Zenith STS-1 & STS-3 Series Static Transfer Switches. Seamless Input Source Transfers for Sensitive Critical Loads.

Similar documents
Zenith Series MDU & RDU. Critical Power Distribution Units

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

SG Series UPS kva. high efficiency systems

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

ABB PSPS Erich Steinmann; Generator control-2013

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Phase Modular Finally the benefits of Modular ups are for all

Galaxy VM. Three-phase power protection. schneider-electric.com

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

TLE Series UPS kw for best-in-class multi-mode operating efficiency

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

PowerGem Pro Uninterruptible Power Supply

Product catalog. Cyberex data center products Overview catalog

Permissible ambient temperature Operation Storage, transport

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Specification Requirements DBL 700MX and 1000MX Series UPS

LAP ENERGIA PARA DATACENTERS

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Secondary Unit Substations

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Integrated Power Systems for Data Centers

SG Series UPS kva. with ultra-high efficiency eboost technology

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SNMP Web Management. User s Manual For SNMP Web Card/Box

Uninterruptible Power Supply

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

4.0 UPS dedicated to ICT for unmatched energy savings

Smart-UPS 3 Phase And MGE Galaxy 3500

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

High-Efficiency AC Power Distribution for Data Centers

SWITCHGEAR. EGP Switchgear

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Liebert NXC from 10 to 200 kva

Model #: SMART2200CRMXL

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

High Power Programmable DC Power Supplies PVS Series

Metering for today s systems

Cisco Nexus 7000 Series Power Supply Modules

Cisco Redundant Power System 2300

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

415V DISTRIBUTION FOR GREEN DATA CENTERS

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

21 st Century Facilities

32VFD Variable Frequency Drives for Centrifugal Chillers

Mission Critical Data Center Systems

Emerson Smart Firewall

Power protection for data centers

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

User s Manual. Management Software for Inverter

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Tough Decision: On-Line or Line-Interactive UPS?

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

GAMATRONIC ELECTRONIC INDUSTRIES LTD.

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

415V DISTRIBUTION FOR GREEN DATA CENTERS

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

PX100 MBP with Configurable Distribution

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

Bypass transfer switch mechanisms

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Chassis, Power Supply, and Element Management

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

User Manual WatchPower

Engineering innovation

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

The Different Types of UPS Systems

Best Practices, Benefits and Economics of Load Testing IEEE PES Fort Worth, TX Chapter July 16, 2013

3500/22M Transient Data Interface

SECTION VARIABLE FREQUENCY DRIVES

PowerPanel Business Edition USER MANUAL

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

Solution Analysis White Paper CHOOSING THE RIGHT UPS FOR SMALL AND MIDSIZE DATA CENTERS: A COST AND RELIABILITY COMPARISON

Power Quality. Uninterruptible Power Supply

Reliability requires consulting engineers and end users to grasp design, maintenance basics. By Reza Tajali, P.E. Square D Power Systems Engineering

Defining the Needs of Modern Data Center Power Systems, Low Voltage Circuit Breaker Application

1.44 kw Programmable DC Power Supplies XLN Series

Transcription:

Zenith STS-1 & STS-3 Series Static Transfer Switches Seamless Input Source Transfers for Sensitive Critical Loads.

Touching all Areas of the Energy Industry GE s diverse portfolio of products and services is helping customers solve problems every day. We touch all areas of the energy industry including energy management, smart grid modernization, coal, oil, gas, nuclear energy, water, wind, solar and biogas. Providing Reliable Power to your Mission-Critical Business Needs With a comprehensive energy management portfolio, GE is uniquely qualified to provide comprehensive datacenter, commercial and industrial infrastructure solutions from its Industrial Solutions and Critical Power businesses. Due to the inherent high-efficiencies offered with GE electrical distribution equipment and GE UPS systems, measurement of PUE can be maximized by the integrated use of these solutions. Numerous critical power products and services can be utilized to deliver reliable datacenter infrastructure support, solid project management and outstanding site service solutions. Over 15,000 downloadable resources for our customers GEIndustrial.com/CriticalPower provides customers with access to the latest product and solutions news, downloadable resources and interactive digital tools. Access to the entire portfolio of product solutions: - Brochures - Manuals - Software - Drawings - Videos Multi-language support in Chinese and Spanish Industry solution offerings & advanced navigation 2

End-to-End GE Solutions for Datacenter Power Needs GE Utility Service Transformer Standby Generator Standby Generator GE MV Main Switchgear GE Generator Paralleling Switchboard GE LV Main Switchgear GE ATS GE LV Switchboard GE Surge Protection GE UPS System GE UPS System GE Static Transfer Switch GE STS Units - Providing Critical Power Source Redundancy! Datacenter Raised Floor IT Critical Load Servers GE Remote Distribution Unit GE Monitored Distribution Unit GE LV Switchboard IT Critical Load Servers GE Distributed Power Busway GE Monitored Distribution Unit Datacenter Slab Floor 3

Zenith STS-3 Series; Three Phase Static Transfer Switch Seamless Input Source Transfers for Critical Loads Fully Automatic, Transparent Dual-Source Switching GE Critical Power is a key supplier of static transfer switches to a wide range of industries. The STS-3 communication package adds to this preference as it incorporates all of the features that the data center manager wants in one compact package. The GE static transfer switch supplies critical loads with a choice between two available sources of electrical power. By continually monitoring power quality, the STS-3 switch automatically transfers to an alternate source without interruption of power to even your most sensitive critical loads. With a sense and transfer time of less than 4ms and he industry s best communication package, the GE STS-3 represents the highest performance power switching solution available. The STS-3 communication package enhances the overall reliability and availability of power to your facility by: Providing instantaneous access to redundant sources of power Enabling on-line maintenance of upstream equipment Showing real time wave form captures on the LED screen Preventing cross connection of sources during transfer and eliminating the possibility of cross current between sources. Redundant power supplied and operator interface panel True System Redundancy Component Redundancy Redundant operator interface module, power supplies, control power circuits and sensors. Logic Redundancy Redundant voltage detection systems, voltage sensing/sampling systems and independent redundant logic with two different logic algorithms. System Redundancy Redundant static transfer mode power path, bypass power path and optional dual isolation switches. Standard Tri-Redundant System The ultimate in power system reliability The GE Difference Packaging Flexibility Configurable as part of GE s MDU/RDU Series of Power Distribution Systems. Rigorous Product Testing Fully rated switching elements are tested at 6000 operations at 150% load and 50 operations at 600% load. This testing is backed by GE Critical Power Quality Assurance Program. Modular Design Modular design results in higher quality throughout the line and delivery schedule ready to meet the most demanding timelines. 4

STS-3 Technical Data & Features Ratings 150, 250, 400, 600, 800, 1000, 1200, 1600 Amp 208, 415, 480, 600 VAC, 3phase 3 wire Switching neutral option (5) or (6) Non-auto circuit breakers 500% overload for 10 sec MTBF exceeds 2,000,000 hours 22 KAIC (65 and 100 KAIC optional) Redundancy Fail safe dual redundant display Triple redundant logic Triple redundant power supplies Dual redundant gate drivers for SCRs- two gate drivers for each SCR Logic Volt second synchronization (VSS) limits downstream transformer inrush on 480 volt systems during: Initial stat up, restarts and transfers VSS start-up, restart or transfer limits to 1.5 times in-rush up to 180 degrees out of phase Dynamic transfer delay for use with UPS systems that have ecomode operation Communications Package Web enabled through Web Browser SNMP port Modbus RTU through RS 422/485 port USB port for downloading stored data - event recapture Security Layered security through log on access User logon ID and PIn number required for STS operation All log ins are time and date stamped for future reference Event/alarm memory is 2MB Certifications ETL listed to UL 1008 standards Physical Data AMP RATING HEIGHT WIDTH DEPTH WEIGHT (LBS) 150-600 74.75 36.50 32.75 900 800 74.75 48.00 32.75 1,100 1000 86.25 53.25 36.00 2,800 1200 74.75 84.00 43.00 3,600 1600 74.75 89.25 43.00 3,600 5

More STS-3 Features Graphical User Interface Fully functional touch screen, 262k color 10.4 x10.4 LCD touch screen, 640x480 resolution Redundant fail safe analog control panel Monitoring Fail safe dual redundant display) All status, events and alarm logs may be viewed via Web Installation and Maintenance Hot Swap capability for Printed Circuit Boards (PCB) - Optical Bus allows for replacement of PCB while Events will record up to 10 seconds after loss power Real Time capture of wave forms STS is powered and connected to the load Branch circuit monitoring systems graphing available Hot Swap capability for touch screen Graphic depiction of voltage and current harmonic trends Graphical User Interface (GUI) - By engaging the Redundant Analog Control Panel, the GUI may be replaced without interrupting power Front access only required for I/R scans of all terminations SCR module is on draw-out slides for ease of service 6 Browsers (STS may NOT be operated via Internet) - Logic module is on draw-out slides for ease of service and greater access for I/R scans All STS stored data is captured and available at the Switch

STS-3 Available Systems Stand-Alone System Primary Redundant STS-3/MDU System Both STS unit and MDU unit are in matching cabinetry for a complete system solution 7

Zenith STS-1 Series; Single Phase Static Transfer Switch Seamless Input Source Transfers, Rack-Mounted Product Introduction GE provides this high speed transfer system for applications where at least two sources of power are available. Called the Zenith STS-1 Series, it is capable of providing coordinated transfer of critical loads between power sources regardless of phase relationship. SCR (Silicon Controlled Rectifer) technology is utilized to ensure that essential equipment power is maintained by transferring loads to an Alternate source in the event of Preferred source failure. Break-before-make switching eliminates concerns of inter-phase shorting, so source synchronization is never required. The STS-1 makes no distinction between synchronous or asynchronous transfer, so unpredictable conditions related to source faults or varying phase shifts from non-utility sources never inhabit transfer. The STS-1 is not subject to the possibility of inhibited transfer due to the sources being out of phase, nor is it generally subject to problems associated with transients, arcing, or harmonics. Applications Recommended applications for the Series STS-1 include: Cogeneration facilities Communication centers Asynchronous power source transfers Continuous emissions monitoring systems Medical life support and emergency facilities Data processing and computer installations Test, measurement and calibration facilities Critical control processes Product Description The series STS-1 incorporates the proven technology of SCR switching with fast acting solid state electronic sensing. Integrated of the SCR components is checked on every transfer to verify the functionality of the switch. In the event off a total power loss, the STS-I transfer time averages 6 milliseconds. Transfer time is simply defined as the average time the load may experience an absent voltage condition. The STS-1 transfer time falls well within the acceptable zone for transfer time as stated by the Computer Business Equipment Manufacturer s Association (CBEMA). All STS-1 units are ETL listed, which qualifies them for both new installations and retrofit projects. Computer/IT Applications Source 1 Source 2 UPS UPS Series STS-1 Static Transfer Switch To single corded IT Server Loads Front Panel Display Critical Process Applications Primary Source Backup Source UPS Series STS-1 Static Transfer Switch To non-it critical process loads 8

STS-1 Features, Benefits, Application Data Features Automatically transfers from a Preferred to an Alternate A.C source in the event of Preferred source failure, regardless of phase relationships. No synchronization required. Automatically transfers back from the Alternate source when the Preferred source voltage is greater that Power Fail Threshold. Incorporates Transfer Back Delay to avoid nuisance transfers on unstable voltage. Source Default Select: This option enables manual selection to determine which source the switch will normally run on if both sources are present. Solid state switches (SCR s) are connected in bridge configuration, effectively doubling their voltage rating. SCR s switch without arcing, voltage, transients or significant current surges. LEDs are provided to indicate source and transfer logic status. Integral relays reflect same via isolated form c contacts terminated for remote indication. No Load Transfer Inhibit: Self-monitoring feature that prevents unsequenced transfers if the load-sensing interlock is not maintained. Transient and Noise Protection: Surge suppressors installed across AC inputs and RFI filtered redundant logic power supplies Manual Transfer is provided on all models. Application Sizing MODEL # AMPS KVA RACK SIZE PHYSICALS 120VAC, 1phase, 60Hz STS1-112025 25 3.0 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs STS1-112045 45 5.4 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs STS1-112065 65 7.8 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs STS1-112085 85 10.2 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs 240VAC, 1phase, 60HZ STS1-124025 25 6.0 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs STS1-124045 45 10.8 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs STS1-124065 65 15.6 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs STS1-124085 85 20.4 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs 220VAC, 1phase, 50HZ STS1-122025 25 5.5 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs STS1-122045 45 9.9 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs STS1-122065 65 14.3 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs STS1-122085 85 18.7 2U 3.5 hi x 19 w x 32.5 dp, 35 lbs Benefits Automatically senses power degradation or failure of the preferred source and initiates a transfer to an alternate source Transfers load between the preferred and alternate sources regardless of phase relationship Restores voltage fast enough to perform a seamless transfer while preventing load malfunction Performs transfer efficiently without causing arcing, contact, bounce, or abnormal current transients Virtually eliminates contact wear and maintenance Connects electrical loads to virtually an existing AC sine wave source 9

Customer Service Support Toll-Free: +1 800 637 1738 US-Based Customer Service Answered Live 24/7 GE Critical Power... Servicing you infrastructure Investments... ATS, UPS, STS, PDU s, and other Electrical Distribution Equipment GE s Services offerings range far beyond standard product support: from on-site services for risk-reducing installation and startup, to availability services to help you proactively reduce downtime and meet your service-level commitments. From installation to product retirement, warranty upgrades to remote monitoring, proactive care to 24/7 problem resolution, you can rely on GE s field service organization for all your electrical infrastructure support needs. On-Site & Emergency Services 24/7 Emergency Hotline Spare Parts Spare Part Kits Product Replacement / Return Equipment Rentals Parts Replacement Contractual Services Maintenance Service Contracts Remote Monitoring & Diagnostics Technical Services Training Training for Operators Training for Maintenance Staff Product Training Web-Based Training 10

Factory Testing & Customer Witness Testing Factory Testing can include, but is not limited to: STS functional tests UPS functional tests UPS/STS integration testing Testing to standard GE test scripts Testing to custom project test scripts Full testing documentation/results Field Testing & Service Capabilities STS Testing UPS System Testing Load Bank Testing Thermography Testing Project Management Site Commissioning Assistance Repair, Upgrade, Retrofit Site Audits & Assessments 11

imagination at work English DEA-587 Rev. 03/14 *Trademark of General Electric Company. Copyright 2014 General Electric Company. All Rights Reserved. 601 Shiloh Road, Plano, TX 75074 Customer Service Support Toll-Free: +1 800 637 1738 US-Based Customer Service Answered Live 24/7 www.gecriticalpower.com 2014 General Electric Company. GE, the GE Monogram, imagination at work, Zenith and all other trademarks, registered trademarks and service marks, unless otherwise noted, are owned or licensed by the General Electric Company or its subsidiaries. The contents of this document are the property of General Electric Company. No part of this work may be reproduced or transmitted in any form or by any means, except as permitted in written license agreement with General Electric Company. The information contained in this document is subject to change without notice.