Impurity Structural Identification/Confirmation and Profiling of Carbamazepine

Similar documents
UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Thermo Scientific ExactFinder Software

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

A Complete Solution for Method Linearity in HPLC and UHPLC

Thermo Scientific SIEVE Software for Differential Expression Analysis

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Guidance for Industry

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Mass and Resolution Calibration for New Triple-Stage Quadrupole Mass Spectrometers. Rob Grothe Thermo Fisher Scientific, San Jose, CA

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Thermo Scientific Vanquish UHPLC System. Revolutionize Your. UHPLC Experience

Overview. Purpose. Methods. Results

for mass spectrometry calibration tools Thermo Scientific Pierce Controls and Standards for Mass Spectrometry

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

FT-NIR for Online Analysis in Polyol Production

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

VALIDATION OF HPLC METHOD FOR DETERMINATION OF DOCOSAHEXAENOIC ACID (DHA) IN MULIIVITAMIN CAPSULE DIAH WIDOWATI*, ROS SUMARNY, ESTI MUMPUNI

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Analysis of Various Vitamins in Multivitamin Tablets

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare

[ Care and Use Manual ]

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

Articaine & Epinephrine Injection according to USP method

Appendix 5 Overview of requirements in English

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

WATERS QUANTITATIVE ANALYSIS solutions

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

A NEW METHOD DEVELOPMENT AND VALIDATION FOR ANALYSIS OF RIVAROXABAN IN FORMULATION BY RP HPLC

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Introduction. Methods. Sample Processing

Gas Chromatography Liner Selection Guide

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Chemical analysis service, Turner s Green Technology Group

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

HPLC Basics, Equipment, and Troubleshooting

High Performance Thin Layer Chromatographic Method for Estimation of Cefprozil in Tablet Dosage Form

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Electrospray Ion Trap Mass Spectrometry. Introduction

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

How To Test For Contamination In Large Volume Water

Conversion of a USP Gas Chromatography Method to Convergence Chromatography: Analysis of Atropa Belladonna

Pesticide Analysis by Mass Spectrometry

New drugs of abuse? A case study on Phenazepam & Methoxetamine

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

Targeted and Nontargeted MS Analysis of Contaminants in Storm Water Retention Ponds

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Analytical Test Method Validation Report Template

Transcription:

Impurity Structural Identification/Confirmation and Profiling of Carbamazepine T. Zhang, R. Herbold, K. Comstock, Y. Huang, and G. Jiang Thermo Fisher Scientific, San Jose, California, USA

Overview Purpose: Develop a simple assay for accurate and robust impurity analysis of carbamazepine using the Accela UHPLC system and a high performance Hypersil GOLD CN (cyano) column. And combining the high resolution, high accurate mass spectrometry and Mass Frontier software is a powerful solution for definitive identification and structural confirmation of drug impurities. Methods: HPLC separations were performed on an Accela 1250 LC system and an Accela autosampler (Thermo Fisher Scientific, San Jose, CA, USA). UV absorbance was monitored at 211 nm at 20 Hz using an Accela PDA detector (Thermo Fisher Scientific, San Jose, CA, USA). For LC-MS analysis the LC set up was coupled to an Orbitrap Velos Pro. Results: A simple, accurate and robust quantitative HPLC/UV assay for carbamazepine purity assessment was developed. A high-resolution, accurate mass LC-MS method was used for identification and confirmation of impurities in carbamazepine drug substance. Introduction Carbamazepine is a medication indicated for use in epilepsy, trigeminal neuralgia and bipolar disorder. 1 This widely prescribed tricyclic anticonvulsant is administered orally in usual doses of 400-1200 mg/day and is available in several commercial tablet, capsule and suspension forms. 1 Synthesis-related organic impurities are usually present in bulk forms as well as in pharmaceutical formulations of carbamazepine. Pharmacopoeias set strict standards for the purity of carbamazepine to ensure drug efficacy and safety. The United States Pharmacopeia (USP) establishes 0.2% as the maximum limit for any individual impurity and 0.5% as the total of all impurities relative to the active pharmaceutical ingredient. 2 The USP describes a quantitative HPLC/UV procedure for impurity profiling of carbamazepine that utilizes a 4.6 mm x 250 mm column with L10 packing (5-10 µm silica particles with cyano bonded phases) and a mobile phase consisting of water, methanol, tetrahydrofuran, formic acid and triethylamine. However, the utility of this method for routine quality control analysis is limited by the complexity of the mobile phase, which could lead to poor reproducibility, as well as by the difficulty in achieving the required resolution (Rs 1.7) between carbamazepine and the impurity 10,11- dihydroxycarbamazepine (carbamazepine related compound A), which have comparable polarities and differ widely in their concentrations. Routine drug purity analysis requires simple and robust analytical techniques that deliver exceptional resolution, sensitivity, and accuracy. However, UV-based methods alone neither provide unequivocal identification of known impurities nor enable identification of unexpected contaminants. Liquid chromatography in combination with multi-stage mass spectrometry is the method of choice for the structural elucidation of impurities. Methods Sample Preparation Carbamazepine and related impurities A, B, D and F were purchased from Sigma Aldrich. Stock solutions of 2 mg/ml were prepared in methanol. Solutions of 100 µg/ml concentration were prepared by diluting the stock solution in methanol and were used for method development. Calibration solutions were prepared by serial dilution of the stock solutions in methanol, at concentrations of 250 ng/ml 400 µg/ml for each impurity and 5 µg/ml 1.5 mg/ml for carbamazepine. A mixture containing 1mg/mL of carbamazepine and 500 ng/ml of each impurity was prepared to examine method suitability at a 0.05% reporting threshold. For assessments of system suitability and quantification, a mixture of 1.5 mg/ml of carbamazepine with 3 µg/ml of each impurity was used. Liquid Chromatography Columns: Hypersil GOLD CN column (2.1 x 150 mm, 3.0 µm particle size) Mobile Phase: [A] Water [B] Acetonitrile Column temperature: 30 C Sample injection volume: 1 µl Needle wash: 80:20 (v/v) acetontrile:water 2 Impurity Structural Identification/Confirmation and Profiling of Carbamazepine

Gradient Mass Spectrometry Full MS Scan MS/MS Mass Range m/z 150 to 270 Ion Trap AGC 1e4 Resolution 30,000 FT AGC 5e4 Injection Time 50 ms FT Injection 50 ms AGC Target 7e5 Microscans 1 Results Time A % B % µl/min 0.00 88.0 12.0 400.0 10.00 88.0 12.0 400.0 14.00 75.0 25.0 400.0 18.00 70.0 30.0 400.0 19.00 15.0 85.0 400.0 30.00 15.0 85.0 400.0 31.00 88.0 12.0 400.0 1. HPLC separation of carbamazepine and related impurities The major organic impurities that arise from the synthesis of carbamazepine are 10,11-dihydrocarbamazepine (impurity A, also referred to as USP carbamazepine related compound A), 10,11-dihydro-dibenz[b,f]azepine-5- carbonyl chloride (impurity B), N-carbamoylcarbamazepine (impurity C), iminostilbene (impurity D), 9-methylacridine (impurity E), and iminodibenzyl (impurity F). See figure 1 for structures. An HPLC/UV assay that can accurately and reproducibly detect, identify and quantitate these compounds at trace levels (as low as 0.05%-0.20% relative to the parent drug carbamazepine) is required to comply with USP requirements and ICH guidelines. The USP chromatographic method for determining carbamazepine purity specifies the use of a 4.6 mm x 250 mm L10 column (cyano column with 5-10 µm silica particles), a mobile phase composed of 1000 ml water/methanol/tetrahydrofuran (85:12:3) with 0.22mL formic acid and 0.5mL triethylamine, a flow rate of approximately 1.5 ml/min, and detection at 230 nm. The Hypersil GOLD CN (cyano) column offers alternative selectivity in reversed phase chromatography with lower hydrophobicity compared to C18 alkyl chain phases. The optimal wavelength of 211 nm was determined based on the best signal-to-noise ratio (S/N) for all analytes (Figure 2). Baseline separation of carbamazepine and the impurities at 100 µg/ml concentrations was achieved in 22 minutes using a Hypersil CN column (3 µm, 2.1 x 150 mm) and a simple acetonitrile/water gradient (Figure 3) FIGURE 1. Structures and molecular weights (in Da) of Carbamazepine and Impurities A, D and F. Thermo Scientific Poster Note PN63582_E 06/12S 3

FIGURE 2. UHPLC separation of 12 carbonyl-dnph derivatives at 20 µg/ml concentration FIGURE 3. HPLC separation of a mixture of carbamazepine and its related impurities (100μg/mL) using a 3 µm Hypersil GOLD CN column, 2.1mm x 150 mm. Mobile phase: A- Water; B Acetonitrile. UV detection: 211 nm. A standard solution of 1 mg/ml carbamazepine was analyzed and 600 ng/ml of impurity A (0.06%) was detected at 211nm wavelength (Figure 4. The resolution between the carbamazepine and impurity A peaks was 2.3 which exceeds the minimum resolution specified by USP. Figure 5 shows the chromatogram of the standard 1 mg/ml carbamazepine solution spiked with 0.05% of impurities A, B, D and F at 211 nm wavelength. All impurities were easily detected at these trace amounts, and the stronger UV response exhibited by impurity A was attributed to the 0.06% that was already present in the carbamazepine standard. As the majority of aqueous and matrix contaminants usually elute early at void volume, elution of the first analyte of interest after the sixth minute ensures a robust quantitation method. FIGURE 4. 1.0 mg/ml of carbamazepine standard was analyzed and 0.06% impurity A (600 ng/ml) was detected. FIGURE 5. Impurities are baselineseparated and easily detected at the ICH reporting threshold (0.05%). 4 Impurity Structural Identification/Confirmation and Profiling of Carbamazepine

2. Method Validation System suitability was investigated by analyzing six replicate injections of a solution containing 1500 μg/ml of carbamazepine and 3 μg/ml of each impurity, corresponding to 0.2% of the parent drug. Retention time RSDs ranged from 0.01-0.02%, while peak area RSDs ranged from 1-2% (Table 1), indicating excellent method reproducibility. According to Equation 1, signal-to-noise ratios of 25 are required to comply with the 2% RSD criterion specified by the USP method: % RSD 50/(S/N) (Equation 1) Mean signal-to-noise ratios of the impurities at 0.2% levels relative to the parent drug ranged from 28.5 to 73.4 (Table 1). Quantitative accuracy for all impurities was excellent, ranging from 102 to 111% (Table 1). Table 2 shows that excellent linearity in detector response was observed over the range of 0.25-400 µg/ml (ppm) for all impurities and 5-1500 µg/ml (ppm) for carbamazepine, with correlation coefficients 0.997 for all analytes Table 1. Method validation parameters were assessed by analyzing six replicate injections of each compound. CAA*: corrected area % accuracy Compound Conc. µg/ml n RT RSD% Area RSD% Mean Rs Mean S/N CAA* Impurity_A 3.00 6 0.01 2 NA 73.4 111 Carbamazepine 1500 6 0.01 1 2.2 19720.8 NA Impurity_D 3.00 6 0.01 2 9.1 44.1 108 Impurity_B 3.00 6 0.02 2 11.0 28.5 113 Impurity_F 3.00 6 0.01 1 2.2 34.6 102 Table 2. Excellent linearity of detector response was achieved, with correlation coefficients 0.997 for all compounds. Compound Concentration µg/ml Correlation Coefficients Impurity A 0.25-400 1.0000 Carbamazepine 5.00-1500 0.9973 Impurity D 0.25-400 0.9995 Impurity B 0.25-400 0.9999 Impurity F 0.25-400 0.9998 3. Structural Identification and Confirmation by LC/MS/MS Using an integrated Accela-Orbitrap Velos Pro LC-MS platform, a Hypersil GOLD CN (cyano) column (3 μm, 2.1 100 mm) and a simple, MS-compatible acetonitrile/water gradient, a mixture containing 1.0 mg/ml carbamazepine and 0.15 mg/ml each of impurities A, B, and D was baseline-separated and detected within 16 minutes (Figure 6a). High mass accuracy measurements enabled identification of all analytes. To minimize potential memory effects, a divert valve in the mass spectrometer was configured to re-direct the sample flow away from the ion source during elution of carbamazepine (Figure 6b). The [M+H]+ ion of impurity A was selected for fragmentation by collision induced dissociation (CID) and higher-energy collisional dissociation (HCD) for structure confirmation by LC/MS/MS. See figure 7 (a) & (b). Thermo Scientific Poster Note PN63582_E 06/12S 5

FIGURE 6. (a) Extracted ion chromatogram with MH+ ions of high-resolution, accurate mass LC/MS analysis of carbamazepine and related impurities. (b) Potential memory effects are minimized using a divert valve in the Orbitrap Velos Pro mass spectrometer to reduce unnecessary contamination of the ion source by carbamazepine. a b FIGURE 7. MS/MS spectra of carbamazepine impurity A with MH+ ions. (a) CID MS/MS acquired in the ion trap. (b) HCD MS/MS acquired in the mass spectrometer with chemically intelligent automatic fragment annotation from Mass Frontier 7.0 software. a N O NH 2 239.1179 H b All fragments < 3ppm Conclusion A much more optimized and simplified Carbamazepine and impurities analysis method was developed compared to the reported USP method. With the specific selectivity of Hypersil Gold CN column, a desired method development strategy was successfully achieved. 0.05% impurities relative to main drug were easily detected and fulfilled the USP requirements. 0.2% impurities relative to main drug were accurately quantified and fulfilled all the USP requirements. The relative standard deviation for RT and peak area were all under 2% which is within the limitation of regulatory requirements for a quality control environment. Accurate mass measurements of molecular ion species enabled identification of analytes. CID and HCD MS/MS generated complementary fragmentation information for unambiguous structural characterization. Accurate mass assignment of each of the fragment ions in the HCD MS/MS spectrum and automatic fragmentation annotation using Mass Frontier 7.0 provided definitive structural confirmation. References 1.http://www.merckmanuals.com/professional/lexicomp/carbamazepine.html 2. U.S. Pharmacopeia Monograph for Carbamazepine, USP32-NF27, page 1784. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. 6 Impurity Structural Identification/Confirmation and Profiling of Carbamazepine

www.thermoscientific.com 2012 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific, San Jose, CA USA is ISO Certified. Africa-Other +27 11 570 1840 Australia +61 3 9757 4300 Austria +43 1 333 50 34 0 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China +86 10 8419 3588 Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland/Norway/Sweden +46 8 556 468 00 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9434 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Russia/CIS +43 1 333 50 34 0 South Africa +27 11 570 1840 Spain +34 914 845 965 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752 PN63582_E 06/12S