MEASUREMENT INSTRUMENTS

Similar documents
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Preset Counter signo 721

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Flexible Counter Series in DIN size 24 x 48 mm

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

4-Channel Thermometer / Datalogger

Nokeval. User's Manual Models 301 / 302 / 305

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

EBDSPIR-PRM, EBDSPIR-PRM-IP

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Transmitter Interface Program

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Drayton Digistat +2RF/+3RF

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Short information Parameters are programmed via front-side membrane keypad

TC-9102 Series Surface Mount Temperature Controllers

Back-UPS Pro 1300/1500 Installation and Operation

T0118 T2118 T3118. Instruction Manual

700/732 SERIES. 5mm HOUR METERS & COUNTERS. CURTIS INSTRUMENTS, INC. 200 Kisco Avenue, Mt. Kisco, NY Tel. (914) FAX (914)

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation.

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Points Position Indicator (PPI1) for Points Motors with Common Ground

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User s Manual Before using the inverter, you need to read and save the safety instructions.

AM / FM Tuner + RDS. Model: TU

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

DLP-PU/E Instruction Manual

DAB+ / FM Tuner Model: TU-201

PART 1 PRODUCT (GENERAL)...1.

OPERATING INSTRUCTIONS

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Electronic Control Devices The European Product Catalogue 2007

Electronic Pressure Switch EDS 3000

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

PD 100A. Printing data system

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

FACTORY AUTOMATION. Manual. Speed Monitor KHU8-DW-1.D

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

INSTALLATION AND OPERATION MANUAL

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

How To Program An Autodialer

IO-RM3 3-Stage Relay Module

Electronic Control Devices The European Product Catalogue 2007

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

FAQ s on Siemens Magmeters

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Point of view HDMI Smart TV dongle Mini RF Keyboard

Duct Humidity Transmitter

Series DFMT Digital Paddlewheel Flowmeter

=============================== WARNING

magnetronic GmbH Kreuzhofstr München Tel.: 089/ Fax: 089/ Battery control system DCC 6000

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

USER S MANUAL Kodiak Series Wireless Trail Camera

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Electrical connection

Digital Keypad Use s Manual

SNMP Web Management. User s Manual For SNMP Web Card/Box

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Installation and User Guide

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

WD-AMX Water Detection Controllers

PPM Users Manual Signature Software

RAINCONTROL LCD Special

PROCESS AUTOMATION MANUAL OVERSPEED/UNDERSPEED MONITOR KF**-DWB-(EX)1.D ISO9001

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Solar Controller / Battery Charger User s Manual

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Variable Preset Counter signo 723.1

Series 7500 Torque Sensor

focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V

Car Alarm Series 2 B 2 Buttons

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

T7560A,B,C Digital Wall Module

User Manual. Video Doorphone CDV-1020AQ

AutoRanging Digital MultiMeter

Transcription:

ALC 44 MEASUREMENT INSTRUMENTS 48X48 MM DIMENSION 600 KHZ SPEED READING 2 ROW, 4 DIGIT DISPLAY ENCODER A VE B MEASURING CHANNELS FUNCTIONAL EXTERNAL Z (RESET) INPUT FUNCTIONAL EXTERNAL HOLD INPUT QUADRATURE UP AND DOWN COUNTING 2 PIECES DOUBLE RELAY OUTPUT MAKE SELECTION ACCORDING TO SET-1 AND SET-2 PRESCALE CAN BE ADJUSTABLE (0,001-9999) DECIMAL BETWEEN 1ST AND 4TH STEP POINT 5 VDC OR 12 VDC ENCODER SUPPLY OUTPUT 11 DIFFERENT CONTROL OUTPUT MODE PASSWORD PROTECTION USER MANUAL

INDEX 1. TECHNICAL FEATURES.... 1 2. CONNECTIONS.... 2 3. DESCRIPTION OF FRONT PANEL.. 3 4. DEVICE PROGRAMMING.. 4 4.1. SET POINT INPUT (Set). 4 4.2. RELAY OUTPUT MODE (Type)... 4 4.3. ENTERING OF CONSTANT VALUE (Cons) 5 4.4. RELAY OUTPUT POSITIONS (out). 5 4.5. RELAY OUTPUT TIMES (t1 / t2). 5 4.6. ENTERING OF HYSTERESIS(hys) 6 4.7. POINT POSITION SELECTION (decp). 6 4.8. RESET with BUTTON (p.rst). 6 4.9. RESET with External Z Signal (Indh).. 7 4.10. ACTIVATING THE Hold INPUT (Hold)... 7 4.11. SELECTION Hold TYPE (H.typ).. 7 4.12. SELECTION SENSOR TYPE (S.Typ) 8 4.13. EDGE COUNTING OPTION (C.typ).. 8 4.14. KEEPING IN MEMORY WHEN THE POWER FAILS (rec.).... 8 4.15. PASSWORD SECURITY (Secu). 9 4.16. RETURN FACTORY DEFAULTS (F.def) 9 4.17. ANNEX A RELAY OUTPUT GRAPHIC (type Menu)... 10 5. CERTIFICATE of WARRANTY 13

42,8 mm ELECTRICAL CHARACTERISTICS SUPPLY VOLTAGE POWER CONSUMPTION SENSOR SUPPLY VOLTAGE CONNECTION INPUTS OUTPUTS PHYSICAL CHARACTERISTICS 1. TECHNICAL FEATURES 85-265 VAC 50/60 Hz Optional 24VDC /24 VAC 5.5 VA Maximum 5 VDC 100 ma (for TTL Sensor ) 12 VDC 100 ma (for Push-Pull Sensör) 2,5 mm² screw-clemens A/B Encoder Pulse Inputs (600 KHz speed reading) Z (external reset) Input Hold Input 2 pieces 250 VAC 3A (for Resistive Load) Relay DIMENSIONS WEIGHT MOUNTING 48 x 48 x 96 mm 200 gr. Upper and lower legs are fixed to the clipboard. RELATIVE HUMIDITY %80 up to 31 C, %50 up to 40 C STORAGE TEMPERATURE -10 UP TO 60 C OPERATING TEMPERATURE PROTECTION CLASS 0 UP TO 50 C IP 60 Front Panel, IP 20 Back panel DIMENSIONS 48 mm 48 mm Pano Dimension : 45 mm 45 mm - 1 -

2. CONNECTIONS SAFETY WARNINGS 1. Follow the instructions and warnings in the user guide. 2. Please check the type of power supply before connects energy to the device. 3. Please the device mounted on panel against dangers of fall, snap, shake during working. 4. Make Sensor connections without energy on the device; do not connect in any way during operation. 5. Make sure that is shielded cables between device and sensor. 6. Do not leave the device exposed to a heat source (solar, heater etc.) 7. ALC77 industrial control device is not suitable for use in the external environment, Use only room conditions. 8. Wipe with a damp cloth to clean the device, do not use water, thinner etc. 9. Comply with the limit values specified in the technical specifications for relay outputs. 10. The device cannot be changed by the user in the event of a fault, Please contact our technical service in case of failure. - 2 -

3. DESCRIPTION OF FRONT PANEL ALC44 device operates in 2 different modes: Programming mode Operating modu : Specifies the function used during programming. : Specifies the function used during operating. Display and Position LEDs 1. 4 Digit LED Display at Operating mode: Indication of counting At programming mode: Indication of program parameter 2. 7 Digit LED Display at Operating mode: Indication of Set value. At programming mode: Indication of program parameter 3. Out-1 output LED position: On while the power at Out-1. 4. Out-2 output LED position: On while the power at Out-2. 5. Set-1 Led position: On while Set-1 value is displayed in the bottom display 6. Set-2 Led position: On while Set-2 value is displayed in the bottom display. Button Functions 7. RESET Button at Operating mode: Used to reset of counted value. At programming mode: Using to exit without saving the entered value of the parameter and return to the operation mode. 8. PROG Button at Operating mode: Used to return to the menu. At programming mode: Used to save and enter menu parameter value. 9. Down Button at Operating mode: Used to in the bottom display to show the value of Set-1. At programming mode: Used to switch between the menus and decrease the value of the selected parameter. 10. Up Button at Operating mode: Used to in the bottom display to show the value of Set-2. At programming mode: Used to switch between the menus and decrease the value of the selected parameter. - 3 -

4. DEVICE PROGRAMMING Enter to the menu and Changing Parameters: For Switch to programming mode while device operating mode push ( menu will appear on the screen. ) button. Firstly s Switch between program menus with Down ( ) and up ( ) buttons. button is entered into for the menu to be changed. Changes are saved with prg ( ) button. Return to operating mode with Rst ( RST ) button. If password protection is activated at device, password must be entered. If password is correct, true message is displayed on the bottom line. Also password is incorrect, false is displayed. If Password is correct : true If Password is incorrect: false 4.1. Entering The Set Point to Device (Set) Menu is displayed firstly on the screen as prg button is pressed while operating mode. Menu of Set 2 is displayed while down button is pressed. The top row shows the name of the menu and bottom row also (yellow marked) selected value in menu content. Set 1, set 2 allows controlling to out1 and out2 relays. Move to the desired set point for setting. The rightmost digit starts flashing when prg button is pressed. Desired point is selected up and down button. Used to prg button for digits scrolling. Shifted to the left for one step when each press of the button, If pres the prg button when coming the rightmost digits, positive or negative value will be asked. Value is selected by up and down button then saved with prg button. If you do not want to save, you can exit with esc button. 4.2. Relay Output Mode (type) Type menu provides different relay outputs according to the set values entered. There are 11 different output types. Related detailed charts are in Annex-A. To select any output mode, enter the programming mode with prg button then enter the type menu. The right hand digit flashes when prg button is pressed and assign value with up-down button. Shifted to the left for one step when press of the prg button and save with prg button. So mode is selected. - 4 -

4.3. Entering Of Constant Value (cons) Cons Menu, allows the show of sensors with different resolutions on the screen and determines the value of each edge/pulse on the screen. By way of example, 0,025 constant value is entered to Cons Menu for the 25 micron-sensor or 0,005 constant value for 5 micron-sensor. So when sensor moves 100 mm, value of 100 is displayed on the screen. In order to Set to Cons menu, pressed to Prg button while operating mode and ound to Cons Menu with using up-down button. When pressed to prg button (While being cons menu), the right-hand digit of button row flashes. Set to wanted value with up-down button. Digit moves to the left while pressed to prg button. Then pressed to prg button again, this digit flashes. Digit position is set with up-down button. You press again Prg button, the digit is continuously flashing. Therefore the constant value is entered in. If you want to exit without saving, you can back to operating mode with rst button. 4.4. Relay Output Positions (Out) Out1 and out2 menus allow positions of the relays. The relay is inactive at close option, active while reached set point. And also the relay is active at open option, it will be inactive while reached set point. 4.5. Role Output Times (t1 / t2) Tout menus allow role output times according to entered times. If entered to time as zero, writes hold on the screen. Thus situated, Relays will be active during the set value is exceeded. In order to entered output time, if you press to prg button, found t1 or t2 menus with up-down button. When pressed prg button, the right-digit of button row flashes. Its value is set with up-down button. Each press of the button moves to the left in a digit. Then you can save them. Therefore point is fixed. - 5 -

4.6. Entering of Hysteresis (hys) Hysteresis value can be entered using this menu to device. Hysteresis value s purpose is prevent from vibration of relay contacts when device reaches the set point. After up to entered hysteresis value time, pulls the relay contacts or release. During hysteresis value, nothing done. Therefore a negligible value must be selected. In order to entered hysteresis value, should be entered programming mode with prg button and found hys menu with up-down button. The right-digit is flashing when pressed to prg button, you can set wanted value with up-down button. Each press of the button moves to the left in a digit. Then you can save them. 4.7. Point Position Selection (decp) Sensitivity of the value shown on the display is set here. Changing the location of point on the screen, the precision value (to be read after the point) is selected. In order to changing the position of the point, pressed to prg buton at operation mode. Found the Decp menu with up-down button. Prg button is pressed, the figures will flash. Point position is adjusted up-down button. Prg also is saved by pressing and Rst button to return to operating mode. 4.8. Reset With Button (p.rst) This menu ensures that the RST button at front panel is activated. When RST button is pressed for 2 seconds at operating mode, value on the display is reset or returned the offset value. In order to activate rst button, pressed to prg button at operating mode and found p.rst menu wit up-down button. When Prg button is pressed, one of on/off options will flash. If you chose ON with prg button, rst button will be active. - 6 -

4.9. Reset With External Z Signal (Indh) Resetting at device screen can be done with by applied from outside external an encoder Z signal or a switch when external Z input is activated. While you make active the Z input, select the edge you will make reset on. You can select one of rising and falling edges. If you don t want to use Z input, select to off option. In order to activate to Z input, pressed to prg button at operating mode and found rst inpt menu with up-down button. When Prg button is pressed, options will flash and made the selection with up-down button. Then saved it by prg button. 4.10. Activating The Hold Input (Hold) While hold input is active, value on the screen is fixed when coming the signal of hold input. If signal of hold input isn't cut, counting can not to be continued. While you select the hold input, also select the edge you will make reset on. You can select one of rising and falling edges. If you want to hold off input, select to off option. In order to select to hold Input, pressed to prg button at operating mode and found hold menu with up-down button. When prg button is pressed, options will flash and made the selection with up-down button. Then save it by prg button.. 4.11. Selection Hold Type (H.typ) H.type menu is selected counting in the background, when value of on the screen is fixed (while hold input is active). The value of on the screen is fixed, if hold signal is applied while cont option is active. When signal is interrupted, continue to counted value. In order to select hold type, pressed to prg button at operating mode and found h.type menu with up-down button. When prg button is pressed, options will flash and made the selection with up-down button. Then saved it by prg button and Returned with rst button to operating mode. - 7 -

4.12. Selection Sensor (Npn/Pnp) Type (S.typ) The used sensor type can be selected from this menu. The sensor output signal is selectable as NPN or PNP. In order to selected sensor type, press to prg button at operating mode and fount S.typ menu with up-down button. When prg button is pressed, options will flash and made the selection with up-down button. Then saved it by prg button and return with rst button to operating mode. 4.13. Edge Counting Option (C.typ) The edge counting value of A and B encoder signals is selected with edge counting option. Value of counting option is 1, 2 and 4. If the incremental encoder is connected, 1 value is selected in order to see the value of the on-screen as the pulse. If the linear encoder is connected, 4 (quadrature mod) is selected for better accuracy measurement. In order to changed edge counting option, pressed to prg button at operating mode and fount C.typ menu with up-down button. When Prg button is pressed, options will flash and made the selection with up-down button. Then saved it by prg button and Returned with rst button to operating mode. 4.14. Keeping In Memory When The Power - 8 - Fails (rec.) Rec menu enables to keep in memory the last value on the screen even if the energy is cut off and must be selected on for this option. So the final value will be memorized when energy is cut off and resumes again when energy comes back. Recording process will not be stored to device memory while off is selected, and then value will start from zero. In order to change data menu, press to prg button at operating mode and found rec. Menu with up-down button. Then saved it by prg button and returned with rst button to operating mode.. - 8 -

4.15. Password Security (Secu) Password security enables that unauthorized persons is prevented to change the parameters of the menu. If Secu menu is nset position, password is not required while setting the set values. Password is required for others setting. While Secu menu is all position, password is required for any setting changes. While Secu menu is off position, password security is not active. In order to turn on Secu menu, pressed to prg button at operating mode and found Secu Menu with up-down button. Then save it by prg button. Secu menu includes to SPS.1 and SPS.2 menus. You can set all passwords by these menus. SPS.1 menu enables to set password for all setting-up and SPS.2 menu enables set password of only set values. When prg button is pressed at menu secrees, the right-digit of bottom row is flashing and changed value with up-down button. When Pressed to prg button, moves to the left in a digit. So you can set the value with up-down button and save them when pressed to prg button at third digit. So password is defined. 4.16. Return Factory Defaults (F.def) F.def menu enables to return the first fabrication settings of device. At this situated, all device setting will change, for this reason important settings should be saved previously. Device will require the password for returning to factory defaults and this password is 454. In order to return to factory defaults, pressed to prg button at operating mode and found to F.def menu with up-down button. When prg button is pressed at menu secrees, The right-digit of bottom row is flashing and changed value with up-down button. When pressed to prg button, moves to the left in a digit and you can set it as 454 and pressed to prg button. So device will return to factory defaults. - 9 -

4.17. Annex A Relay Output Graphic (type Menüsü) Type 0 While Out mode is 0(zero), don t observed any output at Out-1 and Out-2. Type 1 In this mode; when count value rises above the level of the SET-1, OUT- 1 gives the out (so Relay-1 is ON). If TOUT-1 is selected (Time of Relay- 1) HOLD, OUT-1 is active until count value falls bottom level of SET-1. When count value rises above the level of the SET-2, OUT-2 is give the out and If TOUT-2 is selected HOLD, OUT-2 is active until count value falls bottom level of SET-2. TOUT-1 and TOUT-2 are selected as term, OUT-1 and OUT-2 will active during this time. Type 2 In this mode, when count value rises above the level of the SeT-1, OUT-1 is active and above the level of SET-2, OUT-2 is active. Relays will be active even goes down below the set values without RESET. Relays give outs during this time, if entered times for outs. Relays don t give outs until RESET. Type 3 When count value rises above the level of the SeT-1, OUT-1 is active and rise above level of the SET-2, OUT-2 is active. So count value will be fixed. Even if encoder s pulse is at device without RESET, count value does not change but count value and outs will be reset. - 10 -

Type 4 OUT-1 depends to OUT-2 and TOUT-2 should be selected as term. When count value rises above the level of the SET-1, OUT-1 is active and rises above level of the SET-2, OUT-2 is active. So count value will be fixed. Outputs and count value will be reset at the end of TOUT-2 period. Type 5 Output-4 is continuing to count after level of set-2 value. OUT-1 depends to OUT-2 and TOUT-2 should be selected as term. When count value rises above the level of the SET-1, OUT-1 is active and rises above level of the SET-2, OUT-2 is active. So Count value will be fixed. Outputs and count value will be reset at the end of TOUT-2 period. Type 6 When count value rises above the level of the SET-1, OUT-1 is active and rise above level of the SET-2, OUT-2 is active. TOUT terms while selected HOLD, there is no outputs even to count value falls bottom level of SET values. Outputs will be reset when count value reaches zero (OFFSET), besides count value and outs will be reset when comes RESET. Type 7 When count value rises above the level of the SET-1, OUT-1 is active and then relay is inactivated end of the TOUT-1 period. If TOUT-1 term is selected as HOLD, OUT-1 will be inactive when count value goes down below the level of the SET-1 and rises above the level of the SET- 2, OUT-2 is active. It will be inactive end of TOUT-2 period. If TOUT-2 term is selected as HOLD, OUT-2 is not active even to count value is below the level of SET-2 value. OUT-2 will be zero when count value reaches zero (OFFSET). Besides count value and outs will be reset when comes RESET. - 11 -

Type 8 While count value is below level of Set-1, Out-1 is active and then Out-1 is inactive when on top of it. Out-2 is active when on top of SET-2 value and OUT-2 is inactive after reaching below the SET-2 value. Count value and outs will be reset when comes RESET. Type 9 At this mode, TOUT-2 should be selected as term. OUT-1 is active during TOUT-1 period at count value exceeds the each value of the SET-1 and OUT-1 is inactive at the end of TOUT-2 period. Count value and outs will be reset when comes RESET. Type 10 TOUT times should be selected as HOLD. OUT-1 is active until count value reaches the value of the SET-2 and OUT-2 is inactive when rehashes. OUT-2 is active until count value reaches the value of the SET-1 and OUT-1 is inactive when rehashes. - 12 -

5. CERTIFICATE OF WARRANTY Product : ALC44 85/265 VAC 24 VAC/DC TTL Push Pull Serial No: This product is guaranteed for two years against manufacturing defects. Conditions out of the warranty: - Mechanical damage - Shipping damage - Users error Other situations are covered by the manufacturer's warranty. Signature and Stamp - 13 -

ATEK SENSOR TECHNOLOGY A.S. Cevizli Mah. Bagdat Cad. Guven Sok. No:11 TR-34846 Maltepe / Istanbul - TURKEY Tel: +90 (216) 399 44 04 Fax : +90 (216) 399 44 02 Web: E-Mail: www.ateksensor.com info@ateksensor.com