Through Beam Sensors EK96VB8 Miniature Design Rugged design with full encapsulation Suitable for use as a muting barrier 6000 mm Switching Hysteresis < 15 % max. Ambient Light 10000 Lux Opening Angle 4 Receiver Current Consumption (Ub = 24V) < 40 ma Switching Frequency 500 Hz Response Time 1 ms Temperature Drift < 10 % Temperature -25...60 C Voltage Drop < 2.5 V PNP /Switching Current 100 ma Residual Current < 50 µa Short Circuit Protection Overload Protection Plastic Protection Mode IP 67 M 8x1 Protective Insulation, Rated Voltage 50 V 50 V PNP NO Diagram No. Control Panel No. Suitable Plug No. 102 Plug Version EK96VB8 102 K 1 Power supply "+" Power supply "0V" Power supply (AC Voltage) Switching output (1,2,3...) / NO Switching output (1,2,3...) / NC Contamination / Error output Contamination / Error output Teach input Time delay (activation) RS-232 receive path RS-232 send path Test input Trigger input Analog output (1,2,3,...) for the analog output Block discharge Valve output Valve control output "+" Valve control output "0V" USB data + USB data - Interfaces-Bus A(+)/B(-) Emitted light disengageable Wire colors according to black brown red orange yellow green blue violet grey white pink green yellow These through beam sensors are well suited for use in aggressive industrial environments. The sensor can be checked for correct functioning via the test input. Thanks to their large working range, the devices demonstrate excellent functional reliability in highly contaminated environments. All dimensions in mm (1 mm = 0.03937 Inch) Accessories Mounting Bracket WK Ctrl.Panel K 1 01 05 1 = 2 = Receiver Diode Alignment aid/function indicator 29/06 01 = Switching Status Indicator 05 = Switching Distance Adjuster sensors for your success www.wenglor.com sensors for your success www.wenglor.com
Through Beam Sensors SK96 6000 mm Light Source Red Light Service Life (T = +25 C) 100000 h Opening Angle 5 Emitter Current Consumption (Ub = 24V) < 40 ma Temperature Drift < 10 % Temperature -25...60 C 50 V Diagram No. Control Panel No. Prewired Version SK96 803 K 3 Protection Mode Cabel Length Protective Insulation, Rated Voltage Plastic IP 67 Prewired 2 m 50 V 803 Power supply "+" Power supply "0V" Power supply (AC Voltage) Switching output (1,2,3...) / NO Switching output (1,2,3...) / NC Contamination / Error output Contamination / Error output Teach input Time delay (activation) RS-232 receive path RS-232 send path Test input Trigger input Analog output (1,2,3,...) for the analog output Block discharge Valve output Valve control output "+" Valve control output "0V" USB data + USB data - Interfaces-Bus A(+)/B(-) Emitted light disengageable Wire colors according to black brown red orange yellow green blue violet grey white pink green yellow Miniature Design Rugged design with full encapsulation Suitable for use as a muting barrier These through beam sensors are well suited for use in aggressive industrial environments. The sensor can be checked for correct functioning via the test input. Thanks to their large working range, the devices demonstrate excellent functional reliability in highly contaminated environments. All dimensions in mm (1 mm = 0.03937 Inch) Accessories Mounting Bracket WK Ctrl.Panel K 3 04 1 = 2 = Transmitter Diode no function 29/06 04 = Function Indicator sensors for your success www.wenglor.com sensors for your success www.wenglor.com
Through Beam Sensor YO993 LASER 20000 mm Smallest Recognizable Part 50 µm Light Source Laser (red) Wave Length 655 nm Service Life (T = +25 C) 100000 h Laser Class (EN 60825-1) 2 Beam Divergence ~ 0,5 mrad Emitter Current Consumption (Ub = 24 V) < 20 ma Temperature Drift < 10 % Temperature -10...60 C Protection Class III CuZn, nickel-plated Degree of Protection IP67 M12 1; 4-pin Adjustable Focal Point Diagram No. 703 Suiting Technology No. Suiting Mounting Technology No. 170 Suiting Receiver YO99VB3 YO99VD3 These through beam sensors are well suited for use in aggressive industrial environments. The sensor can be checked for correct functioning via the test input. Thanks to their large working range, the devices demonstrate excellent functional reliability in highly contaminated environments.
All dimensions in mm (1 mm = 0.03937 Inch) 703 + 0 V (AC Voltage) Teach Input Time Delay (activation) Interface Receive Path Interface Send Path Output/Input programmable inverted Trigger Input Analog Output for the Analog Output Block Discharge Valve Output Valve Control Output + Valve Control Output 0 V Ethernet Receive Path Ethernet Send Path Interfaces-Bus A(+)/B( ) Emitted Light disengageable Power over Ethernet Wire Colors according to Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Green Yellow Complementary Products Deflection Mirror LA9 Smallest Recognizable Part Based on the Distance between Emitter and Receiver Ø/mm YO 1,2 1,0 0,8 0,6 0,4 0,2 0,0 0 2 4 6 8 10 12 14 16 18 20 Sr = Switching Distance Ø = Diameter, Smallest Recognizable Part Sr/m Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com
Through Beam Sensor ZD600PCT3 External Teach-In, RS-232 Interface : 60 m Smallest Recognizable Part: 0,05 mm Teach-In 60000 mm Smallest Recognizable Part > 50 µm Switching Hysteresis < 15 % max. Ambient Light 10000 Lux Opening Angle 12 Receiver Current Consumption (Ub = 24 V) < 15 ma Switching Frequency 5 khz Response Time 100 µs On-/Off-Delay (RS-232) 0...5 s Temperature Drift < 10 % Temperature -25...60 C Voltage Drop < 2,5 V / Switching Current 200 ma Short Circuit and Overload Protection Teach Mode NT,MT Protection Class III Adjustment Teach-In Stainless Steel Degree of Protection IP67 M12 1; 4-pin PNP NO/NC switchable RS-232 with Adapterbox Diagram No. 152 Control Panel No. D 7 Suiting Technology No. Suiting Mounting Technology No. 150 160 Suiting Emitter ZD6003 These through beam sensors are well suited for use in aggressive industrial environments. The sensor can be checked for correct functioning via the test input. Thanks to their large working range, the devices demonstrate excellent functional reliability in highly contaminated environments.
1 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 152 + 0 V (AC Voltage) Teach Input Time Delay (activation) Interface Receive Path Interface Send Path Output/Input programmable inverted Trigger Input Analog Output for the Analog Output Block Discharge Valve Output Valve Control Output + Valve Control Output 0 V Ethernet Receive Path Ethernet Send Path Interfaces-Bus A(+)/B( ) Emitted Light disengageable Power over Ethernet Wire Colors according to Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Green Yellow Complementary Products Adapterbox A232 Dust extraction tube STAUBTUBUS-01 Lens LA7 Ctrl.Panel D 7 06 02 01 01 = Switching Status Indicator 02 = Contamination Warning 06 = Teach Button Smallest Recognizable Part Based on the Distance between Emitter and Receiver Ø/mm ZD 600 / ZW 600 1,2 1,0 0,8 0,6 0,4 0,2 0,0 0 10 20 30 40 50 60 Sr = Switching Distance Ø = Diameter, Smallest Recognizable Part Sr/m Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com
Through Beam Sensor ZD6003 Adjustable Focus : 60 m LASER 60000 mm Light Source Laser (red) Wave Length 655 nm Service Life (T = +25 C) 100000 h Laser Class (EN 60825-1) 2 Beam Divergence 0,5 mrad Emitter Current Consumption (Ub = 24 V) < 15 ma Temperature Drift < 10 % Temperature -25...60 C Protection Class III Stainless Steel Degree of Protection IP67 M12 1; 4-pin Diagram No. 703 Suiting Technology No. Suiting Mounting Technology No. 150 160 Suiting Receiver ZD600NCT3 ZD600PCT3 ZD600PCVT3 These through beam sensors are well suited for use in aggressive industrial environments. The sensor can be checked for correct functioning via the test input. Thanks to their large working range, the devices demonstrate excellent functional reliability in highly contaminated environments.
1 = Transmitter Diode All dimensions in mm (1 mm = 0.03937 Inch) 703 + 0 V (AC Voltage) Teach Input Time Delay (activation) Interface Receive Path Interface Send Path Output/Input programmable inverted Trigger Input Analog Output for the Analog Output Block Discharge Valve Output Valve Control Output + Valve Control Output 0 V Ethernet Receive Path Ethernet Send Path Interfaces-Bus A(+)/B( ) Emitted Light disengageable Power over Ethernet Wire Colors according to Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Green Yellow Complementary Products Dust extraction tube STAUBTUBUS-01 Smallest Recognizable Part Based on the Distance between Emitter and Receiver Ø/mm ZD 600 / ZW 600 1,2 1,0 0,8 0,6 0,4 0,2 0,0 0 10 20 30 40 50 60 Sr = Switching Distance Ø = Diameter, Smallest Recognizable Part Sr/m Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com