How To Use An Asbestos Microscope



Similar documents
To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

LABORATORY MICROSCOPEs

MICROSCOPES & REFRACTOMETERS for laboratory, industry and food

Compound microscope (Hund)

Care and Use of the Compound Microscope

SERIE SZR. Stereomicroscopi da laboratorio. 13

PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES

RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

ISO9001 ISO Environmentally-friendly product All optical components in CX41 microscope use lead-free eco-glass.

OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE

Rauserv Steam Sterilizers, Laboratory and Hospital Equipment. Brewery Laboratory Equipment

EXPERIMENT #1: MICROSCOPY

The Kaps SOM -Series. Stereo Examination Microscopes for ENT Specialists. The variable space-saving system for every ENT practice

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

THE COMPOUND MICROSCOPE

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10. Macro View. The first true macro fluorescence imaging system

POLARIZING MICROSCOPE BX51-P BX2 SERIES

Biological Microscope. Biological Microscope ECLIPSE E200

euromex microscopen bv The Netherlands page1/16

MICROSCOPY MARKETING GUIDE

Microscopes 2014 Microscopes PB Microscopes 1

OLYMPUS SYSTEM MICROSCOPE. Model BHT OLYMPUS

OLYMPUS STUDENT MICROSCOPES IINSTRUCTION MANUAL I CBA& CBB MODELS

Measuring. User Manual

Exercise 2. The Compound Light Microscope

HISTOLOGY LABORATORY. Microscope Orientation and Blood Smear Lab

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Olympus BX51 Microscope & DP70 Digital Camera System

Leica DM LS2 and DM LB2. Life Science System Microscopes with New Ergonomic Concept

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

MEASURING QUALITY. SINCE 1796 MICROSCOPES. RELIABLE SOLUTIONS FOR ANY APPLICATION

Review: Amscope Metallurgical Trinocular Microscope. Michael Reese Much FRMS EMS Bethlehem, Pennsylvania USA

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Swift Optical Catalog. Microscope and Digital Microscopy Solutions

Leica DM500 & DM750. A New Generation s Choice of Innovative Educational Microscopes

Firearms & Tool Marks Comparison Microscope. Discovery. Leeds Forensic Systems. Your Forensic Imaging Source

IMPORTANT. 2. Avoid the use of the microscope in direct sunlight, high temperature and humidity, dust and vibration.

Product Range Overview

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Leica MZ125. Modular high-performance stereomicroscope with 12.5:1 zoom

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

GLobAL Dental Microscopes. Dentists First Choice

The upright transmitted microscope is most suited to our purpose of observing samples of compost, soil and compost tea, etc.

Microscope Lab Introduction to the Microscope Lab Activity

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

VICKERS HARDNESS TESTER. HBS HBW Kc

Inspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.

MICROSCOPE & OPTICAL CATALOG

Forensic Science: The Basics. Microscopy

The British Occupational Hygiene Society Faculty of Occupational Hygiene INTERNATIONAL MODULE SYLLABUS W504 ASBESTOS AND OTHER FIBRES

microscope OP-Dent-5

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

Inverted Microscope. Inverted Microscope ECLIPSE TS100

Light and its effects

The new standard in research microscopy

MODULE 2B INDUSTRIAL HYGIENE LABORATORY ACCREDITATION PROGRAM (IHLAP) ADDITIONAL REQUIREMENTS

Microscopy and Cellular Morphology

TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.

Chapter 12 Filters for FISH Imaging

OLYMPUS STUDENT MICROSCOPES INSTRUCTIONS ST. HS&HSC MODELS OLYMPUS

Lenses and Apertures of A TEM

Measuring the Point Spread Function of a Fluorescence Microscope

Animal & Plant Cell Slides

14 The ability of the lenses to distinguish fine detail and structure is called a. Illumination b. Magnification c. Refractive index d.

Infrared Viewers. Manual

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

Use of the Microscope and Cytology

Nightspot High performance floodlights for discharge lamps and LEDs

NOT SEARCHING, BUT FINDING

OLYMPUS SYSTEM MICROSCOPE FOR METALLURGICAL USE

INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT

Quick Start Guide. Digital Inverted Microscope. The Microscope Evolved.

A concise guide to Safety Glasses, the different standards and the effects of light on the eye. Contents. Links. Year of publication: 2010

9.7" Microscope Tablet Camera (REALPAD 5.5) Introduction. Feature

HEINE 3S LED HeadLight

Microscopes and the Metric System

The illustrations below reflect other scientists results in identifying and counting the stages of the onion root tip and the whitefish blastula.

<788> PARTICULATE MATTER IN INJECTIONS

Design collection. 12 Volt Outdoor Lighting

How To Use A Ds340 (Dsp)

LOUPES AND HEADLIGHTS HEADLIGHTS. HEINE Headlights. Type of Light LED LED F.O. Light Intensity (at 250 mm working distance)

NAME THE POLARIZING LIGHT MICROSCOPE AND FORENSIC SCIENCE. I. Introduction

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)

Protocol for Microscope Calibration

Operating Manual. Axiostar plus. Transmitted-Light Microscope

MIRAX SCAN The new way of looking at pathology

C) D) As object AB is moved from its present position toward the left, the size of the image produced A) decreases B) increases C) remains the same

Transcription:

Asbestos Microscopes and Accessories Pyser-SGI has been supplying microscopes and accessories into Asbestos Laboratories for over 40 years PS12 Stage Micrometer with UKAS Certificate of Calibration - For calibrating microscope and eyepiece graticule Walton and Beckett Eyepiece Graticules 3 versions For counting and sizing of fibres. HSE/NPL Phase Contrast Test Slide with Certificate For checking the resolution of the phase contrast microscope. Phase Contrast Microscope For analysis/counting of fibres Polarisation Microscope For identifying fibre types Stereo Microscopes For initial examination of materials PS12 Stage Calibration Standard The PS12 stage calibration standard has a 0.1mm length scale in 50 x 2-micron divisions. The scale is centred on a glass disc, mounted in a stainless steel slide 75mm x 24mm x 2mm thick. A unique serial number is engraved into the stainless steel slide mount. Each slide is supplied in a polished wooden presentation/storage box to distinguish it as a traceable standard of high value. For most asbestos laboratories there is a need for traceability of calibration, therefore Pyser recommend that the PS12 is supplied with a UKAS certificate of calibration. This calibration is traceable back through the National Physical Laboratory (The UK s National Metrology Institute) and then onto the International Committee of Weights and Measures (CIPM), so is universally accepted around the world. Being 0.1mm long, this scale is ideally suited for calibration of any microscope being used for asbestos analysis with a Walton & Beckett graticule. 2

Walton and Beckett Eyepiece Graticules When counting asbestos samples, it has been found that limiting the area of evaluation to that defined by the grid on an eyepiece graticule can give significantly higher operator concentration values than when the full field of view of the microscope is used. The published work by S T Beckett et al in 1976 recommended that the graticule grid method of counting be adopted for asbestos analysis and that steps be taken to reach national or, preferably, international agreement on a standard form of graticule. The Walton and Beckett graticule was designed specifically for the evaluation of fibrous dust and was adopted worldwide. The Walton and Beckett graticules are used for counting fibrous dust and are particularly useful where the majority of fibres to be counted are shorter than 5 microns. The circle is divided into four by two diametrical lines scaled in units of 5 and 3 microns. 3 and 5 microns are the critical measurements of fibre lengths and diameter used in fibre counting. Unlike the usual globes of other particle graticules the Walton and Beckett has a series of shapes to compare objects with. These shapes have been designed for comparison with fibres, especially since they incorporate aspect ratios of 3:1 (G22) or 5:1 (G24) essential for such analysis. Based on the G22, the G25 is produced to a new design by the Institute of Occupational Health in 1996. G22 G24 G25 Calibration Factors for Walton and Beckett Graticules. The circle on the Walton and Beckett graticule must represent 100 microns at the stage of the microscope when used with a 40x objective lens. The microscope needs to be calibrated to ensure that the Walton and Beckett graticule will give true measurements when it is fitted see example below. defined as 4. Our standard Walton and Beckett graticules are made with a calibration factor of 4, however it is important to check the exact calibration as microscopes do vary. We can make these graticules with calibration factors to suit the actual calibration of your microscope. When placing your order please state the diameter of the graticule required and, if a special calibration is required, provide the calibration To calibrate your instrument, fit the microscope with an eyepiece scale (for example, our part NE1) and the appropriate stage micrometer (see the article on our part PS12 on facing page). An exact calibration factor can then be calculated. For example, using a 40x objective, a circle in the eyepiece requires a diameter of 4000 microns (4mm) to coincide with or read a 100-micron circle on the stage. The calibration is therefore 3

S84 HSE/NPL MKIII Test Slide for Calibration in Asbestos Analysis The S84 test slide is made in the UK under licence from the National Physical Laboratories and is used to verify the resolution of phase contrast microscopes used for the analysis of asbestos fibres. It is an epoxy replica of a master slide produced and certified by that laboratory. The replicas are mounted on microscope slides of 1.2mm thickness with cover glass of 0.17mm thickness. The slide is recommended by the Asbestos International Association in their publication, Recommended Technical Method No. 1, and many other publications around the world. The use of the HSE/NPL slide is also required in the method adopted by the Health and Safety Commission to determine compliance with UK asbestos control limits. It has been adopted worldwide as the standard for testing phase contrast microscopes. The slide comprises 7 bands, with 20 lines in each, and the width of the lines decreases in each band. These lines will show up under phase contrast microscopy. The microscope used for asbestos counting and analysis must be capable of viewing band 5 and partially viewing band 6. 4

Phase Contrast Compound Microscope This is probably the most important of the microscopes as it is the instrument that allows the size and concentration of asbestos fibres to be analysed. The most widely used method of measuring airborne asbestos is to collect the fibres on a membrane filter and then count them by phase contrast microscopy. The counting procedure is detailed in numerous documents around the world with the original description in a publication by the Asbestos Research Council (A.R.C. 1971) and in the B.O.H.S. (1968) standard. The Pyser B-500pl is probably the most comprehensive and cost effective solution to your phase contrast requirements. It is fitted with both infinity corrected brightfield and phase contrast objectives and supplied with standard and Walton and Beckett eyepieces making it suitable not only for the analysis of asbestos, but also for other examinations in the laboratory. The B-500pl satisfies the requirements of HSE for identifying band 5 on the test slide. The Pyser B-500pl Specifications: B-500pl Body: Die cast aluminium Head: Binocular or Trinocular with 30º inclined eyepieces, 360º rotating Eyepieces: Paired WF10x/22mm with high-point view. Paired WF12.5x with Walton & Beckett graticule Objectives: Infinity corrected Plan Achromatic 4x, 10x, 40x, 100x (oil), Phase contrast PH40X with phase ring, Quintuple reversed nosepiece Stage: Focussing: Condenser: Illumination: Dual layer mechanical stage, 175x145 mm with low level controls Coaxial coarse and fine focusing system with focusing stop mechanism Abbe N.A. 1.25 with centring system, phase ring and green filter High efficiency system with halogen 20W dichroic lamp, adjustable with Köhler illumination 5

Polarising Microscope This microscope allows the identification of individual fibre types using polarisation of light to give distinct colours. The McCrone dispersion staining objective, which enhances the colours and allows better identification of the fibres is sometimes fitted to this microscope. The Pyser B-600 polarising microscope is a research standard instrument with advanced features to enhance the image quality. Specifications: B-600 Body: Die cast aluminium Head: Trinocular, 30 inclined, 360 rotating with adjustable interpupillary distance Eyepieces: Paired WF10X/22mm with diopter adjustment Bertrand lens: Swing-out type, centrable, 360 rotating. Polarising attachment: Blue filter, 0-90 rotating analysing filter, λ slip (first class red), 1/4 λ slip, quartz wedge Objectives: Plan IOS POL (strain-free) 4x/0.10, 10x/0.25, 40x/0.65, 60x/0.85 on reversed quadruple nosepiece with centring mechanism for all objectives Focusing system: Coaxial coarse and fine Stage: 160mm diameter, 360 rotating with stop knob and 0.1 vernier Condenser: Abbe 1.2 N.A., with iris diaphragm, focusable and centrable, with rotating polarising filter (swing-out type). Illumination: 12V/50W halogen bulb in external case. Centrable bulb and brightness control. The Pyser B-600 6

Stereo Microscopes XES-70C-2L For the initial examination of asbestos fibre samples a stereo microscope is recommended. This microscope has two separate optical paths and so views an image with perspective, making it ideal for looking at 3D specimens. The simplest design is the Pyser XES-70C-2L stereo microscope with 20x and 40x magnification, selectable by rotating the objective turret. With the benefit of dual lighting, this microscope also has single control focussing and is simple to operate. Specifications: XES-70C-2L Body: Head: Eyepiece: Objective: Stage/Stand: Focussing: Illumination: Die cast aluminium 45º inclined binocular head with adjustable interpupillary distance from 55mm to75mm Paired W10x with ±5 diopter adjustment on one eyepiece Rotating turret with 2x and 4x objectives Removable and interchangeable white/black and frosted glass plate 94.5mm diameter with spring clips Rack and pinion Incident and transmitted halogen lamps, independently switchable If you need a more advanced microscope with zoom magnification then Pyser offers the XES-80T-2L. This microscope has a trinocular head to allow cameras to be connected often useful when preparing reports. The zoom control allows users to increase or decrease the magnification so that the specimen can be viewed in detail. XES-80T-2L Specifications: XES-80T-2L Body: Head: Eyepiece: Objective: Stage/Stand: Focussing: Illumination: Die cast aluminium 45º trinocular head with adjustable interpupillary distance from 55mm to 75mm. C-mount camera adaptor included Paired W10x with ±5 diopter adjustment on one eyepiece Zoom range 1:4 (7.5x to 35x as standard) Auxiliary objectives available to expand magnification range. Removable and interchangeable white/black and frosted glass plate 94.5mm diameter with spring clips Rack and pinion Incident and transmitted halogen lamps, independently switchable 7

Item Ref. Description Diameter/Head Order Code Type PS12 Micrometer Scale 0.1mm in 0.002mm divisions 05A01043 PS12 with UKAS certificate 05A01043/NAM PS12 with NPL Certificate 05A01043/NPL G22 G24 G25 Walton/Beckett for Asbestos 3-1 Ratio. All with calibration factor of 4. 16mm 01A16062 19mm 01A19062 21mm 01A21062 23mm 01A23062 24mm 01A24062 26mm 01A26062 27mm 01A27062 Other diameters and/or other calibration factors Others Walton/Beckett For Asbestos 5-1 Ratio. All with calibration factor of 4. 16mm 01A16063 19mm 01A19063 21mm 01A21063 23mm 01A23063 24mm 01A24063 26mm 01A26063 27mm 01A27063 Other diameters and/or calibration factors Others Walton/Beckett (1996). All with calibration factor of 4. 16mm 01A16085 19mm 01A19085 21mm 01A21085 23mm 01A23085 24mm 01A24085 26mm 01A26085 27mm 01A27085 Other diameters and/or calibration factors Others S 84 HSE/NPL Test Slide for Phase Contrast Calibration in Asbestos Analysis HSE recommend that the S84 is re-tested every 3 years 02F00490 B-500pl Pyser B-500pl Phase Contrast Compound Microscope Binocular 780-510 Trinocular 780-511 B-600pol Pyser B-600pol Polarising Microscope Trinocular 780-620 XES-70 Pyser XES-70C-2L Stereo Microscope with 2x/4x objectives. Also available with 1x/3x objectives Binocular 730-308 XES-80T Pyser XES-80T-2L Stereo Zoom Microscope Trinocular 735-143 8 PYSER - SGI LIMITED Fircroft Way, Edenbridge, Kent, United Kingdom, TN8 6HA Telephone: +44 (0)1732 864111 Facsimilie: +44 (0)1732 865544 Email:sales@pyser-sgi.com www.pyser-sgi.com May2011 E & OE