SED2 VFD NEMA Type 3R Bypass

Similar documents
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Electronic Control Devices The European Product Catalogue 2007

Variable speed drives

Electronic Control Devices The European Product Catalogue 2007

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

SECTION VARIABLE FREQUENCY DRIVES

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

32VFD Variable Frequency Drives for Centrifugal Chillers

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

Model: DC-A2IO Advanced HVAC Controller

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Number 1 in efficiency

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

HVAC DRIVE H300 HVAC Drive for Building Automation

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PowerFlex 700 and 700H Packaged Drives. Technical Data

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Products and solutions for lifting systems

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Power Supplies 3. SDN-P DIN Rail Series

Multi-Range Programmable DC Power Supplies 9115 Series

PSR The compact range Description


FX07 Field Controller

DCS Series 1 kw, 1.2 kw, & 3 kw

Frequency Converter Fv

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

ACS-30-EU-EMDR-10-MOD

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

EFC Frequency converters

Multi-Range Programmable DC Power Supplies 9115 Series

Thyristor-controlled power supplies and battery chargers

Diesel Engine Driven Generators Page 1 of 6

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

RRV934. Multi-controller. Synco living

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

GTEC transfer switch open transition

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

VLT 6000 HVAC. Contents

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

GPD 506/P5 Start-up Procedure and Checklist

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Application/Connection Examples

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

SmartVFD HVAC and BYPASS

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Products and solutions for pumping, irrigation and piping

T7079A,B Solid State Remote Temperature Controllers

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

vacon x series rugged drives for the real world

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

FX07 Field Controller

Photovoltaic Solar Energy Unit EESFB

SMS GSM Alarm Messenger

SECTION DETECTION AND ALARM

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

CompactLogix Power Supplies Specifications

Specifying a Variable Frequency Drive s

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

MLC TM Maximum Productivity and Versatility for Control without Compromise!

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Electronic overload relay EF19 and EF45

CE6500 Energy Recovery Ventilator

IntesisBox Modbus Server SAMSUNG Air Conditioners

INSTALLATION INSTRUCTIONS

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Safety automation solutions

THERMAL MANAGEMENT SOLUTIONS

A1000 Cheat Sheet (Open Loop Vector)

NX safety stand-alone

Research RF Sputtering Packages

Installation manual. Generator Paralleling Controller GPC multi-line C

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Z1000 HVAC Drive. 3 HP to 500 HP Fan and Pump Applications. Specifications

How To Use The Vacon 0 Machinery

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Flow Monitoring System

Installation, Operation and Maintenance Manual

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Variable Speed Drives

Easy to connect - Easy to configure Easy to install

Transcription:

SED2 VD NEMA Type 3R Bypass Description The NEMA Type 3R Bypasses are companion packages for the family of SED2 Variable requency Drives. NEMA Type 3R enclosed bypasses are manufactured for outdoor locations that are not in direct sunlight. The 3R rating provides a degree of protection to the enclosed SED2 VD and electrical control components. A heater is supplied to protect against condensation. The standard package is rated to 104 (40 C). A high temperature package, rated to 122 (50 C), is available. The SED2 is designed specifically for HVAC applications and supports a variety of digital and analog I/O and provides built-in PID features to control pumps and fans. or information on the family of SED2 VDs, see the SED2 Variable requency Drives Submittal Sheet (154-042). Product Numbers Your Product Number V B A 3 X Example Product Number V B A 4 4 0. D 3 2 0 X H T 1 Model(s) VB Vfd with Bypass Series A Conventional Bypass (Standard) Voltage 1 208 V * 2 230 to 240 V * 3 380 to 480 V * 4 500 to 600 V HP rating 0.5, 0.7, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 7.5, 10.,15.,20.,25.,30.,40.,50.,60.,75.,100,125 Disconnect D Disconnect used Disconnect NEMA rating 3 NEMA Type 3R Contactor 0 None 2 2 Contactors 3 3 Contactors Reactor 0 None 3 Line Reactor L Load Reactor ilter X No ilter Options HT1 High Temperature rating (NEMA 3R only) ** * 208 Vac and 230/240 Vac to 3 hp are all HT1; 480 Vac to 5 hp are all HT1. ** HT1 (122, 50 C) not available for all ratings. eatures Bypass Power 2-Contactor: Output and Bypass Overload protection in bypass mode. Step-down transformer with fused primary and secondary. Contactors electrically and mechanically interlocked. 3-Contactor (optional): Input, Output, and Bypass In addition to the 2-contactor features, 3-contactor features provide: Drive test function. Complete electrical isolation of drive. Input Device Disconnect switch. used disconnect (optional). All doors are interlocked and padlockable. Reactor Options Line reactor mounted in bypass enclosure. Line reactor supplied separately (in NEMA Type 3R enclosure). Load reactor (in NEMA Type 3R enclosure) supplied separately. Siemens Building Technologies, Inc. Page 1 of 8

SED2 VD NEMA Type 3R Bypass Bypass Control Auto Bypass Relay logic allows user to send the motor to bypass mode based on the drive s programmable relay. Enable Input Generally used for safety tie-ins; the motor will not operate the drive or bypass when open. Common Remote Start/Stop Can be used in both drive and bypass mode. Essential Services Mode Typically used for smoke purge; the motor goes to bypass regardless of the selected mode. No call to stop will have an effect, including open safety or stop commands. Only turning the power off or opening this contact will stop the motor. Bypass Door Mounted Control Devices 2-Contactor Units Drive-Off-Bypass selector Bypass pilot light 3-Contactor Units Drive-Off-Bypass selector Bypass pilot light Drive Test On-Off selector Accessories SED2 NEMA Type 3R VD & Bypass EMC ilter Assembly for Enclosure Size, PN 994-830 SED2 NEMA Type 3R VD & Bypass EMC ilter Assembly for Enclosure Size, PN 994-831 NEMA Type 3R Reactor Enclosure, Small, PN 994-816 NEMA Type 3R Reactor Enclosure, Medium, PN 994-817 NEMA Type 3R Reactor Enclosure, Large, PN 994-818 loor Mounting Kit, PN 994-809 Dimensions 30 (762) 28-1/2 (724) ENCLOSURE 34 (864) 18 (457) PTH = 11-1/2 (292) 57 (1448) 56-1/8 (1425) ENCLOSURE 46 (1169) 30 (762) 75 (1905) 74-1/8 (1882) ENCLOSURE 58 (1473) 42 (1067) Enclosure Size Wt. Lb (kg) 130 (59) 300 (136) 550 (249) NOTE: Actual weight will be affected by actual horsepower/ voltage and selected power options. MOUNTING CLEARANCE PTH = 12-1/2 (318) OR PROPER AIRLOW: LEAVE 1 OOT (305 mm) BETWEEN THE NEMA TYPE 3R AND ANY ADJACENT SOLID STRUCTURE THAT IS NOT USED OR MOUNTING PURPOSES. PTH = 16-1/2 (419) LEAVE 3 EET (914 mm) BETWEEN THE NEMA TYPE 3R AND ANY OTHER NEMA TYPE 3R OR VD. Page 2 of 8 Siemens Building Technologies, Inc.

SED2 VD NEMA Type 3R Bypass Submittal Sheet Table 1. NEMA Type 3R Bypass Non-HT1 Enclosure Sizes and Power Ranges. HP.5.7 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kw.37.5.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 19 22 30 37 45 55 75 90 208/ 230V (Rated as HT1, High Temperature package) N/A 480V (Rated as HT1, High Temperature package) 575V Table 2. NEMA Type 3R Bypass HT1 Enclosure Sizes and Power Ranges. HP.5.7 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kw.37.5.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 19 22 30 37 45 55 75 90 208/ 230V N/A 480V N/A 575V N/A Table 3. Bypass Output Current Ratings (Amps) Per NEC Motor Tables. HP.5.75 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 208V 2.3 3.0 3.9 5.5 7.4 10.4 16.7 22 28 42 54 68 80 104 130 154 230V 2.2 3.0 3.9 5.5 6.8 9.6 15.2 22 28 42 54 68 80 104 130 154 460V 1.1 1.6 2.1 3.0 3.4 4.8 7.6 11 14 21 27 34 40 52 65 77 96 124 156 575V.9 1.3 1.4 2.1 2.7 3.9 6.1 9 11 17 22 27 32 41 52 62 77 99 125 NOTE: Drives are current rated devices. Verify that the listed ratings are the motor full load current rating. Typical Specifications SED2 Bypasses shall send the motor to bypass mode based on an easily accessible door-mounted selector or based on the drive s programmable relay. A bypass pilot light shall provide indication of the bypass mode. The bypass mode shall provide overload protection. Contactors shall be electrically and mechanically interlocked. An essential services mode shall send the motor to bypass regardless of the selected mode. Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 3

SED2 VD NEMA Type 3R Bypass Wiring Diagrams U2 116 1L1 116 1L2 TRANSORMER PRIMARY CONTACTS: 230/460/575v PRIMARY VOLTAGE. ACTUAL CONNECTIONS VARY WITH VOLTAGE. SUPPLIED ON UNITS THAT DO NOT HAVE. [H1] [H3] [H2] [H4] 5 OL1 SUPPLIED 4 1 4 SAETIES 3 (96) (95) [X] U3 [X1] [X2] SECONDARY VOLTAGE 115 VAC X2 DR#2 AN DR#2 HEAT 5 O INSTALL DRIVE OR REMOTE RR 8 10 11 12 xoo 9 10 5 6 (12) (8) (SHIPPED WITHOUT ) xoo 2 ESSENTIAL ESSENTIAL 13 SERVICE 14 15 SERVICE 16 ENABLED ACTIVE 3 ESR (14) (13) 5 6 1 REMOTE 2 RR START (14) (13) VD1 (CONTROL TERMINALS) 5 21 22 7 DR1 (14) (13) SUPPLIED ON UNITS VD1 (CONTROL TERMINALS) THAT DO NOT HAVE 5. 24 25 7 oox xoo INSTALL OR LOCAL 10 7 8 12 (SHIPPED WITH ) ESR (12) (8) DR2 (14) (13) 13 (A1) M1 A (A2) 18 M3 (A1) (A2) ESSENTIAL SERVICE RELAY RUN RELAY DRIVE RELAY #1 DRIVE RELAY#2 (MUST ALWAYS BE PROGRAMMED TO RUN) CONTACTOR LIGHT INSTALL OR NORMAL VD OUTPUT ESR M1 14 CONTACTOR 15 11 12 16 17 (10) (2) (A1) (A2) (SHIPPED WITH ) VD INPUT CONTACTOR DRIVE TEST ON O xo ONLY SUPPLIED WITH OPTIONAL THREE CONTACTOR (ADDITION O DRIVE INPUT CONTACTOR). X TERMINAL NUMBER X ON CBT-1. igure 1. NEMA Type 3R Bypass 120 Vac Control Circuit. Page 4 of 8 Siemens Building Technologies, Inc.

SED2 VD NEMA Type 3R Bypass Submittal Sheet 20 21 22 23 24 25 12 13 14 15 16 17 26 27 28 29 30 +10VDC +0VDC DRIVE CONTROL TERMINATIONS CONTROL TERMINATIONS LOCATED ON DRIVE I/O MODULE. RL1 NC RL1 NO RL1 COM RL2 NC RL2 NO RL2 COM 1 2 3 4 5 6 7 8 9 10 11 105 AIN2- AO1+ AO1- PTC A PTC B DIN5 DIN6 AO2+ AO2- ISO 0VDC P+ 108 109 N- AIN1+ AIN1- DIN1 DIN2 DIN3 DIN4 ISO 24VDC AIN2+ ANALOG INPUT EXAMPLES EXTERNAL EXTERNAL 0 TO 10V 0/4 TO 20mA 2 3 2 3 4 - + + - SPEED POTENTIOMETER 1 2 3 VD 24 VDC POWERED 0/4 ma VICE (POWER CONSUMPTION CANNOT EXCEED 100mA) 2 3 4 9 28 ma 4.7K OHM POWER RR CONTROL INTER-CONNECTION BETWEEN PANEL. CONTROL TERMINATIONS LOCATED IN ENCLOSURE CBT-1. REMOTE START SUPPLIED SAETIES INSTALL OR REMOTE CONTROL TERMINATIONS INSTALL OR LOCAL TERMINALS 9 THROUGH 12 ARE USED OR AUTO EATURE. I USING THIS EATURE, SEE INSTRUCTION OR WIRING AND OR DRIVE PROGRAMMING. ESSENTIAL SERVICE ENABLED ESSENTIAL SERVICE ACTIVE NOT OR USE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PROVI DRY CONTACT PROVI DRY CONTACT WITH SHIPPED WITH INSTALLED OR NON-AUTO PROVI DRY CONTACT PROVI DRY CONTACT igure 2. NEMA Type 3R Bypass Control Terminals. Siemens Building Technologies, Inc. Page 5 of 8

SED2 VD NEMA Type 3R Bypass POWER SUPPLY 3 PHASE 60 Hz OPTIONAL INPUT LINE REACTOR (SUPPLIED LOOSE) A1 B1 A2 B2 C1 C2 OPTIONAL SUPPLEMENTARY POWER USES - MAIN SHORT CIRCUIT PROTECTION BY OTHERS (SEE NOTE 1) DISC1 L1 (T1) 1L1 (L1) U1 2L1 L2 (T2) 1L2 (L2) 2L2 L3 (T3) 1L3 (L3) 2L3 OPTIONAL DRIVE INPUT CONTACTOR M3 LUG (1) (2) 3L1 3L2 (3) (4) 3L3 (5) (6) OPTIONAL INPUT LINE REACTOR A1 B1 C1 A2 B2 C2 R S T VD1 U V W U V W M1 (5) (6) (3) (4) (1) (2) (1) (2) (3) (4) (5) (6) ONLY SUPPLIED ON UNITS WITH OL1 1T1 (T1) 1T2 (T2) 1T3 (T3) OPTIONAL OUTPUT LOAD REACTOR (SUPPLIED LOOSE) A1 B1 C1 A2 B2 C2 M AC MOTOR ( SUPPLIED) 1L1 1L2 TO STEP-DOWN CONTROL TRANSORMER LUG VD1 CONTROL TERMINALS 1 2 3 4 5 6 7 8 9 10 11 RR (6) (10) NOTES: 1. Branch circuit protection to be provided by installer, per UL508A, if not provided with drive. 2. or bypass operation modify these drive parameters: P0704 (0) and P0704 (1) = 3. 3. Control and communication wiring should be 300V UL minimum. 4. Communication wiring should be run with maximum separation possible from all other wiring. 5. Essential service mode operates the motor full speed (bypass) with no protection for the motor or system. 6. Ensure that automatic bypass will not damage the system before activating. 7. See Siemens publication SED2 VD NEMA Type 3R Bypass Operating Instructions (125-3377) for proper fuse and wire sizes. 8. See Siemens publication SED2 VD Startup, Operation and Maintenance Manual (125-3201) for SED2 VD input/output signal wiring details. igure 3. NEMA Type 3R Bypass Wiring Schematic. NEMA Type 3R Bypass Specification Input Voltage (3 phase) Temperature High-Temperature Model Humidity Table 4. NEMA Type 3R Bypass Specifications. 208V, 3 AC ±10% 230V, 3 AC ±10% Description 460V, 3 AC ±10% 575V, 3 AC ±10% Operating: 14 to 104 ( 10 C to 40 C), HT1 to 122 (50 C) Storage: 40 to 158 ( 40 C to 70 C) Operating: 14 to 122 ( 10 C to 50 C) Storage: 40 to 158 ( 40 C to 70 C) 0 to 95% rh, non-condensing Page 6 of 8 Siemens Building Technologies, Inc.

SED2 VD NEMA Type 3R Bypass Submittal Sheet Table 5. SED2 VD Specifications. Drive Specification Description Input voltage and power ranges 200V to 240V, 3 AC ± 10%. 1/2 hp to 60 hp (2.3 Amps to 154 Amps) (3 phase) 380V to 480V, 3 AC ± 10% 1/2 hp to 125 hp (1.2 Amps to 178 Amps) Amps 500V to 600V, 3 AC ± 10% 1 hp to 125 hp (2.3 Amps to 125 Amps) Input frequency Output frequency Power factor 47 Hz to 63 Hz 0 Hz to 150 Hz VD degree of efficiency 96% to 97% Switch-on current Auxiliary supply 24V Overload capacity Control method PWM frequency ixed frequencies Skip frequency bands Setpoint resolution Digital inputs (sink/source) Analog inputs Relay outputs Analog outputs Serial interface Protection level Temperature ranges Humidity Operational altitudes Protection features Standards CE conformity 0.9 total, 0.97 displacement Less than nominal input current Glavanically separated, unregulated auxiliary supply (18V to 32V) 100 ma 110% for 60 seconds Linear, parabolic and programmable V/f; and flux current control low-power mode 2k Hz to 16k Hz (adjustable in 2k Hz increments) 15 programmable 4 programmable 0.01 Hz digital 0.01 Hz serial 10 bit analog 6: fully programmable and scalable isolated digital inputs, switchable 2: 0 to 10 Vdc, 0/4 ma to 20 ma, can also be configured as digital inputs or Ni 1000 input 2: configurable 30 Vdc/5A (resistive), 250 Vac 2A (inductive) 2: programmable (0/4 ma to 20 ma or 0V to 10 Vdc) RS-485; Protocols: Siemens, P1 and Johnson, N2; Transmission rate: Up to 38.4k Baud IP20: NEMA Type 1 (with protective shield and gland plate installed) IP54: NEMA Type 12 (400V and 500V series only) Operating: 14 to 104 ( 10 C to 40 C) Storage: 40 to 158 ( 40 C to 70 C) 95% rh, non-condensing Up to 3280 ft (1000 m) above sea level without de-rating Under-voltage Over-voltage Overload Ground fault Short circuit Stall prevention Locked motor Motor over temperature l 2 t, PTC Over-temperature Parameter PIN protection UL, cul Conformity with EC Low Voltage Directive 73/23/EEC Siemens Building Technologies, Inc. Page 7 of 8

SED2 VD NEMA Type 3R Bypass Table 6. Order Worksheet. Item Qty. Designation Part Number Description Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Other product or company names mentioned herein may be the trademarks of their respective owners. 2004 Siemens Building Technologies, Inc. Siemens Building Technologies, Inc. 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 U.S.A. Your feedback is important to us. If you have comments about this document, please send them to technical.editor@siemens.com. Country of Origin: US Page 8 of 8