user guide issue

Similar documents
FIRERAY 2000 Installation Guide

now faster and boasting many new useful features this is by far the best beam on the market

FIREDEX Conventional Fire Panels

Drayton Digistat +2RF/+3RF

Laserlyte-Flex Alignment System

Digital Keypad Use s Manual

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

EBDSPIR-PRM, EBDSPIR-PRM-IP

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

Awning Instructions. Full Cassette 1.5m to 6m

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

E-PDD Duct Smoke Detector Installation Sheet

Installation handbook. AutroBeam 25 Beam detector


Installation Instructions

GSM Autodialer Professional GJD700 Speech & Text Autodialer

How To Use A Ds340 (Dsp)

GST301. (Single Protection Zone) Operation Manual

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions

INFRARED QUARTZ WALL HEATER

Repeaters and Mimics Data Sheet

INSTALLATION MANUAL XM3 Reader

ATL Fuel Level Sender Probes

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Beam Detection Systems Application Guide

PUSH BUTTON START INSTALLATION MANUAL

12 Volt 30 Amp Digital Solar Charge Controller

Wireless Home Security Alarm System AM 500

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

Secure Keypads for access control

Operating Instructions. Room temperature controller

Business/Home GSM Alarm System. Installation and User Manual

Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app

K17.12 Door closers K17. Doors

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

User Installation Guide

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Triple Waveband Infra-Red Flame Detection

REDWALL-V adjustment procedures guide

9452/9453 Installation and User Guide

Single Channel Loop Detector

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Passive Infrared Motion Detector 5420/90. Installation Instructions

for DNE-K07 Reference and Installation Manual

SELECTION, APPLICATION AND MAINTENANCE

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

FAAST. Fire Alarm Aspiration Sensing Technology

4.3-inch Back-Up Camera

Wireless Alarm system s manual

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

COLOR TFT LCD MONITOR. User Manual

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

Instruction Manual. This Manual covers the use of: SmartSwitch Servo Kit. DCC Stationary Decoder PLEASE READ THESE INSTRUCTIONS FULLY BEFORE USE

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

VARIO PROX CARD READER INSTALLATION MANUAL

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

WD-AMX Water Detection Controllers

Manual for Fire Suppression & Methane Detection System

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Hygro-Thermometer + InfraRed Thermometer Model RH101

TS510 & TS500. Installation & User Guide. Compatible Equipment

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Product Specification instalert Rapid Messenger Variable Message Sign

Installation Guide for Hive Active Heating

GERONIMO ANALOGUE HEAVY DUTY TELEPHONE

5W LED Energy Saver PIR Bulkhead

High Performance Visible Laser Diode Scanners

DC-8706K Auto Dial Alarm System

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

POINTS POSITION INDICATOR PPI4

Fire. The Fire Installers Mate. A guide to fire alarm systems design

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Welcome to John Lewis Broadband

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

4-Channel Thermometer / Datalogger

Motion Activated Camera User Manual

GSM Alarm System User Manual

2013 Wireless Video Intercom INSTALLATION GUIDE

FG MOISTURE MONITOR Installation & Operation Manual

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

PYRODIGITAL CONSULTANTS PD Firing Module Continuity Reader

Duct Humidity Transmitter

Transcription:

user guide issue 0025-05

distance & positioning guidelines these guidelines are given as a guide only and it is important that you refer to your appropriate governing standards at all times. what distance? The standard fire beam will be suitable for distances of over 5m to 40m to the reflector.if you require 40m to 80m you will need to use the mid range reflector extension kit. For ranges of 80m t0 100m you will require the long range reflector kit. 5m 40m 80m 100m standard 5-40m beam standard beam+40-80m reflector kit standard beam+80-100m reflector kit 5-40 metres the standard firebeam The standard firebeam comes boxed with the head unit, low level controller, one reflector, 3mm allen key, test filter and quick start installation guide this should be used for distances over 5m and up to 40 meters 5-40 metres 40-80 metres = the standard firebeam + mid range 40 to 80m kit for distances 0f 40 metres to 80 meters you will need to use the standard firebeam and a mid range extension kit (the mid range kit comes with a backing plate and 3 extra reflectors, you will need to add the reflector from the standard kit to the mid range kit with the screws provided) 40-80 metres add the reflector from the standard firebeam to the mid range kit with the screws provided 2

80-100 metres = the standard firebeam + long range 80 to 100m kit for distances 0f 80 metres to 100 metres you will need to use the standard firebeam and a long range extension kit (the long range kit comes with a backing plate and 8 extra reflectors, you will need to add the reflector from the standard kit to the long range kit with the screws provided) 80-100 metres add the reflector from the standard firebeam to the long range kit with the screws provided what position? A roof is considered flat unless the height of the apex is greater then 0.6m. If the roof is flat thefirebeam system can be placed anywhere under the roof between 0.3m and 0.6m below the roof, up to a maximum height of 40m from the floor.thefirebeam has a detection area of 7.5m ether side of the beam. If the roof is considered to have an apex, place thefirebeam system 0.3m to 0.6m down from the top of the apex, up to a maximum height of 40m from the floor. The maximum protected area either side of the beam can be extended by 1% for every degree of roof pitch, see the example below flat roof 0.3m - 0,6m 7.5m 0.3-0.6m 15m detection area 7.5m extra coverage due to apex angle 40m max 10 o 0.3-0.6m 15m + (15 X10%) =15m + 1.5m = 16.5m 8.25m 16.5m detection area 8.25m wall plan view min 0.5m you should always position the beam at least 0.5m away from any protrusion field of view should be a 50cm radius from the centre of the beam head Always mount thefirebeam system on a solid construction that is unlikely to flex Mount over 2.7m from floor level to avoid to people walking through the beam, and consideration should also be given to the possibility of obstruction by fork lift trucks and the like. Avoid pointing the head into direct sunlight. 3

installing and commissioning step one. mounting the head screw the head backing plate to the wall - always try to use as sturdy location as possible, such as brick or major structural steels (avoid mounting to outer metal cladding etc) 2 knock outs are provided on both sides wire to low level controller using bottom colour coded terminals wire into system as required See generic wiring diagram on the following page. For other configurations contact us or view our website. screw in through holes provided outside of the rubber seal Also available adapter plate use this accessory for easy mounting to unistrut fabrication. Holes are pre drilled to the correct pitch of the head and conveniently positioned for use with unistrut connect the head to the base plate by first plugging in the connector then screw down the head screws with the 3mm allen key provided step two. mounting the controller Important mount the controller at eye level and with easy access screw in through holes provided outside of the rubber seal wire to head using colour coded terminals 4

generic wiring configuration switch 4 on all rest off to fire panel to controller BROWN + supply (10.2-30 Vdc) BLUE - supply (return) BLACK zone + GREY zone - GREEN earth (screen) FIRE and EOL components as specified by the panel manufacturer Supply Voltage 12Vdc to 24 Vdc +25% -15% Quiescent Current 3mA Alarm Current 3mA Aligning Current 3mA Fault / Fire relay contact rating 2A @ 30Vdc 5

step three. commissioning to commission the fire beam you must follow the simple procedure below 1. do NOT put up the reflector or COVER it if in place already! 2. power up the unit - you will see then the screen will default to 3. access the menu system by pressing enter 4. scroll through the menus until you get to commissioning 5. enter commissioning and enter pre-alignment (pre alignment is probably the most important part of commissioning) 6. you will see this screen signal power receiver sensitivity received signal X (horizontal) motor position Y (vertical) motor position P= pre-alignment 6

7. signal power starts at 10% and the receiver sensitivity starts at 5% and automatically increases until a received signal from the blank wall without the reflector of between 5 and 7% is achieved, it will then stop received signal if you are covering a distance of over 50 meters you should be achieving signal power of over 60%, if you are receiving less it s possible that you are picking up a reflection from something other than the target blank wall. By moving the beam (looking at the wall) left (x-) right (x+) up (y+) and down (y-) you can move the beam away any obstacles to achieve higher signal power Y + X - X+ Y - obstacle roof line target wall 8. Once you are happy with the power readings press enter and confirm by pressing the right key. The manual alignment menu will appear press enter to enter. press enter in pre-alignment and then confirm by pressing the right key press enter to enter manual mode you will now seen this screen 7

9. NOW place or uncover the reflector on the blank wall directly opposite the beam head with a clear path though obstructions such as girders etc. It is important that there is a clear line of vision between the reflector and any obstruction -the beam head must see at least 200mm of clear wall around the reflector to enable successful auto alignment. clear vision around the reflector Once the reflector is in place the AQ value should jump up meaning that the head is now seeing the reflector. The minimum response you need to see is 40% (below this figure the beam will not self align in the next procedure) the higher the number the better - this can be over 100% If you have received a AQ reading of over 40% go to Auto Alignment point 10. you need a reading of at least 40% to proceed to Auto alignment. If you do not receive an AQ signal of 40% it means the beam head is not seeing the reflector. You will need to move the beam head until you receive an AQ reading of above 40% ideally over 100% If you are presented with the screen below (AQ-air quality could be any number up to 40%) Now look at the position of the reflector in relation to the beam head. You will need to angle the beam toward the reflector by moving the head about its X or Y axis using the internal motors In the example on the next page you will notice that the reflector is below the line of fire of the beam. So in this case you would need to lower the angle of the beam (-Y) until you receive a AQ (Air Quality) reading above 40% sensitivity. (40 steps of the motor = 1degree of movement) 8

40 steps = 1 degree of movement beam head reflector Y - X - Y + X+ Adjustments can now be made to the X and Y axis by using the left(x-), right(x+), up(y+), down(y-) keys. Looking at the reflector this will move the beam across the reflector like so (40 steps = 1degree) (you can hold the key down for faster increments) Y - in the example above moving the y axis down(y-) results in a greater % air quality Wait for x / y values to finish moving to asses your AQ result Try and achieve as good a result as possible - it must be over 40% or auto align will abort. (the better the result the shorter the auto align time will be - a result over 100 is good!) Press enter to exit manual mode and enter Auto Alignment 10. Having received a AQ reading of over 40% in manual mode press enter to exit manual and enter again to enter auto alignment press enter and the beam head will automatically align on the reflector 9

first you will see the signal power readings and receiver sensitivity drop if the received signal reading is over 100%. once at 100% or if the reading is under 100% thefirebeam will automatically move its X and Y axis until it is positioned on the reflector. (This operation could take 30 minutes or more) Note: if you break the beam whilst it s auto aligning it will automatically abort, reset by pressing the left back button and pressing enter to re-start auto alignment the alignment could take up to 30 minutes or more depending on how much aligning is required. Once complete you will see a Align Complete notification, simply press the left back button to exit and your firebeam is now ready and commissioned you will now see this screen. Air Quality may fluctuate slightly around a couple of %.above and below 100 step four. testing to test that the firebeam is aligned correctly you will need to carry out two tests. 1. a filter test for Fire place the filter provided over the eyes of the firebeam. having done this (after 10 seconds) the red fire LED will flash on both the head and on the controller and the word FIRE will replace NORMAL on the low level controller display 2. a reflector test, to check that the beam is reflected back from the reflector cover the reflector completely within one second. If the beam is correctly targeted on the reflector a fault condition will occur (after 10 seconds). A amber LED will flash on both the head and on the controller, the word FAULT will appear in the display Your firebeam has now been commissioned and tested. 10

screen and menu system issue 0026-02 press enter / menu to enter menu system NORMAL FIRE FAULT ERROR ALIGN no comms beam head is performing a self re-alignment procedure to enter sub menus to decrease to increase to exit sub menus default 35% adjustable between 25% and 50% shows ( ) when updating * If alarm is set to latching and you need to reset from fire press enter to see this screen and enter again to reset and return to the normal screen, if in fire you will need to press back to go back to the main menu. If set to auto reset it will reset to normal automatically default autoreset use left and right buttons to change shows ( ) when updating * default 10s use left and right buttons to change shows ( ) when updating * default 10s use left and right buttons to change shows ( ) when updating * default off use left and right buttons to change 11

to enter sub menus back to exit sub menus view amount of internal gain made to compensate for dirt build up on beam lenses -128% to +128% counts events since alignment or reset 0-255 to test beam press enter - the power will slowly drop as can be seen in the dropping air quality. When the air quality drops past the pre set threshold the beam will fall into fire remember that there is a delay time set for time to fire 12

to enter sub menus to exit sub menus pre- alignment is the first stage of alignment - this should only be used without the reflector make adjustments by using the left, right, up and down keys (this moves the beam in these directions across the face of the reflector- with your back to the beam) this symbol will appear next to the number when you move the beam make adjustments by using the left, right, up and down keys (this moves the beam in these directions across the face of the reflector- with your back to the beam) this symbol will apear next to the number when you move the beam 13

if the beam is obstructed during auto alignment the alignment will be aborted press back to return to auto alignment and enter to resume auto-alignment once alignment is complete you will see the screen below press back to return to the main screen 14

to enter sub menus to decrease to increase shows output power strength to exit sub menus shows ( ) when updating * to decrease to increase compensation amplifier shows ( ) when updating * to decrease to increase shows sensitivity of receiver shows ( ) when updating * shows temperature at beam head screen used by The Fire Beam help desk screen used by The Fire Beam help desk software versions for the head and controller 15

technical specifications Electrical Specifications: Supply Voltage. 10.2 to 40 VDC Supply Current. 3mA (constant current) in all operational states Environmental Specifications: Temperature. -10 C to +55 C Humidity. 10 to 95% RH Non-condensing Protection Index. IP65 when suitably mounted and terminated Mechanical Specifications: Beam Head. 180mmH x 155mmW x137mmd Weight 1.1Kg Controller. 185mmH x 120mmW x 62mmD Weight 0.55Kg 40KIT80 Mid-Range Reflector. 293mmH x293mmw x 5mmD Weight 0.8Kg 80KIT100 Long Range Reflector. 394mmH x 394mmW x 5mmD Weight 1.8Kg ADAPTER. 270mmH x 250mmW x 5mmD Weight 0.6Kg (mounts the Beam Head onto unistrut) Optical Specifications: Optical Wavelength. 870nm Maximum Angular Alignment. ±15 Maximum Angular Misalignment. (static not auto-aligning) Beam Head ±0.75 Reflector ±2 Operational Specifications: Protection Range: FIREBEAM. Standard Product 5 to 40 metres 40KIT80. Mid-Range Reflector Kit 40 to 80 metres 80KIT100. Long Range Reflector Kit 80 to 100 metres Alarm Sensitivity Levels: 25%(1.25dB) to 50%(3dB) in 1%(0.05dB) increments (default 35% (1.87dB)) Alarm Condition: Obscuration drops to below pre-defined sensitivity level. Time to Alarm Condition adjustable 2 to 30 seconds in 1 second increments (default 10 seconds) Alarm Indication: Controller Status FIRE Controller Red Flashing LED 0.5 Second Head Red Flashing LED 1 Second Alarm Relay Change Over (CO) Contact Rating 2A @ 30 VDC Test/Reset Features: Beam test function by controller Alarm latching/auto-reset selectable (default auto-reset) Alarm reset in latching mode by controller reset function, removing power for >5 seconds, apply 12 to 24 VDC to reset connections in Beam Head. Fault Sensitivity Level: 90% Fault Condition: Obscuration drops to below the fault sensitivity level within 1 second Power Down or Supply Voltage < 9 VDC Commissioning modes, Pre-Alignment and Auto Alignment Beam turned off during Beam Maintenance (auto resets in 8 hours to normal) Time to Fault Condition adjustable, 2 to 60 seconds in 1 second increments (default 10 seconds) Fault Indication: Controller Status FAULT Controller Yellow Flashing LED 1 Second Head Yellow Flashing LED 1 Second Fault Relay Change Over (CO) Contact Rating 2A @ 30 VDC Normal Condition: Obscuration level is above the Alarm sensitivity level Controller Status NORMAL Controller Green Flashing LED 1 Second Programmable on/off Head Green Flashing LED 1 Second Programmable on/off Auto-align/Beam Contamination Compensation: Auto-align during normal operation if obscuration drops below 90% (doesn t effect normal operating mode) Beam Contamination Compensation 4 hour monitoring. Compensation data available at the controller