OLYMPUS SYSTEM MICROSCOPE FOR METALLURGICAL USE
|
|
|
- Egbert Griffith
- 9 years ago
- Views:
Transcription
1 OLYMPUS SYSTEM MICROSCOPE FOR METALLURGICAL USE scanned by J. G. McHone 6Novl I,= for personal use only, not for sale INSTRUCTION MANUAL MODEL I." a 'C. A
2 CONTENTS STANDARD EQUIPMENT VARIOUS COMPONENTS OF THE MODEL BHM ,... 3 ASSEMBLY IDENTIFICATION AND FUNCTION OF VARIOUS COMPONENTS OPTICAL SYSTEM Objectives 2. Eyepieces Vertical Illuminator A. Aperture iris diaphragm B. Field iris diaphragm LIGHT SOURCE STAGES Removal of Specimen Holder 2. Stage Spacer 3. Metal Slides Vlll. OBSERVATION TUBE lnterpupillary Distance and Diopter Adjustments 2. Light Path Selection IX. FOCUSING ADJUSTMENT Tension Adjustment of Coarse Adjustment Knobs 2. Automatic Pre-focusing Lever 3. Stage Height Locking Lever TROUBLESHOOTING
3 C I. STANDARD EQUIPMENT Component BHM Microscope stand with base BHM-F-2 Revolving nosepiece BH-R E o o o o Observation tubes Binocular tube, incl~ned 3' BH-B 13 Trinocular tube, inclined 3, w~th vertical photo tube BH-TR3 O O Vertical illuminator for brightfield 15-watt tungsten lamp house BH-MA BH-LHM Tungsten bulb, 6V 15W, 3 pcs. LS15 Square mechanical stage with right-hand low drive controls BH-SV Transformer TE-l I M5X, MIOX, MZOX, M4X (set of four) Ob~ectlves M Plan 5X, M Plan lox, M Plan 2X, M Plan 4X, M Plan 1X (oil) (set of five) Eyepieces High eyepoint BiWF lox, paired Photo eyepiece F K3.3X Metal slide plates (set of f~ve) l rnrnersion oil, bottled o Eyepiece caps (2 pcs.) Filter 32.5C Vinyl dust cover
4 II. VARIOUS COMPONENTS OF THE MODEL BHM The Oiympus System Microscope for reflected light Model BHM consists of a modular, building-block system of various components and interchangeable accessories, as shown below. A wide variety of combinations, standard or optional, is available according to your requirements. d Eyepiece Observation tube /C watt tungsten Vertical illuminator -- Objective -- Stage Cord adapter
5 a Ill. ASSEMBLY The picture below illustrates the sequential procedure of assembly. The numbers indicate the order of assembly of various components. Remove dust caps before mounting components. Take care to keep all glass surfaces clean, and avoid scratching the glass surfaces. O Eyepiece caps a Observation tube 8 Tungsten bc~ tb % This unit should be attached on the microscope stand with the lamp house pointing away from the observer.
6 IV. IDENTI FlCATlON AND FUNCTION OF VARIOUS COMPONENTS Mechanical tube length adjustment rings Larnp house Rotate the rings to match the interpupillary distance setting obta~ned from the scale, and to correct individual diopter adjustments. \ control knobs
7 lnterpupillary distance scale Low voltage ment knob Pilot lamp Voltmeter Main switch Analy~erotation / / / / Aperture iris Field iris diaphragm High/low magnification selector lever Position "L" for objective 5X and position "H" for objectives 1X and higher. Filter mount Polarizer mount
8 Summary of Putting the Microscope in Operation Model BHM Place a specimen on the mechanical stage (see page 13). Adjust the stage height (see page 151. Switch on the transformer. Swing the 1X objective into the light path and coarse focus. Make interpupillary and diopter adjustments (see page 14). Swing in the desired objective. Fine focus. Correct the illumination system. Adjust light intensiw. Adjust aperture iris diaphragm and field iris diaphragm (see page 121. Cut off this page at the dotted line and put it on the wall near the microscope as a reminder of correct microscope operation.
9 Q V. OPTICAL SYSTEM The optical system of the Series BH is divided into five sections: Objectives, Observation Tubes, Eyepieces, Illuminating System and Photomicrographic Equipment, The following section deals with objectives, eyepieces and illuminating system. 1. Objectives A. Types Two types of Olympus objectives are mentioned below, in accordance with their optical performance and corrections of various aberrations. Achromats: Corrected for chromatic aberration, and most popular for general use. Plan achromats: Capable of producing a flat image to the edge of the field. Recommended for visual observation of a large field and photomicrography of flat objects. B. How to Use Immersion objectives (engrave "HI" for homogeneous immersion): To utilize the full numerical aperture of an immersion objective, the objective and specimen are immersed in an Olympus immersion oil, provided. Care should be taken to prevent oil bubbles from forming in the oil film between specimen and objective. After use, carefully wipe off the immersion oil deposited on the top lens surface of the objective with gauze moistened with xylene. Take care not to immerse objectives other than immersion objectives. Special objectives: Long working distance objectives: Provide a longer working distance than standard objectives of equal power. Differential interference contrast objectives: These strain-free objectives of high N.A. can be used not only for the differential interference contrast method, but also for brightfield.
10 2. Eyepieces The eyepieces available with the Series BH are computed to correct slight residual errors left uncorrected in the objectives and designed to further magnify the primary image from the objective, limiting the field as viewed by the eye. Widefield eyepiece (WF): Color corrected and flat, w~de field; high eyepoint, convenient for observers wearing eyeglasses. Compensating eyepiece (K): Corrected for chromatic aberration and astigmatism. For use with high power objectives. Photo eyepiece {FK): For photomicrographic use. Fully corrected for field flatness in combination with all Olympus objectives. * The eyepieces mentioned above can be used with drop-in eyepiece micrometer discs. Q Use of eyepiece cap (for standard eyepiece) The eyepiece cap is recommended for those who wear eyeglasses. It prevents damage to the eyeglasses. Q Use of eyepiece with eye shield The eyepiece WFlOX incorporates a sliding eye shield. This eye shield can be polled out to prevent glare and loss of contrast caused by ambient light hitting the eyepiece front lens.
11 *** BiK5X and BiWF15X are optionally available. * The resolving power is obtained when the objective is used with fully opened aperture diaphragm. ce from the specimen or cover glass to the nearest point of the objective. A longer working distance is covenient to ge to the objective front lens or specimen, or when using a thicker cover glass. abbreviated N.A. A mathematical relationship that directly connects the resolving power and the light-gathering power of e with its aperture. N.A. is the product of the sine of half the angular aperture of a lens, and the refractive index of the rough which the light passes. It is a very important constant for high power lenses. The N.A. values can be used for mparing the resolving power of all types of objectives, dry, water or oil immersion. of a lens to register small details. Resolving power is of vital importance in critical microscopy. The resolving power is measured by its ability to separate two points (line structure in the object may be considered as a row of points). ing power is now placed at R=K Wavey K=cons tant wavelength of the light employed is 4mp to 7m p. Decreasing the wavelength of the light employed increases ng power. The higher the resolving power of an objective, the closer the image will be to the true structure of the object. ce in micron between the upper and lower limits of sharpness in the image formed by an optical system is termed "focal uctures outside these limits are more or less blurred and with low power objectives are apt to interfere with the image in smaller the aperture iris diaphragm setting and the lower the N.A., the larger the focal depth. Lack of focal depth is rent in photomicrography, particularly with low power objectives, as the image is projected on the film in one place. that represents the diameter in mm of the image of the field diaphragm that is formed by the lens in front of it. size of the field of view in mm. Tllis is derived from Field number of eyepiece.'
12 3, Vertical Illuminator The reflected illumination system adopted in the Model BHM is based on the Koehler principle, with features as Aperture iris diaphragm and field iris diaphragm operate The light source illuminates the full numerical aperture of the The entire field of view can be evenly The illuminator is provided with a high/low magnification selector lever to exactly match illumination with objective magnification in Optimum light intensity can be easily obtained.
13 A. Aperture lris Diaphragm In order to achieve optimum objective performance, the opening of the aperture iris diaphragm should be matched to the numerical aperture of the objective in use. It is often preferable, however, to stop down the aperture diaphragm slightly more than indicated by the objective N.A. This will result in better image contrast, increased depth of focus and a flatter field. After completing focus adjustment, remove one of the eyepieces from the observation tube and look into the empty eyepiece tube. As you stop down the aperture iris diaphragm, the image of the iris diaphragm can be seen in the objective pupil. Adjust the opening of the diaphragm to match the N.A. of the objective in use. If the specimen is low in contrast, it IS recommended to stop down to 7-8% of the objective N.A. Opening of the diaphragm Objective pupil,--+$\ 8. Field lris Diaphragm The field iris diaphragm controls the diameter of the ray bundle impinging on the specimen surface and thus increases image definition and reduces glare. For microscopic observation, it is necessary to stop down the field iris diaphragm until the diaphragm is just outside the field of view as you look through the eyepiece. For photomicrography, the field iris diaphragm must be stopped down in accordance with the field as viewed through the field of view eyepiece, focusing telescope, etc, in use. VI. LIGHT SOLIRCE The standard light source incorporates a 15W pre-centered tungsten filament bulb (LS15), combined with a socket for positive contact, eliminating the problems of defective contact and over-heating. * When used at the rated voltage 6V, the average life of the tungsten bulb LS15 is longer than 2 hours. This is, however, greatly reduced, if the bulb is used at higher voltage; for instance, the bulb life is reduced to 1/5 at 8V. Therefore, it is advisable to avoid prolonged use at readings over 6V (in the red zone). If high intensity illumination is required, ~t is recommended to use the optional hidh intensity halogen illuminator, * Do not switch the tungsten bulb on at high intensity. It reduces bulb life.
14 VII. STAGES 1. Removal of Specimen Holder 1) Square mechanical stage with right-hand low drive controls Model BH-SV The standard mechanical stage is provided with a springloaded specimen holder, which is capable of holding specimens up to 55rrtm x 85mm in size. The specimen holder is removable to obtain a large unobstrticted stage surface, (Fig. 1) 2) Large mechanical stage Model BH-SIC This 2Omm x 161 mm square mechanical stage has a traversing area of 11 Omm x 1mm, by rneans of coaxial low drive controls. It is possible to adjust the distance between the holders according to specimen sizes, For exceptionally large specimens, the holders cart be removed. For use with IC wafers, masks or other special specimens, custonier designed specimen holders can be utiliied. I Fig. 1 I 2. Stage Spacer In order to prevent interference between objectives and specimen holder it is recommended to use the stage spacer provided w~tti the stage Model BH-SV and place it in the manner shown in Fig. 3, prior to placing a thin specimen on the stage. (Fig. 3) 3. Metal Slides To level a specimen: 1) Put plasticine on a metal slide supplied. 2i Place a specimen on the plasticine, and press the specimen with a hand press until the specimen surface is Fiq. 3 properly leveled. * It is suggested to place a piece of tissue paper between the specimen and the plunger of the hand press in order to prevent scratching of the polished specimen surface. (Fig. 4) Fig. 4
15 , OBSERVATION TUBE lnterpupillary Distance and Diopter Adjustments 1) Hold the knurled dovetail of the right and left eyepiece tubes with both hands and push the tubes together, or pull them apart laterally, whichever is required, while looking through the eyepieces with both eyes, until perfect binccular vision is obtained. 2) Memorize your interpupillary distance setting. is provided for this purpose. Fig. 5 3) Rotate the tube length adjustment on the right eyepiece tube to match your interpupillary distance setting which you obtained from the scale. (Fig. 5) 4) Look at the image through the right eyepiece with your right eye and focus on the specimen with the fine adjustment knobs. 5) Next, look at the image through the left eyepiece with your left eye and rotate the tube length adjustment to focus on the specimen without using the coarse and fine adjustment knobs. * The mechanical tube length of the Olympus metallurgical microscope is standardized at 2mm. 2. Light Path Selection The trinocular observation tube is provided with a light path selector lever to direct the light to the observation tube or to the photo tube, Lever position Pushed in all the way Pulled out all the way Amount of light 1% into binocular tube 2% into binocular tube 8% into photo tube Application (1) Normal observation 12) Dark specimens (1 Photomicrography (2) Observation of excessively bright specimens - * In case of long time exposure, it is necessary to darken the room or put a pair of light shield caps, provided with the trinocular tube, on the eyepiece tubes, in order to prevent light from coming on the film plane.
16 FOCUSING ADJUSTMENT Tension Adjustment of Coarse Adjustment Knobs A tension adjustment is provided next to the right hand coarse adjustment knob. With this device the tension of the coarse adji~stment is freely adjustable for either heavy or light movement, depending on operator preference. (Fig. 6) However, do not loosen the tension adjustment ring too much, because the stage drops or the fine adjustment knobs slip easily. 'k Be careful not to rotate the right and left coarse adjustment knobs in the opposite direct~on simultaneously. (Fig. 6i Fig Automatic Pre-focusing Lever This is provided to prevent possible contact between specimen and objective as well as to simplify coarse focusing. The lever is locked after coarse focus has been accomplished. This prevents further upward travel of the stage by means of the coarse adjustment knobs, and automatically provides a limit~ng stop if the stage is lowered and then raised again. The automatic pre-foctising lever does not restrict fine focusing. (Fig. 7) Fig Stage Height Locking Lever In addition to the vertical movement of the stage by means of coarse and fine adjustments, the stage height position can be changed by means of the stage height locking Maximum specimen height is 55rnm with the standard objectives, and 37mm with the differential interference contrast attachment. (Fig. 8)
17 X. TROUBLESHOOTING Troubles 1. Optical System Causes Remedies (a] With the illuminator switched on, the field of view cannot be seen. (b)the field of view is cut off or illuminated irregularly. The field iris diaphragm is not opened sufficiently. The light path selector lever is stopped midway. The nosepiece is not clicked into position. The field iris diaphragm is stopped down excessive1 y. The bulb or lamp house is not correctly positioned. Open the field diaphragm fully. Push the lever all the way. Slightly rotate the nosepiece until it clicks into position. Open the diaphragm sufficiently Insert the bulb or lamp house all the way. The highilow magnification selector lever of the illuminator is not correctly positioned. I (c) Dust or dirt is visible in / Dust or dirt on the bulb end. 1 I I the f ied of view. Dust on half mirror. 1 Dirty specimen. Dust on eyepiece. I / prism in the observation tube. I (d)excessive image contrast. Dust on the lower surface of the ped down excessively. Position the lever correctly.. Clean off the dust or dirt. Open the diaphragm. (e) Resolution problems: I ) Image is not sharp. 2) Insufficient contrast. The highilow magnification selector lever is not correctly positioned. The bulb or lamp house is not correctly positioned. The objective is not correctly positioned in the light path. Dirt on objective front lens. The immersion objective is used without immersion oil. Bubbles in the immersion oil. The Olyinpus specified oil is not used. The specimen is not properly illuminated. Place the lever in correct position. Push the bulb or lamp house ail the way home. Slightly rotate the nosepiece until it clicks into position. Clean the objective. Apply immersion oil. Remove bubbles, Use the specified oil Adjust the illumination.
18 - - Troubles Causes Remedies (f) The field of view IS The ob~ectlve IS not correctly poslpart~ally out of focus. tioned ~n the lrght path ~t clicks lnto positlon I The Image is partly out of focus. Slightly rotate the nosepiece unt~l =-not correctly pos- I Place the specmen on the stage and tioned on the stage. I secure it with the specimen holder. G i m e n surface 1s not at rrght Level the specimen surface cor- I angles w~th the opt~cal axis. rectly wrth a hand press. l- The high/low magnification selector Turn the lever all the way until ~t lever 1s not properly operated (or stops in position. I the lever 1s pos~tioned mrdway) (gf When objectives are changed, they are not parfocal. 2. Electric System (a)the light flickers and ' the intensity is varying. Mechanical tube length adjustment 1 rings on observat~on tube are not correctly adjusted. The filament of the bulb is likely to burn out. Adjust the rings correctly. Loose electrical connection. Secure the connection. (b)the pilot lamp lights / The bulb is burned out. I Replace the bulb. I but the illuminator I does not. k ~ r i cconnect~on. a Secure the connection. I {c) Reduced bulf I~fe. Ma~ns voltage is too hlgh. Use the tungsten bulb under 6V as well as possible, or use a high intensity light source, such as a halogen illuminator. 3. Focusing I (a) Coarse adjustment - is 1 ension adjustment ring is tighten- the adjustment ring protoo tight. ed too much. The user is trying to raise the stage passing over the upper focusing lrmit imposed by the engaged prefocus~ng lever. 1 Unlock the pre-focusing lever. iblthe stage drops and the specimen goes out of focus. The tension adjustment ring is too loose. Tighten the ring properly. (c)the stage cannot be raised to the upper limit of the working range. The pre-focusing lever is engaged in positioning the stage lower than the focusing position The stage height locking lever is engaged in a position lower than the focusing range. Unlock the pre-focusing lever. Unlock the lever, and raise the stage to the proper height, then lock the lever.
19 Troubles Causes Remedies (d)the stage cannot be lowered to the lower limit Observation Tube I (a) Incomplete vision. binocular The stage is locked higher than focusing position. lnterpupillary distance is not correctly adjusted. Loosening the stage height locking lever, lower the stage to a proper height, and then lock the lever. Correct the interpupillary distance. Diopter adjustment is incomplete. Right and left eyepieces are not matched. The user is unaccustomed with a binocular vision. Complete the diopter adjustment. Use a pair of matched eyepieces. Prior to looking at the binocular image of the specimen, try to look the entire field of view, or look at a far away object before resuming microscopic observation Stage (a)the Image moves eas~ly when you touch the stage. The stage IS not correctly clamped. The stage height locking lever is not tightened. Clamp the stage securely. Tighten the lever securely.
20 OWlsPCWOFnCALCm..)1D. 43-2, HATAGAYA?&HOME, SHIBUYA-MU TOKYO, JAPAN I
OLYMPUS STUDENT MICROSCOPES IINSTRUCTION MANUAL I CBA& CBB MODELS
OLYMPUS STUDENT MICROSCOPES IINSTRUCTION MANUAL I MODELS CBA& CBB Scanned by J. G. McHone. 8 Nov 09 for personal use only. not for sale This instruction manual has been prepared for the Olympus Student
MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL
Introduction With your purchase of an MT-30/MT-90 series type microscope you have chosen for a quality product. The MT-30/MT-90 series type microscopes are developed for use at schools and laboratories.
Care and Use of the Compound Microscope
Revised Fall 2011 Care and Use of the Compound Microscope Objectives After completing this lab students should be able to 1. properly clean and carry a compound and dissecting microscope. 2. focus a specimen
MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.
MICROSCOPY I. OBJECTIVES To demonstrate skill in the proper utilization of a light microscope. To demonstrate skill in the use of ocular and stage micrometers for measurements of cell size. To recognize
OLYMPUS SYSTEM MICROSCOPE. Model BHT OLYMPUS
OLYMPUS SYSTEM MICROSCOPE Model BHT OLYMPUS This instruction manual has been written for the use of the Olympus System Microscope Model BHT. It is recommended that you read the manual carefully in order
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS 156, 156-S, 157 COMPOUND BIOLOGICAL MICROSCOPES
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS 106, 106-L 107, 107-L 108, 108-L 109-L ELEMENTARY
OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE
OPERATING INSTRUCTIONS XJL 0/0A REFLECTED LIGHT METALLURGICAL MICROSCOPE M.R.C.LTD. OFFICES: HAHYSTADRUT 84, HOLON 58394 P.O.B. 684, TEL-AVIV 606, ISRAEL TEL: 97-3-559305,97-3-55955 FAX: 97-3-559459 www.mrclab.com
Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012
Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012 Figure 1.1 illustrates the parts of an upright compound microscope and indicates the terminology that I use in these notes. Figure 1.1. Parts of a Compound
Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure
Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure The Microscope: A Tool of the Scientist You may refer to pages 66-67, 72-73 in your textbook for a general discussion of microscopes.
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS 130, 131, 132, 138 & 139 COMPOUND MICROSCOPES
THE COMPOUND MICROSCOPE
THE COMPOUND MICROSCOPE In microbiology, the microscope plays an important role in allowing us to see tiny objects that are normally invisible to the naked eye. It is essential for students to learn how
IMPORTANT. 2. Avoid the use of the microscope in direct sunlight, high temperature and humidity, dust and vibration.
MODEL BHS SYSTEM MICROSCOPE This instruction manual is for use of your instrument. Before putting it into operation, we recommend you read this manual carefully in order to familiarize yourself fully with
EXPERIMENT #1: MICROSCOPY
EXPERIMENT #1: MICROSCOPY Brightfield Compound Light Microscope The light microscope is an important tool in the study of microorganisms. The compound light microscope uses visible light to directly illuminate
National Optical & Scientific Instrument Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instrument Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR STEREOSCOPIC MICROSCOPES MODEL NUMBERS 400 400TL
MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY
MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY Adapted from Foundations of Biology I; Lab 6 Introduction to Microscopy Dr. John Robertson, Westminster College Biology Department,
A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31
A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31 Phase contrast Relief contrast Incorporation of advanced UIS2 optics ensures the highest level of clarity for cell checking applications.
Compound microscope (Hund)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 Compound microscope (Hund) 15 16 17 18 19 20 1) Eyepieces (magnifies 10x), one with diopter adjustment, 2) Interp[upillary adjustment, 3) Head, 4) Revolving nosepiece,
How To Use An Asbestos Microscope
Asbestos Microscopes and Accessories Pyser-SGI has been supplying microscopes and accessories into Asbestos Laboratories for over 40 years PS12 Stage Micrometer with UKAS Certificate of Calibration - For
ISO9001 ISO14001. Environmentally-friendly product All optical components in CX41 microscope use lead-free eco-glass.
Specifications Item Optical system Illumination CX41 UIS2 (Universal Infinity-corrected) optical system Built-in transmitted Koehler illuminator 6V30W halogen bulb 100-120V/220-240Vg 0.85/0.45A 50/60Hz
First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between
Optical Differences Between Telescopes and Microscopes Robert R. Pavlis, Girard, Kansas USA icroscopes and telescopes are optical instruments that are designed to permit observation of objects and details
Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES
BIODIVERSITY I BIOL1051 Microscopy Professor Marc C. Lavoie [email protected] MAJOR FUNCTIONS OF MICROSCOPES MAGNIFY RESOLVE: => INCREASE CONTRAST Microscopy 1. Eyepieces 2. Diopter adjustment
Protocol for Microscope Calibration
Protocol for Microscope Calibration A properly calibrated system is essential for successful and efficient software use. The following are step by step instructions on how to calibrate the hardware using
2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.
Physics for Scientists and Engineers, 4e (Giancoli) Chapter 33 Lenses and Optical Instruments 33.1 Conceptual Questions 1) State how to draw the three rays for finding the image position due to a thin
SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)
SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE) We greatly appreciate your purchase of this Tamron lens. The Tamron SP AF 300mm F/2.8 LD [IF] is a fast telephoto lens developed for Canon AF single-reflex
WAVELENGTH OF LIGHT - DIFFRACTION GRATING
PURPOSE In this experiment we will use the diffraction grating and the spectrometer to measure wavelengths in the mercury spectrum. THEORY A diffraction grating is essentially a series of parallel equidistant
PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24
PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24 V112712 1 Collimation and Secondary Spacing Procedure The CDK optical design has four optical elements shown in Figure 1. The primary mirror
Microscope Lab Introduction to the Microscope Lab Activity
Microscope Lab Introduction to the Microscope Lab Activity Wendy Kim 3B 24 Sep 2010 http://www.mainsgate.com/spacebio/modules/gs_resource/ CellDivisionMetaphase.jpeg 1 Introduction Microscope is a tool
FirstView 3 Reflector Telescope Owner s Manual
FirstView 3 Reflector Telescope Owner s Manual 1. Horizontal Locking Auxiliary Screw 2. Main Mount 3. Pitching Auxiliary Knob 4. Pitching Shaft Screw 5. Rack and Pinion Focusing Knob 6. Thumb Nut for Finder
euromex microscopen bv The Netherlands www.euromex.com page1/16
euromex microscopen bv The Netherlands www.euromex.com page1/16 Introduction The Oxion series has been designed with all kind of Life Sciences applications and great durability in mind. This resulted in
Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University
Chapter 4 Microscopy, Staining, and Classification 2012 Pearson Education Inc. Lecture prepared by Mindy Miller-Kittrell North Carolina State University Microscopy and Staining 2012 Pearson Education Inc.
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODEL DC5-163 COMPOUND BIOLOGICAL MICROSCOPE WITH
M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual
M A R C O CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual CONTENTS GENERAL DESCRIPTION............... 1 INSTALLATION...................... 2 Mounting the Projector Positioning the Projector Positioning
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 ENG Instructions Thank you for purchasing a Canon product. Canon s TS-E lenses are tilt-shift lenses designed for EOS cameras. The tilt-shift mechanism enables
OLYMPUS STUDENT MICROSCOPES INSTRUCTIONS ST. HS&HSC MODELS OLYMPUS
OLYMPUS STUDENT MICROSCOPES INSTRUCTIONS MODELS ST. HS&HSC OLYMPUS OLYMPUS MICROSCOPES MODELS ST, HS, HSB, HSC This booklet describes the common features and functions of Models ST, HS. HSB and HSC of
VISM Evolution Scope Series
1 VISM Evolution Scope Series Congratulations on the purchase of your New VISM Evolution (EVO) Series Scope! The EVO Series of Scopes give you many great high end features and various magnification ranges
1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002
05-232 Imaging Systems Laboratory II Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 Abstract: For designing the optics of an imaging system, one of the main types of tools used today is optical
Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2. Before starting, make sure firearm is UNLOADED!!
I N S T R U C T I O N a n d O P E R A T I O N TRS-1 TRS-2 Tactical Rifle scope Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2 Before starting, make sure firearm is UNLOADED!!
Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.
Revision problem Chapter 18 problem 37 page 612 Suppose you point a pinhole camera at a 15m tall tree that is 75m away. 1 Optical Instruments Thin lens equation Refractive power Cameras The human eye Combining
Exercise 2. The Compound Light Microscope
6 Exercise 2 The Compound Light Microscope INTRODUCTION: Student Learning Objectives: After completing this exercise students will: a. Demonstrate proficient use of the microscope using low, high dry,
Yashica MAT EM posted 12-22-'02
Yashica MAT EM posted 12-22-'02 This camera manual library is for reference and historical purposes, all rights reserved. This page is copyright by [email protected] M. Butkus, NJ. This page may not be sold
VISM CQB Scope Series
1 VISM CQB Scope Series Congratulations on the purchase of your new VISM CQB Scope! The CQB Series of Scopes give you many great options so you can choose the scope that best fits your needs. Backed by
How to make a Galileian Telescope
How to make a Galileian Telescope I. THE BASICS THE PRINCIPLES OF OPTICS A Galileian telescope uses just two lenses. The objective lens is convergent (plano-convex), the ocular lens is divergent (plano-concave).
Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!
Instructions Manual Flexia BGA Inspection Systems This manual describes how to use Flexia BGA Inspection System Optilia Instruments 1 AB Contents 1. Safety and maintenance Instructions 3 2. About Flexia
User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up
2 Luxxor Video Microscope Set Up User Guide LUXXOR VIDEO MICROSCOPE Column When removed from its packaging, the Luxxor Video Microscope will be configured as shown, with the Vertical Slide and Slide Stop
Parts List. The HyperStar Lens Assembly includes three pieces: HyperStar Lens Secondary Mirror Holder Counterweight
The HyperStar Lens allows CCD imaging at f/2.3 with compatible Celestron 9.25 Schmidt-Cassegrain telescopes and compatible CCD cameras. These instructions show the proper methods for installing the HyperStar
18-270mm F/3.5-6.3 Di II VC PZD for Canon, Nikon (Model B008) 18-270mm F/3.5-6.3 Di II PZD for Sony (Model B008)
R 18-270mm F/3.5-6.3 Di II VC PZD for Canon, Nikon (Model B008) 18-270mm F/3.5-6.3 Di II PZD for Sony (Model B008) Thank you for purchasing the Tamron lens as the latest addition to your photographic equipment.
DSV-2 ALTITUDE-AZIMUTH TELESCOPE MOUNT User Manual
DSV-2 ALTITUDE-AZIMUTH TELESCOPE MOUNT User Manual Your New Mount Thanks for choosing the Desert Sky Astro Products DSV-2 mount. Take some time to familiarize yourself with its features (Figure 1). Please
SP AF 90mm F/2.8 Di Macro 1:1 (Model 272E)
SP AF 90mm F/2.8 Di Macro 1:1 (Model 272E) Thank you for purchasing this Tamron lens as the latest addition to your photographic equipment. Before using your new lens, please read the contents of this
LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.
LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003. STANDARDS: Students know an object is seen when light traveling from an object enters our eye. Students will differentiate
Information. From the LowVision Specialists. Guidelines for the fitting of telescopic systems
Information From the LowVision Specialists Guidelines for the fitting of telescopic systems About a successful fitting Eye care professionals dispensing telescopic spectacles must ensure they have successfully
Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03
Operator s Maintenance Manual STEINER BINOCULARS Military ruggedness and precision 07/03 W arning! When using the binocular, never point it directly at the sun. The heat generated by the focused rays of
Microscopy and Cellular Morphology
Microscopy and Cellular Morphology As we discussed in class, many organisms on the planet exist as single cells and are referred to as microorganisms bacteria, protozoans, among others. When a single microorganism
EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab
EXPERIMENT O-6 Michelson Interferometer Abstract A Michelson interferometer, constructed by the student, is used to measure the wavelength of He-Ne laser light and the index of refraction of a flat transparent
Router. A. Identify the major parts of the router. B. Complete a written test on safety and operating procedures of the router with 100% accuracy.
Router I. Competencies Given a properly adjusted router, instruction and demonstration of use, each student will be able to: A. Identify the major parts of the router. B. Complete a written test on safety
TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 1 TEC APO140 This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy. OWNER S MANUAL 2013 140
Solution Derivations for Capa #14
Solution Derivations for Capa #4 ) An image of the moon is focused onto a screen using a converging lens of focal length (f = 34.8 cm). The diameter of the moon is 3.48 0 6 m, and its mean distance from
MICROSCOPES & REFRACTOMETERS for laboratory, industry and food
Printed in Germany by & SOHN GmbH z-co-gb-kp-20152 Tradition and Innovation for 170 years An independent family business, since already 7 generations is synonymous with quality and reliability in customer
Forensic Science: The Basics. Microscopy
Forensic Science: The Basics Microscopy Chapter 6 Jay A. Siegel,Ph.D. Power point presentation by Greg Galardi, Peru State College, Peru Nebraska Presentation by Greg Galardi, Peru State College CRC Press,
Review: Amscope Metallurgical Trinocular Microscope. Michael Reese Much FRMS EMS Bethlehem, Pennsylvania USA
Review: Amscope Metallurgical Trinocular Microscope Michael Reese Much FRMS EMS Bethlehem, Pennsylvania USA Amscope is an importer and distributor of microscopes and microscopy products and accessories
RIFLESCOPE RIFLESCOPE MANUAL
MANUAL The Vortex Diamondback Riflescopes The perfect match for hunters. Solid construction from a rugged singlepiece tube of aircraft-grade aluminum is the foundation for highly reliable performance features
30 mm Diameter Main Tube 1-4x24 Models
CrossFire RIFLESCOPE RIFLESCOPE MANUAL 30 mm Diameter Main Tube 1-4x24 Models The Vortex Crossfire Riflescopes Specifically designed for discriminating hunters and shooters, the Crossfire series of riflescopes
Light and its effects
Light and its effects Light and the speed of light Shadows Shadow films Pinhole camera (1) Pinhole camera (2) Reflection of light Image in a plane mirror An image in a plane mirror is: (i) the same size
MACRO PHOTO LENS. MP-E 65mm f/2.8 1-5 ENG. Instruction
MACRO PHOTO LENS MP-E 65mm f/2.8 1-5 ENG Instruction Thank you for purchasing a Canon product. Canon Macro Photo Lens MP-E 65mm f/2.8 1-5 is a high-magnification macro lens that can magnify the subject
CrossFireII. 1-Inch Diameter Main Tube RIFLESCOPE MANUAL RIFLESCOPE RIFLESCOPE
CrossFireII MANUAL 1-Inch Diameter Main Tube The Vortex Crossfire II Riflescopes Specifically designed for discriminating hunters and shooters, the Crossfire II series of riflescopes offer the highest
AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)
AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17) Thank you for purchasing the Tamron lens as the latest addition to your photographic equipment. Di II lens (Digitally Integrated) series are designed for
RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10. Macro View. The first true macro fluorescence imaging system
The first true macro fluorescence imaging system RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10 Macro View The ultimate in macro fluorescence im The new MVX 10 MacroView from Oly Researchers are interested
EyeMag Medical Loupes from ZEISS Seeing is believing NEW! LED illumination
EyeMag Medical Loupes from ZEISS Seeing is believing NEW! LED illumination ZEISS EyeMag Medical Loupes Precision at first sight Medicine today requires meticulous attention to detail. Seeing tiny anatomical
Biological Microscope. Biological Microscope ECLIPSE E200
Biological Microscope Biological Microscope ECLIPSE E200 Features exceptionally bright and uniform LED illumination and Nikon s high-quality optics. Ergonomic and anti-mold design ensures years of comfortable
Leica MZ125. Modular high-performance stereomicroscope with 12.5:1 zoom
Leica MZ125 Modular high-performance stereomicroscope with 12.5:1 zoom The vision Leading-edge technology for a new era In research and technology the bar has been raised. Advances in science and industry
EF70-300mm f/4-5.6l IS USM
EF70-300mm f/4-5.6l IS USM ENG Instruction Thank you for purchasing a Canon product. Dedicated to EOS cameras, the Canon EF70-300mm f/4-5.6l IS USM lens is a highperformance telephoto zoom lens equipped
HISTOLOGY LABORATORY. Microscope Orientation and Blood Smear Lab
HISTOLOGY LABORATORY Microscope Orientation and Blood Smear Lab For practicing how to use the microscope DO NOT use the blood smear slide (it is too boring for the lower mags). Use a slide from the white
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,
Features: Mounting the Optic
MICRO GREEN DOT with INTEGRATED RED LASER The Patented Micro Green Dot with Integrated Red Laser is a compact optical system packed with many features. The Green Dot is designed as the primary targeting
9/16 Optics 1 /11 GEOMETRIC OPTICS
9/6 Optics / GEOMETRIC OPTICS PURPOSE: To review the basics of geometric optics and to observe the function of some simple and compound optical devices. APPARATUS: Optical bench, lenses, mirror, target
Yashica A Posted 8-26-'02
www.orphancameras.com Yashica A Posted 8-26-'02 This camera manual library is for reference and historical purposes, all rights reserved. This page is copyright by [email protected], M. Butkus, NJ. This
Infrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation
A Fishy Tale. Observing the Circulatory System of a Goldfish with a Compound Light Microscope
A Fishy Tale Observing the Circulatory System of a Goldfish with a Compound Light Microscope A Fishy Tale About this Lesson In this lesson, students will explore a computer animation of the human body
EF70-200mm F2.8L IS USM. Instruction
EF70-200mm F2.8L IS USM Instruction Thank you for purchasing a Canon USM lens. The Canon EF 70-200mm f/2.8l IS USM is a high-performance, telephoto zoom lens dedicated to Canon EOS cameras. It is equipped
CALIBRATION FOR LAL20X & LAL24X
CALIBRATION AND FAULT FINDING FOR LAL20X & LAL24X DUMPY LEVELS MEASURING EXPERTS SINCE 1869 How The LAL20X & LAL24X Works The Automatic level is called Automatic because it requires only a simple basic
Measuring. User Manual
0 1 2 3 4 5 6 7 8 9 10 11 Measuring User Manual Accessories for measuring tasks Stage micrometer (1) for calibration Graticules with various measuring pitches (2) in mm and inches Graticule with mesh (3)
V-500-PRE. 500mm F/8.0 Telephoto Lens INSTRUCTION MANUAL
V-500-PRE 500mm F/8.0 Telephoto Lens INSTRUCTION MANUAL Limited Five Year Warranty Vivitar warrants this quality product to be free of defects in material and workmanship for a period of five years from
BX2. Maintenance Manual for maintenance engineer
Maintenance Manual for maintenance engineer BX2 Thank you for purchasing the Olympus microscope BX2. In order to fully utilize its performance and secure optimum condition, please read this manual before
Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light
1.1 The Challenge of light 1. Pythagoras' thoughts about light were proven wrong because it was impossible to see A. the light beams B. dark objects C. in the dark D. shiny objects 2. Sir Isaac Newton
GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847 673-5009 email@gaertnerscientific.
7109-C-244E-R1 Field Installation of HeNe Laser in B, C, and D-Type Auto Gain Ellipsometers GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847
MICROSCOPE & OPTICAL CATALOG
MICROSCOPE & OPTICAL CATALOG Kyowa Optical Co.,Ltd General Catalog Light source attachmentφ8 +0.1 0 27 C mount 35 C mount mounting screws φ30 20 C mount C mount mounting screws Depth 4-M4 6 (for installation)
Chapter 17: Light and Image Formation
Chapter 17: Light and Image Formation 1. When light enters a medium with a higher index of refraction it is A. absorbed. B. bent away from the normal. C. bent towards from the normal. D. continues in the
RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND
Optical Resolution Charts, Ronchi Rulings and Grids The optical resolution charts are used to test characteristics such as resolution, contrast, distortion and modulation transfer function (MTF) of lenses,
ST-80 MICROSCOPE With Electronic Eyepiece #6810. User Guide
ST-80 MICROSCOPE With Electronic Eyepiece #6810 User Guide The ST-80 Microscope Thank you for purchasing your student microscope from ioptron. The ST-80 Microscope is both versatile and easy to use with
Understanding astigmatism Spring 2003
MAS450/854 Understanding astigmatism Spring 2003 March 9th 2003 Introduction Spherical lens with no astigmatism Crossed cylindrical lenses with astigmatism Horizontal focus Vertical focus Plane of sharpest
Vision Correction in Camera Viewfinders
Vision Correction in Camera Viewfinders Douglas A. Kerr Issue 2 March 23, 2015 ABSTRACT AND INTRODUCTION Many camera viewfinders are equipped with a lever or knob that controls adjustable vision correction,
PROFESSIONAL REFRACTOR MODEL 78-0040 25
30 0 30 60 90 1 2 3 4 PROFESSIONAL REFRACTOR MODEL 78-0040 25 24 22 21 20 19 5 9060 18 6 7 17 16 15 8 14 13 9 11 12 10 Figure 1 1. Objective Lens 2. Mounting Screws (2) 3. Declination Axis 4. Equatorial
LABORATORY MICROSCOPEs
LABORATORY MICROSCOPEs 2011 OPTIKA LABORATORY MICROSCOPES B-350 SERIES - Entry-level upright laboratory microscopes page 5 B-500 SERIES - High quality upright laboratory microscopes page 13 B-600 SERIES-
Instruction Manual Genesis 200 EQ
Instruction Manual Genesis 200 EQ English version 8.2014 Rev A 1 The Zoomion Genesis 200 EQ Congratulations on the purchase of the new Zoomion Genesis 200 EQ. This advanced telescope will give you hours
Use of the Microscope and Cytology
Use of the Microscope and Cytology Introduction: A true study of anatomy not only considers the large, visible structures of an organism, but also the small structures that provide the organism its form
Experiment 3 Lenses and Images
Experiment 3 Lenses and Images Who shall teach thee, unless it be thine own eyes? Euripides (480?-406? BC) OBJECTIVES To examine the nature and location of images formed by es. THEORY Lenses are frequently
The Vortex Spitfire 1x Prism Scope
REPLACE image The Vortex Spitfire 1x Prism Scope Perfect for the AR platform, the Vortex Spitfire 1x prism scope combines a compact, prism-based design with the intuitive, glass-etched DRT (Dual Ring Tactical)
Olympus BX51 Microscope & DP70 Digital Camera System
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 for Refurbished & Certified Lab Equipment Olympus BX51 Microscope & DP70 Digital Camera System The BX51 was voted
1. You stand two feet away from a plane mirror. How far is it from you to your image? a. 2.0 ft c. 4.0 ft b. 3.0 ft d. 5.0 ft
Lenses and Mirrors 1. You stand two feet away from a plane mirror. How far is it from you to your image? a. 2.0 ft c. 4.0 ft b. 3.0 ft d. 5.0 ft 2. Which of the following best describes the image from