Monitoring technique. Motor load monitor BH 9097 VARIMETER

Similar documents
Safety technique. Emergency stop module BO 5988 safemaster

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RM4TG20 three-phase network control relay RM4-T - range V

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFE

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Quick Connect. quick - simple - efficient.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

PHOENIX CONTACT Features

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

E-STOP relays, safety gate monitors

Preset Counter signo 721

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

38 Series - Relay interface modules A

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Safety automation solutions

E-STOP relays, safety gate monitors

Power Meter Series 700

instabus KNX / EIB System System E F G H

Electronic overload relay EF19 and EF45

PNOZsigma - Base units

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Contact expansion modules

Contact expander modules

E-STOP relays, safety gate monitors

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

E-STOP relays, safety gate monitors

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MINI MCR-SL-R-UI(-SP)

Electronic overload relay EF65, EF96 and EF146

RY2 miniature industrial relays

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

48 SERIES Relay interface modules 10 A

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Thermistor motor protection

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

38 Series - Relay interface modules A

Contents. Document information

DALI RC BASIC SO. Control unit Operating instructions

E-STOP relays, safety gate monitors

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

MasterINTERFACE 39 Series - Relay interface modules

80 Series - Modular timers 16 A. Features

Pluggable interface relays CR-P Pcb relays

Control Devices Catalogue. Control Devices. Preferred and Standard Products

15 Series - Electronic step relay and dimmer. Features SERIE

3753 en /b VE/B - VE/RG Va V riable speed drives

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

is then retained absolutely without interruption.

Current and voltage measuring relays

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

MasterINTERFACE 39 Series - Relay interface modules

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

40 Series - Miniature PCB/Plug-in relays A. Features

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

49 Series - Relay interface modules A. Features

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

ACS-30-EU-EMDR-10-MOD

Relés e Contatores de Estado Sólido SIRIUS

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

80 Series - Modular timers 16 A. Features

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

60 Series - General purpose relays 6-10 A. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

A project to optimise quality and energy efficiency must include metering

Problem / Solution. The problem:

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Energy Management Energy Meter Type EM23 DIN

Speed Control Relays SX2

Transcription:

onitoring technique otor load monitor BH 9097 VARIETER 0239914 unction diagram for setting de-energised on fault* ) U According to IEC/E 60 255, DI/VDE 0435-303 Identification of - Underload P 1 and Overload P 2 - Overload P 1 (prewarning) and Overload P 2 programmable Adjustment of P 1 on absolute scale or motors up to 22 kw / 400 V; 37 kw / 600 V easurement effective power Large current range because of automatic range selection 1 changeover contact for P 1 and 1 changeover contact for P 2 Adjustable start-up delay t a Adjustable switching delay t v With automatic or manual reset, programmable Test / Reset button for easy setup Up to 40 A without external current transformer De-energised or energised on fault, programmable Also for single-phase operation LED indicators Width 45 mm A1/A2 ta t Approvals and marking Applications The BH 9097 is used to monitor variable loads on industrial motors. unction Test/Reset max / max -24 S1/S2 off -22-14 -12 The motor load monitor BH 9097 checks the active power consumption of electrical consumers. As the measuring principle is only single phase correct measurement of 3-phase load is only possible when all three phases have the same load which is normal with motors. Using DIP-switches the unit can be set up to act as under- and overload relay P 1min / P 2 max. or as overload relay with pre-warning P 1 max. /P 2 max. The settings of P 1 are absolute values and calibrated in Watts adjustable via rotational switches. 2 LEDs show the state of the corresponding output relays. The unit can be configured to energise or to de-energise on fault. Every output relay is fitted with it s own time delay t v. A start-up delay t a acts on both outputs. S1/S2 on -24-22 -14-12 min / max -24 S1/S2 off -22-14 Indication green LED, U flashing during Start-up delay t a continuous supply connected yellow LED, P 1 flashing during time delay and for set up assistance continuous when relay P 1 active (contact -14) yellow LED, P 2 flashing during time delay and for set up assistance continuous when relay P 2 active (contact -24) ault indication -12 2 different faults are displayed with the LEDs. S1/S2 on -24-22 -14-12 max/max Overload monitoring with prewarning min/max Under- and overload monitoring S1/S2 O manual reset S1/S2 O automatic reset IIIII corresponding LED is flashing *) when set to energised on fault the function of LEDs and output relays are inverted. 7954_b All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 1.) o measurement Without measuring voltage measurement is not possible - All 3 LEDs flash in sequence one after the other. The output contacts are in failure state. 2.) The BH 9097 measures negative load Possible reason The unit measures reverse power or the current connections are connected wrong. - All 3 LEDs flash simultaneously. 1 BH 9097 /.09.09 e

Connection diagrams Technical Data Input /i easuring voltage Voltage range Input resistance easuring current easuring range without auxiliary voltage 0,8... 1,1 x U with auxiliary voltage, see setting ranges 300 kω... 500 kω see setting ranges BH 9097.38/001 8012_a ominal current [A] 40 24 8 2,4 0,8 0,24 Permissible current range (overload) [A] continuously 0... 40 0... 40 0... 16 0... 8 0... 2,4 0... 1 1 min. (10 min. break) 150 150 20 16 3 1,5 20 s (10 min. break) 200 200 25 20 4 2 Input res. of current on i-k [mω] 1 1 7 14 830 830 A1 A2 A3 /i requency range 10... 400 Hz (please see characteristics 7953) Setting ranges BH 9097.38/0 8014_a P 1 und P 2 on absolute scale Switch load range for and lower range upper range easuring accuracy (in % of setting value) Hysteresis (in % of setting value) < 5 % Harmonic distortion < 40 % Reaction time Switching delay / Start-up delay t a Setting ranges ± 4 % (2 % on request) < 50 ms 0... 10 s (infinite variable) 0... 30 s (infinite variable) Available variants easuring voltage U easuring current I [A] load range BH 9097.38 A1 A2 A3 80_a 8013_a 1-phase without auxiliary voltage BH 9097.38/000 AC 230 V 0,0024... 0,24 0,1... 60 W AC 230 V 0,024... 2,4 1... 600 W AC 230 V 0,24... 24 10... 6000 W with auxiliary voltage BH 9097.38/010 AC 35...250 V 0,0024... 0,24 0,1... 60 W AC 35...250 V 0,024... 2,4 1... 600 W AC 35...250 V 0,24... 24 10... 6000 W 3-phase without auxiliary voltage BH 9097.38/001 3 AC 400 V 0,008... 0,8 0,1... 60 W 3 AC 400 V 0,08... 8 10... 6000 W 3 AC 400 V 0,4... 40 0,1... 30 kw with auxiliary voltage BH 9097.38/0 3 AC 60... 440 V 0,008... 0,8 1... 600 W 3 AC 60... 440 V 0,08... 8 10... 6000 W 3 AC 100... 760 V 0,4... 40 0,1... 52 kw Auxiliary circuit BH 9097.38/010 Auxiliary voltage U H only for BH 9097.38/010, BH 9097.38/0 AC 0 V (lemmen A 1 - A 2), AC 230 V (lemmen A 1 - A 3), DC 24 V Voltage range 0,8... 1,1 U H requency range of U H 45... 400 Hz Input current AC 0 V approx. 30 ma AC 230 V approx. 15 ma DC 24 V approx.. 50 ma 2 BH 9097 /.09.09 e

Technical Data Output Contacts 1 changeover contact for 1 changeover contact for Thermal current I th 2 x 5 A Switching capacity to AC 15 O contact 3 A / AC 230 V IEC/E 60 947-5-1 C contact 1 A / AC 230 V IEC/E 60 947-5-1 to DC 13 1 A / DC 24 V IEC/E 60 947-5-1 Electrical life to AC 15 at 3 A, AC 230 V 2 x 10 5 switching cycles IEC/E 60 947-5-1 Permissible switching frequency 1800 switching cycles / h Short circuit strength max. fuse rating 4 A gl IEC/E 60 947-5-1 echanical life 30 x 10 6 switching cycles General Data Operating mode continuous Temperature range - 20... + 55 C Clearance and creepage distances rated impuls voltage / pollution degree 4 kv / 2 IEC 60 664-1 EC Electrostatic discharge 8 kv (air) IEC/E 61 000-4-2 H-irradiation 10 V / m IEC/E 61 000-4-3 ast transients 2 kv IEC/E 61 000-4-4 Surge voltages between wires for power supply 1 kv IEC/E 61 000-4-5 between wire and ground 2 kv IEC/E 61 000-4-5 H-wire guided 10 V IEC/E 61 000-4-6 Interference suppression Limit value class B E 55 0 Degree of protection Housing IP 40 IEC/E 60 529 Terminals IP 20 IEC/E 60 529 Housing Thermoplastic with V0 behaviour according to UL subject 94 Vibration resistance Amplitude 0,35 mm frequency 10... 55 Hz IEC/E 60 068-2-6 Climate resistance 20 / 055 / 04 IEC/E 60 068-1 Terminal designation E 50 005 Wire connection Load terminals Control terminals Wire fixing 1 x 10 mm 2 solid or 1 x 6 mm 2 stranded wire with sleeve 1 x 4 mm 2 solid or 2 x 1,5 mm 2 stranded wire with sleeve or 1 x 2,5 mm 2 stranded wire with sleeve DI 46 228-1/-2/-3/-4 Box terminals with self-lifting wire protection and Plus-minus terminal screws 3,5 ounting DI rail IEC/E 60 715 Weight 430 g Dimensions Width x height x depth Standard type 45 x 84 x 1 mm BH 9097.38/001 3 AC 400 V 50 / 60 Hz t a 30 s t v 10 s Article number 0053944 3-phase, without auxiliary supply Output 1 changeover contact for and 1 changeover contact for ominal voltage U 3 AC 400 V Width 45 mm Variants BH 9097.38/0 BH 9097.38/000 BH 9097.38/010 BH 9087.38/1 3-phase with auxiliary supply 1-phase without auxiliary supply 1-phase with auxiliary supply With galvanically separated current path. or applications with current transformers grounded on the secondary side, current range limited to 25 A Ordering example for variants BH 9097.38 /0 3 AC 50...690 V AC 0 V + AC 230 V Characteristics i (A) I 0 50 Settings 400 7953 f (Hz) ax. input current curve in relation to input frequency I (A) 6 5 4 3 2 1-20 0 +20 +40 +55 continuous current limit curve (current over 2 contacts) T ( C) 8367 2 rotational switches for P 1 Value P 1 (2 decades) 2 rotational switches for P 2 Value P 2 (2 decades) Potentiometer time delay for value P 1 Potentiometer time delay for value P 2 Potentiometer t a Test/Reset-Taste Dip-switches x10 x1 A R P 2 max. P 2 max. P 1 max. P 1 min. 30 s 10 s Switching delay tv Start-up delay ta Auxiliary voltage U H ominal voltage U of input circuit Variant, if required Contacts Type start-up delay after connection voltage Test function as setting assistance Reset function when manual reset is selected upper / lower load range closed or open circuit operation for output relays 2 AX switching values (Overload with Pre-warning) or AX and I switching value (Overload / Underload monitoring) S1 O O manual / automatic reset for P 1 S2 O O manual / automatic reset for P 2 Connection The device has to be connected according to the connection diagrams. The motor is connected to terminals and or /i and. The flow direction of the current has to be observed. On reverse power the unit gives a fault signal. The max continuous motor current is 40 A limited by the terminals. With higher currents a current transformer with 2,5 VA has to be used. 3 BH 9097 /.09.09 e

Set up procedure and setting instructions of value (unit) load range Adjustemt example response value 2,5 kw 9950 of value (ten s) yellow LED for value P 2 setting of delay time t V2 for green LED U for U (continuous light) t a (flashing light) yellow LED for value P 1 setting of delay time t V1 for of value (ten s) of value (unit) 8366 open/closed circuit operation selection P 1max. /max. or P 1min. / max. manual/automatic reset P 2 manual/automatic reset P 1 setting of start up delay t a Test/Reset button 2 5 x 0,1 = 2,5 kw Response value = 25 x 0,1 = 2,5 kw The adjustment of the unit can be made without additional measuring equipment and calculations. Please make sure that the load values are in the permitted operating range of the unit. Based on the max permitted values the BH 9097 can be used for 48 kw 3-phase motors at 3 AC 690 V and 5.8 kw single phase motors at AC 230 V. There are three methods to set up the unit ethod 1 If the absolute values of the actual required tripping points P 1 are known, they can be set directly on the unit ( of P 1 ). ethod 2 This method is recommended when it is possible to simulate the different load situations during set-up. In this case nothing has to be calculated. Turn the delay time for P 1 to min. The motor runs in underload while the Pot 1 is turned until the output relay switches. The same has to be done for overload. ow the unit is set accurately. ow adjust the operate delay and the start-up delay to the required values. Pressing the test / reset button during setup disables the switching of the output relays. The LEDs of P 1 flash. ethod 3 This method is the most simple one but not the most accurate. The operate delay is set to min. The motor is switched on and runs on nominal load. With both potentiometers the set points are searched by slowly turning the max. Pot from high to low value and the min. Pot from low to high value until the corresponding output relays switch. After that turn the Pot P 2 to the right (e.g. + 10 %) side and the Pot P 1 to the left (e.g. - 10 %) until the output relays reset. The unit is now set and responds if the load differs from the nominal value. inally set the operate delay and start-up delay to the required values. The DIP switch should be set to P 1 min / P 2 max. Connection examples single phase L A1 A2 A3 8018_a 8020_b BH 9097.38 BH 9097.38/010 4 BH 9097 /.09.09 e

Connection examples 3-phase /i A1 A2 A3 /i 3~ 8019_a 3~ 80_b BH 9097.38/001 BH 9097.38/0 Connection examples with external current transformer single phase 3-phase L I i k I i k /i 8602 3~ 8603 BH 9097.38 BH 9097.38/001 ote When using external CTs the adjusted value has to be multiplied with the transmission ratio (ü) of the CT. Example Switching value = Setting value (/) x ü 5 BH 9097 /.09.09 e

E. DOLD & SÖHE G D-784 urtwangen PO Box 1251 Telephone (+49) 77 23 / 654-0 Telefax (+49) 77 23 / 654-356 e-mail dold-relays@dold.com internet http//www.dold.com BH 9097 /.09.09 e 6