Altivar 71. Network braking units VW3 A User's manual. Retain for future use
|
|
|
- Byron Lester
- 10 years ago
- Views:
Transcription
1 Altivar 7 User's manual Retain for future use Network braking units VW3 A
2
3 Contents Before you begin 4 Steps for setting up the braking unit 5 Checking the installation 6 Recommendations 3 Characteristics 4 Sizing 5 Dimensions 9 Mounting and temperature conditions 2 Recommendations for the electrical installation 22 Connection diagrams, fuses and associated cables 23 Operation on a neutral IT (isolated or impedance grounded neutral) system 28 Electromagnetic compatibility and wiring 29 Starting tests 33 Configuration 34 Troubleshooting 36 3
4 Before you begin Read and understand these instructions before performing any procedure with this braking unit. DANGER HAZARDOUS VOLTAGE Read and understand this User s Manual before installing or operating the braking unit. Installation, adjustment, repair, and maintenance must be performed by qualified personnel. The user is responsible for compliance with all international and national electrical standards in force concerning protective grounding of all equipment. Many parts in this equipment, including printed circuit boards, operate at line voltage. DO NOT TOUCH. Use only electrically insulated tools. DO NOT touch unshielded components or terminal strip screw connections with voltage present. DO NOT short across terminals PA and PC or across the DC bus capacitors. Install and close all the covers before applying power or starting and stopping the drive. Before servicing the braking unit - Disconnect the power and the control power supply. - Place a DO NOT TURN ON label on the disconnect at the head of the installation. - Lock the disconnect in the open position. Disconnect the power supply, including the 23 V control power supply, before working on the equipment. Wait for the charging LED to go off. Then follow the DC bus voltage measurement procedure described in the drive Installation Manual to verify that the DC voltage is less than 45 VDC. The LEDs on the speed drive are not accurate indicators of the absence of DC bus voltage. Electric shock will result in death or serious injury. 4
5 Steps for setting up the braking unit b Take delivery of the braking unit (see page 3) v Check that the catalog number printed on the label is the same as that on the purchase order. v Remove the braking unit from its packaging and check that it has not been damaged in transit. Steps to 4 must be performed with the power off b 2 Check the line voltage (see page 4) v Check that the line voltage is compatible with the voltage range of the braking unit b 3 Install the braking unit (see page 2) v Mount the braking unit in accordance with the instructions in this document v Install any internal and external options b 4 Wire the braking unit (see page 23) v Connect the braking unit to the 3-phase supply (L,L2,L3) v Connect the braking unit to the drive DC bus v Connect the control cable 5
6 Checking the installation Length of the DC bus The maximum inductance of the DC bus connecting output PA/+, PC/- on the drive to the braking unit must not exceed a set level, as this inductance results in an additional difference in potential on the DC bus when the IGBTs are open. To avoid an overload on the components of the braking unit, this difference in potential must not exceed VDC. The maximum inductance can be calculated using this and other characteristics of the braking unit (value of the DC bus capacitors and absolute value of the grid current). C ( ΔU L GL ) 2 max = This inductance must always be greater than or equal to the sum of the inductance of the DC bus on the frequency inverter and the inductance of the DC bus connection cables. The inductance of the DC bus on the frequency inverter must always be taken into consideration. The inductance per unit of length of the cables generally used for the power supply is in the region of.6 µh/m. The maximum length of the conductors lmax is calculated according to the following information: Values of the input capacities C Maximum DC voltage edge permitted during motor generator operation (ΔUGL= VDC) Maximum AC current level for the equipment î (=2*Irms) Inductance per unit of length L' Inductance of the coil Lzkd of the DC bus ˆ2 i The equation below can be used to calculate lmax: C I 2 ΔU GL L max = ZKD ˆ2 L' i L' Typical capacity of the DC connection inside the braking unit Braking unit VW3 A7... Power DC capacity 7-45 kw μf 7-35 kw 2 μf 6-2 kw 42 μf Example: C = 2 μf, ΔU GL = V, i = 27 A, a = 8 mm, r = 8.5 mm, μ = H/m For longer DC bus cables, additional capacitors must be installed (Please contact your local representative) 6
7 Checking the installation Operation on a generator It is possible to use a braking unit with an isolated line supply (for example: a diesel engine generating set), but there are restrictive rules limiting the power. G.4kV kva VW3A7... R 2kW M 2kW ATV7 M With a line supply whose architecture is similar to that shown in the diagram above, there are 2 additional restrictions: The power of the motor connected to the inverter must be less than half the nominal power of the generator. The total power of the two other loads must be more than double the power returned on the line supply. If these conditions are not verified, changing the motor to operation as a generator could result in a sudden overload. This overload is too high for the voltage regulator of the generator. The regulator reacts with an overshoot which leads to an overvoltage with the isolated line supply. RISKS OF INTERFERENCE CAUTION Overvoltages can cause serious damage to the frequency inverter and/or the braking unit and the other loads. Failure to follow this precaution can result in equipment damage. 7
8 Checking the installation Operation on a transformer If only some loads are operating on one section of the line supply, then the transformer that is connected must be capable of transporting the unused generated power from this section to the next voltage level without exceeding the voltage edge permitted in the line supply section. The nominal power of the transformer must therefore be one and a half times greater than the power generated outside the section, so that the harmonic and reactive components of the current can be transmitted. In the line supply section shown in the diagram below, these conditions are verified even if the other loads are disconnected. If the power that is generated is in the region of the nominal power of the transformer, then the transformer short circuit voltage must be fairly low (6% maximum) to limit the voltage increase in this section. The operation of the braking unit used with a sized transformer (for example in the case of a slip ring induction motor) is only permitted if the ratio of the power generated to the nominal power is considerably less than. kv Tr kva.4kv VW3A7... R 2kW M 2kW ATV7 M 6kW 8
9 Checking the installation Position of the commutation reactor If the frequency inverter is connected to an external commutation reactor, then the braking unit must be connected to the line supply (diagram below). If the braking unit is connected downstream of the commutation reactor, then the inductance of the reactor prevents the braking unit from synchronizing on the line supply and generates overvoltages, which can result in damage to the components of the braking unit. RISKS OF INTERFERENCE CAUTION Overvoltages can cause serious damage to the frequency inverter and/or the braking unit and the other loads. Failure to follow this precaution can result in equipment damage. Prohibited VW3A7... ATV7 M 6kW Same warning about the presence, also not permitted, of other commutation reactors upstream of the braking unit. 9
10 Checking the installation Line resistances and contact resistances The values of the capacitive currents of the cables depend on the conductive material. This is relevant for sizing. Aluminum conductors must have a larger cross-section than copper conductors due to their high resistivity. Whatever conductive material is used, the contact resistances of the connections must have a low impedance and the number of connections must be kept to the absolute minimum. Too many connections or contact resistances that are too high can result in overvoltages during power generation. ΔU Line supply U ΔU U U ΔU ΔU I VW3A7... ATV7 M Based on a stable line supply with for example a nominal voltage of 4 V with a return current of 8 A, and a connection with a contact resistance of mω, a voltage dip of 8 V occurs (a correct connection has a contact resistance of approximately mω). During power generation if there are 7 connection points to the line supply, this results in a total voltage of 456 V.
11 Checking the installation Connection of other loads Connection of other loads (for example ventilation or air conditioning enclosure) in parallel on the frequency inverter and the braking unit with a common circuit-breaker is not permitted (see diagram below). If this is nevertheless performed, then if the circuit-breaker trips, the connection to the line supply will be absent (loss of power and synchronization information for the braking units). The IGBTs then transfer the DC voltage directly to the other loads. The resulting quasi-rectangular supply voltage signal sends a current across the loads, whose waveform and level depend on their impedance. If the power consumption of the loads is too low, then the DC voltage and the output voltage of the braking unit increase during generation. This overvoltage can damage all the components that are connected. Line supply Prohibited Correct VW3A7... ATV7 M 6kW M RISKS OF INTERFERENCE CAUTION Overvoltages can cause serious damage to the frequency inverter and/or the braking unit and the other loads. Failure to follow this precaution can result in equipment damage.
12 Checking the installation Connection of other loads (continued) Line supply VW3A7... ATV7 ATV7 ATV7 M M M 6kW There are also risks of overvoltage for a structure such as that shown above. Even in this case, a circuit-breaker must be placed in each current return circuit. Correction circuit without reactor Correction circuits are used at the center of the line supply of a company. Interference and damage on these circuits have consequences on the line supply and can result in stoppage of the production process. Although they are no longer currently made, many correction circuits without reactor are in use. A wide variety of problems arise from the use of such correction equipment without reactor: Direct resonance Increase in resonance Switching transient Attenuation of central oscillations The fact that a company returns energy to the line supply is not the only reason for the creation of a resonance phenomenon. The power of the medium voltage transformer cos ϕ correction unit is the decisive element. The higher this power, the greater the risk of resonance. The second important factor is the harmonic load of the medium voltage line supply. This harmonic load is transmtted via the transformer and affects the low voltage level. More often than not the limits are exceeded by the 5th harmonic. 2
13 Recommendations Receipt Ensure that the equipment reference marked on the label conforms to the delivery note corresponding to the purchase order. Open the packaging and check that the equipment has not been damaged in transit. For successful setup, it is important to check that the braking unit, protection devices and mounting are correct. For more information, please contact your local representative. Capacitor discharge! Before any operation on or in the braking unit, disconnect the power line supply and wait 5 minutes for the DC bus to discharge completely. Measure the voltage on the DC bus before any intervention. This should be less than 6 V DC. Automatic restart! In certain cases, depending on its parameter setting, the drive may restart automatically when the power is restored. The safety of nearby equipment and people must be assured. General As a motor slows down on a deceleration ramp, it is working as a generator. A drive uses a rectifier and cannot return electrical energy to the distribution network. During operation as a generator, the voltage at the DC bus terminals increases due to the restoration of energy from the motor to the drive. This locks out the drive on a DC bus overvoltage fault. The restored power in the drive depends on the inertia of the load to be braked and the required braking time. The drive protects itself against locking out due to DC bus overvoltage by auto-adapting its deceleration ramp. If a shorter deceleration time is required, a BRAKING UNIT must be used. 3
14 Characteristics General characteristics Degree of protection IP 2 Maximum relative humidity Class F humidity without condensation 5 85% Ambient temperature around the unit Operation C ( F) (4 + 4) without derating Up to 55 C (3 F) with current derating of 3% per C (34 F) above 4 C (4 F) Storage C ( F) ( ) Maximum operating altitude m without derating 4 derating the current by 5% per additional m Electrical characteristics Type of module VW3 A VW3 A Supply voltage V a 4 a 46 Nominal voltage ± % V a a Operating frequency Hz 4 6 ± % Overload capacity A.2 x maximum current (Irms) Efficiency 97% (3% of thermal losses) Power factor Fundamental frequency component.7.95 Connection characteristics VW3 A7 2 VW3 A , VW3 A7 23, 232 VW3 A , VW3 A VW3 A7 2 22, VW3 A Type of module Maximum wire size 25 mm 2, connected on a bar, M5 35 mm 2, connected on a bar, M6 95 mm 2, connected on a bar, M8 5 mm 2, connected on a bar, M 4
15 Sizing Line voltage: a 4 V Maximum current Irms Continuous braking power Fast-acting semiconductor fuses Catalog number Weight a c a a A A kw A V kg VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A Line voltage: a 46 V Maximum current Irms Continuous braking power Fast-acting semiconductor fuses Catalog number Weight a c a a A A kw A V kg VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A VW3 A
16 Sizing To calculate the correct value of the power that is generated, the fact that the actual instantaneous power generated depends on the actual voltage of the line supply at each moment must be taken into account. The following formula is used to calculate the power generated (during operation as a generator: cosϕ = ): P = U rms I rms 3 cosϕ The maximum power generated is calculated according to the instantaneous rms voltage of the line supply and according to the maximum rms current of the device in question. Example: The VW3 A7 25 has a maximum generated power of 45 KW and a maximum rms current of 65 A (refer to the technical data). The nominal voltage of the line supply is, for example, 4 V. This gives: P = 4V 65A 3 = 4533W That is, approximately 45. kw. If the instantaneous rms voltage of the line supply is less than 395 V for a moment, then the maximum power generated is also reduced: P = 395V 65A 3 = 4447W That is, approximately 44.5 kw. 6
17 Sizing Example of how to use characteristic curves Note: These curves are given for a voltage of 4 V or 46 V, depending on the model. VW3 A7 24, A7 232 (Continuous braking power = 2.5 kw) () Example of how to use the curves: Required braking power of 27 kw. The intersection point between the braking time and the time between 2 braking operations must be on or below the relevant curve. Point A for a braking time of 2 minutes, there must be at least 5 seconds between 2 braking operations. Braking time (min.) kw 5 33 kw A Time between braking operations (min.) VW3 A7 24, A7 232 (Continuous braking power = 2.5 kw) () VW3 A7 25, A7 233 (Continuous braking power = 26 kw) () Braking time (min.) kw Braking time (min.) kw kw kw Time between braking operations (min.) Time between braking operations (min.) VW3 A7 26, A7 234 (Continuous braking power = 32 kw) () VW3 A7 27, A7 235 (Continuous braking power = 38 kw) () 5 5 Braking time (min.) kw Braking time (min.) kw kw.5 9 kw Time between braking operations (min.) Time between braking operations (min.) () Power indicated for a temperature of 35 C (95 F). 7
18 Sizing VW3 A7 28 (Continuous braking power = 38 kw) () VW3 A7 29, A7 239 (Continuous braking power = 86 kw) () Braking time (min.) kw Braking time (min.) kw kw kw Time between braking operations (min.) Time between braking operations (min.) VW3 A7 2, A7 24 (Continuous braking power = 2 kw) () VW3 A7 2 (Continuous braking power = 35 kw) 5 5 Braking time (min.) kw Braking time (min.) kw kw kw Time between braking operations (min.) Time between braking operations (min.) VW3 A7 22 (Continuous braking power = 2 kw) VW3 A7 24 (Continuous braking power = 24 kw) 5 5 Braking time (min.) kw Braking time (min.) kw kw kw Time between braking operations (min.) Time between braking operations (min.) () Power indicated for a temperature of 35 C (95 F). 8
19 Dimensions VW3 A7 2 25, 23, 232 Mounting recommendations H b H u 5 4xØ u 7 u 7 c = G = a u 5 VW3 a b c G H H Ø A7 2, A A VW3 A , Mounting recommendations 4xØ H H H2 b u 5 u 7 u 7 c = G = a VW3 a b c G H H H2 Ø A A
20 Dimensions VW3 A7 29, 2, 238, 239 Mounting recommendations u 5 2xØ8.5 4xØ u 7 u = 35 = 38 VW3 A7 2, 22, 24, 24 Mounting recommendations 2xØ 4xØ H H2 b H u u 7 u 7 c = G = a VW3 a b c G H H H2 Ø A7 2, A7 22,
21 Mounting and temperature conditions Required mounting position The braking unit has been designed to be mounted on a vertical wall only (+/- 5 ). The unit can only be mounted on a smooth surface without the use of any type of spacer. It must be mounted in this way to ensure correct circulation of the cooling air. Important recommendations Leave sufficient free space! - Leave a horizontal distance of at least 7 mm between the braking units and the other components, and between the braking units and the enclosure walls. - Leave a vertical distance of at least 7 mm between the braking units and the other components, and between the braking units and the enclosure walls. Check that there are no obstacles to the entry and exit of the cooling air. Leave a minimum distance of 5 cm at the air intake and outlet apertures. If the cooling air is polluted (dust, grease, corrosive gas) this may hamper some of the functions of the braking unit. - Take appropriate measures, for example: Keep the cooling air separate, fit air filters, clean regularly. Do not exceed the acceptable ambient temperature during use. A dissipated thermal power of 3% of the maximum nominal power must be taken into account. The air temperature must not exceed 4 C (4 F) in the vicinity of the braking unit. The air intake and outlet apertures at the top and bottom of the braking unit must not be covered by installation equipment such as cable ducts or other equipment. The required air flow rate depends on the size of the braking unit (nominal power and nominal voltage). Braking module VW3A7 4-23, 7-23, 2-23, 8-23, 22-23, VW3A7 7-4, 3-4, 22-4, 33-4, 45-4 VW3A , 33-46, VW3A7 8-5, 33-5, 45-5 VW3A , 5-23, VW3A7 7-4, 9-4, 35-4 VW3A7 7-46, 9-46, -46, VW3A7 7-5, 9-5, -5, 25-5 VW3A () VW3A () VW3A () VW3A () VW3A () VW3A7 9-23, 5-23 VW3A7 6-4, 2-4, 25-4 VW3A7 4-46, 6-46 VW3A7 4-5, 6-5 VW3A7 5-69, Required air flow rate (m 3 /h) () Some specific models have slightly different dimensions. 2
22 Recommendations for the electrical installation Protection of the braking unit RISKS OF INTERFERENCE CAUTION The braking unit contains components that are sensitive to electrostatic discharge. During the installation and wiring phases, personnel must comply with the rules of international standard IEC 747., section 9. Basically, before starting work, personnel must discharge themselves of any electrostatic voltage by touching the grounding cable screw located on the unit or a grounded surface of the enclosure. Failure to follow these precautions can result in equipment damage. 22
23 Connection diagrams, fuses and associated cables The connections can be accessed by removing the side screws and connection terminal cover from the unit. The cables must pass through a cable gland located on the wiring plate. Electrical power supply Fuses RISKS OF INTERFERENCE CAUTION When you remove the cover, take care not to damage the cables that lead to the display. Failure to follow this precaution can result in equipment damage. The braking unit is equipped with fuses for semi-conductors. The on-load voltage drop must be taken into consideration when choosing the cable cross-section (See section Checking the installation, page 6). Protection of the braking unit cables (L,L2,L3) and the connections to the line supply: - by commercially available cable protection fuses - the fuses must comply with the appropriate standards for the site. - the nominal voltage of the fuse must comply with the voltages for the site. Protection of the braking unit and the connections to the DC bus (+UG,-UG): - The fuses are part of the braking unit The installer/user of the circuit is responsible for compliance with the appropriate standards. WARNING Overcurrent protective devices must be properly coordinated. Use the fuses recommended in this document. Failure to follow these instructions can result in death or serious injury. Connections All the connections must be a short as possible and have a low impedance. Shielded cables must be used in order to comply the EMC directives (in accordance with current standards such as EN 68.3). Connect the line supply (line reactor) to terminals L, L2 and L3 on the braking unit. Only a three-phase supply is permitted. A defined phase sequence (indirect rotation of the field) must be followed when connecting the braking unit to the line supply. The braking unit has a phase sequence check. If the rotating field is incorrect, an error message is displayed via an LED as follows: "incorrect phase rotation direction" or "phase loss". In this case, two phases connected to the braking unit must be inverted. Connect the ground of the power supply cables to the ground connection screw on the braking unit. The DC bus wires used to connect the drive and braking unit must be connected to the DC fuse carrier. It is essential to comply with the correct polarities. The inversion of the + (PLUS) and the - (MINUS) will prevent correct operation of the braking unit. 23
24 Connection diagrams, fuses and associated cables Wiring diagram L L2 L3 N PE Q 3 5 L 23 V N ATV 7Hppppp PA/+ PC/ + U V W F KM () F2 F3 F4 (2) A2 L L2 L3 L N PE (3) (3) (3) A R/L S/L2 T/L3 RA RC RB R2A R2C + 24 U/T V/T2 W/T3 LI X M 3 Components for use with the unit (for a complete list of references, see our Motor starter solutions. Power control and protection components specialist catalogue). Ref. Description A ATV 7 drive A2 Network braking unit F 2 A fuse, a 23 V F2 F4 For the fuses, refer to the reference tables on page 5 Q Residual current circuit breaker 3 ma. Provides protection against earth leakage faults. () Optional additional EMC input filter (2) Line reactor recommended (3) For ATV 7HC4N4 drives combined with a 4 kw motor and ATV 7HC5N4, see the drive Installation Manual. 24
25 Connection diagrams, fuses and associated cables Size of DC bus fuses (F, F2, F3) depending on the drive rating Fan power supply () Nominal voltage of fast-acting semi-conductor fuse All braking units have two terminals (blue terminal = neutral [N], grey fuse terminal = phase [L]) for supplying internal fan(s). The fuse inside the fuse terminal is installed in order to protect the internal wiring and is the following type: 2 A, 5 V, size: 5*3 mm Control cable Connect the control cable to the X2 terminals on the braking unit control panel. Do not place the control cables near the power supply cables as the power supply cables cause interference. Connect the shielding of the control cables with the metal connector on the guide, over as large an area as possible. Control functions Fast-acting semi-conductor For drives fuses () A ATV 7H37M3 HU5M3 25 ATV 7HU22M3 HU4M3 5 ATV 7HU55M3, HU75M3 ATV 7HDM3X HD8M3X 6 ATV 7HD22M3X, HD3M3X 25 ATV 7HD37M3X, HD45M3X 35 ATV 7HD55M3X 5 ATV 7HD75M3X 63 ATV 7H75N4 HU22N4 25 ATV 7H75N4 HU4N4 5 ATV 7HU55N4 HDN4 8 ATV 7HD5N4 HD22N4 ATV 7HD3N4, HD37N4 6 ATV 7HD45N4 2 ATV 7HD55N4 25 ATV 7HD75N4 35 ATV 7HD9N4 35 ATV 7HCN4, HC3N4 4 ATV 7HC6N4 5 ATV 7HC2N4 63 ATV 7HC25N4, HC28N4 8 ATV 7HC3N4 ATV 7HC4N4, HC5N4 25 Line voltage Nominal voltage of fast-acting semi-conductor fuse a V V The control terminals are on the braking unit control card and are indicated by X2. These terminals can be removed easily using a simple operation. (see diagram Use of the terminals, page 27) The control card must always be configured for the voltage of the line supply. The contacts of the fault relay on the X2 terminals can be connected to the outside. It is also possible to perform an external reset or switching functions by connecting them to the drive or the PLC. 25
26 Connection diagrams, fuses and associated cables Layout of the control panel X3 terminals for connection to the drive card X5 and X8 terminals for option J4 X3 X8 X5 TR TR2 TR3 L4 TR6 TR4 TR5 J LD5 LD3 J6 J5 J3 J7 LD4 LD2 X X4 J8 LD X2 X terminals: synchronization with line supply Type of control card X4 terminals for connection to the signaling card LED Green:phase break.red:phase breake 2.red:UCE/overcurrent orange:overheating yellow:general error X2 terminals external message and control 26
27 Connection diagrams, fuses and associated cables Use of the terminals X General error relay Terminals 5 and 6 connected internally to temperature supervision + - External OFF External ON/RESET ON/RESET Terminals to 4 (refer to the diagram above) These terminals are connected to two volt-free relays (one is normally open, the other is normally closed) with a maximum load current of 5AAC or 3ADC. Maximum voltage V DC, V AC. The relay is shown in open position in the above diagram. The relay closes if: The line supply is OK 2 There is no fault and possibly after an ON/RESET pulse. After an OFF pulse, a general fault is displayed while the relay opens. Terminals 5 and 6 These terminals are already used for supervision of the internal temperature of the heatsink. Terminals 7 and 8 (use shielded cables only, maximum length:.5 m) OFF signal These terminals can be used for an external OFF signal (normally open contact) to stop the braking unit. The OFF signal stops the braking immediately. If this is performed in generator mode, the drive trips immediately afterwards, due to the excessively high voltage of the DC bus. Terminals 9 and (use shielded cables only, maximum length.5 m) ON / RESET signal These connections can be used for an external ON signal (normally open contact) to start/reinitialize the braking unit. RISKS OF INTERFERENCE CAUTION Do not use external voltage in the connections of terminals 5 to : unexpected actions and damage can occur. Failure to follow these precautions can result in equipment damage. Terminals and 2 (use shielded cables only ) These connections can be used for an external ON signal (external voltage of 2-24 V DC, for example from a PLC, short duration pulse) to start or reinitialize the braking unit. (Connect the "Plus" to terminal and the "Minus" to terminal 2) 27
28 Operation on a neutral IT (isolated or impedance grounded neutral) system Types of electrical network and their main characteristics Comply with the restrictions relating to each type of network. If you want to use braking units on types of network that are not listed in the table below, please contact our technical experts. Network type Use of the braking unit Note Star connection with grounded neutral Star connection with isolated or impedance grounded neutral With grounded active neutral Permitted Permitted after consultation with the manufacturer and possible modification of the unit Permitted after checking with the manufacturer Comply with the technical data for the unit Specification of the cables used The cables used must comply with the specifications for the site (for example UL or UL-c) The restrictions concerning the minimum cross-section of the grounding cables must be adhered to! The efficiency of a shielded cable is dependent on: - A correctly shielded connection - The quality of the connection of the shielding - Low impedance of the shielding (only use tinned copper or nickel-plated copper shielding!). 28
29 Electromagnetic compatibility and wiring To install a braking unit in an EC approved control system, the following measures and warnings must be taken into account: General Assembly Filters Shielding Grounding The user is responsible for compliance of the application with EC directives. Connect the braking unit and the EMC filter to the grounded mounting plate with a cable whose cross-section is as large as possible: - Mounting plates with conductive surfaces (coated zinc or stainless steel) provide a permanent contact. - Varnished cards must not be used for installations that are to comply with EMC standards. If you use several mounting plates: - Connect as large an area as possible of the mounting plate (for example with copper strips). Check that the power supply cables and control cables are separated. Use the EMC filters that are assigned to the braking unit. EMC filters reduce high frequency interference from a prohibited value to a permitted value. Metal cable connectors provide a connection between the shielding and the unit over a large area. If there are breaks in the shielding at all the ends in the cable route: - Connect the cable shielding to the mounting plate over a large area If the power supply cables between the EMC filter and the braking unit are longer than 3 mm: - Use shielded power supply cables - Connect the shielding directly to the drive/braking unit mounting plate and to the EMC filter mounting plate. Shield the control cables: - Connect the shielding to their terminals via the shortest possible route. All metal parts (braking unit, drive, EMC filter) must be connected to a common ground (PE). Comply with the minimum cable cross-sections defined in the safety directives: - From an EMC point of view, it is the area of the cable and the contact with the mounting plate that is important for operation, rather than the cable cross-section. Braking units are electrical units for use in industrial and commercial equipment. In accordance with the EMC directive, 89/336/EEC, it is not compulsory to mark these braking units, although in the sense of the directive and the EMC law these components are designed for installation by an electromechanical engineer and cannot be used autonomously. Compliance with the protection objectives of the EMC directive must be proved by the installer or the user of the machine or the equipment. If EMC filters provided by Telemecanique are used, and if the conditions below and the installation directives are followed, then the compliance of the measures is assured. Conditions: The braking unit, combined with the connected EMC filters, has been designed for use under the conditions defined by class "A" ("B" on request). Definition conforming to the basic standards: EN58-2 for emission EN582-2 for immunity 29
30 Electromagnetic compatibility and wiring Installation To avoid coupling interference, the following cables must be at least 5 cm apart: a) Network/power supply cables b) Motor and drive cables c) Control and data cables (low voltage range < 48 V) To obtain a low impedance HF connection, the grounding cables, the shielding and other metal connections (for example: mounting plate/ mounted units) must be made using as large an area as possible with the metal conductive part. Use grounding cables and a grounding network with as large a cross-section as possible (minimum mm2) or metal strips. Use shielded copper or tinned copper cables. Shielded steel cables are not suitable for high frequency applications. Connect the shielding using metal clips or connectors to the grounding connections. Do not extend the shielding with a single wire! If external EMC filters are used, they must be installed no more than 3 cm away from the noise source, and must have low impedance connections and contacts. Relays, magnetic contactors, etc, must always be fitted with varistors, RC circuits or diode filters. All connections must be as short as possible and must be positioned as close as possible to the ground. Unconnected wires act like antennae. Avoid current loops in all cables. Connect unused cables to the ground at both ends. If unshielded cables are used, twist the pairs to attenuate the non asymmetric noise. Connection of an EMC filter Filtered cable to drive Busbar connected to the mounting plate over a large area Connection of RFI filter to mounting plate over a large area Ground attachment Equalization of the potential to the building ground Mounting plate Power supply cable Connected protective cable 3
31 Electromagnetic compatibility and wiring Design of EMC compliant enclosure Enclosure 2 Wiring between the EMC filter and the drive 3 EMC filter 4 Line supply cable 5 Wiring between the EMC filter and the braking unit: cable cross-section conforming to the short circuit protection 6 Motor wiring 7 Control wiring 8 Wiring from the DC bus to the braking unit (DC) 9 Common central point mounting plate (Star connection) Equipotential link Additional grounding cable 2 Braking unit 3 Connection to the power supply 4 PLC 5 Drive 6 Power supply fuses 7 Magnetic power supply switch 3
32 Electromagnetic compatibility and wiring Comments A system is generally divided into one zone for the power electronics and one zone for the control electronics. This is important, whether the system is installed in one enclosure or spread over several enclosures. It is recommended that a shielding screen is fitted, due to the high noise emission of the power supply cables. This screen must have a low contact resistance with the frame or the mounting plate (remove the varnish!). The installed braking unit and the connected EMC filter must form one unit, that is, they must be connected via a mounting plate with no insulating varnish. The connection between the braking unit and the EMC filter must be shielded. The shielding must be connected to ground at each end. The cable must not exceed 3 mm. The braking unit mounting plate must be the connection point for the grounding and the shielding of the machine or the equipment. If the drive or another component of the equipment causes interference, the HF connection of this component will be poor. It can be improved by an additional grounding network. The leakage currents increase when EMC filters are used. When the leakage current is greater than 3.5 ma, one of the following conditions must be met: - Copper protective cable whose cross-section is greater than mm 2 - Supervision of the protective cable by a module that trips in the event of a fault. - Second cable connected in parallel with the protective cable via separate terminals. This cable must be VDE / part 54 compliant. Installation of the control cables The shielding of the digital signal cables, which are connected to the terminals, must be connected to the shielding strips or directly to the grounded plate, in order to reduce the impedance. The shielding of the digital signal cables, which are connected to the terminals, must be connected over as large a surface area as possible. If the screen is grounded via a single wire, there is a 7% increase in the noise. Commercially available cable clips are suitable for connecting the shielding. If unshielded signal cables are used, use twisted pairs only. 32
33 Starting tests RISKS OF INTERFERENCE CAUTION Check the wiring of the braking unit (short circuits and ground faults) before it is turned on for the first time If the wiring is not correct, unexpected operation of the drive and/or the braking unit is possible. Failure to follow these precautions can result in equipment damage. Initial power-up Step : Connect the line supply. - The braking unit is ready to operate after approximately s. Step 2: Check that the braking unit is ready to be used. - If the green LED only is on, the braking unit is ready to be used. - If all the other LEDs are also on, as well as the green LED, there is interference. Eliminate the interference before starting up (See section: Troubleshooting, page 36). Step 3: Check that the drive is ready to be started up. - Proceed in accordance with the drive manual. 33
34 Configuration The configuration of the jumpers provides various control possibilities and different internal functions in accordance with the specific error messages. Various definitions resulting from the specific configuration possibilities of the jumpers are explained in the following paragraphs. "Autostart" Jumper J closed: Autostart. Autostart means that the device starts automatically one second after being connected to the line supply ("automatic power-up"). Configuration of the jumpers, see the table below. If the braking unit must not start up automatically, even if the phase control is deactivated, terminals 7 and 8 must be linked until 4 seconds after power-up. Then, to activate braking there must be a short pulse on the RESET input. "Power-up" - "Stop" "Stop" means that the control of the semi-conductors and the braking unit will be interrupted. It is no longer possible to brake the frequency inverter with the braking unit. "Power-up" is the activation of the control of the semi-conductors. "Memorize" The braking unit has a fault memory in which special faults can be assigned. Memorized error messages must be deleted using RESET or by breaking the line supply. "Memorize" always results in a stop and tripping of the general fault relay. "RESET" When a fault has been deleted, if it was memorized, it must be reset to zero: Either by pressing the RESET button Or by disconnecting and reconnecting the line supply (three phase). "Phase loss" RISKS OF INTERFERENCE CAUTION Resetting to zero in the case of excessive DC bus voltage during generation is not recommended. If this is performed, the power semi-conductors are exposed to increased stress, which can result in accelerated aging. Failure to follow this precaution can result in equipment damage. Phase loss supervision monitors the 3 phases of the line supply. If one phase fails, the braking unit continues to operate, but with reduced generated power. The braking unit reacts in different ways when there is a phase loss. One possibility is "two phase operation". The other is to allow the system to exit operation and the general fault relay indicates the fault. Configuration using the jumpers, see the table below: Jumper open Jumper closed X Jumper in either position J3 J5 J6 J7 Phase loss supervision Sensitive, fault memory ON Not sensitive, fault memory ON X X Stop, fault memory ON X X Stop, fault memory OFF Note: Fault memory "ON" means that the "phase loss" fault is indicated by an LED until it is cleared, if the fault no longer exists. Fault memory "OFF" means that the "phase loss" fault is indicated by an LED only as long as the fault exists. 34
35 Configuration "Overvoltage supervision" CAUTION RISKS OF INTERFERENCE Jumper J3 can only be removed after the frequency inverter or the braking unit has been turned off if the line supply has been cut-off by opening the series switches (contactors, line supply switch, etc). To avoid a dangerous voltage rise in the devices located in the section that is not powered up: power generation must be stopped. Jumper J3 must always be removed before removing jumper J7. If not, if phase loss supervision is active, the "phase loss" fault remains displayed as long as it exists (it is not memorized in the fault memory). Failure to follow these precautions can result in equipment damage. The braking module has overvoltage supervision for the line supply, which stops the device if the voltage level is greater than.5 x UN. Fault code 3 will be shown as the error message (See the "LED messages", Troubleshooting, page 36). To differentiate between phase loss and overvoltage error messages you can deactivate phase loss supervision by removing jumper 3 from the control card. If, after doing so, there is a stop with indication via the red and yellow LEDs (fault code 3), this will then be due to an overvoltage. J3 J5 J6 J7 J8 LED message Assessment (overvoltage) _ X X Green.Red Yellow Overvoltage and/or phase loss/switching fault _ X X _ Green _ Yellow Overvoltage X X Green.Red Yellow Overvoltage and/or phase loss/switching fault X X _ Green _ Yellow Overvoltage X X _ Green.Red Yellow Constant phase loss Jumper open Jumper closed X Jumper in either position Standard adjustment of the device: Autostart and no stop in the case of phase loss 35
36 Troubleshooting The 4 LEDs on the cover of the braking unit display the operating conditions. For simplified display during operation and the first time the unit is turned on, similar LEDs are placed on the control card. The orange and green LEDs are separate on the control card, while there is a two-color LED (green/orange) on the cover. RISKS OF INTERFERENCE CAUTION If the braking unit trips during a slow-down, it must not be reset to zero before the end of the slow-down, or before the DC bus voltage has fallen to a normal value. To avoid any problems, you can block the release of the inverter pulse by connecting the general fault relay contact on the braking unit to the corresponding connection on the frequency inverter. Failure to follow these precautions can result in equipment damage. Tripping on VCE: The braking unit trips via the VCE protection circuit, if the specific maximum current of the device is exceeded. The principle of this protection circuit means that for a short time (less than a millisecond), the IGBT is subjected to stress beyond its specifications for normal operation. In an exceptional case this is no problem for the braking unit. However, if there are frequent or periodic current surges at braking voltage, the high power semi-conductors will age rapidly and become prematurely faulty. The cause of periodic tripping on VCE may be an overload, a fall in line voltage, an oscillating or faulty drive, an oscillating input reference or poor design of the equipment. LED messages LED display Assessment LED display fault code Operati on Phase loss VCE Overheatin g Fault First start (after approx. s) During operation green red red orange yellow X Ready to operate System in operation 2 X Ready to operate, but no power generated check the DC fuse 3 X X X Heatsink overheating error message cannot be reset to zero while overheating continues 4 X X Fault code 3 the heatsink temperature has fallen to normal and the fault can be reset to zero 5 X X The system has stopped, (external OFF) reset to zero required The system has stopped, (external OFF) reset to zero required 6 X X An overvoltage has been detected (J8 closed) => a reset to zero is required when the grid voltage falls to its nominal value 7 X X X Incorrect phase rotation direction or a phase missing. Phase loss detected => reset required 8 X X X Overcurrent detected => reset required 9 X X X X Faults 7 and 8 Overcurrent and phase loss detected simultaneously X X X X X Several faults have been detected simultaneously Several faults have been detected simultaneously System stopped, at least 2 phases missing System stopped, at least 2 phases missing 2 X X Trip-I2t => reset required 3 X X Voltage drop during switching but no trip, while jumpers 3 and 7 are open (See the Configuration, page 34) => operation possible, improvement of the line voltage recommended. 36
37 37
38 atv7_regen_units_en_v 25-6
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
Cable Solutions for Servo and Variable Frequency Drives (VFD)
Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
A1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Specification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.
7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1
No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------
VLT Series 3500 Adjustable Frequency Drive Instruction Manual
Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies
Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
Ordering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors
ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants Installation instructions Contents Key points of installation Before installation Installation Installation check
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
MODEL 2202IQ (1991-MSRP $549.00)
F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W
T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a
Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors
APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
How To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 [email protected] www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND S 1.1 Levels of hazard
Variable speed drives for synchronous and asynchronous motors
Imptant infmation Altivar XXXXXX Variable speed drives f synchronous and asynchronous mots ATEX manual F ATEX applications in explosive gas atmosphere in the presence of combustible dust 0/010 S1A0 www.schneider-electric.com
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw
Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008
CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand
7. Reactive energy compensation
593 7. Reactive energy compensation 594 7. REACTIVE ENERGY COMPENSATION Reactive energy compensation is an important element for reducing the electricity bill and improving the quality of the electrical
PowerFlex Dynamic Braking Resistor Calculator
Application Technique PowerFlex Dynamic Braking Resistor Calculator Catalog Numbers 20A, 20B, 20F, 20G, 22A, 22B Important User Information Solid-state equipment has operational characteristics differing
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
7 - Phaseo power supplies and transformers
/0 Contents 0 - Phaseo power supplies and transformers Selection guide: Phaseo power supplies Modular, Optimum and universal ranges........................ page /2 Selection guide: Phaseo power supplies
PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03
PRO370D 65A Mbus MID DIN rail three phase four wire energy meter User manual Version 1.03 1 Safety instructions... 3 2 Foreword... 4 3 CE certificates... 5 4 MID certificate... 7 5 Performance criteria...
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Analog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
How To Understand The Electrical Power Supply Of A Power Supply System
17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder