qdot 800 Every Event Matters

Conserve Precious Samples and Maximize Data Collected Use sample volumes as low as 10µL. User adjustable flow rate from 10-240 µl/minute, selectable at three increments. Detect up to 30,000 events per second with 15 parameters. For higher throughput applications, an optional plate loader module can save hands on time. CytoFLEX Plate Loader option can analyze a 96-well plate in as little as 32 minutes. Switch between single tube and plate acquisition in 5 minutes. Easy virtual plate layout setup with customizable wash and mix cycles Define multiple experiments on a single plate Compatible with flat-bottom, U- and V-bottom standard plates Rainbow 8-peak Bead Data 600 600 FITC-A PE-A ECD-A PC5.5-A PC7-A 600 APC-A APC-A700-A APC-A750-A 10 2 10 3 10 4 10 5 10 6 10 2 10 3 10 4 10 5 10 6 10 3 10 4 10 5 10 6 PB450-A KO525-A Violet610-A Violet660-A Violet780-A Exceptional instrument sensitivity: baseline resolution of all peaks even in violet and far red channels detectors using SPHERO Rainbow 8-peak beads.

FOCUS ON THE SCIENCE The CytoFLEX Flow Cytometer provides the performance you need in an easy to use system allowing you to focus on the science, not the instrumentation. The system can be configured for the needs of your laboratory, whether it is routine low complexity analysis, high complexity analysis, or analysis that pushes the boundaries for flow cytometry. CELL PROLIFERATION ANALYSIS. Combining BrdU incorporation to assess actively proliferating cells and 7-AAD to measure the proportion of live cells is an effective combination for assessing key population characteristics. The CytoFLEX Flow Cytometer is ideal for these routine analyses. Cell Proliferation Analysis by BrdU Incorporation T CELL SUBSET ANALYSIS. The complexity of heterogeneous cell population analysis continues to increase as more markers are needed to differentiate functional cell sub populations. With up to 13 channels for fluorescent detection, the CytoFLEX Flow Cytometer has the capabilities needed to meet the increased immunophenotyping demands. Memory T Cell Immunophenotyping Cell Cycle Analysis of proliferating human peripheral blood mononuclear cells by BrdU incorporation and 7-AAD staining. Analyses of T cell subsets based on the differential expression of surface molecules related to cell function, differentiation, or activation have evolved. As a result, T cell analysis requires a multitude of markers to capture the various populations. Combining the CytoFLEX Flow Cytometer with the 13 color DuraClone tube presented here, allows for the identification of most T cell memory subpopulations discriminated by surface expression makers. Application note available for experimental details Every Event Matters

OPTIMAL RESOLUTION FOR LOW EXPRESSED ANTIGENS. Low expressed antigens and low abundance cell types are pushing the boundaries of flow cytometry. The CytoFLEX Flow Cytometer has the sensitivity and resolution capabilities to identify populations with these characteristics. Cytometric Detection of Regulatory T Cells Human PBMCs Mouse Spleen Regulatory T cells characterized by low levels of expression were easily identified. Microparticle Detection Using Violet Side Scatter Bead based small particles were detected using forward scatter and VSSC. Data provided by Dr. Huang Yijun, Sun Yat-Sen University, School of Medicine, Guangzhou, China. Application note available on optimal nanoparticle detection MICROPARTICLE DETECTION. The boundaries for flow cytometry are also being pushed by the need to measure and evaluate characteristics of smaller particles. Several fundamental capabilities of flow cytometry make this an attractive platform for extracellular vesicles, ability to detect large numbers of events, and discriminate rare events, while collecting information on phenotypic expression. The CytoFLEX Flow Cytometer has the resolution to detect particles down to 200 nm while also collecting information in the fluorescent channels. CytExpert Acquisition and Analysis Software Novice to experienced cytometrists can not only learn and operate the system quickly but can confidently set up experiment based protocols and export publication quality data. Includes some innovations to make flow cytometry data collection easier than ever. Compensation Library: Store a repository of compensation spillover values of dyes in a library to easily determine the correct compensation matrix with new gain settings. Auto Threshold: Easily find target population. No need to worry about the threshold setting while adjusting gains when this function is enabled. Axis Pan: An ideal tool for visualization across a high dynamic range axis. You can easily pan across the axis range to search if there is important data out of range. A tool for gold panning

Choose Beckman Coulter for Benchmark Expertise and Innovation For over 80 years Beckman Coulter has driven innovation. We remain committed to shaping flow cytometry technology to fit seamlessly into your lab s workflow and to provide an optimal user experience. When you choose a Beckman Coulter instrument you receive the highest level of expertise, innovation, and quality assurance. Contact your local Beckman Coulter sales representative. beckmancoulter.com 2015 Beckman Coulter Life Sciences. All rights reserved. CytoFLEX is for research use only. Class 1 Laser Product. Not for use in diagnostic purposes. CytoFLEX and CytExpert are trademarks of Xitogen Technologies (Suzhou), Inc., a Beckman Coulter company. Beckman Coulter, the stylized logo and fast track to success are trademarks of Beckman Coulter, Inc. Beckman Coulter and the stylized logo are registered in the USPTO.All other trademarks are the property of their respective owners. For Beckman Coulter s worldwide office locations and phone numbers, please visit Contact Us at beckmancoulter.com FLOW-553SB08.15-D