UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE DOUBLE PIPE HEAT EXCHANGER

Size: px
Start display at page:

Download "UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 DOUBLE PIPE HEAT EXCHANGER"

Transcription

1 UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE DOUBLE PIPE HEAT EXCHANGER OBJECTIVE Determine the Reynolds number for each flow. Determine the individual heat transfer coefficients for the inside and outside of the tube. Determine the experimental overall heat transfer coefficient, U, (based on the inside area of the hot tube and the log mean temperature) and the theoretical overall heat transfer coefficient, U, (based on the inside area of the hot tube and the individual heat transfer coefficients). Compare the calculated data for the parallel and co-current flows and the laminar, transition and turbulent flows (dependent on which ones you were asked to collect data for). INTRODUCTION In many heat transfer processes, heat is transferred from one fluid to another through a solid wall. The exchanger geometry, fluid properties, and flow rates are the parameters that influence the rate of heat transfer. A study of these parameters forms the basis for design of heat exchangers. A double pipe heat exchanger is a simple, low cost configuration normally preferred for applications requiring heat transfer areas less than about 10 m 2. REFERENCE Your text on Heat Transfer Holman, J.P., "Heat Transfer", McGraw Hill, Fifth Edition, New York, N.Y., 1981, Chapter 10, pp McCabe, W.L., Smith, J.C., Marriott, P., "Unit Operations of Chemical Engineering", 4th Edition, McGraw-Hill,

2 EQUIPMENT 1. Double pipe heat exchanger (Technovate 9052) 2. Digital thermometer 3. Stopwatch gallon plastic bottles 5. Calipers 6. Open end wrench 7. Samples of heat exchange tubes. 8. Top loading balance CHEMICALS/MATERIALS 1. Hot water 2. Cold water 2

3 Figure 1. Model 9052 Flow Diagram PROCEDURE Collect flow and temperature data in both the parallel and counter flow modes using hot water flowing through the inner pipe. The possible combinations of flow regimes are shown in Table I. The lab instructor will inform each group prior to the lab which flow mode(s) and flow rates to use in the experiment. 3

4 Table I. Experimental Flow Rates HOT WATER COLD WATER Laminar (Re<2100) Transition (2100<Re<4000) Turbulent (Re>4000) Laminar (Re<2100) Transition (2100<Re<4000) Turbulent (Re>4000) Laminar (Re<2100) Transition (2100<Re<4000) Turbulent (Re>4000) Laminar (Re<2100) Transition (2100<Re<4000) Turbulent (Re>4000) The configuration of the heat exchanger is shown in Figure 1. Counter flow or parallel flow is chosen by switching valve V-17. Counter-clockwise (ccw) for parallel flow and clockwise (cw) position for counter flow. 1. Calculate the flow rates at which laminar, transient and turbulent flow will occur [(gm/sec) or (ml/sec)]. You should know prior to the lab experiment how to calculate the Reynolds number for both the hot and cold water flows in the heat exchanger. 2. Ensure that all the valves in the system are closed. Open the two green handle water shut off valves located below the heat exchangers on the wall. 3. Fully open the flowmeter output valve V-15, the drain valve V-16, the cold water supply valve V-5, the hot water inlet valve V-2 and the mixer output flow control valve V For the first set of experimental temperature readings, set valve V-17 to parallel or counter flow depending on which mode you are to collect data in. For hot water, valve V-3 should be closed. Adjust the hot and cold water flows with valves V-13 and V-14 respectively. You can switch valve V-18 to divert either hot or cold water flow through the flow meter to get an approximate flow. Actual flow rates should be determined volumetrically by weighing a volume of water collected over a period of time. Note: Flow rates in the laminar range are very small. 5. Allow the heat exchanger to reach steady state. (Note: This may take up to 20 minutes on initial start up due to the long lag time in the building hot and cold water piping, especially when water is not being used frequently. After initial start up, steady state should be reached within a minute or two. Monitor temperatures to determine when steady state is reached.) 6. If the experiment is run using the computer for data acquisition, Appendix A will be attached and should be consulted before proceeding to the next step. 7. Record the temperatures and the flow rates (weight of liquid collected over a period of time) of the hot and cold fluids. The temperatures are monitored through the use of 4

5 thermocouples IT-9 and IT-11 for the hot fluid; OT-1 and OT-6 for the cold fluid; and ST-1, ST-2 and ST-4 for the outer surface temperature of the inner tube. If the computer data acquisition program is used, the data from each thermocouple will be collected every second. Six hundred (600) data points for each thermocouple will be collected over a period of 10 minutes. Hot and cold water flows should be collected in triplicate during this period of time. 8. The hot and cold water flows should be recorded on paper and entered into the spreadsheet after the temperature data has been collected (the run finished). If you press Enter or click on another cell to enter data into a cell at the same time that data is being entered into a cell by the data acquisition system, the data acquisition system will lock up and you may lose your data. You will have to restart the run. (There are times when the computer will have to be rebooted.) 9. The spreadsheet should be saved after each run. 10. Adjust the flow rates to the next desired flow rate. Repeat steps Reverse V-17 if you have to collect data in the opposite mode and repeat steps 5-8. The heat exchanger should reach steady state within a minute or two. Monitor temperatures to determine when steady state is reached and then start data collection. 12. Continue adjusting flow rates and repeat steps 4-8 until temperature data is collected for all the modes and flow rates you have been assigned. 13. Upon completion of this experiment, close both of the green handle water shut-off valves under the unit. Allow the water to drain out of the system. Then close all valves tight and back off 1/4 turn. SAFETY NOTES 1. Safety glasses with side shields shall be worn at all times during the experiment. Hot and cold water is used in this experiment under building main pressure reduced to approximately 30 psi. There is a chance of a tube bursting or a valve leaking water and start to spray the area around the area of the heat exchanger. 2. Prior to operation of the system, familiarize yourself with the equipment. Trace all process lines, test all valves, and ensure that all valves are closed. 3. Cold water should be admitted first and then the hot water in order to avoid damage due to thermal expansion. 4. While admitting hot water to the system, open the valves cautiously and check all connections for possible leaks. 5. At the end of the experiment, the hot water supply should be shut off first. Allow the cold water to circulate for a couple of minutes before shutting off the cold water supply. 6. Be aware of unlagged hot water lines, they heat up rapidly. 7. If a valve appears tight or doesn't yield to hand force, do not attempt to turn it with a wrench. Turn off the hot water, permit the system to drain and cool down, then loosen the packing bonnet slightly and try again. 5

6 8. Keep the laboratory working space clean and uncluttered. Be aware of potential hazards such as wet spots or debris on floors that could cause slips or falls. WASTE DISPOSAL PROCEDURES 1. There is no waste associated with this experiment. Only hot and cold water are used in this experiment and they can be sent to the drain. 08/2012 6

7 APPENDIX A Double Pipe Heat Exchanger Computer Data Acquisition Instructions The temperature data is collected with a DATAQ DI-1000TC Instrumentation module for Temperature measurement. The software program WinDaq/Lite will be used for data acquisition. 1. Connect the thermocouple (TC) wires to the DI-1000TC box. 2. Connect the USB cable from the DI-1000TC box to the USB port on the portable computer. 3. Turn on the computer and select the student account in Windows XP. Enter student as the password. Wait for Windows XP to finish loading. 4. Double click on the WinDaq 1000TC shortcut icon on the desktop to load the data acquisition software. 5. A window opens (DI-1000 Acquisition 0) showing an oscilloscope tracing of the temperatures for 7 thermocouples. The data as it is displayed moves from left to right. When the cursor reaches the right side of the window it starts again at the left side of the graph. The mode of data display can be changed but this is probably the best way to view the data on the monitor. 6. The software has been configured to collect 1 data point/sec/tc (7 samples/sec). Over a 10 minute period 600 temperature data points are collected for each thermocouple. The number of data points/sec/tc and the length of the sample time can be changed but for this experiment, this is the best configuration. If it is not set up right, see the Lab Services Coordinator. 7. Set up the heat exchanger in the proper configuration so it is operating to your satisfaction. 8. During the 10 minute period you collect temperature data you will also collect 3 sets of hot and cold water in 1 gallon white buckets for your mass flow data. 9. On the computer desktop, double click on the Excel icon to start Excel. 10. A small dialogue box appears on the spreadsheet. This dialogue box is named WinDaq- XL. Click on the circle in this box to open up another dialogue box. a. Under Select the WinDaq Device click on DI-194 Serial Device (xx) b. In the Starting Cell entry field, enter the cell designator for the upper left corner where you want to begin putting the data. A1 is the default. If you want to begin in another row or column enter that cell designator. c. In the Rows to Fill entry field enter data points will be collected over the 10 minute period (10 min x 60 sec/min x 1 data point/sec) for each thermocouple. When 600 data points have been collected the program will stop importing the data into the spreadsheet. d. Click on start to begin data acquisition. 7

8 11. The program automatically puts EC in each of the columns in the first row of the designated starting cell. 12. The thermocouple name for each column is listed below. They are the same as channels 1, 2, 3, 4, 5, 6, 7 shown on the oscilloscope chart in the data acquisition program. Column 1 Column 2 Column 3 Column 4 Column 5 Column 6 Column 7 NOTE: IT-9, Hot Water in IT-11, Hot Water out OT-1, Cold Water in/out (dependent on whether parallel/counter flow) OT-6, Cold Water in/out (dependent on whether parallel/counter flow) ST-1, Surface temperature 1 (Temperature of the outside surface of the inside [hot water] tube. ST-2, Surface temperature 2 (Temperature of the outside surface of the inside [hot water] tube. ST-4, Surface temperature 4 (Temperature of the outside surface of the inside [hot water] tube. ST-3, Surface temperature 3 has a broken thermocouple so it cannot be used. 13. The data from additional experimental runs can be put to the right of the previous run. Data can not be collected in columns beyond column HZ. Data from each experimental run can also be put into a new sheet. 14. Do not enter data into the spreadsheet while it is collecting data from Windaq. If you press Enter or click on another cell to enter data into a cell at the same time that data is being entered into a cell by the data acquisition system, the data acquisition system will lock up and you may lose your data. You will have to restart the run. (There are times when the computer will have to be rebooted.) 15. The spreadsheet should be saved after each run. 08/2012 8

9 Department of Chemical Engineering Stockroom Checkout slip Double Pipe Heat Exchanger ChE 3211 Name: (print name) Date: Lab No.: Lab 1 Tuesday 12:00-4:50 PM Lab 2: Thursday 12:00-4:50 PM Lab No.: Lab 3 Tuesday and Thursday morning (9:30-11:50 AM) (circle one) Equipment Out In Equipment Out In Stopwatch Calipers Name: (Signature) 9

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 CONVECTIVE HEAT TRANSFER

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 CONVECTIVE HEAT TRANSFER UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 CONVECTIVE HEAT TRANSFER OBJECTIVE The purpose is to measure heat transfer in cases where convection is a significant mechanism.

More information

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 ABSORPTION OF CARBON DIOXIDE INTO WATER

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 ABSORPTION OF CARBON DIOXIDE INTO WATER UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 ABSORPTION OF CARBON DIOXIDE INTO WATER OBJECTIVE The objective of this experiment is to determine the equilibrium line,

More information

ME 315 - Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

ME 315 - Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS ME 315 - Heat Transfer Laboratory Nomenclature Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS A heat exchange area, m 2 C max maximum specific heat rate, J/(s

More information

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials. Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials. Attachment C1. SolidWorks-Specific FEM Tutorial 1... 2 Attachment C2. SolidWorks-Specific

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

VAPOR PRESSURE AS A FUNCTION OF TEMPERATURE. This laboratory covers material presented in section 11.8 of the 9 th Ed. of the Chang text.

VAPOR PRESSURE AS A FUNCTION OF TEMPERATURE. This laboratory covers material presented in section 11.8 of the 9 th Ed. of the Chang text. VAPOR PRESSURE AS A FUNCTION OF TEMPERATURE Objectives: (1) Observe and measure the change in the vapor pressure (dependent variable) as a function of temperature (independent variable). (2) Analyze the

More information

XControls Bring Applications to Life

XControls Bring Applications to Life XControls Bring Applications to Life Create Stunning Graphical User Interfaces Featuring: Realistic Look and Feel Custom Component Sizing Compact Code Royalty-free Distribution when Designed in Your Application

More information

CHEG 3128 Heat, Mass, & Kinetics Laboratory Diffusion in Laminar Flow Regimes Modeling and COMSOL Tutorial Tutorial by Andrea Kadilak

CHEG 3128 Heat, Mass, & Kinetics Laboratory Diffusion in Laminar Flow Regimes Modeling and COMSOL Tutorial Tutorial by Andrea Kadilak CHEG 3128 Heat, Mass, & Kinetics Laboratory Diffusion in Laminar Flow Regimes Modeling and COMSOL Tutorial Tutorial by Andrea Kadilak Introduction COMSOL is a computer modeling software package that will

More information

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS J.Kalil basha 1,G.Karthikeyan 2, S.Karuppusamy 3 1,2 Assistant Professor, Dhanalakshmi Srinivasan

More information

AMX300 DirectConnect Mixing Valve Kits

AMX300 DirectConnect Mixing Valve Kits AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates

More information

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P2.6.3.2. Thermodynamic cycle Heat pump

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P2.6.3.2. Thermodynamic cycle Heat pump Heat Thermodynamic cycle Heat pump LD Physics Leaflets P2.6.3.2 Investigating the function of the expansion valve of the heat pump Objects of the experiment g To study the operational components of the

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati Module No. # 04 Convective Heat Transfer Lecture No. # 03 Heat Transfer Correlation

More information

Installing the IF-NMEASC & SC30 Windows XP Drivers & Software

Installing the IF-NMEASC & SC30 Windows XP Drivers & Software Installing the IF-NMEASC & SC30 Windows XP Drivers & Software The following document will outline the installation and use of the IF-NMEASC and SC-30 USB drivers and SC-30Tool software in three parts:

More information

FILLING AND PURGING THE SYSTEM

FILLING AND PURGING THE SYSTEM FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation

More information

Vertical Tube Heat Exchanger (VTHX) or The Heat Exchanger Network (HEN) Control Process. Operating Manual

Vertical Tube Heat Exchanger (VTHX) or The Heat Exchanger Network (HEN) Control Process. Operating Manual Vertical Tube Heat Exchanger (VTHX) or The Heat Exchanger Network (HEN) Control Process Operating Manual 1/17 8/21/2014 1. Background Heat exchangers are ubiquitous in the industrial world with millions

More information

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,

More information

Experiment 3 Pipe Friction

Experiment 3 Pipe Friction EML 316L Experiment 3 Pipe Friction Laboratory Manual Mechanical and Materials Engineering Department College of Engineering FLORIDA INTERNATIONAL UNIVERSITY Nomenclature Symbol Description Unit A cross-sectional

More information

Using Excel to find Perimeter, Area & Volume

Using Excel to find Perimeter, Area & Volume Using Excel to find Perimeter, Area & Volume Level: LBS 4 V = lwh Goal: To become familiar with Microsoft Excel by entering formulas into a spreadsheet in order to calculate the perimeter, area and volume

More information

AN EXPERIMENTAL STUDY OF EXERGY IN A CORRUGATED PLATE HEAT EXCHANGER

AN EXPERIMENTAL STUDY OF EXERGY IN A CORRUGATED PLATE HEAT EXCHANGER International Journal of Mechanical Engineering and Technology (IJMET) Volume 6, Issue 11, Nov 2015, pp. 16-22, Article ID: IJMET_06_11_002 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=6&itype=11

More information

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger International Journal of Engineering Research and Technology. ISSN 0974-3154 Volume 6, Number 1 (2013), pp. 33-40 International Research Publication House http://www.irphouse.com Comparison of Heat Transfer

More information

Shell and Tube Heat Exchanger

Shell and Tube Heat Exchanger Sell and Tube Heat Excanger MECH595 Introduction to Heat Transfer Professor M. Zenouzi Prepared by: Andrew Demedeiros, Ryan Ferguson, Bradford Powers November 19, 2009 1 Abstract 2 Contents Discussion

More information

SA-9600 Surface Area Software Manual

SA-9600 Surface Area Software Manual SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The

More information

CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here Operating Instructions Table of Contents 1 INTRODUCTION Safety 2 Sample Preparation 3 2 BACKGROUND Background Information 4 Resources

More information

Heat Exchangers - Introduction

Heat Exchangers - Introduction Heat Exchangers - Introduction Concentric Pipe Heat Exchange T h1 T c1 T c2 T h1 Energy Balance on Cold Stream (differential) dq C = wc p C dt C = C C dt C Energy Balance on Hot Stream (differential) dq

More information

Only smart people read the manual.

Only smart people read the manual. Only smart people read the manual. Contents Getting Started... 1 Safely Turning Your Drive On and Off... 1 Disconnecting esata and 1394 Devices... 2 esata Devices... 2 1394 Devices... 3 Installing FreeAgent

More information

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C. Operator's Manual

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C. Operator's Manual Convection Ovens BX Classic Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C Operator's Manual Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425

More information

INSTALLATION INSTRUCTIONS BL-8704

INSTALLATION INSTRUCTIONS BL-8704 INSTALLATION INSTRUCTIONS BL-8704 EXPOSED BLACK LEVER THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1

More information

Quick Start Guide See Inside for Use and Safety Information

Quick Start Guide See Inside for Use and Safety Information 3 rd Generation Personal 3D Printer Quick Start Guide See Inside for Use and Safety Information The USB Mass Storage Device Contains the User Guide and Quick Start Guide in other Languages Congratulations

More information

Experiment # 3: Pipe Flow

Experiment # 3: Pipe Flow ME 05 Mechanical Engineering Lab Page ME 05 Mechanical Engineering Laboratory Spring Quarter 00 Experiment # 3: Pipe Flow Objectives: a) Calibrate a pressure transducer and two different flowmeters (paddlewheel

More information

INSTALLATION INSTRUCTIONS MK-8704

INSTALLATION INSTRUCTIONS MK-8704 INSTALLATION INSTRUCTIONS MK-8704 EXPOSED MACKINTOSH THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1

More information

Florida Atlantic University VPN Client Installation Guide

Florida Atlantic University VPN Client Installation Guide Florida Atlantic University VPN Client Installation Guide VPN Client Installation Guide Page 1 Cisco VPN Client Installation Guide Please read the instructions below to assist with the process of downloading,

More information

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are: Autoclave Safety Purpose: Sterilization refers to the complete killing of all living organisms, including spores. Common sterilization techniques include the application of wet heat, dry heat, chemicals,

More information

(S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26)

(S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26) Chem 367-2/ Physical Adsorption 63 PHYSICAL ADSORPTION (S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26) The sample used in this experiment needs to be conditioned for at least two hours before the experiment;

More information

Spreadsheets and Laboratory Data Analysis: Excel 2003 Version (Excel 2007 is only slightly different)

Spreadsheets and Laboratory Data Analysis: Excel 2003 Version (Excel 2007 is only slightly different) Spreadsheets and Laboratory Data Analysis: Excel 2003 Version (Excel 2007 is only slightly different) Spreadsheets are computer programs that allow the user to enter and manipulate numbers. They are capable

More information

Small Animal Respiratory Exchange Ratio (RER)

Small Animal Respiratory Exchange Ratio (RER) iworx Physiology Lab Experiment Experiment AMe-1 Small Animal Respiratory Exchange Ratio (RER) Note: The lab presented here is intended for evaluation purposes only. iworx users should refer to the User

More information

Quick Reference Guide

Quick Reference Guide Welcome to BT Business Total Broadband Quick Reference Guide Follow the steps in this Quick Reference Guide to set up and start using your new BT Business Total Broadband service. The CD will help you

More information

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

- Do not immerse cords, pump or any electrical wire or device in water or other liquid. TRANSFER PUMP INSTRUCTIONS FOR THE SUPER TRANSFER PUMP 1. Pump (water may be present in the pump and lines due to testing at factory) 2. Instructions. 3. Inlet thicker wall hose (1), outlet hose (1) 4.

More information

Network Camera. Quick Operation Guide V4.0.1

Network Camera. Quick Operation Guide V4.0.1 Network Camera Quick Operation Guide V4.0.1 Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to DS-2CD8253F-EI(Z),

More information

Dash 8Xe / Dash 8X Data Acquisition Recorder

Dash 8Xe / Dash 8X Data Acquisition Recorder 75 Dash 8Xe / Dash 8X Data Acquisition Recorder QUICK START GUIDE Supports Recorder System Software Version 2.0 1. INTRODUCTION 2. GETTING STARTED 3. HARDWARE OVERVIEW 4. MENUS & BUTTONS 5. USING THE DASH

More information

SAGEM F@st TM 1201/1241 V2

SAGEM F@st TM 1201/1241 V2 SAGEM F@st TM 1201/1241 V2 Quick Installation Guide 253156400-A_GIR 1201 V2 STD-gb.i1 1 14/10/2008 16:59:35 Contents 1 contents of the pack...2 2 connecting YOUR MODEM...3 2.1 Connecting your router...3

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES 191: Calibration and Standards in Measurement Richard Paton National Engineering Laboratory, Scotland, UK 1 General Principles 1 2 Gravimetric Calibration of Liquid meters 2 3 Volumetric Calibration of

More information

8 plumbing. plumbing. 2010 PulteGroup, Inc. All Rights Reserved.

8 plumbing. plumbing. 2010 PulteGroup, Inc. All Rights Reserved. 8 90 2010 PulteGroup, Inc. All Rights Reserved. drains All the water you use leaves the home through a drain. Maintaining drains prevents clogging, overflows, water damage, and other problems. care and

More information

High kw Electric Tankless Water Heater Troubleshooting Guide

High kw Electric Tankless Water Heater Troubleshooting Guide Technical Service Bulletin High kw Electric Tankless Water Heater Troubleshooting Guide Models: WH17, WH27, WH36 AE115, AE125, (FD108 and higher) DANGER: ELECTRIC SHOCK ELECTRICITY IS EXTREMELY DANGEROUS.

More information

Rexroth Hydraulic Pump A10VO Series User Manual

Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

User manual. Atec. 086L0130 Rev. 1 EN

User manual. Atec. 086L0130 Rev. 1 EN User manual Atec 086L0130 Rev. 1 EN Thermia Värme AB reserves the right to make changes to components and specifications without prior notice. 2010 Thermia Värme AB. The Swedish language is used for the

More information

Zebra GC420t User Guide VIF-NA-BG-125, V3.0

Zebra GC420t User Guide VIF-NA-BG-125, V3.0 VIF - Maintenance of computer systems infrastructure Zebra GC420t User Guide VIF-NA-BG-125, V3.0 IZUM, 2016 COBISS, COMARC, COBIB, COLIB, IZUM are registered trademarks owned by IZUM. CONTENTS 1 Introduction...

More information

Dash 18X / Dash 18 Data Acquisition Recorder

Dash 18X / Dash 18 Data Acquisition Recorder 75 Dash 18X / Dash 18 Data Acquisition Recorder QUICK START GUIDE Supports Recorder System Software Version 3.1 1. INTRODUCTION 2. GETTING STARTED 3. HARDWARE OVERVIEW 4. MENUS & BUTTONS 5. USING THE DASH

More information

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered

More information

User Manual. For more information visit www.caldigit.com

User Manual. For more information visit www.caldigit.com User Manual For more information visit www.caldigit.com Contents 1. Introduction 03 Package Contents 06 T3 Diagram 07 2. Using the T3 08 Connecting the T3 08 How to create a RAID 09 - Mac OS X 09 - Windows

More information

HEAT TRANSFER IM0245 3 LECTURE HOURS PER WEEK THERMODYNAMICS - IM0237 2014_1

HEAT TRANSFER IM0245 3 LECTURE HOURS PER WEEK THERMODYNAMICS - IM0237 2014_1 COURSE CODE INTENSITY PRE-REQUISITE CO-REQUISITE CREDITS ACTUALIZATION DATE HEAT TRANSFER IM05 LECTURE HOURS PER WEEK 8 HOURS CLASSROOM ON 6 WEEKS, HOURS LABORATORY, HOURS OF INDEPENDENT WORK THERMODYNAMICS

More information

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: 0974-4290 Vol.7, No.6, pp 2580-2587, 2014-2015

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: 0974-4290 Vol.7, No.6, pp 2580-2587, 2014-2015 International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: 0974-4290 Vol.7, No.6, pp 2580-2587, 2014-2015 Performance Analysis of Heat Transfer and Effectiveness on Laminar Flow with Effect of

More information

Installation Instructions 4508 4508S

Installation Instructions 4508 4508S SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect

More information

BOREHOLE SEALING IN A COAXIAL HEAT EXCHANGER BY BENTONITE TREATMENT

BOREHOLE SEALING IN A COAXIAL HEAT EXCHANGER BY BENTONITE TREATMENT BOREHOLE SEALING IN A COAXIAL HEAT EXCHANGER BY BENTONITE TREATMENT Frank.B.Cruickshanks, Olof Andersson, James Bardsley Climate Change Division, Meteorological Service of Canada, 45 Alderney Drive, Dartmouth,

More information

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of the blood 7 Procedure to test glucose 7 Procedure to

More information

www.the Floor Heating Warehouse.co.uk

www.the Floor Heating Warehouse.co.uk www.the Floor Heating Warehouse.co.uk Underfloor Heating Installation Guide (Grundfoss Pump System) General Overview: Our water based underfloor heating system can be installed by your own plumber or heating

More information

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens clean the fan intake filter replace the projection lamp replace the batteries in the remote control use the Kensington lock feature

More information

User manual. 086U6297 Rev. 9 EN

User manual. 086U6297 Rev. 9 EN User manual Atria Atria Duo Atria Duo Optimum Atria Optimum Comfort Diplomat Diplomat Duo Diplomat Duo Optimum Diplomat Duo Optimum G2 Diplomat Optimum Diplomat Optimum G2 086U6297 Rev. 9 EN Thermia Värme

More information

Introducing AUDIT- BUDDY

Introducing AUDIT- BUDDY Introducing AUDIT- BUDDY Monitoring Temperature and Humidity for Greater Data Center Efficiency 202 Worcester Street, Unit 5, North Grafton, MA 01536 www.purkaylabs.com info@purkaylabs.com 1.774.261.4444

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

OnDemand Version 1.7. Installation Manual and User s Guide. AST Technology. Sophienstrasse 4 32051 Herford Germany

OnDemand Version 1.7. Installation Manual and User s Guide. AST Technology. Sophienstrasse 4 32051 Herford Germany OnDemand Version 1.7 Installation Manual and User s Guide AST Technology Sophienstrasse 4 32051 Herford Germany Contents Overview of OnDemand Software... 1 System and Software Requirements... 1 CVe Monitor

More information

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems ViewPower User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...2 1.4. Features...2

More information

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents

More information

North Carolina State University Emergency Facilities Closure Checklist- Part I

North Carolina State University Emergency Facilities Closure Checklist- Part I North Carolina State University Emergency Facilities Closure Checklist- Part I Unplanned or spontaneous events often disrupt daily operations on campus. In the event that an incident may interrupt your

More information

Installing a Probe. Typical Installation

Installing a Probe. Typical Installation for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assembly

More information

THRUST CURVE LOGGER V-4.200

THRUST CURVE LOGGER V-4.200 THRUST CURVE LOGGER V-4.200 There are several items that must be addressed prior to actual firing of the motor for data acquisition. These will be required in the Propellant Characterization process: Weigh

More information

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay QUICK START GUIDE SG2 Client - Programming Software SG2 Series Programmable Logic Relay SG2 Client Programming Software T he SG2 Client software is the program editor for the SG2 Series Programmable Logic

More information

Computer Networks I Laboratory Exercise 1

Computer Networks I Laboratory Exercise 1 Computer Networks I Laboratory Exercise 1 The lab is divided into two parts where the first part is a basic PC network TCP/IP configuration and connection to the Internet. The second part is building a

More information

Measurement of Specific Heat Capacity Using Differential Scanning Calorimeter

Measurement of Specific Heat Capacity Using Differential Scanning Calorimeter INL/EXT-08-15056 Measurement of Specific Heat Capacity Using Differential Scanning Calorimeter J. E. Daw November 2008 The INL is a U.S. Department of Energy National Laboratory operated by Battelle Energy

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

Watts Pure Water Systems

Watts Pure Water Systems Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before

More information

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and

More information

Online Monitoring User Guide

Online Monitoring User Guide High Resolution Temperature Sensing Strip Online Monitoring User Guide 888.637.3282 www.nerdata.com Page 1 of 26 Contents The Aurora Online Monitoring System... 3 1. Creating an Account on the Aurora Online

More information

Kurz MODBUS Client User s Guide

Kurz MODBUS Client User s Guide Kurz MODBUS Client User s Guide Introduction The Kurz MODBUS Client program can be used to demonstrate how the Kurz MFTB and MFTA Series products can be used in a MODBUS protocol network. The program is

More information

Calibration of Glassware

Calibration of Glassware Calibration of Glassware Introduction Glassware is commonly calibrated using a liquid of known, specific density, and an analytical balance. The procedure is to determine the mass of liquid the glassware

More information

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the

More information

Vaporization of Liquid Nitrogen

Vaporization of Liquid Nitrogen Vaporization of Liquid Nitrogen Goals and Introduction As a system exchanges thermal energy with its surroundings, the temperature of the system will usually increase or decrease, depending on the direction

More information

GenStore Archive Cabinet

GenStore Archive Cabinet GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4

More information

Manual. Sealer Monitor Software. Version 0.10.7

Manual. Sealer Monitor Software. Version 0.10.7 Manual Sealer Monitor Software Version 0.10.7 Contents 1 Introduction & symbols 1 2 Installation 2 2.1 Requirements 2 2.2 Installation process 2 3 Menu & Tooblar 5 3.1 File menu 5 3.2 Print menu 6 3.3

More information

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED

More information

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V. 1234 Hach Hall 515-294-5805 www.cif.iastate.edu Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V. Location: Contact: 1240 Hach Hall Steve Veysey, 1234 Hach Hall Safety All researchers working

More information

How To Replace A Reverse Osmosis Water Tank

How To Replace A Reverse Osmosis Water Tank ALL MODELS REVERSE OSMOSIS WITH NONAIRGAP FAUCET 1. Read all instructions carefully before starting installation. 2. Find the cold water line beneath your sink. The cold water is typically on the right.

More information

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...

More information

EScribe. EScribe at a glance

EScribe. EScribe at a glance EScribe EScribe is a software package used to configure and modify the operation of your DNA 200. It requires a Windows PC and connects to your DNA 200 through the onboard USB port. EScribe at a glance

More information

ETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10

ETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10 Color Light Streams Large Laminar Installation Manual (CLSLL) Input Power: Total Power: 12V AC 5W 4008814 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15152-00 Rev E2 9.14

More information

Error Codes: 02F. Model: 110.44832 200 (110. = Whirlpool) S/N: CSP 1903874 Type: 199-AKP 705/WT. Sears Kenmore/Whirlpool Front Load Washer

Error Codes: 02F. Model: 110.44832 200 (110. = Whirlpool) S/N: CSP 1903874 Type: 199-AKP 705/WT. Sears Kenmore/Whirlpool Front Load Washer Sears Kenmore/Whirlpool Front Load Washer Error Codes: 02F dlf Model: 110.44832 200 (110. = Whirlpool) S/N: CSP 1903874 Type: 199-AKP 705/WT SOURCE: www.applicancepartspros.com WHIRLPOOL FAULT CODES Whirlpool

More information

LUNG VOLUMES AND CAPACITIES

LUNG VOLUMES AND CAPACITIES LUNG VOLUMES AND CAPACITIES STANDARDS 3.1.10A, 3.1.12A Identify the function of subsystems within a larger system; analyze and describe the function, interaction and relationship Westminster College among

More information

Model 288B Charge Plate Graphing Software Operators Guide

Model 288B Charge Plate Graphing Software Operators Guide Monroe Electronics, Inc. Model 288B Charge Plate Graphing Software Operators Guide P/N 0340175 288BGraph (80207) Software V2.01 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001 585-765-2254

More information

Bottom Loading Water Dispenser

Bottom Loading Water Dispenser Bottom Loading Water Dispenser Model # 601000 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING DISPENSER. SAVE THIS MANUAL FOR FUTURE

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences

More information

M-9424-463V Intake Manifold INSTALLATION INSTRUCTIONS

M-9424-463V Intake Manifold INSTALLATION INSTRUCTIONS Please visit www.fordracingparts.com for the most current instruction information!!! PLEASE READ ALL OF THE FOLLOWING INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION. AT ANY TIME YOU DO NOT UNDERSTAND THE

More information

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE Roulette, T., J. Roulette, and S. Pons. Results of ICARUS 9 Experiments Run at IMRA Europe. in Sixth International Conference on Cold Fusion, Progress in New Hydrogen Energy. 1996. Lake Toya, Hokkaido,

More information