Upflow/ Horizontal Left Condensing, Direct Vent Gas-Fired Furnace FREEDOM 95 AUH1B00A921A, AUH1B060A9361A, AUH1B080A921A, AUH1C100A981A, AUH1D100A9601A, AUH1D1A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 12-1292-01
General Features Features and Benefits NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier. AIR DELIVERY The four speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. STYLING Heavy gauge steel and wrap-around cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision. FEATURES AND GENERAL OPERATION The FREEDOM 95 High Efficiency Gas Furnaces employ a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. FREEDOM 95 Standard Equipment Power supply Convertible to horizontal left Type 29-C stainless steel secondary heat exchanger Inner blower doors Direct drive, -speed motors Silicon Nitride igniter with adaptive heat up Accessory hook-up capability Hum and EAC Quiet induced draft blower Blower door safety switch Dual solenoid combination gas valve & regulator PVC venting 1 or 2 pipe vent option Left/right gas connection Selectable cooling fan off delay eliminates need for BAY2X05 time delay relay Single wire twinning Integrated solid state control with selfdiagnostics 2 volt fuse Manual reset burner box limit Optional extended warranties 09 American Standard Heating & Air Conditioning All Rights Reserved 2 12-1292-01
Contents General Features 2 Features and Benefits 2 FREEDOM 95 Standard Equipment 2 FREEDOM 95 Optional Equipment General Data 5 AUH1B00A921A 5 AUH1B060A9361A 5 AUH1B080A921A 5 AUH1C100A981A 6 AUH1D100A9601A 6 AUH1D1A9601A 6 Performance Data 7 Electrical Data 8 Field Wiring 10 Twinning Field Wiring 11 Dimensions 12 12-1292-01 3
Features and Benefits FREEDOM 95 Optional Equipment Comfort Control, Programmable 7 Day, 3-Ht, 2-Cl... ACONT803AS32DA [ ] Comfort Control, Electric, 3-Ht, 2-Cl (Non-programmable)... ACONT02AN32DA [ ] For additional comfort control choices, see the product catalog or quick select handbook Propane Conversion Kit... BAYLPKT210B [ ] Propane Conversion Kit (stainless steel burners)... BAYLPSS210B [ ] Downflow Subbase... BAYBASE5 [ ] Filter Access Door Kit... BAYFLTR6 [ ] Side Filter Rack... BAYFLTR0 [ ] High Altitude Pressure Switch Kit AUH1B00,AUH1D100...BAYSWT01AHALTA [ ] High Altitude Pressure Switch Kit AUH1B060...BAYSWT02AHALTA [ ] High Altitude Pressure Switch Kit AUH1B080...BAYSWT03AHALTA [ ] High Altitude Pressure Switch Kit AUH1C100,AUH1D1...BAYSWT0AHALTA [ ] Concentric Vent Kit... BAYAIR30AVENTA [ ] Sidewall Vent Termination Kit... BAYVENT0B [ ] Manufactured/Mobile Home Kit...BAYMFGH100A [ ] 12-1292-01
General Data MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT PIPE DIAMETER Min (In.) 56 HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) Product Specifications 1 AUH1B00A921A Upflow / Horizontal 0,000 38,000 95.0 30-60 DIRECT 9 x 7 1 See Fan Performance Table 1/5 1075 Centrifugal Direct - 1 1/55-3000 1.0 No High Velocity 1-17x25-1in. 2 Round Aluminized Steel - Type I 2 5 2 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 2 5.2 15 H x W x D 1-3/ x 19- x 30-139 / 129 AUH1B060A9361A Upflow / Horizontal 60,000 57,000 95.0 30-60 DIRECT 10 x 7 1 See Fan Performance Table 1/3 1075 Centrifugal Direct - 1 1/55-350 1.75 No High Velocity 1-17x25-1in. 2 Round Aluminized Steel - Type I 3 5 3 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 3 9.2 15 H x W x D 1-3/ x 19- x 30-150 / 10 AUH1B080A921A Upflow / Horizontal 80,000 76,000 95.0 35-65 DIRECT 11 x 8 1 See Fan Performance Table 1075 Centrifugal Direct - 1-350 0.71 No High Velocity 1-17x25-1in. 2 Round Aluminized Steel - Type I Notes 1 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to,500 feet, derate % per 1,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace. 6 All *UH1 furnace models have a vent outlet diameter that equals 2". 5 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 10.2 15 H x W x D 1-3/ x 19- x 30-158 / 18 12-1292-01 5
General Data MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT PIPE DIAMETER Min (In.) 56 HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) Product Specifications 1 AUH1C100A981A Upflow / Horizontal 97,000 92,150 95.0 35-65 DIRECT 10 x 10 1 See Fan Performance Table 1075 Centrifugal Direct - 1 1/ - 350 0.71 No High Velocity 1 - x25-1in. 3 Round Aluminized Steel - Type I 5 5 5 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 5 12.5 H x W x D 1-3/ x 23 x 30-171 / 160 AUH1D100A9601A Upflow / Horizontal 97,000 92,150 95.0 35-65 DIRECT 11 x 10 1 See Fan Performance Table 3/ 1100 Centrifugal Direct - 1 1/ - 350 0.71 No High Velocity 1-2x25-1in. 3 Round Aluminized Steel - Type I 5 5 5 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 5 12.9 H x W x D 1-3/ x 26- x 30-197 / 185 AUH1D1A9601A Upflow / Horizontal 110,000 10,500 95.0 0-70 DIRECT 11 x 10 1 See Fan Performance Table 3/ 1100 Centrifugal Direct - 1 1/ - 350 0.71 No High Velocity 1-2x25-1in. 3 Round Aluminized Steel - Type I 6 5 6 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 6 12.9 H x W x D 1-3/ x 26- x 30-5 / 193 Notes 1 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to,500 feet, derate % per 1,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace. 6 All *UH1 furnace models have a vent outlet diameter that equals 2". 6 12-1292-01
Performance Data FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.) MODEL SPEED TAP 0.10 0. 0.30 0.0 0.50 0.60 0.70 0.80 0.90 *UH1B00A921A *UH1B060A9361A *UH1B080A921A *UH1C100A981A *UH1D100A9601A - HIGH - Black 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1 - LOW - Red - HIGH - Black 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1 - LOW - Red - HIGH - Black 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1 - LOW - Red - HIGH - Black 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1 - LOW - Red - HIGH - Black 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1 - LOW - Red - HIGH - Black 3 - MED.-HIGH - Blue *UH1D1A9601A 2 - MED.-LOW - Yellow 1 - LOW - Red *= First letter may be "A" or "T" 103 90 837 729 1359 1232 1077 926 166 1366 1175 100 1982 1892 1759 1593 2339 5 1719 136 2380 2 1695 102 992 895 798 69 1313 1199 105 913 1611 1356 1159 99 1912 1832 1712 1557 2287 21 1706 130 233 29 1690 10 930 81 752 657 126 1161 1027 895 1573 1337 115 997 1836 1765 1660 1521 2235 1996 1693 130 2287 16 168 106 885 791 705 600 1 1116 99 871 1530 1311 1130 982 1761 1696 160 185 2168 197 1671 11 221 198 1668 1397 812 726 69 55 11 1065 953 836 177 1280 1108 963 1679 1621 1536 133 2100 1897 169 1398 2193 1952 1652 1387 70 650 560 78 1079 100 90 792 121 123 1081 93 1593 1538 165 1370 21 1836 1607 1372 2118 1892 1627 1358 67 559 38 376 100 93 85 733 1360 1197 105 907 196 16 1383 129 191 177 1565 13 3 1830 1601 1328 518 305 2 919 852 768 670 1289 1139 93 866 1389 132 1275 1187 1858 1701 198 1287 1956 1771 155 1285 57 390 279 178 812 7 666 570 10 1060 929 82 1267 15 119 1068 1773 1629 131 1230 1870 1712 189 122 CFM VS. TEMPERATURE RISE Cubic Feet Per Minute (CFM) MODEL 600 700 800 900 1000 1100 10 1300 100 1500 1600 1700 1800 1900 00 2100 20 2300 200 *UH1B00A921A 59 50 39 35 *UH1B060A9361A 59 53 8 1 38 *UH1B080A921A 6 59 5 50 7 1 *UH1C100A981A 68 63 59 55 52 9 6 *UH1D100A9601A 68 63 59 55 52 9 6 2 0 38 37 *UH1D1A9601A 70 66 62 59 56 53 50 8 6 *= First letter may be "A" or "T" 12-1292-01 7
Electrical Data AUH1 Wiring From Dwg. D3398 Rev. 1 8 12-1292-01
AUH1 Schematic Electrical Data From Dwg. D3398 Rev. 1 12-1292-01 9
Field Wiring FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE 1 STAGE HEATING, 1 STAGE COOLING USING A 1 STAGE HEATING, 1 STAGE COOLING THERMOSTAT (OUTDOOR SECTION WITHOUT TRANSFORMER) FURNACE OUTDOOR UNIT (NO TRANSFORMER) SEE NOTE 6 SEE NOTE 8 TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From drawing B30388 Rv 2 10 12-1292-01
Twinning Field Wiring TWINNING CONNECTION DIAGRAM FOR TWINNING 1 STAGE FURNACES WITH SINGLE WIRE TWINNING FEATURE 1 STAGE HEAT 1 STAGE HEATING ONLY THERMOSTAT ONLY THERMOSTAT (WITH FAN SWITCH) FURNACE NO. 1 FURNACE NO. 2 BLOWER OPERATION OF UNIT NO. 2 IS SYNCRONIZED WITH UNIT NO. 1 VIA SIGNALS FROM TWIN CONNECTION. TWIN TWIN SEE NOTE ISOLATION RELAY (FIELD SUPPLIED) SEE NOTE R1 R1 ISOLATION RELAY SEE NOTE SEE NOTE 3 From Dwg. 21B3122 Rev. 3 OUTDOOR UNIT (WITH TRANSFORMER) TWINNING CONNECTION DIAGRAM FOR TWINNING 1 STAGE FURNACES WITH SINGLE WIRE TWINNING FEATURE 1 STAGE HEAT / 1 STAGE COOL THERMOSTAT 1 STAGE HEATING / COOLING THERMOSTAT FURNACE NO. 1 FURNACE NO. 2 BLOWER OPERATION OF UNIT NO. 2 IS SYNCRONIZED WITH UNIT NO. 1 VIA SIGNALS FROM TWIN CONNECTION. TWIN TWIN RC ISOLATION RELAY (FIELD SUPPLIED) SEE NOTE 3 SEE NOTE OUTDOOR UNIT (NO TRANSFORMER) R1 ISOLATION RELAY SEE NOTE SEE NOTE 5 R1 ISOLATION RELAY (FIELD SUPPLIED) SEE NOTE From Dwg. 21B3123 Rev. 2 12-1292-01 11
Dimensions AUH1 Outline Drawing (ALL DIMENSIONS ARE IN INCHES) From Dwg. C3188 Rev. 6 12 12-1292-01
American Standard Heating & Air Conditioning 60 Troup Highway Tyler, TX 75707 www.americanstandardair.com Literature Order Number 12-1292-01 File Number 12-1292-01 Supersedes New Date 06/09 American Standard Heating & Air Conditioning has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.