Operating manual PTC-resistor relay MSF 220 V (VU)

Similar documents
Safety technique. Emergency stop module BO 5988 safemaster

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

HERZ-Thermal Actuators

Thermistor motor protection

PHOENIX CONTACT Features

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Quick Connect. quick - simple - efficient.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

instabus KNX / EIB System System E F G H

ACS-30-EU-EMDR-10-MOD

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Drayton Digistat +2RF/+3RF

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Product and functional description

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

TMS TANK MANAGEMENT SYSTEM

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Safety Relays ESM/ESM-F

J TB/TW Temperature limiter, temperature monitor

Power Supplies 3. SDN-P DIN Rail Series

48 SERIES Relay interface modules 10 A

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

RY2 miniature industrial relays

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Type: DILM9 10(24VDC) Article No.:

E-STOP relays, safety gate monitors

Modular I/O System Analog and Digital Interface Modules

Type: DILM32 10(24V50HZ) Article No.:

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

ADM1TE 5/30A DIN rail single phase two wire energy meter

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Three-phase monitoring relay CM-PFE

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Pluggable interface relays CR-P Pcb relays

User s Manual Before using the inverter, you need to read and save the safety instructions.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

80 Series - Modular timers 16 A. Features

MINI MCR-SL-R-UI(-SP)

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

SKR - industry relay

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

SX460. Generator Automatic Voltage Regulator Operation Manual

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Preset Counter signo 721

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Technicaldata General

Safety automation solutions

13 SERIES. Electronic step relays A

650W Single Output Power Supply

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

RM4TG20 three-phase network control relay RM4-T - range V

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

PNOZsigma - Base units

DALI RC BASIC SO. Control unit Operating instructions

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

60 Series - General purpose relays 6-10 A. Features

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

MCR1900 Media Converter 19-Slot Chassis

40 Series - Miniature PCB/Plug-in relays A. Features

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Thyristor-controlled power supplies and battery chargers

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Cross-beam scanning system to detect slim objects. 100 mm in

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Contact expansion modules

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5

E-STOP relays, safety gate monitors

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

38 Series - Relay interface modules A

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Vario-Series Accessories

Transcription:

MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay MSF 220 V (VU) Page 1 of 8

Contents Page Application and short description... 3 Overview of functions and connection plan... 3 Detailed description... 4 Table of functions:... 4 Assembly... 5 Putting into operation... 5 Trouble shooting... 6 Technical data... 7 Form... 8 Page 2 of 8

PTC Alarm 2 PTC Alarm 1 PTC Fan Alarm 2 Alarm 1 Fan/Al 1 Application and short description The MSF 220 V is particularly suitable for the temperature monitoring at dry transformers. 3 PTC-circuits with different nominal response temperatures (NRT) can be connected to this unit, one for controlling a fan (forced cooling) and two for alarms. Each PTC-circuit is monitored for break and short circuit. This reduces the probability of false alarms. Overview of functions and connection plan 3 PTC-circuits MSF 220 VU for universal supply voltage AC/DC 24-240 V intelligent control of fan (relay K0, 1 normally-open contact) ALARM 1 in closed-circuit current mode (relay K1, 1 change-over contact) for pre alarm. Signals also error in any sensor and interruption of supply voltage. ALARM 2 in operation current mode (relay K2, 1 changeover contact). No signal when switching on and off the supply voltage. all output relays potentially separated from each other. monitoring of sensor lines TEST-button (stop possible before ALARM 2) Simply test function, sensor monitoring can be disengaged (for 10 minutes) LEDs for ON, sensor error, Fan, ALARM 1 and ALARM 2 plug-in terminals housing for mounting on DIN-rail or wall-mount mounting height 55 mm Application with fan: N L1 AC: L1 N DC: L+ L- M Lüfter / Fan A1 A2 24 21 22 14 11 12 08 05 K2 T T2 T1 T0 T K1 K0 Page 3 of 8

PTC Alarm 2 PTC Alarm 1 R Alarm 2 Alarm 1 Fan/Al 1 Application without fan: AC: L1 N DC: L+ L- A1 A2 24 21 22 14 11 12 08 05 K2 T T2 T1 T0 T K1 K0 Detailed description The PTC-relay MSF 220 V has been designed for monitoring the temperature of drytransformers. 3 PTC-circuits with different nominal-response-temperatures (NRT) can be connected to this unit, one for controlling a fan (forced cooling) and two for alarms. Each PTC-circuit is monitored for break and short circuit. This reduces the probability of false alarms. Table of functions: IN OUT LED FAN / Alarm 1 Alarm 1 Alarm 2 FAN Alarm 1 Alarm 2 Sensor ON contact 05-08 11-12 21-24 Power OFF 0 1 0 0 0 0 0 0 Power ON 2 s 2 s 2 s 2 s 1 Sensor 0 normal 0 0/ 0 1 Flash* ( T / T0 ) overload 1* 1 0 1 0 / 1 Flash 1 1 Sensor 1 normal 0 0 0 1 ( T / T1 ) overload 1 1 1 1 0 1 0 / 1 Flash 1 1 Sensor 2 normal 0 0 0 1 ( T / T2 ) overload 1 1 0 1 0 / 1 0 ( 1 ) Flash 1 1 * = delayed switch back 20-60 min. ( rückschaltverzögert 20-60 min. ) LEDs Alarm 1 and Alarm 2 flash until Reset ( blinken bis zu einem Reset oder Spannungsunterbrechung ) Test: LED "ON" -flash -> +2 s -> FAN -> +3 s -> Alarm 1 -> +3s -> Alarm 2 -> +7 s -> Test 2 (0 / ) Interrupt on release ( Abbruch bei Loslassening ) Page 4 of 8

Assembly Mount on 35 mm mounting rail EN 60715 or Wall mounting with screws M4 Putting into operation Connect wires as per connection plan DANGER! Hazardous voltage! Will cause death or serious injury. Turn off and lock out all power supplying this device before working on this device. When installing the device into the switch-gear cabinet, please observe the max. admissible temperature. Care for both, sufficient clearance to other devices or sources of heat or enough forced draught.! Attention! Before switching on make sure that the supply voltage Us of the type plate and the mains voltage are the same! Apply mains voltage to terminals, AC to A1 and A2 (DC A1=+, A2=-). When device is ready for operation, relays K1 picks up (contact 11-14 closes), the green LED "ON" is alight.! In case of failure of supply voltage, the monitored unit is not protected any more. The operator must ensure, that a failure is detected, e.g. by monitoring Alarm 1 (K1) or by testing the unit regularly. Even if no temperature warning is monitored with alarm 1, the function of the relay K1 has to be evaluated, otherwise the monitoring can fail unnoticed (missing supply- voltage, equipment failure etc.). When no sensor is connected to T/T1, a resistor (100Ω 1000Ω) must be mounted. Page 5 of 8

Trouble shooting LED "ON" is not alight Make sure that supply voltage is connected correctly (+/-) to terminals A1/A2 and is the same as on the type plate LEDs FAN, ALARM 1 or ALARM 2 flash, LED SENSOR light up and relay K1 doesn t pick up: Check the PTC-sensors. Make sure they are connected correctly to T0, T1 and T2. All PTC must have a low resistance (pay attention to monitoring sensor-break and shortcircuit; when using without fan a resistor 100... 1000 ohm in T/T0 is required) Testing the outputs can easily be realized by using the test-button (keep pressed). If no PTC resistors are connected, the relay K1 always signals an alarm For testing the PTC-input, the resistance has to be increased slowly, i.e. by means of a potentiometer (app. 10 kω). Rapid changes may be detected as sensor-error. During normal operation testing the function with a short circuit in the sensorinput and/or by disconnecting the sensors (interrupt) is not possible. Any manipulation will result in detecting a sensor-error (K1 releases and a sensor-error is displayed, K0 and K2 do not switch) Test with interrupt and short circuit at the sensor-inputs is possible in test function 2. Press Reset/Test-button until LED "ON" flashes rhythmically (approx. 15 s). The device will return to normal operation when pressing Set/Reset or automatically after 15 minutes. Attention! Check PTC s only with measuring voltages < 2.5 V. In case of any other malfunctions, replace device and send it in together with a description of the occurred problem. Page 6 of 8

Technical data Type MSF 220 V MSF 220 VU Order number T 221738 T 221737 Supply voltage/frequency Us AC 220-240V 50/60 Hz AC/DC 24 240 V Power consumption P < 3 VA P < 5 VA < 2 W Tolerance voltage Us AC 0.9...1.1 Us AC/DC 20 270 V Tolerance frequency Us 48...62Hz 40 70 Hz PTC-resistor connection Cut-out point Reclosing point Collective resistance of cold sensors Short-circuit monitoring Terminal voltage (sensors) Terminal current (sensor) 3 x 1...6 PTC in series 3.3...4.0 kω, typ. 3.65 kω 1.5...1.65 kω, typ. 1.6 kω 1.5 kω R min > 40 Ω, R k = 20 40 Ω 2.5 V at 250 Ω 5 V at 4 kω 2 ma Relay output K1 and K2 = 1co potential free K0 = 1no potential free Switching voltage max. AC 415 V Switching current max. AC 6 A Switching power max. AC 2000 VA 120 W at DC 24 V Rated operational current Ie AC15: I e = 2A, U e = 400 V I e = 3 A, U e = 250 V DC13: I e = 2A, U e = 24 V Mechanical contact life 3 x 10 7 operations Electrical contact life 1 x 10 5 operations (at 230 V / 6 A) Factor of reduction at cos 0.3 0.5 x max. switching capacity Fuse for device and contacts 4 A, time-lag (gl) Testing conditions EN 50178 / EN 60947 Rated insulation voltage AC 300 V Contamination level 2 Overvoltage category III Rated impulse voltage 4000 V EMC EN 61000-6-2 / EN 61000-6-3 On period 100 % max. ambient temperature -20... +60 C / -20 +70 C Housing: design V4 Mounting height / Width 55 mm / 4 TE Dimensions (H x W x D) 90 x 70 x 58 mm Material Polyamide PA 66, UL 94 V-2 Protection housing/contacts IP 30 / IP 20 Line connection solid wire 1 x 0.5... 1.5 mm2 Stranded wire with insulated ferrules 1 x 0.14 mm2 1 mm2 Mounting snap able on 35 mm standard rail according to EN 60715 or assembly with screws M 4 Weight app. 250 g Subject to technical modifications Page 7 of 8

3 61,8 45 (90) 116 98 Form V4 dimensions in mm 58 48 16,5 70 Option 5 4 1 2 3 6 7 1 Upper part 2 Lower part 3 Bar for snap mounting 4 Latch for sealing 5 Front panel 6 Position downward 7 Bar for fixing to wall with screws, Ø 4.2 mm Page 8 of 8