1 a Beckman Coulter Life Sciences: White Paper Beckman Coulter Gallios* Flow Cytometer and the Detection of Micro-particles Authors: Affiliation: T. Matt Holl, PhD; Karen Carr, PhD; John Mattachini; Frank Day Beckman Coulter, Inc. - Flow Cytometry
2 Beckman Coulter Gallios* Flow Cytometer and the Detection of Micro-particles PRINCIPLE OF THE TECHNIQUE Background: Flow cytometry is routinely being used as a solution to detect small (~1-3 μm) particles and microparticles (<1.0 μm). Using our newly innovated FSC detection system, the Gallios flow cytometer permits a wide dynamic range of small and micro-particle detection. The Gallios analyzer permits high sensitivity of fluorescence detection; therefore, sub-micron particle detection can be further enhanced using a fluorescence-based discriminator. Together, the Gallios is a superb platform for the identification and characterization of biological small and micro-particles. This technical publication is designed as a resource for investigators performing small and micro-particle research on the Gallios platform. RESEARCH APPLICATIONS Introduction: Micro-particles (MP) are derived from outward protrusion and fission of plasma-membrane which is then released into the extracellular environment. Multiple signaling pathways (e.g. mobilization of intracellular calcium) must be activated and the coordinated reorganization of the cell s cytoskeleton must occur for micro-particles to form. The formation and release of micro-particles often results in the exposure of phosphatidylserine (PS), a phospholipid normally located on the cytosolic side of cell membranes, to the surface of the vesicle by an enzyme called flippase [1]. This PS exposure has been well defined by studying cells as they undergo apoptosis [1] and is visualized by reactivity with fluorochrome-labeled AnnexinV reagents. The origin of micro-particle populations can be determined as the vesicle membrane is enriched with specific lipids and proteins reflecting their cellular progenitor [2]. * The Gallios is for research use only; not for use in diagnostic procedures. BECKMAN COULTER WHITE PAPER 2
3 Recently, biological micro-particles have been the focus of basic science and clinical research studies [3, 4]. Some areas of focus where active micro-particle investigation is currently ongoing include: thrombosis/ thromboembolism [5], Sickle cell anemia crisis [6], heart failure [7] and oncology [8]. However, a consensus on standardization by investigators is early in its development and heavily debated. These discussions to address standardization are often centered on i) flow cytometry instrumentation hardware/software, ii) particle size estimation protocols and iii) sample handling/preparation techniques. Fortunately, there have been strong attempts to establish and characterize standardization protocols that give investigators an initial reference point [10]. As with most early scientific efforts, these guidelines are sure to be refined as instrumentation and protocols become more sensitive and refined [9]. Until recently, many flow cytometry instruments lacked the sensitivity to detect particles below the 1μm threshold - a value commonly agreed upon to be the high end of micro-particle size. With an innovated Forward Angle Light Scatter detector, the Gallios flow cytometer has been optimized to detect micro-particles using strategically chosen FSC detector modes. The Narrow mode (N = 1-8 ) is ideal for larger cells, the Wide mode (W = 1-19 ) is optimized for smaller cells, and the Enhanced Wide mode (W2 = 1-19 with log amplification) allows the amplification of wide angle light scatter independent of low angle light scatter. As we will demonstrate here, using the Gallios light scatter W2 angle mode, researchers can greatly increase the resolution of micro-particle detection from background noise and similarly sized particles. PROTOCOL Standard Procedure: Ensuring Instrumentation Alignment and Sensitivity SPHERO Rainbow Calibration Particles (Spherotech, Inc. Cat# RCP-60-5) (6-peak) were used according to manufacturer s recommended protocol. Gallios instrument voltages were set so that the first peak was fully visible on scale to accurately determine the staining index (SI). SI are useful measures of population discrimination [11, 12] as they provide intensity values normalized by the width of the background population (MFI=Mean Fluorescence Intensity, SD = Standard Deviation): SI= (MFI positive MFI background ) / (2 xsd background ). Flow-Check Pro beads (Cat. No: A69183) were used to ensure optimal system performance as per BCI standard quality control methods. The half-peak CV (HP-CV) of <2.0 for 488nm laser and <3.0 for the 638nm laser ensures that fluidics stability and laser alignment are optimal. BECKMAN COULTER WHITE PAPER 3
4 Establishing a Size Reference Ladder Flow-Check Pro (10 μm, 6.0 μm and 3.0 μm beads) spiked with 1.0 μm and 0.5 μm latex beads (BCI Cat. No.s: A69183, and respectively) were used to characterize the dynamic range of particle detection under a single set of scatter and PMT voltages. Water only controls were used to identify background signals and identify instrument electronics noise. All data was acquired using FSC parameter discrimination. For N and W FSC detection, 1.0 μm latex beads and Flow-Check Pro fluorospheres were used to illustrate small particle identification. For W 2 FSC detection, 1.0 μm and 0.5 μm beads were used to estimate sub-micron particle detection sensitivity. Using Fluorescence Discrimination to Increase Detection Sensitivity Megamix beads (Biocytex, Cat. # 7801) and 0.21 μm Dragon Green beads (Bangs Laboratories, Inc., Cat.# CP01F/10772) were used according to manufacturer s recommended protocol. Data was acquired using FL1 (FITC) parameter discrimination and set for W 2 FSC detection. Characterization of Biological Microparticles Human platelets were bulk isolated from normal donor peripheral blood samples [6] and treated in vitro with LPS to induce micro-particle formation. Micro-particles from culture supernatant were isolated by differential centrifugation [6]. Micro-particles were also isolated directly from human peripheral blood samples by centrifugation (low rcf) to remove intact cells and subsequently (at higher rcf) to enrich micro-particles for analysis [9]. All micro-particle enriched samples were labeled with AnnexinV-FITC (BCI Cat. No.: IM3546) and anti-human CD41-APC (BCI Cat. No.: B16894) to detect platelet-derived fractions. FMO controls were performed to ensure specificity of reagent binding (data not shown). Gallios cytometer was setup using W 2 FSC setting with FITC discriminator. AnnexinV-FITC + events were analyzed by FSC/SSC to identify <1.0 μm particles. Megamix bead reagent was used to estimate a 1.0 μm particle size cut-off. BECKMAN COULTER WHITE PAPER 4
5 RESULTS Figure 1: Proper maintenance of Gallios flow cytometer permits high sensitivity of fluorescence detection. (A) Multi-intensity beads were used demonstrate high sensitivity of FITC (SI=9.5) and APC (SI=6.4) channel detection. (B) Flow-Check Pro beads were used to measure half-peak CVs (HP-CV) values for FITC and APC detection. Combined, these data demonstrate (i) high sensitivity of fluorescence detection, (ii) proper laser alignment and (iii) stability of system fluidics. Figure 2: FSC detection angle controls dynamic range of small particle detection. The Gallios flow cytometer can detect forward light scatter using Narrow (1-8 ), Wide (1-19 ) and Enhanced Wide (1-19 with log amplification) settings. All data was generated using FSC parameter discrimination. For N and W FSC detection, 1.0 μm latex beads and Flow-Check Pro fluorospheres (10 μm (B), 6 μm (C) and 3 μm (D) beads) were used to illustrate small particle identification. For W 2 FSC detection, 1.0 μm and 0.5 μm beads were used to demonstrate sub-micron particle detection. Water only controls were used to identify background signals. These data demonstrate that a wide dynamic range of particle sizes can be measured using the standard options of the Gallios flow cytometer. BECKMAN COULTER WHITE PAPER 5
6 Figure 3: Enhanced sub-micron particle detection using fluorescence discriminator. (A) Megamix beads were spiked with 0.21 μm fluorescent beads and acquired on the Gallios flow cytometer (W 2 FSC, FITC discriminator). (B) FSC and SSC parameters were shown for all events to illustrate increased sensitivity to 200 nm detection. Figure 4: Identification and characterization of biological micro-particles. (A) Supernatant enriched for lab-created, human platelet micro-particles (B) Platelet-Free Plasma was screened for biological micro-particles (W 2 FSC, FITC discriminator). AnnexinV- FITC + events (left) were analyzed by FSC/SSC (middle) to identify <1.0 μm particles (MP Gate). Megamix bead reagent was used to establish the MP Gate and estimate a 1.0 μm particle size cut-off. The platelet origin of these sub-micron particles was confirmed by expression of CD41 (right). BECKMAN COULTER WHITE PAPER 6
7 Discussion Here we present data that demonstrates the capability of the Gallios W 2 FSC mode to detect sub-micron particles. Our set-up included acquiring 6-Peak Spherotech Rainbow Calibration Particles to confirm the sensitivity and performance of the Gallios instrument (Figure 1). We set instrument PMT voltages so that the first peak of the beads was fully visible on scale and obtained accurate SI measurements for each fluorescent channel used. These values can be followed over time and used as an additional standardization tool to track instrument sensitivity/resolution. Flow-Check Pro beads were used to ensure optimal system performance as per BCI standard quality control methods. The half-peak CV (HP-CV) of <2.0 for 488 nm laser PMTs and <3.0 for the 638 nm laser PMTs ensures that fluidics stability and laser alignments are optimal. These HP-CV values represent the upper limit of permissible variation for system quality purposes; however, investigators should take all appropriate steps to reduce HP-CV values to their lowest reasonable levels for applications that require the greatest sensitivity and stability (e.g. micro-particle detection). Flow-Check Pro beads were used with 1.0 μm Latex particles to create a Size Reference Ladder. The acquisition of Flow-Check Pro beads spiked with 1.0 μm Latex particles (acquired using N or W FSC modes) illustrates that the Gallios is highly sensitive to a dynamic range of small particle detection (Figure 2). To focus on sub-micron particle detection, 0.5 μm and 1.0 μm Latex particles were detected with the W 2 FSC mode and were clearly visible above the instrument noise (Figure 2). These data demonstrate that the Gallios instrument can be easily configured to detect 0.5 μm to 10 μm particles solely based on light scatter discrimination. In order to determine the ability of the Gallios to resolve particles less than 0.5 μm, a fluorescent discriminator was used to acquire Megamix beads spiked with 0.21 μm Dragon Green beads. The discriminator threshold was set to exclude instrument noise (dih20, data not shown) and these small, fluorescent particles were acquired. These data suggest that the Gallios instrument is highly capable of resolving 0.21 μm beads from background noise (Figure 3). In order to confirm that these standardization processes were appropriate for the set-up of biological samples, we characterized human platelet micro-particles and platelet-free plasma. Prior to acquisition of the platelet micro-particles, Megamix beads and FMO controls were utilized to establish a gating strategy. The platelet micro-particles and platelet-free plasma samples were stained with CD41 and Annexin V (Figure 4). All biological samples were acquired using a FITC (FL-1) discriminator. The direct correlation of AnnexinV and CD41 (Figure 4A) seems logical based on the biological constraints of micro-particle formation. Furthermore, the staining pattern observed in plasma samples indicates that the micro-particles present in patient sera are derived from multiple cellular origins (e.g. Annexin V + CD41 - ) (Figure 4B). These data suggest that the Gallios can be standardized to routinely identify sub-micron particles from background noise. Furthermore, acquiring data on the Gallios using the W 2 angle FSC mode best resolves sub-micron particles without losing the definition of larger particles. BECKMAN COULTER WHITE PAPER 7
8 REFERENCES [1] Verhoven B, Schlegel R, Williamson P. Mechanisms of phosphatidylserine exposure, a phagocyte recognition signal, on apoptotic T lymphocytes. J Exp Med 1995 Nov;182 (5): [2] Cocucci E, Racchetti G, Meldolesi J. Shedding microvesicles: artefacts no more. Trends in Cell Biology (2009).19 (2): [3] Piccin A, Murphy W, Smith O. Circulating microparticles: pathophysiology and clinical implications. Blood Reviews 2007; 21: [4] Morel O, Morel N, Jesel L, Freyssinet JM, Toti F. Microparticles: a critical component in the nexus between inflammation, immunity, and thrombosis. Semin. ImmunoPath 2011; 33(5): [5] Kasthuri R, Glover S, Boles J, Mackman N. Tissue Factor and Tissue Factor Pathway Inhibitor as key regulators of global hemostasis: Measurement of their levels in coagulation assays. Semin Thromb Hemost 2010; Oct; 36(7): [6] Shet A, Aras O, Gupta K, Hass M, Rausch D, Saba N, Koopmeiners L, Key N, Hebbel R. Sickle blood contains tissue factor-positive microparticles derived from endothelial cells and monocytes. Blood 2003; Oct 102 (7): [7] Garcia S, Chirinos J, Jimenez J, Del Carpio Munoz F, Canoniero M, Jy W, Jimenez J, Horstman L, Ahn Y. Phenotypic assessment of endothelial microparticles in patients with heart failure and after heart transplantation: switch from cell activation to apoptosis. J Heart Lung Transplant. 2005;24: [PubMed: ]. [8] Toth B, Nieuwland R, Liebhardt S, Ditsch N, Steinig K, Stieber P, Rank A, Gohring P, Thaler CJ, Friese K. Circulating microparticles in breast cancer patients: a comparative analysis with established biomarkers. Anticancer Res. 2008; 28: [PubMed: ]. [9] Orozoco A and Lewis D. Flow cytometric analysis of circulating micro-particles in plasma. Cytometry A June; 77(6): [10] LaCroix R, Robert S, Poncelet P, Kasthuri R, Key N, Dignet-George F. Standardization of platelet-derived microparticle enumeration by flow cytometry with calibrated beads: results of the International Society on Thrombosis and Haemostasis SSC Collaborative workshop. J Thromb Haemo 2010; 8: [11] Bigos M, Stovel R, Parks D. Evaluating multi-color fluorescence data quality among different instruments and different laser powers-methods and results (abstract). Cytometry 2004; 59A: 42. [12] Maecker HT, Frey T, Nomura LE, Trotter J. Selecting fluorochrome conjugates for maximum sensitivity. Cytometry A Dec; 62(2): [13] Brown GT and McIntyre TM. Lipopolysaccharide signaling without a nucleus; Kinase cascades stimulate platelet shedding of proinflammatory IL-1β-rich microparticles. J Immunol 2011; 186: BECKMAN COULTER WHITE PAPER 8
9 REAGENT DETAILS Reagent Supplier Order Details 6-peak SPHERO Rainbow Calibration Particles Spherotech, Inc. RCP-60-5 Flow-Check Pro beads Beckman Coulter A μm latex beads Beckman Coulter μm latex beads Beckman Coulter Megamix beads Biocytex μm Dragon Green beads Bangs Labs, Inc. CP01F/10772 AnnexinV-FITC Beckman Coulter IM3546 CD41-APC Beckman Coulter B16894 NOTES The results demonstrated in this application sheet represent those generated on the Beckman Coulter Gallios Flow Cytometer. As differences exist in the performance between analyzers, the author cannot guarantee a similar appearance with the use of other flow cytometers. Beckman Coulter, Inc. Gallios Flow Cytometer (3 laser, 10-color system using standard filter configuration) was used to perform these studies. Special Thanks to Nancy Fisher PhD (University of North Carolina) and Micah Mooberry MD (University of North Carolina) and Bob Zucker PhD (USEPA) for their input, time and samples. BECKMAN COULTER WHITE PAPER 9 BR-18063A B
Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement
Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement Andreas Spittler, MD, Associate Professor for Pathophysiology, Medical University
Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer
Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer Presented by Clare Rogers, MS Senior Marketing Applications Specialist BD Biosciences 23-13660-00 Webinar Overview Multicolor
123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.
Page 1 of 1 Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Normal human peripheral blood was stained with Anti- Human CD45 PE (cat.
Introduction to flow cytometry
Introduction to flow cytometry Flow cytometry is a popular laser-based technology. Discover more with our introduction to flow cytometry. Flow cytometry is now a widely used method for analyzing the expression
APPLICATION INFORMATION
DRAFT: Rev. D A-2045A APPLICATION INFORMATION Flow Cytometry 3-COLOR COMPENSATION Raquel Cabana,* Mark Cheetham, Jay Enten, Yong Song, Michael Thomas,* and Brendan S. Yee Beckman Coulter, Inc., Miami FL
Spherotech, Inc. 27845 Irma Lee Circle, Unit 101, Lake Forest, Illinois 60045 1
78 Irma Lee Circle, Unit 0, Lake Forest, Illinois 00 SPHERO TM Technical Note STN- Rev B 008 DETERMINING PMT LINEARITY IN FLOW CYTOMETERS USING THE SPHERO TM PMT QUALITY CONTROL EXCEL TEMPLATE Introduction
Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer
Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer Contents 2 Thresholds 2 Setting the Threshold When analyzing small particles, defined as particles smaller than 3.0 µm, on the
Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and
Using BD FACSDiva CST To Evaluate Cytometer Performance, Create Custom Assay Settings and Implement Cross-Instrument and Cross-Site Standardization of Assays PART 2 Alan M. Stall Director, Advanced Cytometry
Standardization, Calibration and Quality Control
Standardization, Calibration and Quality Control Ian Storie Flow cytometry has become an essential tool in the research and clinical diagnostic laboratory. The range of available flow-based diagnostic
Beckman Coulter Scientific Symposium
Application Information Bulletin: Sorting Coulter Scientific Symposium MoFlo Astrios* Enhanced Forward Scatter+: 0.2 μm to 30 μm Dynamic FSC Detection Dr. Carley D. Ross, Mike Morrell, Robin Morris, Blake
No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer
APPLICATION NOTE Attune NxT Flow Cytometer No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer Introduction Standard methods for isolating and detecting leukocytes
COMPENSATION MIT Flow Cytometry Core Facility
COMPENSATION MIT Flow Cytometry Core Facility Why do we need compensation? 1) Because the long emission spectrum tail of dyes causes overlap like with the fluorophores FITC and PE. 2) For sensitivity reasons,
Introduction to Flow Cytometry
Outline Introduction to Flow Cytometry Basic Concept of Flow Cytometry Introduction to Instrument Subsystems Daisy Kuo Assistant Product Manager E-mail: [email protected] BDBiosciences Application Examples
BD FACSComp Software Tutorial
BD FACSComp Software Tutorial This tutorial guides you through a BD FACSComp software lyse/no-wash assay setup run. If you are already familiar with previous versions of BD FACSComp software on Mac OS
Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility
10.1071/RD14043_AC CSIRO 2015 Supplementary Material: Reproduction, Fertility and Development, 2015, 27(8), 1187 1196. Supplementary Material Free-radical production after post-thaw incubation of ram spermatozoa
Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking
Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking Mark KuKuruga Senior Technical Applications Specialist BD Biosciences 23-14462-00 Outline
Immunophenotyping peripheral blood cells
IMMUNOPHENOTYPING Attune Accoustic Focusing Cytometer Immunophenotyping peripheral blood cells A no-lyse, no-wash, no cell loss method for immunophenotyping nucleated peripheral blood cells using the Attune
CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE
CELL CYCLE BASICS Analysis of a population of cells replication state can be achieved by fluorescence labeling of the nuclei of cells in suspension and then analyzing the fluorescence properties of each
CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE
CELL CYCLE BASICS Analysis of a population of cells replication state can be achieved by fluorescence labeling of the nuclei of cells in suspension and then analyzing the fluorescence properties of each
Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose
Selecting Reagents for Multicolor Flow Cytometry Holden Maecker and Joe Trotter BD Biosciences, San Jose Contents 1 The basics: Know your instrument 2 Fluorochromes: Go for the bright 3 Colors and specificities:
Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis
Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis Bilge Karaçalı, PhD Department of Electrical and Electronics Engineering Izmir Institute of Technology Outline Compensation and gating
Introduction to Flow Cytometry
Introduction to Flow Cytometry presented by: Flow Cytometry y Core Facility Biomedical Instrumentation Center Uniformed Services University Topics Covered in this Lecture What is flow cytometry? Flow cytometer
Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))
Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH)) October 14, 2013 1 Licensing Under the Artistic License, you are
Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement
What is Flow Cytometry? Flow Cytometry Basic Principle and Applications BD Biosciences Daisy Kuo ([email protected]) Flow = Fluid Cyto = Cell Metry = Measurement A variety of measurements are made on cells,
Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service
Introduction into Flow Cytometry Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service How does a FACS look like? FACSCalibur FACScan What is Flow Cytometry?
Beckman Coulter CytoFLEX Violet SSC: an Alternative to FSC PMT or Fluorescence in the Detection of Extracellular Vesicles
Beckman Coulter CytoFLEX Violet SSC: an Alternative to FSC PMT or Fluorescence in the Detection of Extracellular Vesicles TECHNICAL INFORMATION BULLETIN Principle of the Technique Vasilis Toxavidis, Virginia
Boundary-breaking acoustic focusing cytometry
Boundary-breaking acoustic focusing cytometry Introducing the Attune NxT Acoustic Focusing Cytometer a high-performance system that s flexible enough for any lab One of the main projects in my laboratory
CyAn : 11 Parameter Desktop Flow Cytometer
CyAn : 11 Parameter Desktop Flow Cytometer Cyan ADP 3 excitation lines 488nm, 635nm, and UV or violet 11 simultaneous parameters FSC, SSC, and 7-9 colors with simultaneous width, peak, area, and log on
a Beckman Coulter Life Sciences: White Paper
a Beckman Coulter Life Sciences: White Paper Violet-Excited nim-da Allows Efficient and Reproducible Cell Cycle Analysis on the Gallios Flow Cytometer Authors: Valdez, Ben 1. Carr, Karen 2. Norman, John
Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility
Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility The mention of commercial products, their sources, or their use in connection
use. 3,5 Apoptosis Viability Titration Assays
Introduction Monitoring cell viability can provide critical insights into the effectiveness of biological protocols and the stability of biological systems including: the efficacy of cell harvesting procedures,
Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T
Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom Cat. Reference: STP-25T Reagent provided:: 25 Stepcount tubes for 25 test INTENDED USE. Immunostep
Instrument Characterization and Performance Tracking for Digital Flow Cytometers
Instrument Characterization and Performance Tracking for Digital Flow Cytometers BD Biosciences Cytometer Set-up & Tracking (CS&T) System For Research Use Only. Not for use in diagnostic or therapeutic
Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.
Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy. At the end of this session, the participant will be able to: 1. Describe the components of a flow cytometer 2. Describe the gating
Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size
Introduction to Flow Cytometry -- BD LSR II Daisy Kuo 郭 正 佼 Assistant Product Manager BD Biosciences [email protected] What is Flow Cytometry? Flow = Fluid Cyto = Cell Metry = Measurement A variety of measurements
powerful. Intuitive. Customizable. The new star of benchtop flow cytometry
powerful. Intuitive. Customizable. The new star of benchtop flow cytometry About ACEA Established in 2002, ACEA Biosciences, Inc. develops cutting-edge cell analysis platforms for life science research.
Islet Viability Assessment by Single Cell Flow Cytometry
Islet Viability Assessment by Single Cell Flow Cytometry Page 1 of 8 Purpose: To comprehensively assess the viability of the islet cell preparation prior to transplantation. Tissue Samples: A sample containing
Flow Data Analysis. Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA FLOWJO CYTOMETRY DATA ANALYSIS SOFTWARE
Flow Data Analysis Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA Flow Data Analysis From Cells to Data - data measurement and standard Data display and gating - Data Display options -
Fluorescence Compensation. Jennifer Wilshire, PhD [email protected]
Fluorescence Compensation Jennifer Wilshire, PhD [email protected] Outline 1. Compensation Basics 2. Practical Applications -selecting comp controls (cells, stains?) 3. Multicolor Issues -spreading due
Uses of Flow Cytometry
Uses of Flow Cytometry 1. Multicolour analysis... 2 2. Cell Cycle and Proliferation... 3 a. Analysis of Cellular DNA Content... 4 b. Cell Proliferation Assays... 5 3. Immunology... 6 4. Apoptosis... 7
WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS
FOR IN-VITRO DIAGNOSTIC USE INVITROGEN CAL-LYSE TM Lysing Solution WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS CAL-LYSE TM CATALOG No. GAS-010 250 tests 25 ml CATALOG No. GAS-010S-100
INSIDE THE BLACK BOX
FLOW CYTOMETRY ESSENTIALS INSIDE THE BLACK BOX Alice L. Givan Englert Cell Analysis Laboratory of the Norris Cotton Cancer Center Dartmouth Medical School HOW NOT TO BE A FLOW CYTOMETRIST Drawing by Ben
Annexin V-EGFP Apoptosis Detection Kit
ab14153 Annexin V-EGFP Apoptosis Detection Kit Instructions for Use For the rapid, sensitive and accurate measurement of apoptosis in various samples This product is for research use only and is not intended
Three Rules for Compensation Controls
From FlowJo s Daily Dongle Three Rules for Compensation Controls First and foremost, there must be a single-stained control for every parameter in the experiment! In addition, there are three rules for
CFSE Cell Division Assay Kit
CFSE Cell Division Assay Kit Item No. 10009853 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 4 Precautions
ArC Amine Reactive Compensation Bead Kit
ArC Amine Reactive Compensation Bead Kit Catalog no. A1346 Table 1. Contents and storage information. Material Amount Composition Storage Stability ArC reactive beads (Component A) ArC negative beads (Component
Instructions for Use. CyAn ADP. High-speed Analyzer. Summit 4.3. 0000050G June 2008. Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835
Instructions for Use CyAn ADP High-speed Analyzer Summit 4.3 0000050G June 2008 Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835 Overview Summit software is a Windows based application that
Standard Operating Procedure
1.0 Purpose: 1.1 The characterisation of of main leukocyte subsets in peripheral blood cells from mice by flow cytometry. Reliable values of frequencies of leukocyte clusters are very much dependent on
Intracellular Calcium and Phosphatidylserine Exposure in the red Blood Cells
Intracellular Calcium and Phosphatidylserine Exposure in the red Blood Cells Biotechnology Seminar 2 Yaser Alkhaled 30.10.13 Table of Content 1. Introduction.... 3 2. Membrane of red blood cell.... 4 3.
These particles have something in common
These particles have something in common Blood cells Chromosomes Algae Protozoa Certain parameters of these particles can be measured with a flow cytometer Which parameters can be measured? the relative
Annexin V-FITC Apoptosis Detection Kit
ab14085 Annexin V-FITC Apoptosis Detection Kit Instructions for Use For the rapid, sensitive and accurate measurement of Apoptosis in living cells (adherent and suspension). This product is for research
Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers
An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers BD Biosciences, San Jose, CA Contents 2 Introduction to compensation 5 Tips for setting up compensation 10 Tools for easy,
PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.
PROTOCOL Immunostaining for Flow Cytometry 1850 Millrace Drive, Suite 3A Eugene, Oregon 97403 Rev.0 Background The combination of single cell analysis using flow cytometry and the specificity of antibody-based
Setting up and calibration of a flow cytometer for multicolor immunophenotyping
Journal of Biological Regulators and Homeostatic Agents Setting up and calibration of a flow cytometer for multicolor immunophenotyping J. KRAAN 1, J.W. GRATAMA 1, M. KEENEY 2, J.L. D HAUTCOURT 3 1 Department
Whole Blood Flow Cytometry
Whole Blood Flow Cytometry y Nailin Li Department t of Medicine, i Clinical i l Pharmacology Unit Karolinska Institute/University Hospital, 171 76 Stockholm Department of Pathology & Pathophysiology Zhejiang
Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract
arch 212 Standardizing Application Setup Across ultiple Flow Cytometers Using BD FACSDiva Version 6 Ellen einelt, ervi Reunanen, ark Edinger, aria Jaimes, Alan Stall, Dennis Sasaki, Joe Trotter Contents
Annexin V-FITC Apoptosis Detection Kit
ab14085 Annexin V-FITC Apoptosis Detection Kit Instructions for Use For the rapid, sensitive and accurate measurement of Apoptosis in living cells (adherent and suspension). This product is for research
Perioperative management of Dual Antiplatelet therapy post drug eluting stent-changing time
Perioperative management of Dual Antiplatelet therapy post drug eluting stent-changing time Robert Chilton DO, FACOI, FACC, FAHA Professor of Medicine University of Texas Health Science Center Director
International Beryllium Conference, Montreal, Canada March 10, 2005
Alternative Lymphocyte Proliferation Tests: BrdU and Flow Cytometry Based Tests International Beryllium Conference, Montreal, Canada March 10, 2005 Tim K. Takaro Department of Environmental and Occupational
LIVE/DEAD Fixable Dead Cell Stain Kits
USER GUIDE LIVE/DEAD Fixable Dead Cell Stain Kits Pub. No. MAN0002416 (MP34955) Rev. A.0 Table 1. Contents and storage Material Amount Storage Stability Individual Kits: Blue, violet, aqua, yellow-, green,
Principles of Flowcytometry
Objectives Introduction to Cell Markers: Principles of Flowcytometry Michelle Petrasich NZIMLS Scientific Meeting August 24, 2010, Paihia What are cell markers How do we detect them Production of Monoclonal
FlowSight. Flow cytometry with vision
FlowSight Flow cytometry with vision Flow cytometry with vision Introducing FlowSight Capable: Sensitive and flexible for every need Intuitive: Easy-to-use, with imagery for every cell Affordable: Designed
Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...
Immunophenotyping Flow Cytometry Tutorial Contents Experimental Requirements...1 Data Storage...2 Voltage Adjustments...3 Compensation...5 Experimental Requirements For immunophenotyping with FITC and
FACSCanto RUO Special Order QUICK REFERENCE GUIDE
FACSCanto RUO Special Order QUICK REFERENCE GUIDE INSTRUMENT: 1. The computer is left on at all times. Note: If not Username: Administrator Password: BDIS 2. Unlock the screen with your PPMS account (UTSW
MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:
INTRODUCTION Flow Cytometry involves the use of a beam of laser light projected through a liquid stream that contains cells, or other particles, which when struck by the focused light give out signals
Science is hard. Flow cytometry should be easy.
Science is hard. Flow cytometry should be easy. TABLE OF CONTENTS 1 INTRODUCTION TO BD ACCURI C6 SOFTWARE... 1 1.1 Starting BD Accuri C6 Software... 1 1.2 BD Accuri C6 Software Workspace... 2 1.3 Opening
FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed
FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS By: Douaa Moh. Sayed Definition Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid. It allows
FITC Annexin V/Dead Cell Apoptosis Kit with FITC annexin V and PI, for Flow Cytometry
FITC Annexin V/Dead Cell Apoptosis Kit with FITC annexin V and PI, for Flow Cytometry Catalog no. V13242 Table 1. Contents and storage information. Material Amount Composition Storage* Stability FITC annexin
How to operate the BD FACSCanto flow cytometer
How to operate the BD FACSCanto flow cytometer Preface Dear colleague, the BD FACSCanto flow cytometer is use to operate, however, it is a delicate instrument for measuring fluorescence of single cells.
BD FACSDiva 4.1 - TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY
BD FACSDiva 4.1 - TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY IMPORTANT NOTES BEFORE READING THIS TUTORIAL This is a very expensive piece of equipment so PLEASE treat it with respect! After you are done
Cell Cycle Phase Determination Kit
Cell Cycle Phase Determination Kit Item No. 10009349 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 3 Safety
Flow cytometry basics fluidics, optics, electronics...
Title Flow cytometry basics fluidics, optics, electronics... RNDr. Jan Svoboda, Ph.D. Cytometry and Microscopy Core Facility IMB, CAS, v.v.i Vídeňská 1083 Fluorescence Fluorescence occurs when a valence
Lab 2. Isolation of mononuclear cells from peripheral blood and separation into subpopulations
Lab 2 Isolation of mononuclear cells from peripheral blood and separation into subpopulations Supervisors: Sissela Broos [email protected] tel: 222 96 78 Niclas Olsson [email protected]
UNIVERSITY OF PÉCS MEDICAL SCHOOL FLOW CYTOMETRY AND CELL SEPARATION BIOPHYSICS 2. 2015 4th March Dr. Beáta Bugyi Department of Biophysics Flow cytometry and cell separation FLOW = STREAM OF FLUID in a
CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles
CyFlow SL Microbiology Detection and Analysis of Microorganisms and Small Particles 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements for reliable results
The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee
January, 1999 From: To: Subject: The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee NIAID DAIDS Flow Cytometry Laboratories Comparison study information for labs wishing to switch
Refractive index of extracellular vesicles by nanoparticle tracking analysis
Refractive index of extracellular vesicles by nanoparticle tracking analysis Edwin van der Pol 1,2 Frank Coumans 1,2, Anita Böing 1, Auguste Sturk 1, Ton van Leeuwen 2, Rienk Nieuwland 1 April 30th, 2014
Hoechst 33342 HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, 1797-806)
Hoechst 33342 HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, 1797-86) The Hoechst purification was established for murine hematopoietic stem cells (HSC)
flow cytometry reinvented
FLOW CYTOMETRY flow cytometry reinvented The Attune Acoustic Focusing Cytometer Precision and at all speeds for rare events and precious samples The Attune Acoustic Focusing Cytometer Precise high collection
FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences
FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data Monisha Sundarrajan, PhD BD Biosciences 23 13795 00 Agenda Introduction Overview of BD CBA bead based immunoassays FCAP
Bacterial Detection and Live/Dead Discrimination by Flow Cytometry
A P P L I C A T I O N N O T E Bacterial Detection and Live/Dead Discrimination by Flow Cytometry M I C R O B I A L C Y T O M E T R Y BD FACSCalibur, BD FACSort Flow Cytometers Introduction Accurate determination
Potency Assays for an Autologous Active Immunotherapy (Sipuleucel-T) Pocheng Liu, Ph.D. Senior Scientist of Product Development Dendreon Corporation
Potency Assays for an Autologous Active Immunotherapy (Sipuleucel-T) Pocheng Liu, Ph.D. Senior Scientist of Product Development Dendreon Corporation Sipuleucel-T Manufacturing Process Day 1 Leukapheresis
HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE
POWERFUL. INTUITIVE. CUSTOMIZABLE. HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE ABOUT ACEA Established in 2002, ACEA Biosciences, Inc. develops cutting-edge cell analysis platforms for life science research.
CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping
CyFlow SL Healthcare Immunology Portable FCM System for 3-colour Immunophenotyping 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements for reliable results
Absolute counting using flow cytometry. Bright Count Microspheres
Absolute counting using flow cytometry Single-platform system for absolute counts I PRODUCT MANUAL [REF] IQP-391 [REF] IQP-392 s 50 tests s 100 tests [IVD] In Vitro Diagnostic medical device IQ Products
Chapter 8. Summary and Perspectives
Chapter 8 Summary and Perspectives 131 Chapter 8 Summary Overexpression of the multidrug resistance protein MRP1 confer multidrug resistance (MDR) to cancer cells. The contents of this thesis describe
Compensation Controls Data Visualization Panel Development Gating Quantum Dots
Compensation Controls Data Visualization Panel Development Gating Quantum Dots FITC Single Stain Control FITC PE Argon Laser FL1 FL2 450 500 550 600 FITC Compensation Control Unwanted signal detected in
Cell Discovery 360: Explore more possibilities.
Cell Discovery 360: Explore more possibilities. Flexible solutions for the BioPharma laboratory Blood Banking Capillary Electrophoresis Centrifugation Flow Cytometry Genomics Lab Automation Lab Tools Particle
CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection
CyTOF2 Mass cytometry system Unveil new cell types and function with high-parameter protein detection DISCOVER MORE. IMAGINE MORE. MASS CYTOMETRY. THE FUTURE OF CYTOMETRY TODAY. Mass cytometry resolves
Easy to use. Compact. Flexible. Sorting Chip
SH800Z Cell Sorter The SH800Z is a compact, affordable, and easy to use cell sorter developed using the state- of-the art technologies from Sony. An array of automated mechanisms makes it an ideal sorter
Compensation in Flow Cytometry
Compensation in UNIT.4 The term compensation, as it applies to flow cytometric analysis, refers to the process of correcting for fluorescence spillover, i.e., removing the signal of any given fluorochrome
Practical Cell Analysis
Practical Cell Analysis Dimitri Pappas Dept of Chemistry & Biochemistry, Texas Tech University, USA WILEY A John Wiley and Sons, Ltd, Publication Contents Preface Acknowledgments xiii xix 1 Getting Started
Flow Cytometry A Basic Overview
Flow Cytometry A Basic Overview Overview Flow cytometry is a powerful technology for investigating many aspects of cell biology and for isolating cells of interest. Flow cytometry utilizes highly focused,
Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction
Application Note 10 Measurement of Cell Recovery After Sorting with a Catcher-Tube-Based Cell Sorter Introduction In many experiments using sorted cells, it is important to be able to count the number
DELPHI 27 V 2016 CYTOMETRY STRATEGIES IN THE DIAGNOSIS OF HEMATOLOGICAL DISEASES
DELPHI 27 V 2016 CYTOMETRY STRATEGIES IN THE DIAGNOSIS OF HEMATOLOGICAL DISEASES CLAUDIO ORTOLANI UNIVERSITY OF URBINO - ITALY SUN TZU (544 b.c. 496 b.c) SUN TZU (544 b.c. 496 b.c.) THE ART OF CYTOMETRY
Cytell Cell Imaging System
Cytell Cell Imaging System Simplify your cell analysis and start changing tomorrow today www.gelifesciences.com/cytell The Cytell Cell Imaging System is an intuitive cell analysis instrument that streamlines
GETTING STARTED. 6. Click the New Specimen icon.
BD FACSDiva Software Basic Experiment Guide Please note, this guide is not intended to take the place of in-person training but is to be used as a reference as needed after completing training with Unified
Unit 2: Cells, Membranes and Signaling CELL MEMBRANE. Chapter 5 Hillis Textbook
Unit 2: Cells, Membranes and Signaling CELL MEMBRANE Chapter 5 Hillis Textbook HOW DOES THE LAB RELATE TO THE NEXT CHAPTER? SURFACE AREA: the entire outer covering of a cell that enables materials pass.