2 easy to program. Quick start guide to programming C-Bus2 Learn Units

Similar documents
PAC1 Door Access Controller

Dual DVI USB KVM Switch

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

ST-80 MICROSCOPE With Electronic Eyepiece #6810. User Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Keep it Simple Timing

616, 626, 636 & 646 Keypads

USB/VGA Cat 5 UTP Console Extender

ADDING and/or DELETING PIN NUMBERS (Plus other simple programming commands) in My DK-16 or DK-26 DIGITAL KEYPAD

C-Bus Basic Training Manual Volume 1. 1A. Introduction to C-Bus 1B. C-Bus Concepts 1C. C-Bus Hardware Revision Number: V2

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

OVERVIEW Playbacks: Shortcuts: Memories: Data Entry Wheels: Touchpad: Master and Blackout:

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

AVerMedia AVerKey imicro User s Manual

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

INSTALLER S & OWNER S MANUAL

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

DATASHEET. ADAM Arduino Display Adaptor Module. Arduino Compatible Shield P/N: 4Display-Shield-FT843 For the 4D Systems 4DLCD-FT843 Display

Security System. User Guide for the LED Command Center

VARIO PROX CARD READER INSTALLATION MANUAL

Desktop Programmer (DTP)

WARRANTY AND DISCLAIMER

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Inwall 4 Input / 4 Output Module

HILLS Series LED Code Pad User Manual

COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Operation Manual Videohub Software Control. Mac OS X Windows

User's Guide. Integrating Sound Level Datalogger. Model Introduction

EM6556 e-domotica Mini Switch

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Field Commander Wiring Manual

LH110 Series DVR: Frequently Asked Questions

SMC 3000 Series Master Clock Programming Manual (V3) Table of Contents. Getting Started.. Page 2. Setting the Time of Day...

Installation Instructions

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

PL-1, Pocket Logger B

PRT3 Printer Module: ASCII Protocol Programming Instructions

Alarm Security Kit - NVR

Model Owner s Manual. Español - P. 19 Français - P. 39

NortechCommander Software Operating Manual MAN R6

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Die-Cast Metal, Motion- Activated Post Light

Setup guide. point to point wall plate extenders

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

W8735B Telephone Access Module

MICROPROCESSOR HOME - SECURITY SYSTEM Home4

e-ask electronic Access Security Keyless-entry

SECURITY SYSTEM NOTES

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

EBDSPIR-PRM, EBDSPIR-PRM-IP

Pop-up Surveillance Camera On Your TV

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Secure Keypads for access control

astec Integrated Alarm System USER GUIDE

User Guide. Soft-Touch TM Bluetooth Laser Mouse N2953

78 Battery Converter HDMI to SDI

MOBILE ALERT MONITORING SERVICE TUTORIAL

Universal Wireless Effects Controller USER S GUIDE SA115

APPLICATION NOTE. AT16268: JD Smart Cloud Based Smart Plug Getting. Started Guide ATSAMW25. Introduction. Features

Solution-16 Operators Manual ISSUE 1.60

Comfort Control Relay Panel (CCRP)

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

PART 11: START-UP PROCEDURES FOR THE INSTALLER

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

Software manual Displays and Dash

CONSOLE REMOTE I /O AC 9V

CHAPTER 1. GETTING STARTED... 1

SECURITY SYSTEM NOTES

PUSH BUTTON START INSTALLATION MANUAL

Instruction Guide. Professional VGA to NTSC/PAL TV Converter with Remote VGA2NTSCPRO. The Professionals Source For Hard-to-Find Computer Parts

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

ACD 2000 Agent Guide for the Superset 4015

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

KNX System Principles

REMOTE CONTROL MANUAL

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Flarm LED indicator. Version 1.1

ios 9 Accessibility Switch Control - The Missing User Guide Updated 09/15/15

ExStik TM ph Waterproof Meters

MP3-Digital Audio Player. MP55BK User Manual

TABLE OF CONTENTS 1. PACKAGE CONTENTS / SYSTEM REQUIREMENTS REGISTRATION / TECHNICAL SUPPORT DEVICE LAYOUT... 5

Software Manual RS232 Laser Merge Module. Document # SU Rev A

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User's Guide Integrating Sound Level Datalogger Model

CA-125 Owner's Manual

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

HILLS Series LED Code Pad User Manual

User s Manual. Bluetooth Calculator Keypad. Page

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Conferencing. (Standard Phone)

Signature and ISX CM870 Electronics

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

Operating Manual Color Changing Fountains

Owner s Guide. ca6554

VIBRATION WATCH with: Vibration Alarm (won't disturb others). Beep Alarm (optional) Electro-Luminescent (EL) back light (for viewing display at

Transcription:

2 easy to program Quick start guide to programming C-Bus2 Learn Units

Contents 1. Entering Learn Mode................................................. 4 2. Choosing the Electrical Loads to be controlled............................. 5 3. Selecting the C-Bus2 Key Input Switches Units to control the chosen loads 3A. Setting Input Units as On/Off Switches........................................ 6 3B. Setting Input Units as Dimmer Switches........................................ 7 3C. Setting Input Units as Timer Switches......................................... 9 4. Setting C-Bus2 Movement Sensors to control the chosen Electrical Loads....... 12 2001 Copyright Clipsal Integrated Systems Pty Ltd. All rights reserved. Disclaimer Clipsal Integrated Systems Pty Ltd reserves the right to change specifications or designs described in this document without notice and without obligation.

What is C-Bus2? What is C-Bus2 Learn Mode? C-Bus2 is a micro-processor controlled wiring system that uses unshielded twisted pair data cable (or bus ) as its communication medium to control lighting, airconditioning, fire detection systems, access control systems, security and other applications in any building. The system is highly flexible in the way it operates because each device communicating on the bus cable has its own inbuilt microprocessor. These devices can be programmed to provide optimum control in any installation. Information comes from Input Units such as Keys, Touchscreens, Occupancy Sensors, and messages are sent via the C-Bus to appropriate Output Units such as Relays and Dimmers. Messages are used to control the loads connected to the Output Units. C-Bus2 is the latest generation of Clipsal C-Bus, which allows users to set relationships between Output Units and Input Units without a computer. C-Bus2 can be programmed by simply pressing keys in a sequence, much as you program a video recorder. As long as you know the sequence, which is explained in this booklet, you can decide which switches are going to control which lights, or airconditioners, or pool pumps, for example.

1. Entering Learn Mode Action Hold down a toggle key on any output unit for 10 seconds. Result Unit and C-Bus indicators On Output Units will flash alternately. (Note: These two indicators may initially flash together for up to 20 seconds before flashing alternately.) All loads and indicators will turn off except the one pressed which will turn on. All indicators on Input Units will turn off. 4

2. Choosing the Electrical Loads to be controlled Action Press the toggle key switches on the Output Units which turn on the desired lights. Result Unit and C-Bus indicators continue to flash alternately. The selected lights and indicators are switched on. 5

3. Selecting the Key Input Switches to control the chosen loads 3A. Setting Input Keys as On/Off Switches Action 1. Press the Key Inputs required to control the selected loads. Action 2. Exit Learn Mode by pressing any toggle switch on a Relay Output Unit for 2 seconds. Result 1. The switches required to control the loads will be illuminated. Result 2. C-Bus2 will now Learn the relationship and will return to normal operation. Unit and C-Bus indicators will stop flashing. 6

3B. Setting Input Units as Dimmer Switches Action 1. Press one key for a single key operated dimmer. Result 1. toggle dimmer OR Press two keys on the same unit for two key operated dimmer. The first key pressed will be an on/up key and the second key pressed will be the off/down button. 1. on/up off/down on/up 2. 1. 2. off/down 7

Dimmer Switches continued... Action 2. Exit Learn Mode by pressing any toggle switch on a Dimmer Output Unit for 2 seconds. Result 2. C-Bus2 will now Learn the relationship and will return to normal operation. Unit and C-Bus indicators will stop flashing. 8

3C Setting Input Units as Timer Switches Action 1. Hold down a key until the indicator comes on, then release the key. Action 2. Continuing to hold down the key will cause the indicator to double flash every one second. Result 2. Each double flash represents 5 minutes. For example, releasing the key after 4 double flashes gives a 20 minute timer. Result 1. The key switch will flash at one second intervals. (Note: Exiting Learn Mode at this point will make the key a 5 second timer.) 9

Timer Switches continued... Action 3. Exit Learn Mode by pressing and holding down any toggle switch on a Relay or Dimmer Output Unit for 2 seconds. Result 3. C-Bus2 will now Learn the relationship and will return to normal operation. Unit and C-Bus indicators will stop flashing. 10

4. Setting C-Bus2 Movement Sensors to control the chosen Electrical Loads Action 1. Using a screwdriver, change the light level setting on the bottom of the C-Bus2 Movement Sensor. Action 2. Wait for the indicator to double flash (after 5 seconds) then immediately (within 1 second) turn the adjusting trimpot back the other way. Result 1. Indoor sensor Outdoor sensor The red indicator behind the Sensor window will flash once. Result 2. The red indicator behind the Sensor window will then come on and stay on. The unit is now ready to learn its time out. (Note: If the indicator stays off then go back to Action 1.) 12

Movement Sensors continued... Action 3. Changing the setting again will cause the indicator to begin double flashes. Result 3. Each double flash represents a 5 minute timer duration. Action 4. Turn the adjusting trimpot back the other way. Result 4. The indicator will single flash showing that a timer function has been set. 13

Movement Sensors continued... Action 5. Exit Learn Mode by pressing any toggle switch on a Relay or Dimmer Output Unit for 2 seconds. Result 5. C-Bus2 will now Learn the relationship and will return to normal operation. 14

2 easy to program Disclaimer Making any changes to any C-Bus2 system using the Learn Mode features described in this booklet are carried out at your own risk. Clipsal Integrated Systems Pty Ltd is not liable for indirect, special, incidental or consequential damages arising out of the use or inability to use C-Bus2 Learn Mode features. For service on your C-Bus2 Learn Enabled System contact Company: Telephone: Installed Date: 2001 Copyright Clipsal Integrated Systems Pty Ltd CIS Part No. 1036908