There are 3 dressing rooms dedicated to the LIMBURGzaal. Each room has at least 1 hand basin.

Similar documents
Schouwburg & Filmtheater Agnietenhof Venue: 4000 AN Tiel. info@agnietenhof.nl techniek@agnietenhof.nl

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Stadsschouwburg Amsterdam Rabozaal website technical rider - 13th of may 2011

PRODUCTION SPECIFICATIONS

Theater De Meervaart Amsterdam Red Hall (Rode Zaal) and Blue Hall (Blauwe zaal)

Event Planner/Venue Specialist Phone:

STAGE SPECIFICATIONS. Newberry Opera House

HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER CAPACITY. Stalls: 257 Seats per row: 22(Max)

Technical Specifications Lyric Theatre Belfast Danske Bank Stage

Standard working hours Lunch 12:30-13:00 Diner 17:00-19:00. Theaters Tilburg Schouwburg. Technical Specifications Theaters Tilburg Schouwburg.

Douglas J. Cardinal Performing Arts Centre. Information and Technical Specifications

The theatre cafeteria can provide snacks during the morning and coffee in the afternoon for 500 persons.

TECHNICAL RIDER

Theaters Tilburg - Concertzaal. Address

TECHNICAL SPECIFICATIONS Paramount website: Paramount

SHUBERT THEATER 247 College Street, New Haven, CT

FOOTHILL COLLEGE FINE ARTS FACILITIES OFFICE

Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University

TECHNICAL INFOS CAPACITY 2 STAGE 2 TECHNICAL ROOF GRID (NOT YET AVAILABLE) 2 STAGE CURTAINS 3 FOLLOWSPOTS PLATFORM 3 ELECTRIC INSTALLATIONS 3

Artist: Michael and Amy Rider: Corporate - Grand Pianos

Rehearsal Date(s) Start Time Estimated Closing Latest Closing. Doors

L ORATORIO D AURELIA. Technical Rider. Administration: Didier Bendel Cell phone:(0049) (0) didierbendel@gmx.

TECHNICAL SPECIFICATIONS.

Les Docks / Av. de Sévelin Lausanne! Technical Rider

J. W. ENNIS AUDITORIUM CENTENNIAL SECONDARY SCHOOL WELLAND, ONTARIO THEATRE TECHNICAL INFORMATION MARCH 29, 2013

Meydenbauer Center Audio Visual Services & Price Guide. Provided by Audio Visual Factory Inc.

Existing Stage Facilities at LCSD s Performance Venues

The Civic Hall in Bedworth Technical Specification

CIRCUS INCOGNITUS. Technical Rider Version: April 15, 2008

CARMEN R in the Norwich Theatre Royal, UK

MEETING PACKAGES 400 LEVEL

Theaters Tilburg - Concertzaal. Address

Copyright all rights reserved K-array surl

Ministry of the Environment Decree on accessible building

Watford s Major Entertainment and Hospitality Venue

Contacts. The Space. Lx Kit List. Sound Kit List. Stage Management. Health & Safety Policy

TECHNICAL SPECIFICATIONS

Introduction. Meeting Spaces. Hynes Audio Services

CORONET LONDON / Technical Information Pack (Updated - 1 st January 2015)

Technical Specifications Version

Théâtre de Suresnes JEAN VILAR presents RAYAHZONE

Divadlo Inspirace (Ints-per-ats-zay)

Site Plan. Parking. Main Auditorium. Large Auditorium. Lobby. Parking. Small Meeting Room. Dock & Broadcast Truck Bay

Wentz Concert Hall and Fine Arts Center 171 E. Chicago Avenue Naperville, IL Existing Electrical Systems Will Lesieutre

University of California, San Diego CAL IT 2

UCLA Department of World Arts and Cultures Glorya Kaufman Dance Theater (Room 200) Technical Information

Acoustical Design of a Multi-Purpose Hall for Natural and Amplified Sound

Direct and Reflected: Understanding the Truth with Y-S 3

A laundry with washer, dryer, deep sink, sewing machine, full length mirror, steamer, and ironing equipment is also available.

EAST TENNESSEE STATE UNIVERSITY FINE ARTS CLASSROOM BUILDING SBC NO. 166/ PROGRAM CONFIRMATION AND REFINEMENT SESSION NO.

Adress: Teatertorvet DK Horsens Denmark. Postal adress: P.O.Box DK 8700 Horsens. Phonenr, etc..

Theatre Manager: Linda Aitken (03) ,

What is Public Addres?

Bradford Odeon. Tim Ronalds Architects

CAD STANDARDS Version 2 VENUE AND PRODUCTION DRAWINGS

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

QUICK START GUIDE. Thank you for purchasing the ButtKicker Kit. This guide will help you quickly set up your new ButtKicker Kit Contents: BK-Kit-4

Stage Manager s Guide

Reynolds Performance Hall Facility Regulations and Fee Schedule

DESIGN CRITERIA FOR ACOUSTIC ENHANCEMENT SYSTEMS Ben Kok, Wim Prinssen Systems for Improved Acoustic Performance Uden, The Netherlands

TEATR GROTESKA ul. SKARBOWA KRAKÓW TEL groteska@groteska.pl Update

ELECTRONIC SOUND ENHANCEMENT SYSTEM IN THE MULTIFUNCTIONAL HALL TÓNBERG IN AKRANES, ICELAND

BRUXELLES ROOM. Total seats capacity 30. Total standing capacity. Total available seats / available armchairs. Hall qualitative level

The Theatre Dictionary

offices 0/1/2/3/4/5/6

Acoustics of the Teatro Arcimboldi in Milano. Part 2: Scale model studies, final results

Telepresence T3 Room recommendations

The Simulation of Acoustics by ODEON in the Acoustic Design. of Assembly Hall

Tallinn University School

One of the most incredible places on earth, Rolling Stone Magazine

Perth Concert Hall. Technical and Production Information

Order form for additional stand equipment and services 2012

MM-4XPD I clear. to the point. DIRECTIONAL MINIATURE SELF-POWERED LOUDSPEAKER

JdB Sound Acoustics Presents

The Swingle Singers RIDER PART 1: TECHNICAL REQUIREMENTS A Cappella Show

PRODUCTION SPECIFICATIONS THE MANÈGE (RIDEHUSET)

E SERIES ENTASYS 200 VERSATILE TWO-WAY COLUMN POINT SOURCE SYSTEMS. Application Guide. Part 2: Case Studies. 1 ENTASYS 200 Case Studies

Blair School of Music

accessibility standard

CASE STUDY. Sarakasi Theatre Nairobi, Kenya Room Acoustical Measurements and Modelling. Africa Room Acoustics DIRAC and ODEON

A1.5 Classroom Standards

Order form for additional stand equipment and services 2013

Sim Center Mentor Simulation Floorplans and Center Layouts

Production Services Department

Use of Facilities Agreement/User Contract Saemann Student Center, Conferences & Events

Wave Field Synthesis

PROJECT WORKPLACE DEVELOPMENT

Building Technology and Architectural Design. Program 4th lecture Case studies Room Acoustics Case studies Room Acoustics

A/V and Video Conference Standards for Teaching and Learning Rooms.

Technical Specifications

YORK BUDGET. Actual Cost

THEATRE USER INFORMATION GUIDE

Design Scenario Interior Design STAR Event

Broadway Theatre refurbishment

Lower Level (Level L) Exhibit Halls A, B & C

STADSSCHOUWBURG UTRECHT... 5 MAIN AUDITORIUM... 7 MARLEY DANCE FLOOR MASKING STAGE RAISERS ADDRESS AND DRIVING DIRECTIONS...

GOLD ENTERTAINMENT. We supply, install and hire all types of sound, lighting and audio-visual equipment.

Signage. Information / Admissions Desk. Gift Shop. Atrium. Scope Responsibility Architecture / Exhibit Design. Notes. Responsibility.

CONCERT HALL TECHNICAL SPECIFICATIONS

Index Product catalogue

Transcription:

LIMBURGzaal Dressing rooms: There are 3 dressing rooms dedicated to the LIMBURGzaal. Each room has at least 1 hand basin. nr14. ±4 persons ±1m 1 douche 1 toilet nr15. ±3 persons ±8m 1 douche nr16. ±3 persons ±8m 1 douche Dressing rooms 15 en 16 have toilets on the gallery Each dressing room has a refrigerator. Do you need more dressing rooms? Ask the technical department. nr9. ±10 persons ±18m 1 douche 1 toilet nr10. ±10 persons ±0m 1 douche 1 toilet Each dressing room has a screen for stage view and regular tv. In all dressing rooms you can listen to the stage sound and paging system. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-1 -

Tuning chamber: Here for is a separate room available (45m ). Be aware! This room will be shared with other venues! Laundry: Washers, dryers, iron and iron board is available, shared with other venues. FOH: FOH is in the middle of the audience under the balcony. Control room: Control room is behind the last row on the balcony. Dressing room paging system: The paging system microphone is positioned stage left upstage. You can listen to the paging system in all dressing rooms, gallery s and artist foyer. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015 - -

Stage: The LIMBURGzaal is a multi-purpose-venue, contact our technical department for more possibilities Standard situations: Theatre stage Pop stage Main curtain Movement: travels Operation: Manually Color Crème Draperies Legs en borders Night blue velour Minimum horizontal opening Maximum horizontal opening 1m 18m NONE (possible: back cloth on rail) Legs en borders Night blue velour Normal opening Maximum horizontal opening 1m 18m Portal bridge Maximum height: 10m Minimum height: 6,5m Front bridge Maximum height: 9,5m Minimum height: 7,5m Stage floor Height adjustable: 0-1,50m Normal height 0,60m Width: 0m Depth: 10m Max. floor load: 750 kg/m No stairs from audience to stage NONE Maximum height: 9,5m Minimum height: 7,5m Height adjustable: 0-1,50m Normal height 0,60m Width: 0m Depth: 10m Max. floor load: 750 kg/m Stairs from audience to stage possible Draperies Height x Width Legs 9,5m x 4,m Night blue - velour Borders 3m x 18m Night blue - velour Backcloth 9,5m x 18m on rail Night blue - velour Side tabs 9,5m x 11m panels Night blue - velour Cyclorama 9,5m x 18m White - Linen Gauze 6m x 18m Black Gauze 6m x 18m White In all legs can be put in a pipe. Stage floor Dance floor The stage floor can be adjusted in each height in 6 separate parts. The complete stage can be covered with a black dance floor. Resilient flooring For dance acts there can be put in a resilient flooring. Width: 1m Depth: 10m Work platform Genie IWP30S-AC Max. working height 10,8m Max. platform height 9m. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-3 -

Top view: m Stage entrance 0m Stage entrance m 18m,5m 5,5m Side view: Tech Sound reflector Sound reflector Control room Max. 13m dressing room 00 1,50 0-0,60 stock stock 8m 5,5m 7m mm 4m Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-4 -

Seating area: Zaalregie Volgspotplaatsen seating s (theater-stage): pitches (pop-stage): Lower stalls 18 chairs Plateau 4 chairs Balcony 144 chairs + + Total 350 1300 Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-5 -

Logistics: Loading dock The loading dock is indoor. 1 loading platform equal to stage floor in highest position. truck elevators (shared with other venues). Maximum measurements truck: Length:,5m Width:,5m Height: 4m Max. load: 40 ton 1 elevator from artist entrance to dressing room gallery. Length: 3m Width: m Height: m Max. load: 3,5 Ton Parking Theatre Heerlen has only one parking lot for a couch. There are no parking places for passenger cars. If possible one truck can park in the load-in area. Stage entrance Measurements doors for décor. Width:,5m Height:,5m doors for people.. 1 stage right back wall 1 stage left upstage If the stage isn t in its highest position you have to bring the décor on stage trough a elevator. Measurements elevator Length: 5,1m Width: 3,8m Height: 3,1m Max. load:,5 ton Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-6 -

Stage: 4m 0m 1m 4m 0,8m Fixed height 0m 7m Height -0,60m / 1,50m Height -0,60m / 1,50m Height 0m / 1,50m 7,80 4m Height -0,60m / 1,50m Height -0,60m / 1,50m Height -0,60m / 1,50m 4m 1,4 Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-7 -

Rigging: Silicon Theatre Scenery Automated Flying System 45 Bars (max. 500kg. Point load 50kg.) Length 18m maximum height 13,1m 1 Side bar left (side cloth), 10m from centre line. (max. 500kg. Point load 50kg.) Length 11m maximum height 13,1m 1 Side bar right (side cloth), 10m from centre line. (max. 500kg. Point load 50kg.) Length 11m maximum height 13,1m 1 transport bar portal bridge, fixed speed. (max. 80kg.) Length 1m maximum height 13.1m 1 border bar to hide portal bridge, fixed speed. (max. 50kg.) Length 0m maximum height 13.1m bars above first row,, fixed speed. (max. 500kg. Point load 50kg.) Length 1m maximum height 13.1m 6 winches movable across whole hall, adjustable speed. (max. 35kg each winch) 1 Chain hoists movable across whole hall, adjustable speed. (max. 650kg each hoist, 800kg in some cases) 6 Chain hoists (PA) fixed speed. (max. 1 ton each hoist) AV hoist for transport of large sound desks to FOH position. (max. 1000kg) Always contact the technical department for each rigging plot! Control Connection control desk Local control Stage right upstage Stage left upstage (regular position) FOH Stage left upstage Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-8 -

3 Forstage bar 6,40m Z1 33 -,0m 6,60m Z -,00m 34* 6,80m 35* 7,00m FT -1,80m Fries 36 37 7,40m Bars (500kg) 1 0,0m 39 7,80m 3 0,60m 41 8,0m 4* 0,80m 4 8,40m 5* 1,00m 43 8,60m 6 1,0m 44 8,80m 7 1,40m 8 1,60m 46 9,0m 9 1,80m 47 9,40m 10,00m 48 9,60m 11,0m 49 9,80m 1,40m 50 10,00m 13,60m Sidebars (500kg) 14,80m ZL Black-cloth 15 3,00m ZR Black-cloth 16 3,0m winches (50kg) 17 3,40m L1 18 3,60m L 19* 3,80m L3 0* 4,00m L4 1 4,0m L5 4,40m L6 3 4,60m Chain hoists (500kg) 4 4,80m T1 5 5,00m T 6 5,0m T3 7 5,40m T4 8 5,60m T5 9 5,80m T6 30 6,00m Bar 1 to main curtain = 1,35m 31 6,0m bar 50 to backwall = 0,7m Stage height is adjusteble. Measurements from nominal level. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-9 -

Orchestra shell: For musical acoustical performances Theatre Heerlen has a sophisticated orchestra shell for improvement of the acoustics. There are different set-ups, depending on the wishes and size of the orchestra. Large Measurements: Width downstage: 15m Width upstage : 1m Depth orchestra shell 1m Depth stage edge: 13,5m Medium Measurements: Width downstage: 14m Width upstage: 1m Depth orchestra shell: 8m Depth stage edge: 9.5m Small Measurements: Width downstage: 1m Width upstage: 11m Depth orchestra shell: 5,5m Depth stage edge: 7m Acoustics: The LIMBURGzaal has an adjustable electro-acoustic system. The LIMBURGzaal is designed for amplified performances. Speech establishment and reverb times can be adjust with this system. (SIAP) Reverberation times Amplified performance (system off) Speech small, musical performances Medium, musical performances Large, musical performances Large choir, church Maximum reverberation RT30=0,7s RT30=0,7s RT30=1,4s RT30=1,6s RT30=1,8s RT30=,0s RT30=,7s Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-10 -

Electricity: General 15A CEE-form (5pole) 3A CEE-form (5pole) 16A CEE-form (5pole) 16A Shuco Sound 63A CEE-form (5pole) 16A Shuco 4x 6x 1x x x stage right upstage (stage level) x stage left upstage (side bridge) 3x stage right (side bridge) 3x stage left (side bridge) FOH several connections. stage right upstage stage left upstage several connections. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-11 -

Light: Fixtures, as indicated on lightning plot, permanently rigged, not moveable. Dimmers 96x 3kW Sinewave Dimming (ETC) Light computer Grand MA: Full-size en Ultra-light DMX connections Freely to patch through patch-panel. Connections in FOH, control room, stage en bridges. Follow spot On balcony left and right. x Robert Juliat Korrigan 1,kW HMI. Own Follow spots can be positioned on the balcony or front bridge. Dimmer connections on stage No connection, only local rack. Cyclorama connected to local rack. 36x 3kW Sinewave Dimming 6x 5kW Sinewave Dimming Fixtures 1kW Plano Conflex kw Plano Conflex 1kW Zoomspot 16º-35º kw Zoomspot 10º-0º kw Zoomspot 15º-40º 1kW Cyclorama Robert Juliat Robert Juliat Robert Juliat Robert Juliat Robert Juliat ADB Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-1 -

LIMBURGzaal -03-013 197 198 199 00 01 0 03 04 05 06 07 08 09 10 11 1 13 14 15 16 17 18 19 0 Zijbrug links Horizon-Unit Zijbrug rechts 70 69 68 67 66 65 64 63 84 83 8 81 80 79 78 77 54 55 85 86 87 88 89 90 91 9 93 94 95 96 53 9 30 31 3 33 34 35 36 37 38 39 40 Portaalbrug 41 4 43 44 45 46 47 48 49 50 51 5 56 59 60 61 6 76 75 74 73 15 16 17 18 19 0 1 3 4 5 6 7 8 Zaalbrug beneden 58 1 3 4 5 6 7 8 9 10 11 1 13 14 Zaalbrug boven 57 71 7 Dimmer 3kW PC 1kW PC kw Zoom 1kW (16-36' Zoom kw (15-40') Zoom kw(10-0') Zaallicht 504-51 Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-13 -

Sound: The sound system is optimized for our theatre, as well for tuning as for sound direction. It s not possible to adjust equalization and delay by the user. Sound system, theatre setup Line array Subwoofers Center cluster Fill-inn Front-fill Processing en security Router/delay Meyer Sound M1D Martin Audio WS18X Martin Audio WT3 Martin Audio WT3 Meyer Sound M1D XTA (not accessible) Mediamatrix Nion 6 (6 in/14 out) Sound system, concert setup Line array Martin Audio W8LC Martin Audio W8LCD Subwoofers Martin Audio WLX Center cluster Martin Audio WT3 Fill-inn Martin Audio WT3 Front-fill Martin Audio W0,5 Processing en security XTA (not accessible) Surround system KEFF surround loudspeakers. Controllable in 4 lines (left, left behind, right behind, right). Multicore FOH stage left/right 48/1 Analog and x MADI Coaxial Control room stage right 1/1 Analog 1 extra tie-lines, FOH, Stage, Amplifier room, control room. Isolated earth. Cat6 network for digital connections! Intercom ASL A en B party line connections to stage, control room, FOH, follow spot position and bridges. Clearcom Wireless Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-14 -

Use of radio frequencies RED, Do NOT Use in theatre Heerlen: GREEN, approved to use in Theatre Heerlen 195.000 10.000 Low level audio connections 450.000-470.000 Mobile communication 470.000 494.000 Low level audio connections 494.000 50.000 DVB-T 50.000 518.000 Low level audio connections 518.000 56.000 DVB-T 56.000 550.000 Low level audio connections 550.000 558.000 DVB-T 558.000 574.000 Low level audio connections 574.000 58.000 DVB-T 58.000 608.000 Low level audio connections 608.000 614.000 Radio astronomy, 614.000 791.000 Low level audio connections All frequency s above not for professional use!!! 791.000 81.000 Mobile communication Frequency 801.100 Transmitter Rabozaal Frequency 805.050 Transmitter Limburgzaal Frequency 813.300 Transmitter INGzaal 83.000 83.000 Low level audio connections (Duplex Center Gap) 83.000 960.000 Mobile communication Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-15 -

Video: Camera Fixed (dome) camera to stage. Screens No fixed screens. Coax connections Freely to patch through patch-panel. Connections in FOH, control room, stage en bridges. Technical specifications & equipment list LIMBURGzaal versie: 13-9-015-16 -