Uninterruptible Power Supply (UPS) Rating : 60 kva to 500 kva

Similar documents
DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Phase Modular Finally the benefits of Modular ups are for all

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

PowerGem Pro Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

RIELLO ELETTRONICA. Master HP

Thyristor-controlled power supplies and battery chargers

MAJORSINE Power Inverter

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

The UPS for the highest security in industry and data centres

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

LAP ENERGIA PARA DATACENTERS

Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

User Manual 1K/2K/3K Online UPS

TOSHIBA G /100/160/225 kva

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Uninterruptible Power Supply

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

User s Manual Before using the inverter, you need to read and save the safety instructions.

4.0 UPS dedicated to ICT for unmatched energy savings

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

UNINTERRUPTIBLE POWER SUPPLY (UPS)

Eaton 93PM UPS Where aesthetics meet intelligence.

Diesel Generating Set

Technical Data. back-up time in minutes 100% load % load

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Model #: SMART2200CRMXL

Uninterruptible power supplies Meissner. Efficient and reliable backup where electricity is critical to you

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Photovoltaic Solar Energy Unit EESFB

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

USER MANUAL Online UPS 1K/2K/3K

NC-12 Modbus Application

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Stroom voor elke toepassing

Specifying a Variable Frequency Drive s

Technical data UNIBLOCK UBSF

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

USER MANUAL Online UPS 1K/2K/3K Rack

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

Hitachi DATA Center UPS

Specification Requirements DBL 700MX and 1000MX Series UPS

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Online UPS. PowerWalker VFI 1000R/1U

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Liebert NXC from 10 to 200 kva

Schneider Electric GALAXY VM Data Center Grade Three Phase Uninterruptible Power Supply Guide Specifications kva UPS

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Galaxy VM. Three-phase power protection. schneider-electric.com

Frequency Converter Fv

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Assembled in Florida, USA.

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

Power Quality. Uninterruptible Power Supply

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Considering the effects of UPS operation with leading power factor loads

Transcription:

Uninterruptible Power Supply (UPS) Rating : 60 kva to 500 kva Y 7 - T CO - 24 365 LITY AGI VAILAB - A ILI T Supports your critical load with advanced technologies & features Reduced Energy Consumption & ultimately Cost Capacity enhancement Highly Efficient IGBT based Inverter Microprocessor based Digital Control Hitachi Australia Pty. Ltd.

Rating 60 kva 80 kva 100 kva 120 kva Applications 160 kva 200 kva 250 kva 300 kva 400 kva 500 kva It serves various applications in key industries like Processes Industries i.e. Plastic, Textile, Cable, Rubber, Glass, Paper, etc., Data centre, Telecom, Network Medical & Healthcare, Laboratories, Automobile, Transportation i.e. Rail, Airports, Shipping, Highways, Tunnels and many others. Conveyors Extruders Winders Injection Moulding Mixers Crushers Wire Drawing Elevators Hoists Rotary Kiln Glass Multi Protection & Green Power Design Medical Equipment And many others... Multi Protection OVP - Over Voltage Protection OCP - Over Current Protection OTP - Over Temperature Protection SCP - Short Circuit Protection QUALITY 100% Green Power Green design converse more energy and induces lower power loss >0.99 Input PF Eco Mode Input current THD < 3% www.hitachi-hirel.com www.hitachi.com.au 02

Unit Parallel Connection Concept Advanced Technologies & Features Add as you need without taking a shutdown Multiple UPS units can be added to enhance the UPS rating or achieve a parallel configuration even while the base units are running. No shutdown will not only ensure continuity of your critical operations but will also ensure peace of mind with clean continuous power to all your sensitive equipment. Up to 8 UPS Systems can be configured as a parallel redundant system Option to expand UPS units for future expansion at marginal cost and smaller dimensions N+1 redundancy can be achieved without external system bypass switch Install additional units or maintain an existing unit without affecting the load Configure a highly robust and reliable system with dual input/output Technologies & Features Compact, Light-weight And High Efficiency Design Up to 8 Hitachi UPS Systems can be configured as a parallel redundant system. A smaller installation foot-print means a larger space available for the customer's system. Lower power loss means lower electricity cost and a smaller capacity required of the air-conditioning equipment. The 415 V UPS input/output allows for larger capacity feeding with low power losses. Advanced circuit technology and the high speed IGBT switching technology eliminate the need for an inverter transformer, directly saves valuable installation space as well as reducing substantial weight of the system. This enables the compact light weight system for quick positioning on site. Long Life Parts Frequent replacement of components is costly and recurring in terms of cost of the parts as well as charges payable to the personnel for the job. It will also call for a system shutdown lead to a major loss. e Our i6 system is built with long life parts; contribute to substantial reduction in maintenance costs. e i6 Uninterruptible Power Supply (UPS) 03

Advanced Features Requirements UPS Advanced Features Power saving feature High efficiency Reduced footprint Small footprint Light weight design Transformer less Inverter 415V input / output Economical Nominal initial cost Low running expenses Lower maintenance cost Short lead-time delivery Minimum parts replacement Components sourced from globally established vendors Long life fans and capacitors Reduced installation cost System menu setting Ready for on floor installation Standard specifications engineered Utilization of floor wiring Expandability Expansion without power interruption to the load Expansion of UPS as load capacity increase Unit parallel connection design Configure parallel redundant system without external bypass switch Dual input / output system Maintainability Easy operation of UPS Area-free monitoring Operational status, Operation guidance, Trend information, Measurement etc. Support the on line maintenance LCD panel PFC for alarms Supply of high-quality power Sine Wave output 150% overload capacity IGBT inverter Guard against the full spectrum of power disturbances On line double conversion Innovation New Technologies Reduce the effects for input power Low input current harmonics High input power factor IGBT converter Reduce the effects on the back up generator Input current walk in Reliability Stable Power Supply Back-up system availability Parallel redundant system Fully automatic transfer / re-transfer switch N+1 redundancy www.hitachi.com.au www.hitachi-hirel.com 04

Technical Specifications Perameter Specifications Supports Your Critical Load With Advanced Technologies & Features AC Input DC Bus Voltage Output Performance Ambient conditions Enclosure Voltage (specified) Voltage operational Rated frequency Frequency range Input power factor Input current THD** Voltage range Maximum DC bus ripple Rated voltage Voltage regulation - steady state Rated load power factor Transient response 100% step load Recovery time up to 98% Voltage distortion Internal oscillator accuracy (free run) Frequency synchronization range Overload Overall efficiency Linear load Nonlinear load Phase angle accuracy with 100% unbalance load Ambient temperature Relative humidity Audible noise Atmosphere Altitude Protection Class Construction Finish (Powder Coated) Ventilation Cable Entry 415V (+) 10% & (-) 10% three phase four wire 415V (+) 10% & (-) 40% three phase four wire 50Hz / 60Hz ± 6% 0.99 < 3% 396 V (cut off) min to 700 V (boost) max < 1% RMS 415 V three phase four wire ± 1% 0.9 Load crest factor 3 : 1 ± 5% < 1 cycle < 2% < 5% 0.1% ± 6% 110% for 60 minutes 125% for 600 seconds 150% for 60 seconds < 3 degree Up > = to 95% Eco Mode efficiency 98% 0-40 C 90% non condensing <65 db A (60/80 KVA ), < 72 db A (100-200 KVA), <75 db A ( > 200 KVA ) Non corrosive, Dust free, Freely ventilated 1000 meters from MSL CRCA steel sheet IP 20 ( Optional IP31, IP41, IP42, IP43 ) RAL 7035 (Other colours optional) Forced air (Internal fans) Bottom (Top optional) Standards IEC 62040-1,2 & 3 ** @ 100% rated load and nominal input voltage, with input voltage THD <1% e i6 Uninterruptible Power Supply (UPS) 05

Dimensions Rating (kva) Height (mm) Width (mm) Depth (mm) Weight (kgs) 60 1800 700 800 270 80 1800 700 800 300 100 1800 900 900 380 120 1800 900 900 380 160 1900 1300 900 495 200 1900 1300 900 590 250 1900 1300 900 940 300 1900 2100 900 1000 400 1900 2100 900 1160 500 1900 2100 900 1300 Note : Dimensions & weights are subjects to change. Block Diagram MBS 415V 3Ph/4Wire Bypass Static Switch 415V 3Ph/4Wire Mains PWM Rectifier PWM Inverter Static Switch Load Charger- Booster Battery Options Parallel or Hot standby redundancy Input isolation transformer Output isolation transformer Bypass line regulator AC distribution panel PC based monitoring & recording unit RS - 485 communication port Monitoring on LAN through SNMP & Profibus Remote annunciator Automatic shutdown kit DCS connectivity through Modbus Individual Battery Health Monitoring Systems (BHMS) Emergency alerts via SMS Suitable for regenerative loads Back feed protection www.hitachi-hirel.com www.hitachi.com.au 06

Pan India & Global Presence USA Middle East Africa India South East Asia Hitachi Australia Pty. Ltd. Suite 801, Level 8, 123, Epping Road, North Ryde NSW 2113 Phone: +61 2 9888 4100 Fax: +61 2 9888 4188 Web: www.hitachi.com.au In the spirit of continuous improvement, specifications are subject to change without notice. i6 Export / 02 / 15 / Ver.1 / Corp. Mktg / India l Spotlight - 079 3002 2324 Australia