Phoenix MultiPlus. Multi-functional inverter / battery charger with intelligent mains and generator power management

Similar documents
Phoenix MultiPlus. Multi-functional inverter / battery charger with intelligent shore and generator power management

Stroom voor elke toepassing

Achieving the impossible

ESP PANELS TM & SYSTEM COMPONENTS. Instruction and connection manual

ENERGY. ANYTIME. ANYWHERE. AUTOMOTIVE

Connecting your Victron product to a computer with VE Configure

ENERGY. ANYTIME. ANYWHERE. MARINE

Phoenix Multi 120Vac 12/1600/70 12/2500/120 24/1600/40 24/3000/70. Phoenix MultiPlus 120Vac 12/2500/120 24/3000/70

Using the Phoenix MultiPlus

Manual. Solar Fountain Mobile Phone Charger

Manual. VE.Bus to NMEA 2000 interface

Off-grid, back-up & island systems. Energy. Anytime. Anywhere.

OFF-GRID BACK-UP & ISLAND SYSTEMS

Off-grid, back-up & island systems. Energy. Anytime. Anywhere.

INSTALLATION & SERVICE MANUAL. Display Panel

Thyristor-controlled power supplies and battery chargers

Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG

Copyrights 2010 Victron Energy B.V. All Rights Reserved

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

User Manual for CH-PFC76810

Your own power station: For continuous power

Number 1 in efficiency

OUTPUT CABLE CONNECTIONS:

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

WHOLESALE DIRECT INC WEST 65TH STREET

Photovoltaic Solar Energy Unit EESFB

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

SYSTEM 4C. C R H Electronics Design

GSM ATT Modules Simply effective remote control

The most comfortable air-conditioning systems for yachts and superyachts

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5

Electrical System From The Top Down By Rick Denney, GMC Eastern States April 2006

EC450 Power Control System

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

Diesel Generating Set

MPR-Systems. Mini Power Racks 1200 W W

Inverter / Charger Installation General Operations and AC and DC Connections

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

MAJORSINE Power Inverter

ST Series POWER SUPPLIES USER INSTRUCTIONS

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

SYSTEM 45. C R H Electronics Design

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

BITMAIN. APW PSU Series User Guide

FIREDEX Conventional Fire Panels

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

SNMP Web Management. User s Manual For SNMP Web Card/Box

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

Off-grid solar and backup power installations

Multi-Range Programmable DC Power Supplies 9115 Series

DCS Series 1 kw, 1.2 kw, & 3 kw

4.0 UPS dedicated to ICT for unmatched energy savings

DC Electronic Loads 8500 series

1.44 kw Programmable DC Power Supplies XLN Series

User s Manual Before using the inverter, you need to read and save the safety instructions.

NC-12 Modbus Application

victron energy USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG Phoenix 12/220 Phoenix 24/220 Phoenix 48/220

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Industrial Batteries / Motive Power Chargers 2100.NET.»For improved efficiency and durability«

Model #: SMART2200CRMXL

User Manual HomeGrid 3000 Solar Generator

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

40.3. Control Relays and Timers

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

POWER PORTABLE GENERATORS POWER. WHEN YOU NEED IT.

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

RADIANT PLASMA 4700 Plasma Spark Generator

Installation and Operation Back-UPS 1250, 1300, 1500

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.


UPS Applications and VRLA Battery Sizing

PowerGem Pro Uninterruptible Power Supply

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Voltech DC1000. Precision DC Bias Current Source

HYBRID POWER SYSTEMS for TELECOM applications

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

12 Volt 30 Amp Digital Solar Charge Controller

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Specifying a Variable Frequency Drive s

Centro-Matic Automatic Lubrication Systems System Controls

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Product Information Sheet UH28CS-12kV Hi Pot Tester

Phase Modular Finally the benefits of Modular ups are for all

THE SOLAR TRANSFORMER. Portable Integrated Solar Power

BB800 Off-Grid Solar System

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Transcription:

Phoenix MultiPlus Multi-functional inverter / battery charger with intelligent mains and generator power management

Phoenix MultiPlus Explained Multi function with intelligent mains and generator power management Multi phase capability The MultiPlus gets its name from the multiple functions it will perform. It is a powerful sinewave inverter, a sophisticated battery charger that features adaptive charge technology and a high speed power transfer switch; all in a tough, compact enclosure. The MultiPlus is much more than this, however, and it s many advanced, even unique, functions open a whole new spectrum of applications. Powerful sinewave inverter As an inverter MultiPlus delivers high quality pure sinewave power for trouble free operation of all appliances. The high peak capacity also delivers double the rated output as starting power. Uninterrupted AC Power (UPS function) Switching from inverter to mains or generator and back is automatic and so fast (within 20 milliseconds) that computers and other connected equipment are unaffected and continue to operate as normal. In addition to parallel operation, multiple units can be connected together to provide three-phase power. For US compatible applications, units can be connected for split phase configuration. And of course, multi phase sets can be connected in parallel too! Four stage adaptive charger and dual battery charging There are two charge outputs in each MultiPlus. The main output benefits from a true 4-step adaptive charge characteristic that fine tunes every charge cycle to deliver exactly what the battery needs each time. No more, no less. The fourth and final stage of the charge process, battery storage mode, keeps all the batteries in perfect condition over long periods of inactivity. Battery temperature and voltage sensing are also standard features. Altogether, this adds up to keeping your battery in prefect condition. The second charge output is float-only and intended specifically for an engine start battery. Virtually unlimited power thanks to parallel connection To achieve high power solutions, several MultiPlus can be connected together for increased inverter and charger output. For example, four MultiPlus 24/3000/70 models will provide an output of 52A at 230V (and double that for a few seconds to start loads such as air-conditioning) and 280A of battery charging. Connection in this mode is straight-forward using a simple plug-in data cable.

PowerControl PowerAssist Dealing with limited generator or mains side/grid power Boosting the power available from mains or generator, an innovative feature of MultiPlus. All models in the MultiPlus range feature powerful battery chargers. When the largest model is working hard it can draw almost 10A from a 230V supply. Using the remote panel it is possible to dial-in the maximum current that is available from mains or generator. The MultiPlus will then automatically regulate the charger taking account of other AC loads and ensuring the charger only uses what is spare. This way it is possible to avoid tripping the mains power or overloading the generator. The feature that most distinguishes the MultiPlus from other inverter / chargers is PowerAssist. This feature takes the principle of PowerControl to a further dimension by allowing a MultiPlus to supplement the power available from mains or generator to assist during periods of high demand. Peak power demand is almost always sustained only for short periods, either a few minutes (in the case of items like cooking appliances) or just a few seconds (in the case of the burst of energy needed to start an air-conditioning or refrigeration compressor). With the capacity of the generator or mains power set on the remote panel, the MultiPlus detects when the load is becoming too much for the supply and will instantly provide the extra power required. When the demand has reduced, the unit returns to charging the battery. This feature is equally effective in large and small systems helping to reduce the required generator capacity or to achieve greater things with limited mains power. There is even a special feature to enable the MultiPlus to work perfectly with portable generators. Energy Unlimited With the features of parallel connection and PowerAssist what can be achieved is truly amazing. All the possibilities for optimising the use of energy resources are explored in the book Energy Unlimited that is free to download at www.victronenergy.com or can be sent to you free of charge on request. The book provides details about effective battery management, how to apply the MultiPlus in different circumstances and much more practical advice on power systems in general.

mains on bulk absorption float inverter on overload low battery temperature Typical Installation A Mains power B Phoenix Multi remote panel C Phoenix MuliPlus D RCB E Load shedding relay B PHOENIX MULTI CONTROL inverter on mains on 16 12 20 overload boost 8 24 C AC distribution low battery equalize 4 28 temperature float on charger only off 0 30 shore current limiter charger inverter E Water Heater (10A) Microwave (6A) phoenix multi plus 12/3000/120 Fridge (1A) www.victronenergy.com A D TV / DVD (1A) Computer (1A) Kettle (13A) Hairdryer (10A) Power Tools (2A) Battery 12V/300Ahr Services Battery 12V/80Ahr Starter

How it works in practice Typical Installation Away from mainspower Endless possibilities The example to the left shows a typical installation, where the operator wants the convenience of mains power available at all times. When you connect your vehicle to mains power (A). The mains power supplies the MultiPlus (C). The MultiPlus checks that the power is of a suitable voltage and frequency and then feeds the mains power to the circuits and uses mains power to charge the batteries. Power Control Mains power is often available at a limited amperage. The optional remote panel (B) allows the user to inform the MultiPlus of the mains power limit, the MultiPlus will then control the charging output to work within the limits of the mains. As more power is used for circuits the charger output automatically reduces to avoid overload. When the vehicle is disconnected from mains power, the MultiPlus reacts instantly and continues to supply AC power to the circuits using the inverter function. Non inverter circuits Not all appliances are appropriate for running from the inverter when there is no mains power because of the draining effect they would have upon the battery. These items can be on a circuit that is fed via a load shedding relay (D). All MultiPlus models can be programmed to operate such a relay and the EasyPlus even has the device built in. This is another innovative feature of the MultiPlus product range. The working example described relates, of course, to a vehicle but you will find the MultiPlus is put to work the world over in a hugely diverse spectrum of applications. From power in sailing yachts on the oceans and game lodges on safari to providing essential power back up for traffic management systems or supplying medical equipment in ambulances. Some of the more typical applications are highlighted below: Specialist vehicles & motor homes Emergency vehicles Sailing yachts, motorboats and commercial craft Emergency and back up power Telecommunications & telemetry power supply Remote buildings Medical, military and scientific Alternative energy systems Power Assist With a MultiPlus, power management goes one step further. In the event that the loads exceed the available mains power, the inverter function works in parallel with the mains connection to boost the total energy available and avoid overload. This works just the same with a generator. MultiPlus Compact The MultiPlus is available in standard and compact format. The compact model is available up to 1600VA and shares all of the same features as the standard version except that it is supplied in a smaller enclosure. The compact versions also benefit from having battery cables supplied and plug-in connections for mains power in and out so installation is as straight forward as can be, straight out of the box.

www.victronenergy.com www.victronenergy.com Power control Battery charger reduces its output, if required, to avoid overload of supply when consumption is high. Multi remote panel MultiPlus B PHOENIX MULTI CONTROL inverter on mains on 16 12 20 overload boost 8 24 C AC distribution low battery equalize 4 28 A Mains Power temperature float 0 30 on charger only shore current limiter off 16A phoenix multi plus 12/3000/120 RCD D Water Heater (10A) Microwave (6A) Fridge (1A) TV / DVD (1A) Computer (1A) Kettle (13A) Battery 12V/300Ahr Services Reduced charge to battery 13A Hairdryer (10A) Power Tools (2A) Power Assist Inverter boosts mains power, if required, to avoid overload of supply when consumption exceeds supply. Multi remote panel MultiPlus B PHOENIX MULTI CONTROL inverter on mains on 16 12 20 overload boost 8 24 C AC distribution low battery equalize 4 28 A Mains Power temperature float 0 30 on charger only shore current limiter off 16A phoenix multi plus 12/3000/120 RCD D Water Heater (10A) Microwave (6A) Fridge (1A) TV / DVD (1A) Computer (1A) Battery 12V/300Ahr Services 21A Battery delivers energy to Power Assist shore power Kettle (13A) Hairdryer (10A) Power Tools (2A)

Phoenix EasyPlus Accessories For the more straightforward applications we have taken the everything in one box concept to it s ultimate end in the form of the EasyPlus. This model has everything you get from a MultiPlus with the addition of an inbuilt RCD and MCB s for AC power distribution. So you no longer need a separate circuit breaker panel. With battery cables fitted and the AC connections being plug-in (as for all compact models) installation could not be any easier! The EasyPlus truly is a complete power system in one box. A range of accessory items are available to enhance the function of your MultiPlus. Remote control panels The Phoenix Multi Remote Panel provides control and indication of the unit at a remote point and connects, using a network patch lead, to the unit. As an alternative, remote control is available through the VE.Net panel that can also be used to display battery information and even control your generator. Phoenix Duo Multi Control Panel This clever remote panel allows you to set 2 different AC power limits, one for mains power and one for the generator. Parallel & multi-phase connection kits Cable kits are available for connection of units in parallel or for configuring systems in multi phase format. VE configure set-up software To enable fine tuning of your MultiPlus, VE configure software is available that provides the means to easily adjust parameters and control specific features such as manipulating the battery charge characteristics or for working with certain portable generators. This powerful tool is not for everyone, however, so discuss with your distributor how best to make use of this facility. Battery monitoring The BMV 600 is an ideal means of monitoring the state of charge of your battery. It will provide voltage, current and capacity information and much more besides. An equally effective means of obtaining this information is with the VE.Net monitoring module linked to the VE.Net panel (mentioned previously).

B+ Indicatie led Indicatie led Indicatie led Hier staat in verschillende talen wat de functie van de blauwe kast is Hier staat in verschillende talen wat de functie van de blauwe kast is Hier staat in verschillende talen wat de functie van de blauwe kast is Hier staat in verschillende talen wat de functie van de blauwe kast is Typical system with MultiPlus Compact and mains power MultiPlus Compact Multi remote Panel BMV-600 Battery Monitor PHOENIX MULTI CONTROL inverter on mains on 16 12 20 overload boost 8 24 low battery equalize 4 28 AC distribution temperature float 0 30 on charger only off shore current limiter Load shedding relay Water Heater (10A) Microwave (6A) phoenix Multicompact 12/1200/50 Fridge (1A) TV / DVD (1A) RCD Computer (1A) Kettle (13A) Mains Power Hairdryer (10A) Power Tools (2A) Alternator Cyrix battery separator DC board DC distribution Start Voltage sense Internal Lights Temp Sense Water Pump Engine Accessory Accessories

Programmable, Adaptive 4-stage Battery Charging The ultimate battery charger As a battery charger, the MultiPlus offers the ultimate in programmable sophistication. The four stage adaptive charge characteristic, unique to Victron Energy, ensures that each and every charge cycle delivers exactly what the battery needs. Using VE configure set up software it is possible to modify charge characteristic and parameters to suit any type or size of battery. power being used, the MultiPlus assumes the system is in storage. This is a very low charge level that prevents the battery from discharge whilst minimizing the risk of gas being produced. Periodically, the charger will provide a short boost charge to keep the battery in perfect condition regardless of how long the system is left in storage. Battery safe Adaptive 4-stage charging The MultiPlus identifies how much energy remains in the battery at the beginning of each cycle. The charge parameters are then adapted to deliver exactly what is needed; no more and no less. This process ensures fast and complete charging without causing damage through overcharging. Properly charged batteries will last much longer as well as giving you more useable energy. Battery storage/reduced float The fourth and final stage in the charge cycle is termed battery storage or reduced float. When the battery is full and no At the point at which the charger reaches maximum power output, the greatest risk of overcharging exists. Battery safe mode is a special feature that checks the increase in power to prevent overcharge. Perfect for every battery type Using VE configure software, a MultiPlus can be tuned to suit any type or size of battery. Either by choosing from a selection of most common pre-set battery types or by making custom adjustments it is possible to set the Multi s charge profile exactly as you want. Bulk mode maximum power delivery for rapid charging Battery safe rapid charge is checked to prevent over charging Absorption mode accumulated charge is absorbed into the plates Float mode the remaining charge is gently applied until the battery is full Storage mode after an extended period of inactivity, storage mode is initiated Other standard features The Battery temperature sensor enables the Multi to account for changes in temperature that affect the characteristics of the battery. Remote voltage sensing compensates for any losses in the connection to the battery. An auxiliary 4 Amp output is provided and ideal for maintaining an engine battery.

www.victronenergy.com www.victronenergy.com DC/AC system 2xMultiplus & 6kVA AC genset with VE.Net Max 11kVA VE.Net panel 2 x MultiPlus VE.NET Battery 1 status 13.25V +5A 78% AC distribution back enter phoenix multi plus 12/3000/120 phoenix multi plus 12/3000/120 Load shedding relay Water Heater (10A) Microwave (6A) Fridge (1A) TV / DVD (1A) PowerMan Gen/Shore transfer Computer (1A) Coffee Maker (13A) Mains Power (16A) Generator relay unit Multi VE.Net Interface Hairdryer (10A) Washer/dryer (13A) Air - Con (Partial) Induction Hob VE.NET Generator module VE.NET Battery Controller Alternator Cyrix battery separator DC Link Box DC distribution Internal Lights Genset 230V/50Hz 6kVA Start Water Pump Engine Accessory Accessories

Total Power Management The way that 230V power is used is irregular; sudden bursts of very high demand (such as when the air-con kicks in), short periods of substantial power use (such as when the washing machine or oven is on) and then long periods when very little power is being used. As more and more equipment is used on vehicles, these irregular characteristics become more difficult to contend with. High peak power One way that the MultiPlus is particularly good at dealing with these conditions is that it can deliver more than double rated output to deal with those sudden bursts in demand. The rugged inverter technology means that such performance is delivered without paying a penalty in weight or dimensions. Power assist Parallel connection The larger models in the MultiPlus range can be connected together to increase the total power available. When this feature is combined with those mentioned above great things can be achieved with dramatic reductions in generator size and the ability to be free of the restriction of limited mains power. Now you can use power on the move in the same way you do at home without thinking about it! The chart below illustrates how power might be typically used in larger vehicle applications showing the peaks in demand and the average power consumption. In this case, what would have been a 10kVA generator is replaced by a 6kVA set. The Power Assist feature of the MultiPlus 24/3000/70 is available to deal with the peak loads and batteries are charged when spare power is available. When power demand is low the generator is not needed at all and the MultiPlus silently delivers the power that is needed. VE.Net - total power management For the ultimate in monitoring and control of your power system, VE.Net represents the state of the art. As a truly integrated solution, VE.Net provides the following components: VE.Net panel - multi character display and interface panel Battery Controller - full function battery monitoring module (any number can be connected to network). Generator control - full monitoring and control of your generator including auto start/stop functionality. Connectivity module - enables full access to system status and control remotely through the internet. This module also provides fully detailed geographical positioning. The ability to temporarily supplement the power available from mains or generator is another way the MultiPlus can help manage power needs. By adding power, far more can be achieved with connection to limited capacity mains supply. Equally, there is no longer a need to oversize a generator just so that it can deal with the peak power demanded by an air-con at start up. VE.Net can also be integrated with any number of other devices including a PC, power distribution systems and / or senders and alarms. Your imagination is the only limit to what is possible.

Phoenix MultiPlus 12 Volt C12/800/35 C12/1200/50 C12/1600/70 C12/2000/80 12/3000/120 Phoenix EasyPlus 12 Volt C12/1600/70 Phoenix MultiPlus 24 Volt C24/800/16 C24/1200/25 C24/1600/40 24/2000/50 24/3000/70 Phoenix MultiPlus 48 Volt 48/3000/35 Victron Energy B.V. / De Paal 35 1351 JG Almere / The Netherlands Phone: +31 (0)36 535 97 00 Fax: +31 (0)36 535 97 40 e-mail: sales@victronenergy.com www.victronenergy.com PowerControl yes yes yes yes yes yes PowerAssist no yes yes yes yes yes INVERTER Input voltage range (v DC) 9,5-17volts 19-33volts 38-66volts Output output voltage 230 VAC+/-2% frequency 50Hz +/-0.1% Cont. output power@25 c (VA) 800 1200 1600 1600 2000 3000/3000/3000 Cont output power@25 c (W) 700 1000 1300 1300 1600 2500/2500/2500 Cont output power@40 c (W) 650 900 1200 1200 1450 2000/2000/2000 Peak power (W) 1600 2400 3000 3000 4000 6000/6000/6000 Maximum efficiency (%) 92/94 93/94 93/94 93 93/94 93/94/95 Zero-load power (W) 4,5/6,0 4,5/6,0 4,5/6,0 4,5 4,5/6,0 4,5/6,0/7,0 CHARGER AC Input Input voltage range 187-265 v AC Input frequency 45-55Hz Power Factor: 1 Charge voltage absorption (v DC) 14,4 / 28,8 / 57,6 (can be progammed for custom requirements) Charge voltage float (v DC) 13,8 / 27,6 / 55,2 (can be programmed for custom requirements) Storage mode (v DC) 13,2 / 26,4 / 52,8 (can be programmed for custom requirements) Charge current house battery (A) 35 / 16 50 / 25 70 / 40 70 80 / 50 120 / 70 / 40 Charge current starter battery (A) 4 Battery temperature sensor yes GENERAL Transfer relay capacity 16 A 16 A 16 A 16 A 30 A 16 A (30A option) Multi purpose relay driver or relay relay driver relay driver relay driver relay driver relay relay Protection a,b,c,d,f,g,h a - h Common Characteristics Operating temp. range: 0-50 c (fan assisted cooling). Humidity (non condensing): max 95% ENCLOSURE Common Characteristics Material and colour: aluminium (blue RAL5012) Protection category: IP21 Battery-connection Battery cables of 1.5 meter M8 studs 230 v AC-connection G-ST18i connector screw-clamp 2.5mm Weight (kg) 8 10 10 12 12 18 Dimensions (hxwxd in mm) 375 x 214 x 110mm 510 x 214 x 110 520 x 255 x 125 362 x 258 x 218 STANDARDS Safety EN 6035-1, EN 60335-2-29 Emission / Immunity EN55014-1, EN 61000-3-2 / EN 55014-2, EN 61000-3-3 Automotive Directive 95/54EC SAL064160020- (10/07) Protection key: a) output short circuit b) overload c) battery voltage to high d) battery voltage to low e) battery reverse polarity detection f) 230 v AC on inverter output g) input voltage ripple too high h) temperature to high