Patch Cable Cat 6. Features & Benefits. Standards. Applications. 100% Tested. ULTIMATE Cat 6 Patch Cables ULTIMATE STRUCTURED CABLING

Similar documents
Communication, Signal & Data Cables

TECHNICAL SPECIFICATION

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

Ethernet Cat 5e & Cat 6 Patch Panels

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

Specification SFTP CAT6 Network Cable 23AWG CU

LS Data Communication Product

Always with Our Customers

RTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

E Series. E Series. Category 6 and 5e. Features

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Standard Buccaneer - Ethernet

6000 Series Buccaneer

QUALITY. Made in the USA

Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

Sound, Alarm & Security Cable 7

Category 6 UTP - Cabling System

Standards Affecting a Premise T-1 Installation

ETHERLINE Ethernet Cable, Connectors & Tools

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Gulf Cable & Electrical Ind. Co.

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

Innovative Connectivity Solution for Maximum Performance and Security

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

TENDER: Tf{/ A

Coaxial Cable Solutions Guide

IFS SP-PoE Splitter User Manual

PRODUCT SPECIFICATION

Data Cables. European Edition

iseries Ethernet cabling and configuration requirements

COAXICON Contacts. RF Coax Connectors. Product Facts

INTERNATIONAL STANDARD

ISO VIEW OF AX SERIES XLR CABLE CONNECTOR

Tri-Rated Flexible PVC Equipment Wire

RF & Microwave cable assemblies C291

CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections

Total Solutions Verification

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

Cabling for 10GBASE-T and Beyond - A Tangled Web

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

APR 2016 Rev M

PERFORMANCE AND VALUE FOR YOUR DAY-TO-DAY TEST APPLICATIONS.

MICROCABLES. A complete vision of your connectivity needs. Catalogue

KVM - DVI, USB 2.0, Cat 5 Extender

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Copper Systems Contents

USB Rover port USB m Cat 5 Extender. User Guide

Network Engineers Everywhere:

HARTING Ethernet Cabling 8-poles Overview

Universal MATE-N-LOK Connectors

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

.093 [2.36] Commercial Pin and Socket Connectors

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Model CS 64 Mini-DIN Cable and Adaptor

Color Mark Sensor with Red or Green LED E3S-VS

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

AMP Standard Terminals and Splices. RoHS. Ready

AC 800M EtherNet/IP DeviceNet Installation

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Crestron CAT5 Wiring Reference Guide

PCb Cable mount twinax. ConneCtorS

WHITE PAPER December, 2001

Displayport Cable & Adapters

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

Serial Data Grade Cables

HARTING Ethernet Cabling 4-poles Overview

PRODUCT. High Performance Individual Cables

KNOW YOUR OPTIONS: 230 KV POWER CABLES

PANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security

FASTON Terminals and Connectors

Panduit 28 AWG Patch Cords Installation Guideline

Category-6 / Class-E Cabling

Times Microwave Systems Hermetically Sealed Assemblies

Appendix A lists known cable and connector vendors, part numbers and contact information for sourcing.

Keystone Network Isolator with ESD- and Lightning Protection

Section kv Power Cables

AMP NETCONNECT Product Catalog. Our commitment. Your advantage.

Errors Related to Cable Resistance Imbalance in Three Wire RTDs

Model CFA-24 Transparent Cable Farm Automation Switch

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

Abstract: This document examines the alien NEXT performance of various bundled cables and measures the impact upon various networks performance.

AMP CO Plus Insert for Cat. 6 A Applications

Intersection Preassembled 19-inch Rack

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

SMARTen 24 UTP Patch Panels

Commercial Coaxial Cable

RJF TV Ethernet connection system for harsh environment

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

UTP Video Cables. Pair 2 - Category 5E Type 100Ω. The first pair is used for video transmission.

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Transcription:

Patch Cable Cat 6 Features & Benefits 100% Made in the USA Every Patch Cable 100% Performance Tested 100% of Materials Meet or Exceed Standards High-Density, Snag Free Boot Full power sum performance Documented balance characteristics (LCL, LCTL) ELT verified to ANSI/TIA/EIA-568-C.2-1 Category 6 Standard Power sum characterization gives highest performance for existing applications Characterized to 500 MHz, 250 MHz greater than the standard Side A Side B Standards North American: ETL Verified to ANSI/TIA/EIA-568-C.2 Category 6, UL 444 and C22.2 No.214-02 International: ISO/IEC 11801 2nd Edition Category 6, EU Directive 2002/95/EC (RoHS) Applications comcables Ultimate Cat 6 Patch Cables are intended for high speed data applications including: IEEE 802.3 1000BASE-T 1 Gb/s TIA/EIA-854 1000BASE-TX 1 Gb/s ATM 155 Mb/s 155 Mb/s IEEE 802.3 100BASE-TX 100 Mb/s CDDI 100 Mb/s IEEE 802.3 10BASE-T 10 Mb/s Cat 6 Patch Cables Length Color Part Number 3ft White N-11111-3M-WHT-CH 3ft Blue N-11111-3M-BL-CH 5ft White N-11111-5M-WHT-CH 5ft Blue N-11111-5M-BL-CH 7ft White N-11111-7M-WHT-CH 7ft Blue N-11111-7M-BL-CH 10ft White N-11111-10M-WHT-CH 10ft Blue N-11111-10M-BL-CH 14ft White N-11111-14M-WHT-CH 14ft Blue N-11111-14M-BL-CH 25ft White N-11111-25M-WHT-CH 25ft Blue N-11111-25M-BL-CH

Patch Cable Cat 6 Connector Component Part Number: CN-C6-SCA A Side Eight conductor modular plug High-speed application Conductors with an O.D. Range of.037/.042 Uses.012 contact Requires conductive load bar Plugs will work for solid or stranded cable Performance Contact material Contact Plating Plug Material Plug Tolerances & Dimensions Operation Temperature Insertion/ Extraction Life Contact Resistance Current/Voltage 100% Made in the U.S.A. Meets or exceeds category 6 TIA/EIA-568-C.2-1 Performance tuned to cables meeting proposed Category 6 specification Phosphor Bronze -.012 thick 50 micro-inch: Selective 24 carat hard gold plate in contact area More than 100 micro-inch minimum nickel plate per current selective gold playing requirements Polycarbonate Complies with F.C.C requirements -40º to +70ºC 1,000 cycles 10 MILLOHMS max. 30 VAC/42 VDC at 1.5 AMPs

Patch Cable Cat 6 Connector Component Part Number: CN-C6-SCB B Side Eight conductor modular plug High-speed application Conductors with an O.D. Range of.037/.042 Uses.012 contact Requires conductive load bar Plugs will work for solid or stranded cable Performance Contact material Contact Plating Plug Material Plug Tolerances & Dimensions Operation Temperature Insertion/ Extraction Life Contact Resistance Current/Voltage 100% Made in the U.S.A. Meets or exceeds category 6 TIA/EIA-568-C.2-1 Performance tuned to cables meeting proposed Category 6 specification Phosphor Bronze -.012 thick 50 micro-inch: Selective 24 carat hard gold plate in contact area More than 100 micro-inch minimum nickel plate per current selective gold playing requirements Polycarbonate Complies with F.C.C requirements -40º to +70ºC 1,000 cycles 10 MILLOHMS max. 30 VAC/42 VDC at 1.5 AMPs

Patch Cable Cat 6 Boot Component Part Number: CN-BOOT-C For use with specific bar style RJ-45 plugs Opening to Accept cables to 6.7mm Clear in Color Material Polycarbonate VO operating Temperature -40º to + 70ºC UL Recognized

Patch Cable Cat 6 Cable Component Part Number: BC-C6EPVC-S-XX-C Cable Characteristics Construction characteristics Type of cable UTP Dimensional characteristics Length per reel 1,000 ft Number of pairs 4 Usage characteristics Field of application Indoor Category Cat. 6 Fire safety CM Technical Data- Physical Conductor 24 AWG Stranded TC Conductor diameter in. (mm) 0.024-0.61 Insulated Conductor Diameter- in. (mm) 0.04-1.02 Cable diameter in. (mm) 0.224-5.69 Nominal cable weight lb./kft. (kg/km) 25-37 Max. installation tension lb. (N) 25-110 Min. bend radius in. (mm) 1-25.4 Installation 0ºC to 50ºC Operation -20ºC to +75ºC Technical Data- Parametric Measurements Mutual Capacitance DC resistance Skew Pair to ground Unbalance Velocity of Propagation Input Impedance DC Resistance Unbalance Technical Data - Electrical Pair chart 5.6 nf/100 m max. 9.09 Ohms/100 m max. 25 ns/100 m max., 300nsec/100 m max. 330 pf/100 m max. 70% nom. 100 ± 15%.0.772-100 MHz ± [13 + 15log (F/100)] 100-350MHz 3% max. Pair-1 White/Blue Blue Pair-2 White/Orange Orange Pair-3 White/Green Green Pair-4 White/Brown Brown FREQ SRL RL IL PS-NEXT NEXT ELFEXT PS-ELFEXT LCL/TCL EL TCTL MHz (db) (db) (db/100m) (db) (db) (db) (db) (db) (db) min min max min min min min min min min 1 26 20 2.4 73.3 75.3 68.8 65.8 50 35 4 26 23.6 4.6 64.3 66.3 56.7 53.7 43 22 10 26 26 7.1 58.3 60.3 48.8 45.8 40 15 16 26 26 9 55.3 57.3 44.7 41.7 37 10.9 20 26 26 10.1 53.8 55.8 42.7 39.7 36 9 31.25 25 25 12.7 50.9 52.9 38.9 35.9 35.1 5.1 62.5 23.5 23.5 18.4 46.4 48.4 32.8 29.8 32 ---- 100 22.5 22.5 23.6 43.3 45.3 28.8 25.8 30 ---- 200 21 21 34.6 38.8 40.8 22.7 19.7 27 ---- 250 20.5 20.5 39.1 37.3 39.3 20.8 17.8 26 ---- 350 19.8 19.8 47.4 35.2 37.2 17.9 14.9 ---- ---- 500 19 19 58.3 32.8 34.8 14.8 11.8 ---- ----