In the past, we have delivered many different kind of Multi Flash Copper rooms:

Similar documents
Radio Frequency Interference (RFI) Shielding Principles

MRI RF SHIELDING DESIGN

EMI/RFI Shielded Cable Tray

Skirt 1 / 4. The Skirt. The skirt patterns were downloaded from Mark's site but they need expanding before they can be used.

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants

sound reduction systems for commercial, educational and industrial environments

Universal systems for frameless doors

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

For emission and immunity testing according to IEC

Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION


Renovation instructions

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

A Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System

Technical Data Honeycomb Door Leaf

EMC Standards: Standards of good EMC engineering

Physical Security. Paul Troncone CS 996

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

2.9 WINDOW & DOOR BUCKS

A Complete Solution CREATING WALLS THAT DEFINE SPACE

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

VERTICAL DESIGN OPTImAL ACOUSTICS

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

EMI Shielding Tapes Product Selection Guide. Trusted. Performance. from the. Tape Experts

Weekend Antennas No. 1 A Bobtail Curtain for 2m

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Pointers on using the 5GHz WiFi bands

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Building Control Guidance Note

EH-20 20m antenna. By VE3RGW

The replacement or modification of existing windows shall comply with the following requirements:

MRI SHIELDING ARCHITECTURAL SITE PLANNING GUIDE

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

Heavy Glass Frameless Shower Door With Return Panel

DIY CABINET REFACING INSTALLATION GUIDE

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

Bafl-Sorb Sound Absorbing Ceiling Baffles

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

MRI Magnetic resonance radiography utilises pulse shape high-frequency magnetic fields with high amplitude to excite nuclear spin.

EMC Safety switches January 2008

Mass Loaded Vinyl A review of the performance and cost in acoustical applications

Tuning a Monopole Antenna Using a Network Analyzer

Cooktop Low-Profile Ventilation Hoods

The corrugated box: A profile and introduction

SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems

40 Years of experience in EMC testing

Sliding and Folding Door Fittings Sliding Door Accessories

Chapter 2: Foundations

Air Conditioner Duct Construction & Repair

Asbestos Abatement Work Plan for the Carter Carburetor Superfund Site

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

Building Construction. Lightweight construction. Conventional Construction

CHAPTER 6 CONSTRUCTION TYPES

Plaisance 50. Windows and doors. Sapa Building System

Hendricks 41dB Step RF Attenuator

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Avantis 75. Windows & Doors. Sapa Building System

Certification: Building Plans Examiner. Exam ID: B3

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

RFID Receiver Antenna Project for Mhz Band

All content including text and photographs are protected by law - Copyright 2010 by

PANELIZED HOME INSTALLATION GUIDELINE

Turnkey solutions. Design & Consultancy Services

6mm Two Door Offset Quadrant

Installation Instructions and Ordering Information

6.0 Implementation: Retrofitting Gable End Walls with L-Bent Straps

FAQs. 19. Does the sub floor need to be level before I install my new direct-to-stud bathtub or shower base?

Knürr Smaract. Knürr Smaract. CompactRack

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

EMC Expert System for Architecture Design

Networking Cabinets > Part No Capacity Available Colors Height(mm) Width(mm) Depth(mm)

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Attenuation Measurements of Materials Used in Construction of Buildings

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Manual lifting and handling

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

39HQ Airovision Air Handling Units

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

Confort 26. Sliding Systems. Sapa Building System

Flexible Circuit Simple Design Guide

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

BLADE S-MAX Cabinet for Blade Server

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

City of Peterborough

Asbestos Procedures. Asbestos Products

Plaisance 24. Sliding Systems. Sapa Building System

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Lightweight Partition Design for Residential and Commercial Buildings

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Consideration of a high-capacity foil cable:

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Transcription:

We at Metric Industrial A/S have 25 Years experience with building Copper faraday cage, either as glued on to the inner building walls, or make as panel construction, the panel construction is mostly for the MRI application where the required frequency is up to 500 MHz with attenuation up to 80 100 db we offering a turnkey s solution incl. the components below Power & signal filters Waveguides for data communication Shielded doors Windows Shielded ventilation panels Pipes for water, compress air etc. Inner lined wall, ceiling and floor Electrical installation Ventilation system Fire detecting system In the past, we have delivered many different kind of Multi Flash Copper rooms: Inner lined with acoustic panel Test room for the Mobil industries Test room for the semiconductor manufactory Secret room for the intelligent Computer room Antenna chambers And ETC. Wall covering system (Multi Flash-copper) Multi Flash-Copper foils have high attenuation properties in the electrical field (up to 120 db) as well as in the magnetic field (see shielding performance table).

It is easy to apply, like heavy wallpaper, there has to be used special adhesive for walls, ceilings and floors. The interior finish can be plaster board, on a wood framing, glued to the wall The 0.08 mm thick Multi Flash-Copper is used to transform regular rooms into shielded rooms; it has excellent shielding performance even at low frequencies. The standard width of Multi Flash-Copper is 915 mm and the foil is delivered on rolls from 60`long, depending of the thickness, the thickness can be delivered in 3, 5 and 7 oz Overlap options Multi Flash Copper is delivered with clean edge of 15 mm, for easy installation For the joints you can use a 50 mm overlap with seaming copper tape with a conductive self-adhesive to apply over the joints in top picture 1, or use a seaming /copper tape with a conductive self-adhesive to apply over the joints edge / edge picture 3. For extra high performance you can fully solder the joint, what is difficult on walls and ceiling Picture 2 Advantages Cost-effective / take up less space Light weigt / High flor load Can be constructed with local labor, and a trained supervisor Standard interior finish possible like plasterboard Maintenance free Delivery with acceptance measurement report

Shielding performance Basic values for the material and Mu-copper cage Field Frequency Multi-Flash copper H 1 khz 22 db H 10 khz 33 db H 200 khz 68 db E 10 khz >120 db E 200 khz >120 db E 1 MHz >120 db E 18 MHz >120 db P 400 MHz >120 db P 1 GHz >120 db Shielding performance of Multi Flash copper foil 0.08 mm thick Measurements according to MIL STD 285 and the following situation:

Multi Flash copper foil 0.08 mm thick taped with 50mm overlap Dimensions 10 x 6 x 4 m 1 Door 0,9 x 2.1 m 1 sliding door special construction 2.0 x 2.1 m 4 Ventilation panels 1 Power filters You can create a Faraday cage with high shielding performance by yourself in an economic way, using local labor with trained supervisor. This is possible in existing buildings as well as in new ones, without loss space. Depending on the type and quality of the doors and windows used, attenuation levels are from 60 db up to 120 db in the E-field, vent panels, Power / Signal filters have normally attenuation levels of 120 db Ventilation For ventilation we have honeycomb ventilation panels in different size, the pressure drop table are below. Special for the Multi Flash copper faraday cages we can deliver honeycomb vent panels with a base flap around. Can be easily soldered into the Multi Flash copper faraday cage.

For other honeycomb ventilation panels see our honeycomb

Ceiling construction Ceiling construction with beams for, external fixing

Applications Server rooms EMC test rooms Medical examination rooms MRI, EEG, EMG & EVP Radar protection/airport Military EMC protection Board room shielding Buildings for intelligente Agencys MRI rooms Modified RF Shielded Door When a lower performance 40-60 db is acceptable we can retrofit your existing door. The doors will be laminated with Mulit Flash Copper foil, will be equipped with gaskets on top and sides, the bottom is provided with a conductive gasket and doorstep. Modification is possible for both swing and sliding doors. MRI Shielding door

Components In addition to EMI shielded doors and windows, the screened rooms can be equipped with the following components: Shielded doors Shielded windows Shielded ventilation panels Power and signal filters High Performance Shielded door