Chillers, Pumps, Motors & Electrical

Similar documents
Creating Efficient HVAC Systems

3/29/2012 INTRODUCTION HVAC BASICS

Commissioning - Construction Documents (Page 1 of 6)

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

HVAC Systems: Overview

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE

Chapter 3.4: HVAC & Refrigeration System

Drives and motors. A guide to using variable-speed drives and motors in retail environments

A Guide to Trouble-Free Cooling Towers

How Ground/Water Source Heat Pumps Work

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Chilled Water HVAC Systems

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Printing and Publishing Energy Savings Guide

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

How To Design A Refrigeration System

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

By Steven C. Severini, P.E., Member ASHRAE

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

How To Understand Evaporator

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

VACUUM REFRIGERATION SYSTEMS

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

8. Refrigeration. 4. Liquid. Refrigerant. 4. Liquid Refrigerant. Figure 8.1 Refrigeration system layout (single stage)

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Why and How we Use Capacity Control

AIR CONDITIONING TECHNOLOGY

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

10 Strategic Steps to Reducing Your Energy Costs AEE Regional Chapter Meeting February 2, 2005

IDEA Presentation SMALL CAMPUS CHILLED WATER PLANT OPTIMIZATION.

State of the Art Energy Efficient Data Centre Air Conditioning

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

Product Data Bulletin

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Glossary of Heating, Ventilation and Air Conditioning Terms

Heat Recovery In Retail Refrigeration

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

- White Paper - Data Centre Cooling. Best Practice

Impact of Control System Technologies on Industrial Energy Savings

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

ENERGY RETROFIT PROGRAM

HEATING, VENTILATION & AIR CONDITIONING

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.


Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Energy Efficiency in Industrial HVAC Systems

Wet Bulb Temperature and Its Impact on Building Performance

Closed Circuit Cooling Towers

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

MAC-120HE-01 Air-Cooled Chiller

apv heat exchanger APV ParaFlow Plate Heat Exchangers

HVAC Processes. Lecture 7

Action Plan Template HVAC Page 1

ABSTRACT. aspects of potential waste heat recovery systems and the economics of installing them at selected survey factories.

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

Glossary of HVAC Terms

CHILLED WATER PLANT PUMPING SCHEMES. James J. Nonnenmann, PE Stanley Consultants, Inc. Muscatine, Iowa

Guide to Minimizing Compressor-based Cooling in Data Centers

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

*At the AHRI Standard flow rate of 3 gpm/ton, using today s efficient chillers, the ΔT is 9.3 F rather than the 10 F often assumed.

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Training for Building Technicians: Energy Efficiency & Sustainability (BEST) Program. Seminar Outline & Sample BEST Exam Questions

Drives and motors. A guide to using variable-speed drives and motors in data centres

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Heating, Ventilation & Air Conditioning Equipment

Air Conditioning 101. STN Presentation AC101

Evaporative Cooling System for Aquacultural Production 1

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

NEW JERSEY CENTER OF EXCELLENCE

Food & Drink Industry Refrigeration Efficiency Initiative

EnergyPro Building Energy Analysis. Assisted Living Building

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Air-Conditioning Buying Guide

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Bring the fresh in. Dedicated Outside Air Systems

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

How does solar air conditioning work?

Lower Energy Costs with Rooftop Air-Conditioning Package Units

How To Clean Water From An Ammonia Refrigeration System

Transcription:

Chillers, Pumps, Motors & Electrical Alfred Woody, PE Ventilation/Energy Applications, PLLC Norton Shores, Michigan 231 798 3536

Overview System components Design considerations Things to check Waste & inefficiencies Common ECM s

Chilled Water Systems Components Chiller Cooling tower or air cooled condenser Fans Pumps Controls Coils and heat exchangers valves Distribution pipe

Chilled Water System

Refrigeration Fundamentals A refrigerant in the gas form is compressed adds heat and pressure High pressure gas is cooled in condenser and refrigerant loses heat and becomes a liquid Liquid refrigerant moves to another heat exchanger where it s pressure is dropped The low pressure refrigerant expands to a gas which takes heat from the fluid and the refrigerant becomes cold In the heat exchanger another fluid gives up heat to the cold refrigerant gas which is warmed The refrigerant gas moves on to the compressor where its pressure is increased again

Chiller Types Refrigerant compression uses motor driven compressor Reciprocating compressor Screw compressor Centrifugal compressor Absorption chiller - uses heat to dry water from an absorbing liquid, water evaporated from this liquid travels to the evaporator section where it is sprayed. As this water evaporates into this chamber it lowers the temperature and cools the chilled water circulating through it. The evaporated water is absorbed in the liquid which is pumped to the generator section. Single stage Two stage

Steam Absorption Chiller

Cooling Towers Condenser water pumped to cooling tower Cooling related to air humidity Evaporative cooling process where water temperature reduced Water should be treated for algae control Water blow-down to control dissolved solids

Cross Draft Cooling Tower

Counter Flow Cooling Tower

Typical Operating Parameters Chiller output - 45 F water, Return water 10 F to 20 F warmer Condenser water 85 F in, 95 F out Energy Use Electrical =.6 to.8 kwh/ton (average is $0.08/ton-hr @ $0.12/kWh) Absorption = 18 MBH/ton single stage ($.22/ton-hr @ $12/million Btu), 12 MBH two stage ($0.14/ton-hr @ $12/million Btu)

Design Considerations Degree of humidity control and other issues that affect supply chilled water temperatures. Electrical demand costs Systems served Constant or variable flow Seasonal & peak requirements Outside temperature and humidity Cooling tower location

Things to Check Chiller load profile data Return water temperature Cooling tower condition and temperature reduction Amount of make-up water Temperature at remote locations of distribution system

Energy Waste Chiller Systems Water flow through shut down equipment Dirty heat exchangers Uncalibrated poorly adjusted controls Cooling tower leaks and excessive blowdown Dirt distribution nozzles in cooling tower Cooling tower internal components in poor condition

Energy Waste Chiller Systems No insulation on pipes < 60 F Distribution system leaks Unbalanced flow causing excessive pressure drop through control valves Too much bypass water in circulating systems

Energy Inefficiencies Chiller Systems Use of air cooled condensers Use of oversized equipment Constant chilled water temperature Constant condenser water temperature Blowdown from tower basin

Energy Inefficiencies Chiller Systems No duct at fan discharge for velocity pressure recovery No adjustment of fan blades for load or season High pressure pumps instead of booster pump use Variable flows with constant speed pumps

ECM Raise Chilled Water Temperature Raising the leaving chilled water temperature increases the performance efficiency Could be combined with DOAS units having DX cooling Lowers distribution energy losses

ECM Lower Condenser Water Temperatures lowering the incoming condenser water temperature improves the chiller efficiency Can vary by weather conditions Will cause cooling tower energy to increase Can set up chillers controls to optimize energy use of system

ECM Isolate Off-line Chillers During low cooling loads when only one chiller needs to operate, the system design has chilled water flowing through all chillers causing multiple pumps to operate and the dilution of the chilled water temperature. Wastes pump Hp and requires lower chilled water temperatures. Install new pipe and valves to allow individual chillers and cooling towers to operate isolated from others. New pumps may also be required.

ECM Replace Air Cooled Condensers with Cooling Towers Air cooled condensers normally operate at a temperature difference of 20 F higher than the outdoor temperature. Cooling towers perform at 10 F above the wet bulb temperature which can be more than 20 F lower than the dry bulb temperature. The result the chiller s condensing temperature could be more than 15 F lower with a cooling tower which has a dramatic effect on chiller performance.

ECM Thermal Storage Systems Best done during addition to central chilled water system Cost of storage tank less than new chillers Reduces electrical demand charges Can be chilled water or ice storage

Thermal Storage Optimizing Chillers

Pumps Rotating impeller in housing causes water flow Flow rates changed by Changing pumps Shaving impeller Using variable speed motor Placement important need some water pressure on pump for proper operation

Pumping Energy Waste Use of excessive valving to balance flow Failure to adjust pump for correct flow during system balance pumps larger than 10 Hp Failure to use booster pumps when a portion of distribution systems requires an 20 % increase in pressure

ECM Utilize Variable Flow Distribution Requires two way valves at point of use May require primary/secondary pumping system since chillers have a low limit for flow. Achieves savings in pumping horsepower Utilizes full temperature rise of system design

Electrical Distribution Components Transformers High voltage switch gear Power distribution lines Motors

Electrical Distribution Design Considerations Building/Area electrical loads Length of distribution Equipment voltage requirements Need for back-up power

Things to Check Change in building function since transformer selection Use of standard or high efficiency motors Charge for poor power factor by electrical utility company

Energy Waste - Electrical Distribution Oversized transformers Energized transformers in unused buildings Transformer taps not set at proper setting

Energy Inefficiency - Electrical Distribution Power factor less than 85% Use of non premium efficiency motors

ECM Replace Lightly Loaded Transformers Electrical transformers are up to 98 % efficient and thus there are losses in electrical energy even when the equipment being served is switched off. Lightly loaded transformers should be replaced with an high efficient one that is sized for the current load. Select the transformer with the lowest temperature rating

ECM Power Factor Correction Poor power factor increases losses in the electrical distribution lines, transformers and motors It is caused by lightly loaded and inefficient motors Install properly sized motors Control power factor by placing capacitors before problem equipment

ECM Utilize Premium Efficiency Motors vs. Standard Efficiency Motors Comparison with standard efficiency motors with replacement upon failure Electrical cost = $0.055/kWh Motor Size Existing Efficiency (%) Proposed Efficiency (%) Energy Saved (kwh/yr) Energy Cost Savings ($/yr) Total Cost Premium ($) Additional Cost of New Motor vs. Rewinding Simple Payback (yrs) 25 88.00% 93.60% 9,149 $503 $1,115 $558 1.1 20 87.50% 93.60% 7,973 $438 $985 $493 1.1 15 86.00% 93.00% 6,862 $377 $790 $395 1.0 10 85.00% 91.70% 4,378 $241 $590 $295 1.2 7.5 84.00% 91.00% 3,431 $189 $486 $243 1.3 5 82.00% 89.50% 2,451 $135 $356 $178 1.3 3 80.00% 89.50% 1,862 $102 $269 $135 1.3 2 77.00% 86.50% 1,242 $68 $274 $137 2.0 1 73.00% 85.50% 817 $45 $213 $107 2.4

ECM Utilize Premium Efficiency Motors vs. High Efficiency Motors Comparison with post 1997 high efficiency motors with replacement upon failure Electrical cost = $0.055/kWh Motor Size Existing Efficiency (%) Proposed Efficiency (%) Energy Saved (kwh/yr) Energy Cost Savings ($/yr) Total Cost Premium ($) Additional Cost of New Motor vs. Rewinding Simple Payback (yrs) 25 91.70% 93.60% 3,104 $171 $1,115 $558 3.3 20 91.00% 93.60% 3,398 $187 $985 $493 2.6 15 91.00% 93.00% 1,960 $108 $790 $395 3.7 10 89.50% 91.70% 1,438 $79 $590 $295 3.7 7.5 88.50% 91.00% 1,225 $67 $486 $243 3.6 5 87.50% 89.50% 653 $36 $356 $178 5.0 3 86.50% 89.70% 627 $35 $269 $135 3.9 2 84.00% 86.50% 327 $18 $274 $137 7.6 1 82.50% 85.50% 196 $11 $213 $107 9.9

ECM Install EMCS Central control and optimization of HVAC systems Remote monitoring and evaluation of system performance Maintenance aid and problem anticipation Electrical demand monitoring and control Need to actively use and adopt as a tool for full benefits

ECM - Replace Lightly Loaded Motors Look for systems that have had loads reduced Reduced loads on motors result in poor power factors and inefficiencies Measure motor amps and compare to full load current on nameplate Replace motors loaded less than 60% of rating

Thank You Questions?