LIMBURGzaal Dressing rooms: There are 3 dressing rooms dedicated to the LIMBURGzaal. Each room has at least 1 hand basin. nr14. ±4 persons ±1m 1 douche 1 toilet nr15. ±3 persons ±8m 1 douche nr16. ±3 persons ±8m 1 douche Dressing rooms 15 en 16 have toilets on the gallery Each dressing room has a refrigerator. Do you need more dressing rooms? Ask the technical department. nr9. ±10 persons ±18m 1 douche 1 toilet nr10. ±10 persons ±0m 1 douche 1 toilet Each dressing room has a screen for stage view and regular tv. In all dressing rooms you can listen to the stage sound and paging system. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-1 -
Tuning chamber: Here for is a separate room available (45m ). Be aware! This room will be shared with other venues! Laundry: Washers, dryers, iron and iron board is available, shared with other venues. FOH: FOH is in the middle of the audience under the balcony. Control room: Control room is behind the last row on the balcony. Dressing room paging system: The paging system microphone is positioned stage left upstage. You can listen to the paging system in all dressing rooms, gallery s and artist foyer. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015 - -
Stage: The LIMBURGzaal is a multi-purpose-venue, contact our technical department for more possibilities Standard situations: Theatre stage Pop stage Main curtain Movement: travels Operation: Manually Color Crème Draperies Legs en borders Night blue velour Minimum horizontal opening Maximum horizontal opening 1m 18m NONE (possible: back cloth on rail) Legs en borders Night blue velour Normal opening Maximum horizontal opening 1m 18m Portal bridge Maximum height: 10m Minimum height: 6,5m Front bridge Maximum height: 9,5m Minimum height: 7,5m Stage floor Height adjustable: 0-1,50m Normal height 0,60m Width: 0m Depth: 10m Max. floor load: 750 kg/m No stairs from audience to stage NONE Maximum height: 9,5m Minimum height: 7,5m Height adjustable: 0-1,50m Normal height 0,60m Width: 0m Depth: 10m Max. floor load: 750 kg/m Stairs from audience to stage possible Draperies Height x Width Legs 9,5m x 4,m Night blue - velour Borders 3m x 18m Night blue - velour Backcloth 9,5m x 18m on rail Night blue - velour Side tabs 9,5m x 11m panels Night blue - velour Cyclorama 9,5m x 18m White - Linen Gauze 6m x 18m Black Gauze 6m x 18m White In all legs can be put in a pipe. Stage floor Dance floor The stage floor can be adjusted in each height in 6 separate parts. The complete stage can be covered with a black dance floor. Resilient flooring For dance acts there can be put in a resilient flooring. Width: 1m Depth: 10m Work platform Genie IWP30S-AC Max. working height 10,8m Max. platform height 9m. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-3 -
Top view: m Stage entrance 0m Stage entrance m 18m,5m 5,5m Side view: Tech Sound reflector Sound reflector Control room Max. 13m dressing room 00 1,50 0-0,60 stock stock 8m 5,5m 7m mm 4m Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-4 -
Seating area: Zaalregie Volgspotplaatsen seating s (theater-stage): pitches (pop-stage): Lower stalls 18 chairs Plateau 4 chairs Balcony 144 chairs + + Total 350 1300 Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-5 -
Logistics: Loading dock The loading dock is indoor. 1 loading platform equal to stage floor in highest position. truck elevators (shared with other venues). Maximum measurements truck: Length:,5m Width:,5m Height: 4m Max. load: 40 ton 1 elevator from artist entrance to dressing room gallery. Length: 3m Width: m Height: m Max. load: 3,5 Ton Parking Theatre Heerlen has only one parking lot for a couch. There are no parking places for passenger cars. If possible one truck can park in the load-in area. Stage entrance Measurements doors for décor. Width:,5m Height:,5m doors for people.. 1 stage right back wall 1 stage left upstage If the stage isn t in its highest position you have to bring the décor on stage trough a elevator. Measurements elevator Length: 5,1m Width: 3,8m Height: 3,1m Max. load:,5 ton Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-6 -
Stage: 4m 0m 1m 4m 0,8m Fixed height 0m 7m Height -0,60m / 1,50m Height -0,60m / 1,50m Height 0m / 1,50m 7,80 4m Height -0,60m / 1,50m Height -0,60m / 1,50m Height -0,60m / 1,50m 4m 1,4 Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-7 -
Rigging: Silicon Theatre Scenery Automated Flying System 45 Bars (max. 500kg. Point load 50kg.) Length 18m maximum height 13,1m 1 Side bar left (side cloth), 10m from centre line. (max. 500kg. Point load 50kg.) Length 11m maximum height 13,1m 1 Side bar right (side cloth), 10m from centre line. (max. 500kg. Point load 50kg.) Length 11m maximum height 13,1m 1 transport bar portal bridge, fixed speed. (max. 80kg.) Length 1m maximum height 13.1m 1 border bar to hide portal bridge, fixed speed. (max. 50kg.) Length 0m maximum height 13.1m bars above first row,, fixed speed. (max. 500kg. Point load 50kg.) Length 1m maximum height 13.1m 6 winches movable across whole hall, adjustable speed. (max. 35kg each winch) 1 Chain hoists movable across whole hall, adjustable speed. (max. 650kg each hoist, 800kg in some cases) 6 Chain hoists (PA) fixed speed. (max. 1 ton each hoist) AV hoist for transport of large sound desks to FOH position. (max. 1000kg) Always contact the technical department for each rigging plot! Control Connection control desk Local control Stage right upstage Stage left upstage (regular position) FOH Stage left upstage Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-8 -
3 Forstage bar 6,40m Z1 33 -,0m 6,60m Z -,00m 34* 6,80m 35* 7,00m FT -1,80m Fries 36 37 7,40m Bars (500kg) 1 0,0m 39 7,80m 3 0,60m 41 8,0m 4* 0,80m 4 8,40m 5* 1,00m 43 8,60m 6 1,0m 44 8,80m 7 1,40m 8 1,60m 46 9,0m 9 1,80m 47 9,40m 10,00m 48 9,60m 11,0m 49 9,80m 1,40m 50 10,00m 13,60m Sidebars (500kg) 14,80m ZL Black-cloth 15 3,00m ZR Black-cloth 16 3,0m winches (50kg) 17 3,40m L1 18 3,60m L 19* 3,80m L3 0* 4,00m L4 1 4,0m L5 4,40m L6 3 4,60m Chain hoists (500kg) 4 4,80m T1 5 5,00m T 6 5,0m T3 7 5,40m T4 8 5,60m T5 9 5,80m T6 30 6,00m Bar 1 to main curtain = 1,35m 31 6,0m bar 50 to backwall = 0,7m Stage height is adjusteble. Measurements from nominal level. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-9 -
Orchestra shell: For musical acoustical performances Theatre Heerlen has a sophisticated orchestra shell for improvement of the acoustics. There are different set-ups, depending on the wishes and size of the orchestra. Large Measurements: Width downstage: 15m Width upstage : 1m Depth orchestra shell 1m Depth stage edge: 13,5m Medium Measurements: Width downstage: 14m Width upstage: 1m Depth orchestra shell: 8m Depth stage edge: 9.5m Small Measurements: Width downstage: 1m Width upstage: 11m Depth orchestra shell: 5,5m Depth stage edge: 7m Acoustics: The LIMBURGzaal has an adjustable electro-acoustic system. The LIMBURGzaal is designed for amplified performances. Speech establishment and reverb times can be adjust with this system. (SIAP) Reverberation times Amplified performance (system off) Speech small, musical performances Medium, musical performances Large, musical performances Large choir, church Maximum reverberation RT30=0,7s RT30=0,7s RT30=1,4s RT30=1,6s RT30=1,8s RT30=,0s RT30=,7s Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-10 -
Electricity: General 15A CEE-form (5pole) 3A CEE-form (5pole) 16A CEE-form (5pole) 16A Shuco Sound 63A CEE-form (5pole) 16A Shuco 4x 6x 1x x x stage right upstage (stage level) x stage left upstage (side bridge) 3x stage right (side bridge) 3x stage left (side bridge) FOH several connections. stage right upstage stage left upstage several connections. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-11 -
Light: Fixtures, as indicated on lightning plot, permanently rigged, not moveable. Dimmers 96x 3kW Sinewave Dimming (ETC) Light computer Grand MA: Full-size en Ultra-light DMX connections Freely to patch through patch-panel. Connections in FOH, control room, stage en bridges. Follow spot On balcony left and right. x Robert Juliat Korrigan 1,kW HMI. Own Follow spots can be positioned on the balcony or front bridge. Dimmer connections on stage No connection, only local rack. Cyclorama connected to local rack. 36x 3kW Sinewave Dimming 6x 5kW Sinewave Dimming Fixtures 1kW Plano Conflex kw Plano Conflex 1kW Zoomspot 16º-35º kw Zoomspot 10º-0º kw Zoomspot 15º-40º 1kW Cyclorama Robert Juliat Robert Juliat Robert Juliat Robert Juliat Robert Juliat ADB Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-1 -
LIMBURGzaal -03-013 197 198 199 00 01 0 03 04 05 06 07 08 09 10 11 1 13 14 15 16 17 18 19 0 Zijbrug links Horizon-Unit Zijbrug rechts 70 69 68 67 66 65 64 63 84 83 8 81 80 79 78 77 54 55 85 86 87 88 89 90 91 9 93 94 95 96 53 9 30 31 3 33 34 35 36 37 38 39 40 Portaalbrug 41 4 43 44 45 46 47 48 49 50 51 5 56 59 60 61 6 76 75 74 73 15 16 17 18 19 0 1 3 4 5 6 7 8 Zaalbrug beneden 58 1 3 4 5 6 7 8 9 10 11 1 13 14 Zaalbrug boven 57 71 7 Dimmer 3kW PC 1kW PC kw Zoom 1kW (16-36' Zoom kw (15-40') Zoom kw(10-0') Zaallicht 504-51 Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-13 -
Sound: The sound system is optimized for our theatre, as well for tuning as for sound direction. It s not possible to adjust equalization and delay by the user. Sound system, theatre setup Line array Subwoofers Center cluster Fill-inn Front-fill Processing en security Router/delay Meyer Sound M1D Martin Audio WS18X Martin Audio WT3 Martin Audio WT3 Meyer Sound M1D XTA (not accessible) Mediamatrix Nion 6 (6 in/14 out) Sound system, concert setup Line array Martin Audio W8LC Martin Audio W8LCD Subwoofers Martin Audio WLX Center cluster Martin Audio WT3 Fill-inn Martin Audio WT3 Front-fill Martin Audio W0,5 Processing en security XTA (not accessible) Surround system KEFF surround loudspeakers. Controllable in 4 lines (left, left behind, right behind, right). Multicore FOH stage left/right 48/1 Analog and x MADI Coaxial Control room stage right 1/1 Analog 1 extra tie-lines, FOH, Stage, Amplifier room, control room. Isolated earth. Cat6 network for digital connections! Intercom ASL A en B party line connections to stage, control room, FOH, follow spot position and bridges. Clearcom Wireless Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-14 -
Use of radio frequencies RED, Do NOT Use in theatre Heerlen: GREEN, approved to use in Theatre Heerlen 195.000 10.000 Low level audio connections 450.000-470.000 Mobile communication 470.000 494.000 Low level audio connections 494.000 50.000 DVB-T 50.000 518.000 Low level audio connections 518.000 56.000 DVB-T 56.000 550.000 Low level audio connections 550.000 558.000 DVB-T 558.000 574.000 Low level audio connections 574.000 58.000 DVB-T 58.000 608.000 Low level audio connections 608.000 614.000 Radio astronomy, 614.000 791.000 Low level audio connections All frequency s above not for professional use!!! 791.000 81.000 Mobile communication Frequency 801.100 Transmitter Rabozaal Frequency 805.050 Transmitter Limburgzaal Frequency 813.300 Transmitter INGzaal 83.000 83.000 Low level audio connections (Duplex Center Gap) 83.000 960.000 Mobile communication Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-15 -
Video: Camera Fixed (dome) camera to stage. Screens No fixed screens. Coax connections Freely to patch through patch-panel. Connections in FOH, control room, stage en bridges. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-16 -