AC1036. Definite Purpose Contactors

Similar documents
General Purpose Relays Types K, R, N, and C

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

D-Line Contactors, Overload Relays and Accessories

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

How To Protect A Motor From Overcurrent

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Catalog. Modular DIN rail components Installation contactors

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

CQM1-SF200/CS1W-SF200

49 Series - Relay interface modules A. Features

Catalog January. Heavy industrial power applications Motor contactors and starters

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

AZ420 MINIATURE GENERAL PURPOSE RELAY

Manual motor starter MS116

Softstarters Type PSR

Relays and Timers Specifications Bulletin Number 700

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

48 SERIES Relay interface modules 10 A

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

Technical catalogue. Modular DIN rail components Installation contactors

Z-TRAUQ INC. Tel.: (450) Fax: (450)

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

Type: DILM32 10(24V50HZ) Article No.:

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CompactLogix Power Supplies Specifications

38 Series - Relay interface modules A

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Type: DILM50(230V50HZ,240V60HZ) Article No.:

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Definite Purpose Contactors and Starters

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Goodsky Technical Data. Contact Details

CATALOG #250

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

38 Series - Relay interface modules A

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Three-phase monitoring relay CM-PFE

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Tmax MCCBs. Molded case circuit breakers. Tmax

Bulletin 1489 Circuit Breakers. Selection Guide

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

2S-Series Sub-Miniature Toggle Switches

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Relés e Contatores de Estado Sólido SIRIUS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Type: DILM9 10(24VDC) Article No.:

MCR1900 Media Converter 19-Slot Chassis

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

8146/5 Series Breaker Panelboards

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Owner's/Installation Manual

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

TorqPlus TM Electric Valve Actuators and Controls

Technicaldata General

PSR The compact range Description

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Industrial Control Power Transformers

SKR - industry relay

Power Supplies 3. SDN-P DIN Rail Series

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Circuit Breakers. NRC Series. NRC Series

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

General-purpose Relay

Electronic overload relay EF65, EF96 and EF146

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MasterINTERFACE 39 Series - Relay interface modules

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection

RM4TG20 three-phase network control relay RM4-T - range V

Transcription:

Definite Purpose Contactors

Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines Resistive heating Air conditioning Refrigeration equipment Welding Agency approvals UL 508 Guide No. NLDX2, File # E224401 CSA C22.2 No. 14, NLDX8 File No. E224401 CE/Semko Certified, EN60947-4-1:1991 IEC 947-4-1 Catalog number explanation Definite purpose Frame size 20 = 20A 25 = 25A 30 = 30A 40 = 40A 50 = 50A 60 = 60A 75 = 75A 90 = 90A DP 30 C 3P - 1 Features Available as: 20A, 25A,1, 2 or 3 pole 30A, 1, 2, 3 or 4 pole 40A, 2, 3 or 4 pole 50A, 60A, 75A, 90A, 3 pole Industry standard mounting plate provides easily accessible mounting holes Coil terminals are provided with #6-32 screws and (1).250 quick connect or dual.250 quick connect terminals Exclusive hex, slotted, phillips #10-32 terminal screws for main terminals Coil is class B (130 C) insulation system with wide range of voltages and 50/60 Hz ratings Double E magnet assembly provides optimal performance with reduced power consumption Snap-in auxiliary switch with 1 SPDT or 2 SPDT contacts available as an option 1 N.O. & 1 N.C. auxiliary contact block with 600 VAC rating available as an option Base assembly is made from high arc-resistant polyester Coil voltage (See coil voltage selection chart) Power poles 1P = 1 N.O. 2P = 2 N.O. 3P = 3 N.O. 4P = 4 N.O. Contactor type C = Non-reversing R = Reversing This catalog is published for information purposes only and is not all inclusive. All dimensions are approximate. For additional information on products or technical information, consult ABB. The installation and use of ABB products should be in accordance with the provisions of the Canadian Electrical Code and/or other local codes or industry standards that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous to personnel and/or equipment.

Definite purpose contactors 20A... 90A DP30C2P-1 DP40C4P-1 DP60C3P-1 DP75C3P-1 20A, 25A, 30A, 40A, 50A, 60A, 75A & 90A Locked rotor amps Maximum HP Maximum HP Full Number 1 phase 3 phase Standard Catalog List load of 240/ Resistive 200/ 240/ pack number price amps poles 277V 480V 600V amps 120V 240V 208V 277V 480V 600V qty. 20 1 120 100 80 30 1 2 50 DP20C1P-1 20 2 120 100 80 30 1 2 50 DP20C2P-1 20 3 120 100 80 30 1.5 3 7.5 7.5 7.5 7.5 25 DP20C3P-1 25 1 150 125 100 35 1 2 50 DP25C1P-1 25 2 150 125 100 35 1 2 50 DP25C2P-1 25 3 150 125 100 35 2 5 10 10 15 20 25 DP25C3P-1 30 1 150 125 100 40 1 2 50 DP30C1P-1 30 2 150 125 100 40 2 3 50 DP30C2P-1 30 3 180 150 120 40 2 5 10 10 15 20 25 DP30C3P-1 30 4 180 150 120 40 2 5 10 10 10 25 DP30C4P-1 40 2 200 160 120 50 2 3 50 DP40C2P-1 40 3 240 200 160 50 3 7.5 10 10 20 25 25 DP40C3P-1 40 4 240 200 160 50 3 7.5 10 10 10 25 DP40C4P-1 50 3 300 250 200 65 3 10 15 15 25 25 25 DP50C3P-1 60 3 360 300 240 75 5 10 20 25 30 30 25 DP60C3P-1 75 3 450 375 300 93 5 15 20 25 40 40 5 DP75C3P-1 90 3 540 450 360 120 7.5 20 25 30 50 50 5 DP90C3P-1 Coil voltage selection chart Voltage 24VAC 120VAC 208/240VAC 277VAC Suffix # F 1 2 C Coil voltage selection All catalog numbers include a 120VAC coil. To select other coil voltages, substitute the code from the coil voltage selection chart for the first digit after the dash in the catalog number. Auxiliary contact blocks Catalog Catalog Catalog Catalog List Description number number number number price 20A - 40A, 3P 20A - 40A, 4P 50A - 60A 70A - 90A Form C SPDT CADP40-10 CADP40A-10 CADP60-10 CADP90-10 1 N.O. & 1 N.C. CADP40-11 CADP40A-11 CADP60-11 - Contact rating of 1 N.O. & 1 N.C. 120V 240V 480V 600V Break A 3.0 1.5.75.6 Make A 30 15 7.5 6 Continous A 10 10 10 10 Quick connect terminals on all auxiliary switches are.250 wide. Contact rating of SPDT Voltage Current rating 125VAC 10A, 1/3 HP 120VAC 4A on lamp load 250VAC 10A, 1/3 HP 125VDC.5A 250VDC.25A Discount schedule DS-DP 1

Technical data 20A - 90A 1, 2, 3, & 4 Pole 20A 40A 1 & 2 pole Coil technical data DP20...DP30C1P DP20...DP40C2P Nominal coil voltage 24 120 208/240 277 24 120 208/240 277 Maximum pickup volts 18 88 177 221 18 88 177 221 Drop-out volts range 6 15 20 70 40 170 50 165 6 15 20 70 40 140 50 165 Nominal inrush VA 50 Hz 31 31 35 31 22 22 22 22 Nominal inrush VA 60 Hz 28 28 32 28 20 20 20 20 Nominal sealed VA 50 Hz 6 6 7 6 5.5 5.5 5.5 5.5 Nominal sealed VA 60 Hz 5 5 6 5 4.5 4.5 4.5 4.5 Nominal DC resistance Ohms 17.5 450 1800 2252 13 275 1056 1772 Other specifications DP20...DP30C1P, C2P DP40C2P Line and load terminals # 10 32 screw 1 Box lug 1 Wire size AWG min max 16 8 2 14 4 Cu/Al Tightening torque (recommended) 25 in. lbs. 40 in. lbs Coil termination Dual.250 QC (2) Dual.250 QC (2) Quick connects.250 std. 1 1.5 pole Quad Quad Quick connects.250 std. 2 pole Dual or quad Dual or quad Covers Optional Standard Insulation system 130 C Class B 130 C Class B 20A- 60A 3 pole Coil technical data DP20...DP40C3P DP50...DP60C3P Nominal coil voltage 24 120 208/240 277 480 24 120 208/240 277 480 Maximum pickup volts 18 88 177 220 384 18 93 177 235 374 Drop-out volts range 6 15 20 70 40 140 65 185 150 270 6 15 20 70 40 135 50 180 150 286 Nominal inrush VA 50 Hz 65 65 65 65 65 140 140 140 140 140 Nominal inrush VA 60 Hz 60 60 60 60 60 132 132 132 132 132 Nominal sealed VA 50 Hz 7.5 7.5 7.5 7.5 7.5 20 20 20 20 20 Nominal sealed VA 60 Hz 6 6 6 6 6 14 14 14 14 14 Nominal DC resistance Ohms 6.6 165 660 880 1320 2.4 45 180 280 852 Other specifications DP20...DP30C3P DP40C3P DP50...DP60C3P Line and load terminals 1 # 10 32 Screw 1 Box lug 1 Box lug 2 Wire size AWG min max 16 8 14 4 Cu/Al 14 2 Cu/Al Tightening torque (recommended) 25 in. lbs 40 in.lbs 50 in. lbs Quick connects: power terminals Dual.250 QC Dual.250 QC Dual.250 QC Coil terminals Dual.250 QC (2) Dual.250 QC (2) #6 32 screw &.250 QC (2) Covers Optional Standard Standard Insulation system 130 C Class B 130 C Class B 130 C Class B 20A 40A 4 Pole Coil technical data Coil technical data DP75, DP90C3P DP20...DP40C4P Nominal coil voltage 24 120 208/240 277 480 Maximum pickup volts 19.2 88 177 220 384 Drop-out volts range 6 15 20 70 40 140 65 185 150 270 Nominal inrush VA 50 Hz 68 68 58 58 48 Nominal inrush VA 60 Hz 60 60 55 52 52 Nominal sealed VA 50 Hz 14 14 11 11 11 Nominal sealed VA 60 Hz 9 9 9.5 9.5 9 Nominal DC resistance Ohms 5 148 550 750 2100 Other specifications DP20...DP30C4P DP40C4P Line and load terminals # 10 32 screw 1 Box Lug 1 Wire size AWG Min Max 16 8 2 14 4 Cu/AL Tightening torque (recommended) 22 in. lbs 40 in. lbs Quick connects: power terminals Dual.250 QC Dual.250 QC Coil terminals Dual.250 QC (2) Dual.250 QC (2) Covers Optional Standard Insulation system 130 C Class B 130 C Class B 75A 90A 3 pole Nominal coil voltage 24 120 208/240 277 480 Maximum pickup volts 18 88 177 220 384 Drop-out volts range 6 15 20 70 40 110 65 185 150 270 Nominal inrush VA 50 Hz 285 285 285 285 285 Nominal inrush VA 60 Hz 240 240 240 240 240 Nominal sealed VA 50 Hz 42 42 42 42 42 Nominal sealed VA 60 Hz 27 27 27 27 27 Nominal DC resistance Ohms 0.63 15.6 63.5 84 255 Other specifications DP75, DP90C3P Line and load terminals Box Lug 1 Wire size AWG Min Max 14 1/0 Cu/AL Tightening torque (recommended) 50 in. lbs Quick connects: power terminals Dual.250 QC Coil terminals #6 32 screw.250 QC (2) Covers Standard Insulation system 130 C Class B 1 See page 5 for description and approximate dimensions. 2 Stranding must be split for #8 wire. 2

Approximate dimensions 20A, 25A, 30A 1, 2 & 3 Pole DP20...30C1P ø DP20...30C2P ø DP20...30C3P 3

Approximate dimensions 30A, 4 Pole 40A, 2 & 3 Pole DP30C4P DP40C2P ø DP40C3P 4

Approximate dimensions 40A, 4 Pole 50A, 60A, 75A, 90A, 3 Pole DP40C4P 2.75 DP50...60C3P DP75...90C3P Screw Standard on Lugs Standard on Standard on Standard on DP 20...30 DP40 DP60 DP75&90.256.32.395 5

2117, 32nd Avenue Lachine, Quebec H8T 3J1 Telephone: 514-420-3100 Toll Free: 800-567-0283 Fax: 514-420-3137 http://www.abb.ca Catalog No. printed in Canada Otc. 2007