MIDI-MAESTRO SERVO DRIVE ELECTROMAGNETIC COMPATIBILITY DATA

Similar documents
Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

EMC Installation / Application Guidelines VECTORSTAR (VSA) Series Electronics MVS001H. EMC / CE Guidelines

Good EMC Design Principles: cable routing

TEST REPORT EN (1997) +A1 (2001)

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

38 Series - Relay interface modules A

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Screened cable and data cable segregation

Rack mounted telephone- and leased line modem for industrial applications

Cable Solutions for Servo and Variable Frequency Drives (VFD)

38 Series - Relay interface modules A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

MasterINTERFACE 39 Series - Relay interface modules

Technical Article. EMC filters for medical devices

Waveguide Access Point WGA631. Product Guide

Telephone- and leased line modem for industrial applications TD-36

Separation of power and information technology cabling

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

EMC Standards: Standards of good EMC engineering

STRATO LED Drivers 70W, Single output

An extended EMC study of an electrical powertrain for transportation systems

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

MasterINTERFACE 39 Series - Relay interface modules

Technical Article MS-2443

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

15 Series - Electronic step relay and dimmer. Features SERIE

Energy Management Energy Meter Type EM23 DIN

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

White Paper: Electrical Ground Rules

80 Series - Modular timers 16 A. Features

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

EMC Test for Compliance with EU EMC Directive 2004/108/EU

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

80 Series - Modular timers 16 A. Features

Kit Watt Audio Amplifier

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Relés e Contatores de Estado Sólido SIRIUS

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Drayton Digistat +2RF/+3RF

Electromagnetic Compatibility Considerations for Switching Power Supplies

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

RX-AM4SF Receiver. Pin-out. Connections

ADACSNET USB Control Module

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

The impact of the New EMC Directive 2004/108/EC

Grounding Demystified

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

7. Technical Notes Table of Contents

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Video Camera Installation Guide

SURGE PROTECTIVE DEVICES

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Current Probes. User Manual

Coupling/Decoupling Networks (CDN)

Module 11: Conducted Emissions

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

The ITER Earthing Topology: Mesh-Common Bonding Network

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

R.C.C.B. s two-pole LEXIC

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

ST Series POWER SUPPLIES USER INSTRUCTIONS

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

TX OPEN RS232/485 module

Bulletin 150 SMC Flex Smart Motor Controller Specifications

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

ILB, ILBB Ferrite Beads

Guide to the electrical parameter classifications of IEC and IEC safety standards

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Comm5 Wiring Installation

Unified requirements for systems with voltages above 1 kv up to 15 kv

EMC Expert System for Architecture Design

Electromagnetic (EMI) shielding

Altivar 71. Network braking units VW3 A User's manual. Retain for future use

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Dual Chamber Temporary External Pacemaker

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Rules for Classification and Construction Additional Rules and Guidelines

User Guide. AC Variable Speed Drives kW / 1HP - 250HP V Single and 3 Phase Input. Installation and Operating Instructions

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

Installation Guide. Part Number: Issue: 2.

AND9015. A Solution for Peak EMI Reduction with Spread Spectrum Clock Generators APPLICATION NOTE. Prepared by: Apps Team, BIDC ON Semiconductor

Transcription:

MIDI-MAESTRO SERVO DRIVE ELECTROMAGNETIC COMPATIBILITY DATA PRODUCT DCD 140 8/16, DCD 140 14/28 IMMUNITY The drive complies with the following international and European harmonized standards for immunity: Standard Type of immunity Test specification Application Level EN 61000-4-2* Electrostatic discharge 6kV contact discharge 8kV air discharge Module enclosure Level 3 ENV 50140* Radio frequency 10V/m prior to modulation Module enclosure Level 3 radiated field 80-1000MHz 80% AM (1kHz) modulation ENV 50141* Conducted radio frequency EN 61000-4-4* Fast transient burst 10V prior to modulation 0.15-80MHz 80% AM (1kHz) modulation 5/50ns 2kV transient at 5kHz repetition frequency via coupling clamp 5/50ns 2kV transient at 5kHz repetition frequency by direct injection IEC 1000-4-5 Surges Common mode 4kV 1.2/50µs waveshape Differential mode 2kV 1.2/50µs waveshape EN50082-1 Generic immunity standard for the residential, commercial and light - industrial environment EN50082-2 Generic immunity standard for the industrial environment Calls up basic standards marked * Control and power lines Level 3 Control lines Level 4 (industrial harsh) Power lines Level 3 AC supply lines: line to earth AC supply lines: line to line Level 4 Level 3 Complies Complies The immunity is achieved without any additional measures such as filters or suppressors. To ensure correct operation the wiring guidelines specified in the User Guide must be carefully adhered to. All inductive components such as relays, contactors, electromagnetic brakes etc. associated with the drive must be fitted with appropriate suppression, otherwise the immunity of the drive may be exceeded. 18/9/97 1/9 Issue2

CONDUCTED EMISSION Radio frequency emission in the frequency range from 150kHz to 30MHz is mainly conducted out of the equipment through electrical wiring. It is essential for compliance with emission standards that the recommended filter and a shielded (screened) motor cable are used. Most types of cable can be used provided it has an overall screen, for example, the shield formed by the armouring of steel wired armoured cable is acceptable. The capacitance of the cable forms a load on the drive and should be kept to a minimum. Compliance tests were done with cable having a capacitance between the three power cores and the shield of 412pF per metre (measured at 1kHz), which is typical of steel wire armoured cable. Wiring guidelines are given in Figure1 which shows full precautions where minimum emissions are required. When used with the recommended filters, the drive complies with the requirements for conducted emission in the following standard: Motor cable length Emission level (m) 1 I 10 I Key to table Standard Description Frequency range Limits I EN50081-2 Generic emission 0.15-0.5MHz 79dBµV quasi peak standard for the 66dBµV average industrial environment 0.5-5MHz 73dBµV quasi peak 60dBµV average 5-30MHz 73dBµV quasi peak 60dBµV average Application AC supply lines Conducted emission test data The conducted emission from a DCD 140 8/16 operating with the recommended filter, is shown in the average measurement plot No. 4048, Figure4, and quasi peak measurement plot No. 4049, Figure5. These show compliance with the industrial standard using 10m of screened motor cable. In the tests, a 380/105 VAC 2000VA isolating transformer (Soprel part number PN 4.91.449), was used to generate the three phase supply to the drive. The transformer was of standard construction and did not have a screen between primary and secondary. This component has the beneficial effect of reducing the lower frequency conducted emission from the drive, and must be used in conjunction with the input filter to achieve the stated emission levels. Recommended filters Motor cable length (m) Input filter (Roxbrugh Part Nos.) DCD 140 8/16 1 to 10 S-1213-10 * DCD 140 14/28 1 to 10 S-1213-10 * *available through Roxbrugh Electronics Ltd, UK. Tel +44 (0) 1724 281770. Schaffner filter, part number FN355-10/05, may be used as an alternative to the one listed in the table but it will be necessary to fit the following additional components, close to the filter s terminals, to achieve comparable performance: 1) 10nF Y rated capacitor connected N to E on the load side. 2) 100nF X rated capacitor star network connected between power lines on the line side. 18/9/97 2/9 Issue2

Related product standards The conducted emission levels specified in EN50081-2 are equivalent to the levels required by the following product specific standards: Generic standard EN50081-2 Conducted emissions from 150kHz to 30MHz Product standard EN55011 Class A Group 1 Industrial, scientific and medical CISPR 11 Class A Group 1 equipment EN55022 Class A Information technology equipment CISPR 22 Class A RADIATED EMISSIONS When installed in a standard metal enclosure according to the wiring guidelines in Figure 1, the drive will meet the radiated emission limits required by the generic industrial emission standard EN50081-2. Important note Compliance was achieved in tests using representative enclosures and following the guidelines given. Every effort was made to ensure that the arrangements were robust enough to be effective despite the normal variations which will occur in practical installations. However no warranty is given that installations built according to these guidelines will necessarily meet the same emission limits. The limits for emission required by the generic industrial emission standard are summarized in the following table: Radiated emission from 30 to 1000MHz Standard Application Frequency range Limits Comments EN50081-2 Enclosure 30-230MHz 40dBµV/m quasi peak at 10m Standard specifies limits of 30 and 37dBµV/m respectively at 230-1000MHz 47dBµV/m quasi peak at 10m a measuring distance of 30m; emissions may be measured at 10m if limits are increased by 10dB Test Data The test data is based on radiated emission measurements made on a standard steel enclosure containing a single DCD 140 8/16 140drive, in a calibrated open area test site. Details of the test arrangement are described: A standard Rittall enclosure was used having dimensions 1900mm (high) 600mm (wide) 500mm (deep). Two ventilation grilles, both 200mm square, were provided on the upper and lower faces of the door. The was fitted to the internal back-plate of the enclosure, the drive heatsink directly grounded to the back-plate using the metal mounting brackets. In the tests, no RFI filter was connected to the drive. Standard unscreened power cable was used to connect the enclosure to the supply. A standard 0.37kW DC servo motor, with tacho feedback, was connected by 4m of shielded cable (steel braided - type SY) and mounted externally. The shield of the motor cable was bonded to the back-plate using a metal clamp, it was not bonded to the enclosure wall at the point of entry. A 2m screened control cable was connected to the drive control terminals, but the screen was isolated from the cubicle wall. 18/9/97 3/9 Issue2

Emission measurements were made on the enclosure with the drive operating at 150rpm. No additional EMC preventative measures were taken, e.g. RFI gaskets around the cubicle doors. The following table summarizes the results for radiated emissions, showing the six highest measurements over the frequency range 30 to 1000 MHz: Frequency MHz Emission dbµv/m 30 34 40 32 36 40 33 36 40 34 35 40 50 33 40 52 33 40 Level required by industrial standard EN50081-2 at 10m The results show that the limit for the industrial emission standard is met with a margin of at least 4dB. Enclosure construction For many installations, an enclosure will have a back-plate which will be used to mount variable speed drive modules, RFI filters and ancillary equipment. The motor cable should be bonded to the back-plate close to the drive before it leaves the enclosure wall (Refer to Wiring guidelines in Figure1). However there is no disadvantage if the motor cable is bonded at the point of exit as well, through the normal gland fixings. Depending on construction, the enclosure wall used for cable entry may have separate panels and could make poor electrical contact at high frequencies with the remaining structure. If the motor cable is only bonded to these surfaces and not to a back-plate, then the enclosure may provide insufficient attenuation of RF emissions. It is the bonding to a common metal plate which minimizes radiated emission. In the tests described, opening the cubicle door had little effect on the emission level, showing that the enclosure design is not critical. Related product standards The radiated emission levels specified in EN50081-2 are equivalent to the levels required by the following product standards: Radiated emissions from 30 to 1000MHz Generic standard Product standard EN50081-2 EN55011 Class A Group 1 CISPR 11 Class A Group 1 Industrial, scientific and medical equipment EN55022 Class A CISPR 22 Class A Information technology equipment WIRING GUIDELINES The wiring guidelines on the following pages should be observed to achieve minimum emissions. The details of individual installations may vary, but details which are indicated in the guidelines to be important for EMC must be adhered to closely. The guidelines do not preclude the application of more extensive measures which may be preferred by some installers. For example, the use of full 360 ground terminations on shielded cables in the place of pig-tail ground connections are beneficial, but not necessary unless specifically stated in the instructions. 18/9/97 4/9 Issue2

Power supply Control circuits 0V common PLC Power supply Control circuits Counter 0V common CNC Ground busbar Fuses RFI filter Transformer AC supply L1 L2 L3 Ground Isolator Contactor Fuses or MCB Back-plate Power-ground busbar Enclosure Key to symbols Single power cable Three-core power cable Ground cable Connection to cable armour or shield Maximum length: 50mm (2 in) Armoured or shielded cable application Figure1 Wiring guidelines for Midi-Maestro 18/9/97 5/9 Issue2

KeytoFigure1 General features 1. Single power ground busbar or low impedance ground terminal. 2. Incoming supply ground connected to power ground busbar. 3. Connect grounds of any other circuits to power ground busbar. 4. Site ground if required. 5. Metal back-plate, safety bonded to power ground busbar. 6. System isolator, circuit contactors and fuses/mcb. 7. Isolating transformer to provide 105VAC supply to Midi-Maestro drive(s). 8. fuses. 9. AC supply/ground to other Midi- Maestro drive(s). 10. Safety ground for motor. 11. Motor frame ground connection, if required. 12. Optional motor line choke. Cables between drive and choke should not exceed 0.3m (12 in). Special features for EMC 13. heatsink directly grounded to the back-plate using the metal mounting brackets. 16. Connect drive DC and ground terminals to ground busbar using 2.5mm 2 cable. Maximum length: 0.5m (20 in). 17. A shielded (screened) or steel wire armoured cable must be used to connect the to motor. The shield must be bonded to the back-plate using an uninsulated metal cable-clamp. The clamp must be positioned no further than 100mm (4 in) from the drive when a motor line choke is not used. 18. Connect the shield of the motor cable to the ground terminal of the motor frame using a link that is as short as possible and not exceeding 50mm (2 in) in length. A full 360 termination of the shield to the motor terminal housing (usually metal) is beneficial. 19. Connect drive 0V to the ground busbar using a short connection. 20. Connect the 0V commons of the CNC and PLC to the ground busbar. 21. Avoid sensitive signal circuits in a zone extending 0.3m (12 in) all around drive. 22. Unshielded wiring to optional braking resistor(s) may be used, provided the resistor is either in the same enclosure as the drive or the wiring does not run external to the enclosure. Ensure a minimum spacing of 0.3m (12 in) from signal wiring and the supply side wiring of the RFI filters. 14. RFI filter mounted on the primary side of the transformer. The RFI filter casing is directly grounded to the backplate by the fixing screws. 15. Ground busbar (copper) mounted on insulated pillars, recommended bar size: 5 20 100/200mm. Connect to the power ground busbar using 10 to 20mm 2 cable, maximum length: 0.5m (20 in). 18/9/97 6/9 Issue2

VARIATIONS Interruptions to the motor cable The motor cable should ideally be a single run of shielded cable having no interruptions. In some situations it may be necessary to interrupt the cable, for example to connect the motor cable to a terminal block within the enclosure, or to fit an isolator switch to allow safe working on the motor. In these cases the following guidelines should be observed. Terminal block within enclosure The motor cable shields should be bonded to the back-plate using uninsulated cable-clamps which should be positioned as close as possible to the terminal block. Keep the length of power conductors to a minimum and ensure that all sensitive equipment and circuits are at least 0.3m (12 in) away form the terminal block. Using a motor isolator switch The motor cable shields should be connected by a very short conductor having a low inductance. The use of a flat metal bar is recommended; conventional wire is not suitable. The shields should be bonded directly to the coupling bar using uninsulated metal cable-clamps. Keep the length of power conductors to a minimum and ensure that all sensitive equipment and circuits are at least 0.3m (12 in) away. The coupling bar may be grounded to a known low impedance ground nearby, for example a large metallic structure which is connected closely to the ground. Isolator From the From the Coupling bar (If required) To the motor (Refer to Key to symbols in Figure1) Figure3 Connecting the motor cable to an isolating switch Back-plate Enclosure To the motor (Refer to Key to symbols in Figure1) Figure2 Connecting the motor cable to a terminal block in the enclosure 18/9/97 7/9 Issue2