Powering Datacenter Transformation. Uptime Institute Tier classification Lars-H. Thom 09/2013



Similar documents
Architecture for Modular Data Centers. It is all about tailoring the most optimized solution, and be able to prove it for you.

AIRAH Presentation April 30 th 2014

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

How to Build a Data Centre Cooling Budget. Ian Cathcart

State of the Art Energy Efficient Data Centre Air Conditioning

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Data Center Cooling & Air Flow Management. Arnold Murphy, CDCEP, CDCAP March 3, 2015

Managing Data Centre Heat Issues

Elements of Energy Efficiency in Data Centre Cooling Architecture

How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

STULZ Water-Side Economizer Solutions

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Legacy Data Centres Upgrading the cooling capabilities What are the options?

FEAR Model - Review Cell Module Block

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Microsoft Technology Center: Philadelphia

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Dealing with Thermal Issues in Data Center Universal Aisle Containment

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Technical Systems. Helen Bedford

European Code of Conduct for Data Centre. Presentation of the Awards 2014

European Code of Conduct for Data Centre. Presentation of the Awards 2016

The Benefits of Supply Air Temperature Control in the Data Centre

University of St Andrews. Energy Efficient Data Centre Cooling

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Precision Cooling for Business-Critical Continuity. Liebert PCW. Cool the Cloud

Direct Fresh Air Free Cooling of Data Centres

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Center. September 2013

DataCenter 2020: first results for energy-optimization at existing data centers

BICSInews. plus. july/august Industrial-grade Infrastructure. + I Say Bonding, You Say Grounding + Data Center Containment.

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Case Study: Guaranteed efficiency through standardised data centres

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Green Data Centre Design

Data Centre Cooling Air Performance Metrics

An Introduction to Cold Aisle Containment Systems in the Data Centre

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Improving Data Center Energy Efficiency Through Environmental Optimization

Greening Data Centers

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Top 5 Trends in Data Center Energy Efficiency

Engineers Ireland Cost of Data Centre Operation/Ownership. 14 th March, 2013 Robert Bath Digital Realty

AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers

The Effect of Data Centre Environment on IT Reliability & Energy Consumption

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Reducing Data Center Energy Consumption

Data Center Cooling Critical Facility & Infrastructure Optimization. Presented by. Greg Stover SVP NER Data Corporation

In Row Cooling Options for High Density IT Applications

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

DataCenter Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation.

Data Center Temperature Rise During a Cooling System Outage

Data Center Temperature Rise During a Cooling System Outage

Server Room Thermal Assessment

Data Centre. Flexible, high efficiency cooling solutions. CONDITIONING CONDENSING UNITS CONTROLS SERVICE TRAINING

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Specialty Environment Design Mission Critical Facilities

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

White Paper Rack climate control in data centres

Data Centre. Flexible, high efficiency cooling solutions. CONDITIONING CONDENSING UNITS CONTROLS SERVICE TRAINING

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

THE WORLD S MOST EFFICIENT DATA CENTER

The New Data Center Cooling Paradigm The Tiered Approach

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

Great Lakes Data Room Case Study

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

CRAC Precision climate control units for data centres

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

National Grid Your Partner in Energy Solutions

News in Data Center Cooling

Data Center Technology: Physical Infrastructure

Trends in Data Center Design ASHRAE Leads the Way to Large Energy Savings

Airflow Simulation Solves Data Centre Cooling Problem

- White Paper - Data Centre Cooling. Best Practice

How To Find A Sweet Spot Operating Temperature For A Data Center

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Data Center Components Overview

Transcription:

Powering Datacenter Transformation

נעים להכיר יגאל שניידר B.Sc.EE, MBA מנכ"ל אלכסנדר שניידר www.datacenter.org.il www.schneider.co.il בלוג: אתר:

Alexander Schneider Ltd. לאפשר ללקוחותינו לבנות ולהפעיל מרכזי מחשוב עמידים האנרגיה. )Resilient( ויעילים בצריכת מאז +100 עובדים,1963 משרדים בישראל ובארה"ב

- צמיחה מעריכית בתעבורת ואחסון נתונים Big Data משנה את פני הדאטה סהטר

14 years of exponential data growth 690 TB/month in 2001 578,000 TB/month in 2014 Information generation 2009 = 50GB/s 2020 = 500GB/µs 10,000,000x increase 840x

PUE = Power Utilization Effectiveness

חשבון החשמל השנתי בש"ח כפונקציה של גודל החדר והיעילות האנרגטית Size KW IT PUE=3 מאוד באנרגיה PUE=2.5 PUE=2 PUE=1.5 יעיל אנרגטית בזבזני Δ x 20 בעשרים שנה Mini 200KW 2,628,000 2,190,000 1,752,000 1,314,000 26,280,000 Med 500KW 6,570,000 5,475,000 4,380,000 3,285,000 66,700,000 Large 1 MW 13,140,000 10,950,000 8,760,000 6,750,000 131,400,000 V. Large 3 MW 39,420,000 32,850,000 26,280,000 19,710,000 394,000,000 קווט"ש = 50 אג '

PUE Affects Your Overall CAPEX Too IT Load 500 KW 500 KW 500 KW PUE 1.5 2.0 2.5 Total Load 750 KW 1,000 KW 1,250 KW Load + power Factor 800 KW 1,065 KW 1,330 KW Redundancy 2N 2 2 2 Base Infrastructure 1,600 KW 2,130 KW 2,660 KW Added infrastructure due to 530 KW 1,060 KW inefficiency (+ 33%) (+ 66%)

מרבית הבזבוז היא במיזוג אוויר

מסקנות ביניים צריכת החשמל של מרכזי המחשוב היא המרכיב המשמעותי ביותר בעלות הכוללת היעילות האנרגטית משפיעה מאוד גם על הוצאות התפעול וגם על ההשקעה ההקמה מרבית מרכזי המחשוב בישראל אינם יעילים אנרגטית באופן בולט מרבית הבזבוז היא במיזוג אוויר צריכת החשמל של חוות השרתים גדלה ב 70% כל 5 שנים

ASHRAE* American Society of Heating, Refrigerating & Air Conditioning Engineers ASHRAE משנה את חוקי התכנון... ASHRAE* defines different working ranges for temperature and humidity based upon installation and technology. This graph shows ASHRAE typical representation of pre-defined working envelopes.

ASHRAE הרחיב את מעטפת הטמפרטורה והלחות לחיסכון באנרגיה Typical Application: Legacy DC with Return Control and High Precision on Humidity Hardware: All Servers Temperature & Humidity: 20 C 25 C 40% 55% RH Emerson Network Power wants to answer all the different customers needs and applications Typical Application: Current DC with Return or Supply Control and Humidity Control Hardware: All Servers Temperature & Humidity: 18 C 27 C 5,5DP 60% RH&15DP

ASHRAE הרחיב את מעטפת הטמפרטורה והלחות לחיסכון באנרגיה Typical Application: Legacy DC with Return Control and High Precision on Humidity Hardware: All Servers Temperature & Humidity: 20 C 25 C 40% 55% RH Typical Application: Data Center with focus on Energy Savings and enlarged limits on Humidity Hardware: Enterprise servers, storage products Temperature & Humidity: 15 C 32 C 20% 80% RH Emerson Network Power wants to answer all the different customers needs and applications Typical Application: Current DC with Return or Supply Control and Humidity Control Hardware: All Servers Temperature & Humidity: 18 C 27 C 5,5DP 60% RH&15DP Typical Application: Information and Technology Space or Office Hardware: Volume servers, storage products, pc, workstations Temperature & Humidity: 10 C 35 C 20% 80% RH

Best Practices שימוש במערכות מיזוג אוויר יעילות אנרגטית העלאת טמפרטורת העבודה Cold Aisle Containment Free Cooling הסמכה מבצעית ( )Commissioning

Traditional Air Cooling Troubles 10-15 C

The First Step: Cold Aisle Containment 20-26 C

Cold Aisle Containment No Control Pressure Controlled Temperature Controlled

Next generation servers (14 th DELL) Front access only, power and comms Optimised for 27⁰C inlet temperature Fan-power c5% of server power, e.g. 15W in 300W 20⁰K delta-t, therefore hot-aisle is 47⁰C Capable of 45⁰C inlet temperature Fan-power rises ^3 to c200w so server power rises to 500W total Hot-aisle 65⁰C (system return temperature) Noise is ^5 H&S issue for large rooms

Liebert Free Cooling Chillers Fast Start Ramp Fast restart after power failure: first compressor ON after 20 seconds Freecooling with SmartAisle High water temperatures mean High Freecooling effect: high system efficiency p Cooling Range 60 1600 kw icom Control Strategies for system efficiency: Freecooling chiller teamwork and integration with Floor mounts Liebert. Complete monitoring product offer. High Efficiency Components - EC Fan - Electronic expansion valve - Scroll / Screw compressors - Pumps with efficiency class IE3

o 7-12 C, FC Chiller: 624KW @ 862KW @ 21% savings with Free Cooling feature בשנה 160,000 חיסכון של כ לפי נתוני ירושלים o 17-22 C

בדיקה והסמכה של מרכז מחשוב חדש

מאפיינים של חדרי שרתים חדשים כל מרכז מחשוב יחיד במינו ברוב המקרים, יותר מאחד המובילים העיקריים עושה תפקידו בפעם הראשונה ריבוי קבלנים / ספקים לחץ זמנים שגיאות תכן, ביצוע ומגבלות חומרה יתגלו במהלך חיי החדר קיום תקלות נסתרות שיגרמו לזמן דמימה בעתיד מרבית תקלות התשתית יתגלו עם הזמן בעקבות הגידול הטבעי בעומס

הסמכה מבצעית של חדר המחשב שימוש ב server emulator התקנת חיישנים אלחוטיים התקנת תוכנת בקרה מוקד שליטה ובטיחות תוכנית בדיקות

Real Time Heat Map

תמונה מהסמכה מבצעית של חדר מחשב בישראל

הסמכה מבצעית של חדרי מחשב הדרך האמינה ביותר להבטיח גילוי תקלות בתכן, בהתקנות ובציוד לפני הפעלה מבצעית של החדר מבחן אמת לכל מערכות חדר השרתים תחת עומס אמיתי המדמה בצורה מדויקת התנהגות שרתים וציוד IT מיזוג אוויר חשמל יתירות צריכת אנרגיה גילוי התקלות כאשר כל הקבלנים והמתכננים עדיין מחויבים ומעורבים בפרויקט וכל המערכות עדיין תחת אחריות יום אחד. ROI

Best Practices Design for Energy Effectiveness- PUE תכנון חדר המחשב חייב לתת דגש על יעילות אנרגטית להעלות את טמפרטורת העבודה )לכיוון 27( ולמקסם את טמפ' האוויר החוזר Containment Free Cooling הסמכה מבצעית ( commissioning )

Professional Services לעזרת מתכנני מיזוג אוויר ודאטה סנטר CFD ) הסמכה מבצעית ( Commissioning חוות שרתים להדגמה והדרכה תוכנה של Liebert לתכנון ואימות תכן של מיזוג אוויר ביצועי יחידות הקירור בתנאי חדר וסביבה שירות 24x7

תודה יגאל שניידר yigals@schneider.co.il