Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

Similar documents
Pressure switches for gas and air Pressure sensors

Duplex Filters 40 FLDK 0008(C)-0120(C)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Type 3353 Angle Seat Valve

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

T U R B I N E G A S M E T E R

Pressure Switch for gas and air

Assisted lift operated 2/2-way solenoid valves Type EV250B

PRESSURE REDUCING VALVES

Puddle Flange. FRANK Puddle Flange

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

How To Use A Flowmeter

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

3/2-way Solenoid Valve, direct-acting, NC or NO

Filter Housing SG Standard

CSF16 and CSF16T Stainless Steel Steam Filters

Rittal TopTherm fan-and-filter unit

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

3/2-way Mini Solenoid Valve

Typical Aluminum GFM Mass Flow Meter

Self-operated Temperature Regulators Temperature Regulator Type 1u

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Solenoid valves 2/2-way direct-operated Type EV210A

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

VDL 53 - Vacuum drying oven for flammable solvents

1805 Series Relief Valves

Overflow valve with thread connection

Control- and feedback head for integrated mounting on Robolux valves Type 2036

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Series description: Wilo-Yonos MAXO

MFP14, MFP14S and MFP14SS Automatic Pumps

SITEMA PowerStroke. Technical Information TI-P12. 1 Function. 2 Applications. Mould Closing Devices series FSKP. Contents

4/2-Way Pneumatic Solenoid Valve

Materials : Cast iron body

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

API Flanged Safety Relief Valves Series 526 CATALOG

Pressure regulating valve with modulating kit, type DRV

System 8. ü ( System 8

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

How To Use A Corona Mdi 110

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

ALMATEC Series CX CX 10 CX 130

ETC -SV. Class 0 oil-free compressed air through catalysis

Fluxi 2000/TZ Turbine Gas Meter

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

Series description: Wilo-Yonos MAXO-D

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

Types 66R and 66RR Low-Pressure Relief Valves

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Cable Plug acc. to DIN EN , Form A

EWE Ball Valve-Type Tapping Valve. EWE Ball-Type Tapping Valve. EWE GBM Tapping Valves. for water and gas

Digital inductive conductivity transmitter

Overview of types. Technical data

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Vacuum drying oven for non-flammable solvents

QLM and QLD Series Three-port Control Valves

Threaded Resistance Thermometers Model TR10-D, Miniature Design

VAD Variable Area Desuperheaters

Plastic tube flowmeters Series PT/PS

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Bypass level indicator With magnetic display Model BNA

kymanual or Automatic - it s your Choice

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Cylinders DIN ISO 6431 and VDMA

Battery Powered Digital Mass Flow Meters for Gases

15/40/80CN Series Medium Pressure Filters

Profile rail guides LLR

VAD. Variable Area Desuperheaters

Vacuum Gate Valve DN 100 and DN 150

Automatic Bypass Control AVDO

Pneumatic actuators The Original! Technics of the top class.

Kompressoren. Adsorption Dryer AD

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

RM/55401/M, Roundline cylinder Magnetic piston, double acting

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

SITRANS F flowmeters SITRANS F M

2/2 and 3/2 Way Size 6 Seat Valves

Butterfly Valves PN 6/10/16 for flanged connection

Transcription:

Gas and air filter GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN 125 - DN 200 11.02 Printed in Germany Edition 02.13 Nr. 215 203 1 8 Technical description Filter for interior gas lines as per DIN 3386 with high dust storage capacity. GF/1: Threaded connection as per ISO 7/1. GF/3, GF/4 and GF: Flange connection as per DIN EN 1092-1. Max. flow velocity: 20 m/s. Installation option for pressure measurement point for filter monitoring. pplication Type GF/1, GF/3, GF/4 and GF gas and air filter for protecting downstream fittings. Filter suitable for gases of families 1,2,3 and other neutral gaseous media. pprovals EC type test approval as per EC Gas ppliance Directive: GF.../1 CE-0085 Q0121 GF.../3, GF.../4 CE-0085 Q7127 GF 40125...40200 CE-0085 Q7127 EC type test approval as per EC Pressure Equipment Directive: GF 40125...40200 CE0085 pprovals in other important gas consuming countries.

Specifications - Threaded version Nominal diameter DN 15 DN 20 DN 25 DN 40 DN 50 Rp 1/2 Rp 3/4 Rp 1 Rp 1 1/2 Rp 2 as per ISO 7/1 Max. operating pressure Max. flow velocity GF 5.../1 GF 40.../1 20 m/s bar (50 kpa) bar (400 kpa) mbient temperature Pore width of filter element Measuring/ignition gas connection -15 C to +80 C 50 µm GF 5 /1: G 1/4 screw connection as per DIN ISO 228 upstream and downstream of filter element, on housing cover GF 40 /1: G 1/4 screw plugs as per DIN ISO 228 upstream and downstream of filter element, on housing cover Materials Housing Seals Random laid nonwoven fabric Filter holder aluminium cast NBR PP, PE POM Installation position ny, preferred position: with cap vertical Functional description Filter designed for installation in interior gas lines and compressed air lines to protect downstream fittings. Filter element made of random laid nonwoven polypropylene fabric and metal support frame with pore width of 50 µm. Dust, chips and rust as well as other physical gas-accompanying materials and fouling are retained using the random laid nonwoven fabric. If the dust storage capacity is exceeded or if there is an excessive pressure difference, the filter loses its protective function. Installation Refer to gas flow direction indicated by arrow on filter housing. Provide sufficient space for changing the filter element. If the filter cap is mounted in vertical position, it is easier to clean the filter housing. fter installation, perform leak test. void direct contact between hardening masonry, concrete walls, floors and filter. Change filter element - t least once a year - If pressure difference has increased by 100 % compared to new filter - When pressure difference exceeds 50 mbar Filter monitoring GF 5 /1: The G 1/4 screw plugs can be replaced by suitable screw connections. Connect an gas differential pressure switch to monitor the pressure difference. Gas filter with differential pressure switch G 1/4 screw connection only GF 5 /1 B Differential pressure switch for gas B + 2 8

Dimensions (mm) - Threaded version h Space requirement for changing filter element Type Order No. Max. operating pressure [bar] connection Rp Design Dimensions [mm] a b c d h Weight [kg] GF 505/1 066 191 Rp 1/2 120 90 35 55 125 0.7 GF 507/1 066 209 Rp 3/4 120 90 35 55 125 0.7 GF 510/1 066 217 Rp 1 160 105 54 51 159 1.1 GF 515/1 066 225 RP 1 1/2 160 105 54 51 159 1.1 GF 520/1 066 233 Rp 2 186 140 75 65 215 1.9 GF 4005/1 228 073 Rp 1/2 120 90 35 55 125 0.7 GF 4007/1 228 074 Rp 3/4 120 90 35 55 125 0.7 GF 4010/1 228 075 Rp 1 160 105 54 51 159 1.1 GF 4015/1 228 076 Rp 1 1/2 160 105 54 51 159 1.1 GF 4020/1 228 077 Rp 2 186 140 75 65 215 1.9 = screw connection = screw plug 3 8

Specifications - Flanged version Nominal flange size Max. operating pressure Max. flow velocity mbient temperature Pore width of filter element Measuring gas connection DN 40 DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 Flange connection as per DIN EN 1092-1 bar (400 kpa) 20 m/s -15 C to +80 C 50 µm G1/4 screw plugs as per DIN ISO 228 upstream and downstream of filter element, on left of housing Materials Housing Seals Random laid nonwoven fabric Support frame aluminium cast NBR PP Stainless steel Installation position Functional description Filter designed for installation in interior gas lines and compressed air lines to protect downstream fittings. Filter element made of random laid nonwoven polypropylene fabric and metal support frame with pore width of 50 µm. Dust, chips and rust as well as other physical gas-accompanying materials and fouling are retained by the random laid nonwoven fabric. If the dust storage capacity is exceeded or if there is an excessive pressure difference, the filter loses its protective function. GF.../3, GF.../4 gas filter section ny, preferred position: with cap vertical Installation Refer to gas flow direction indicated by arrow on filter housing. Provide sufficient space for changing the filter element. If the filter cap is mounted in vertical position, it is easier to clean the filter housing. fter installation, perform leak test. Important: void direct contact between hardening masonry, concrete walls, floors and filter. Filter monitor Change filter element - t least once a year - If pressure difference has increased by 100% compared to new filter - When pressure difference exceeds 50 mbar Filter monitoring The G 1/4 screw plugs can be replaced with suitable screw connections. This permits the connection of an gas differential pressure switch to monitor pressure difference. 1 O ring 2 Cover 3 Housing 4 Filter element B Measurement connection Differential pressure switch for gas 1 2 3 4 + B 4 8

Dimensions (mm) - Flanged version h c d b h Space requirement for changing filter element Type Order No. Max. operating pressure [bar] DN connection Dimensions [mm] a b c d h Weight [kg] GF 40040/3 222 637 DN 40 132 195 49 47 96 2.8 GF 40050/4 256 408 DN 50 170 220 76 60 119 4.1 GF 40065/4 256 409 DN 65 194 252 95 93 188 6.0 GF 40080/4 256 410 DN 80 236 300 103 107 206 8.3 GF 40100/4 256 411 DN 100 282 352 119 111 229 12.3 GF 40125 218 162 DN 125 281 360 182 183 365 19.5 GF 40150 218 163 DN 150 281 385 257 259 516 25.5 GF 40200 218 164 DN 200 388 455 236 239 475 40.0 5 8

Volumetric flow/pressure drop characteristic Pressure loss p [mbar] for natural gas (dv = 0,64) Operating flow rate [m 3 /h] Gas flow rate [m 3 /h] (standard flow rate) Pressure loss p [mbar] for air (dv = 1) Inlet pressure p e [bar] 6 8

Diagram 1 - Determining the nominal diameter - Conversion of the flow rate from standard flow rate to operating flow rate. Diagram 2 - Determining the pressure loss ( p). Procedure Determining the filter size 1.1 Define the flow rate as a standard flow rate on the lower scale. 1.2 Draw a parallel reference line along the diagonal dashed line up to the actual inlet pressure. 1.3 You will find region for minimum filter size vertically above this point of intersection. You can read the corresponding flow rate from the scale above. Example Determining the filter size 1.1 Flow rate (standard flow rate) 2,000 m 3 /h 1.2 Inlet pressure 4 bar 1.3 Determining the filter size: min. DN 100, Determining the flow rate: 400 m 3 /h Procedure Determining the pressure loss 2.1 Define the flow rate as a standard flow rate on the lower scale. 2.2 Draw a parallel reference line along the diagonal dashed line up to the actual inlet pressure. 2.3 Go from this point of intersection vertically upwards to diagram 2. The pressure loss for gas and air can be read at the point of intersection with the characteristic curve for the previously determined filter size. The pressure loss for other gases can be estimated from the value valid for air by multiplying this value with the density ratio. Determining the pressure loss 2.1 Flow rate (standard flow rate) 2,000 m 3 /h 2.2 Inlet pressure 4 bar 2.3 Determining the pressure loss for gas: p = 15 mbar Determining the pressure loss for air: p = 23 mbar ll specified values refer to filter mats in new condition. Example Pressure loss p [mbar] for air (dv = 1) 2.3 Pressure loss p [mbar] for natural gas (dv = 0,64) Inlet pressure p e [bar] 1.3 1.2 2.2 1.1/2.1 Operating flow rate [m 3 /h] Gas flow rate [m 3 /h] (standard flow rate) 7 8

Gas and air filter GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN 125 - DN 200 We reserve the right to make any changes in the interest of technical progress. Head Offices and Factory Karl Dungs GmbH & Co. KG Siemensstraße 6-10 D-73660 Urbach, Germany Telephone +49 (0)7181-804-0 Telefax +49 (0)7181-804-166 Postal address Karl Dungs GmbH & Co. KG Postfach 12 29 D-73602 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com 8 8