School of Engineering Science Mechatronics Systems Engineering. ENSC 283: Friction and Minor Losses in Pipelines

Similar documents
Experiment 3 Pipe Friction

FLUID FLOW Introduction General Description

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts

Pressure drop in pipes...

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Experiment # 3: Pipe Flow

Experimentation and Computational Fluid Dynamics Modelling of Roughness Effects in Flexible Pipelines

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Chapter 8: Flow in Pipes

Hydraulic losses in pipes

Pipe Flow-Friction Factor Calculations with Excel

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

MATLAB AS A PROTOTYPING TOOL FOR HYDRONIC NETWORKS BALANCING

Experiment (13): Flow channel

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

Swissmetro travels at high speeds through a tunnel at low pressure. It will therefore undergo friction that can be due to:

HEAVY OIL FLOW MEASUREMENT CHALLENGES

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

Minor losses include head losses through/past hydrants, couplers, valves,

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

Equipment for Engineering Education

HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long

Steady Flow: Laminar and Turbulent in an S-Bend

Water hammering in fire fighting installation

Chapter 3.5: Fans and Blowers

Heat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts

Darcy Friction Factor Formulae in Turbulent Pipe Flow

Open channel flow Basic principle

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.

The University of Toledo Soil Mechanics Laboratory

Pipe Flow Experiments

Lab 1a Wind Tunnel Testing Principles & Lift and Drag Coefficients on an Airfoil

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

Lecture 5 Hemodynamics. Description of fluid flow. The equation of continuity

Backwater Rise and Drag Characteristics of Bridge Piers under Subcritical

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS

Module 9: Basics of Pumps and Hydraulics Instructor Guide

CEE 370 Fall Laboratory #3 Open Channel Flow

Contents. Microfluidics - Jens Ducrée Physics: Fluid Dynamics 1

Urban Hydraulics. 2.1 Basic Fluid Mechanics

A Comparison of Analytical and Finite Element Solutions for Laminar Flow Conditions Near Gaussian Constrictions

Centrifugal Fans and Pumps are sized to meet the maximum

Open Channel Flow. M. Siavashi. School of Mechanical Engineering Iran University of Science and Technology

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

CFD Analysis of a butterfly valve in a compressible fluid

OUTCOME 1 STATIC FLUID SYSTEMS TUTORIAL 1 - HYDROSTATICS

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE DOUBLE PIPE HEAT EXCHANGER

Calculating resistance to flow in open channels

A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Class A Foam Mixing and Application Equipment

Chapter 13 OPEN-CHANNEL FLOW

Department of Chemical Engineering, National Institute of Technology, Tiruchirappalli , Tamil Nadu, India

SIZING AND CAPACITIES OF GAS PIPING

Abaqus/CFD Sample Problems. Abaqus 6.10

Flow Measurement Options for Pipeline and Open Channel Flow

Lecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics

Theory overview of flow measurement using differential pressure devices based on ISO-5167 standard.

Using CFD to improve the design of a circulating water channel

PRESSURE DROP STUDIES IN WAVY CORRUGATED PLATE HEAT EXCHANGERS

Pacific Pump and Power

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

Scientific Graphing in Excel 2010

Water Supply. Simulation of Water Distribution Networks. Mohammad N. Almasri. Optimal Design of Water Distribution Networks Mohammad N.

Enhancement of heat transfer of solar air heater roughened with circular transverse RIB

Special Linings for unusual service conditions. Please contact ACIPCO.

LECTURE 1: Review of pipe flow: Darcy-Weisbach, Manning, Hazen-Williams equations, Moody diagram

CE 6303 MECHANICS OF FLUIDS L T P C QUESTION BANK PART - A

A TEST RIG FOR TESTING HIGH PRESSURE CENTRIFUGAL COMPRESSORS MODEL STAGES AT HIGH REYNOLDS NUMBER

= water horsepower WHP brake horsepower QH WHP = (222) ( 33,000 ft-lbs/min-hp)( gal/ft ) 1 HP=0.746 kw

Introduction to COMSOL. The Navier-Stokes Equations

du u U 0 U dy y b 0 b

Technical data. Danfoss DHP-A

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

Pressure -Temperature Relationship in Gases. Evaluation copy. Figure ml Erlenmeyer flask. Vernier computer interface

Piping Hydraulic Line Design and Sizing Software KLM Technology Group

Unit 24: Applications of Pneumatics and Hydraulics

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Air Flow Measurements

HEAT TRANSFER ENHANCEMENT AND FRICTION FACTOR ANALYSIS IN TUBE USING CONICAL SPRING INSERT

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Dependency of heat transfer rate on the Brinkman number in microchannels

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

TEMPERATURE, CONCENTRATION, AND PUMPING EFFECTS ON PAM VISCOSITY

Turbulence Modeling in CFD Simulation of Intake Manifold for a 4 Cylinder Engine

OUTCOME 3 TUTORIAL 5 DIMENSIONAL ANALYSIS

Note: first and second stops will be reversed. Bring clothing and shoes suitable for walking on rough ground.

THE PSEUDO SINGLE ROW RADIATOR DESIGN

Air-side Systems: Air Duct Design

CHAPTER 3 STORM DRAINAGE SYSTEMS

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Transcription:

Objective To measure flow losses and pressure characteristics of different pipes and piping components. Apparatus The experimental setup shown in Fig. 1 is equipped with independent pressure measuring systems, which enable one to measure relative and absolute pressure over a wide range. A variable-area flow meter is used for measuring the volumetric flow rate. Water is fed into the system using a centrifugal pump. Water first passes through flow meter and the inlet valve. Then, water enters the selected pipe section via the inlet hose, see Fig. 2. The pressure is measured at measuring glands at the beginning and the end of the measuring section. Finally, water returns into the tank using a second hose. Using the experimental setup, overall pressure loss can be measured in the following components: - PVC, copper, galvanized steel pipes. - Turns, bends. - Sudden expansions or contraction. - Slanted seat, membrane, and check valves. Moreover, the employed setup can be connected to a PC to record the measurements for further investigations. The flow rate, differential pressure, excess pressures and the temperature are also shown on digital displays in the switch cabinet. The pressure drop can be measured using double tube manometer or differential sensor. The double tube manometer allows both differential pressures and gauge pressures to be measured in mm column of water. The measuring range of double tube manometer is 0-680 mm column of water. The differential pressure is measured with the bleed valve closed and the excess pressure with the bleed valve open. The measuring points are connected to the bottom of the level tubes using quick action hose couplings. The differential pressure unit has 2 connections, P1 and P2 (1), between which differential pressure up to a maximum of 200 mbar can be measured. 1

1 Laboratory trolley 10 Vane impeller flow meter 2 Water tank with immersion 11 Inlet regulator valve pump 3 Master switch 12 Interchangeable measuring objects 4 Switch for pump 13 Various measuring sections 5 Digital displays for flow and 14 Tank drain valve pressure 6 Double level tube manometer 15 Differential pressure sensor 7 Six tube manometer 16 Return valve 8 Electronic pressure sensor 17 Return pipe 9 Thermometer Figure 1- Components of experimental apparatus. 2

1 Return pipe with return 6 Cross-section expansion PVC 20 32 valve to water tank 2 Galvanized steel pipe, 1/2" 7 Section for interchangeable measuring objects 3 Cu-pipe 18 x 1 8 Pipe bend, pipe angle PVC 20x1.5 4 PVC-pipe 20 x 1.5 9 Self closing measuring glands 5 Cross-section constriction PVC 20-16 Figure 2- View of the setup test section. Software The software has two main windows, system diagram and measurement diagram. The system diagram is a clearly arranged representation of the measuring task. The lower button can be used to toggle between different measuring tasks, including: Pipe, Nozzle/orifice, Pitot tube, Pipeline fittings, and Venturi tube. Pressures can be represented as water columns or using a differential pressure gauge. To change the setting, use the View option in the menu. The flow, pressures and temperature are displayed online. 3

The Start option takes you to the measurement diagram option. This window can be used to create the diagrams. In the measurement diagram window, click on Start in the menu bar to record, load and save a curve. Clicking on the button with the red spot records measured data and adds it to the active data series. In summary the following steps should be followed: - Open the measurement diagram window under Start in the menu bar. - Create a new measuring series ( New series ) under File in the menu bar. - If necessary, specify the axes for the diagram. This setting is made using View and choose axis in the window that is subsequently opened. You can select a maximum of four different y-axes and one x-axis. - You can then record measured data using the record button or by selecting the take record option under Edit in the menu bar. - After recording the measuring series, you can save it to the hard disk or an alternative medium using the save series command in the File menu. Theory Assuming steady-state, incompressible, and 1D flow, the energy equation becomes: 2 2 where is the pressure loss between sections 1 and 2, V is the average velocity, z is the elevation from a reference point, and is the density. Two main sources exist for pressure drop in pipelines: 1) Friction loss and wall shear stress. 2) Minor loss, which is caused by changes in the geometry. For fully-developed flow in channels frictional pressure drop can be calculated from Darcy-Weisbach equation: (2) 2 where is the friction factor, d and l are channel diameter and length, respectively. The friction factor is related to the flow regime. Reynolds number is a good criterion for prediction of flow regime: (3) (1) 4

where is the viscosity of the fluid. For laminar flows where Re<2300, f is calculated as: 64 (4) In turbulent flows, i.e., Re>2300, f is a function of both Reynolds number and pipe roughness, k. For hydraulically smooth pipes, Re < 65 d/k, and a Reynolds number in the range of 2320<Re <10 5 the pipe friction coefficient is calculated using the Blasius formula: 0.3164 (5) For rough pipes the pipe friction coefficient is read from Moody diagram or evaluated using Colebrook formula: 2 2.51 0.27 (6) Special pipe components and fittings such as pipe bends or elbows, pipe branches, changes in crosssection, and valves alter flow geometry and produce additional pressure losses apart from the wall friction losses. These minor losses can be calculated from the following relationship: (7) 2 where is the coefficient of resistance. Therefore, when a fitting or a connection exists in a pipe of length l and the total pressure drop in the system is known, the coefficient of resistance of the fitting is found from the following equation: 2 g Procedure Before starting the experiment: - Place experimental unit on a flat surface and secure against rolling away (brake). - Fill up water tank. - Connect to power supply. In this experiment, pipes made of different materials (PVC, copper and galvanized steel) are compared. The measuring length is 1000 mm. - Connect the double tube manometer to the pressure glands on the pipes. (8) 5

- Start the pump and measure the pressure drop across the pipe. - Repeat the experiment for different flow rates. Plot the measured values of pressure drop versus Reynolds number and compare it with the values obtained from theoretical relationships. The changes in cross-section available on the experimental unit take the form of continuous expansion or constriction. - Connect double tube manometer or differential pressure sensor - Measure pressure drop for several volume flow rates and evaluate the resistance coefficient of expansion and constriction fittings. Compare the experimental data with theoretical results, see Discussion 2. It should be noted that = 145 mm. Discussion 1) Starting from differential equations governing fully-developed flow in circular pipes, derive equation (4). 2) Find an equation for prediction of coefficient of resistance in expansion and constriction junctions. 3) How does the flow regime affect the coefficient of resistance in the considered fittings? 6

Appendix 1 (Measurements) Pipe section type Diameter (mm) Volumetric flow rate Inlet pressure Outlet pressure Temperature Galvanized steel, 1/2" 16 Galvanized steel, 1/2" 16 PVC, 18 1 16 PVC, 18 1 16 Copper, 20 1.5 17 Copper, 20 1.5 17 Expansion 17 to 28.6 Expansion 17 to 28.6 17 to14.5 17 to14.5 7

Appendix 2 (Calculations) Pipe section Volumetric flow rate ( /) Reynolds number / Galvanized steel, 1/2" Galvanized steel, 1/2" PVC, 18 1 PVC, 18 1 Copper, 20 1.5 Copper, 20 1.5 Expansion Expansion 8

Pipe section Volumetric flow rate f Pressure drop (theoretical) Pressure drop (experimental) Relative Difference (%) Galvanized steel, 1/2" Galvanized steel, 1/2" PVC, 18 1 PVC, 18 1 Copper, 20 1.5 Copper, 20 1.5 Fitting Volumetric flow rate f Pressure drop Minor pressure drop Coefficient of resistance () Expansion Expansion 9