Table of Contents QO Series Miniature Circuit Breakers Specifications QOvsRCBO Residual Current Circuit Breakers with Integral Overcurrent Protection 2 3 QOE QWIK-GARD Residual Current Circuit Breakers with Integral Overcurrent Protection 4 QOvs Miniature Circuit Breakers LoadCentre Distribution Boards Specifications Rated Current 0A Rated Current 0A 8 9 CLASSIC Metal Consumer Units Certificates Specifications Rated Current 0A 11 11 12 1
QO Series Miniature Circuit Breakers Specifications All circuit breakers fit all LoadCentre Distribution Boards and Consumer Units in the range. Plug-on circuit breakers are tamperproof and provide positive connection to the busbar in one quick operation. Easy for installation and maintenance, with labour cost saved up to 50%. Current ratings from A to 3A, single, double and triple pole. Instantaneous trip type B, C and D. Rated voltage up to 240V AC single phase or 415V AC three phase 50/0Hz. Comply with BS EN 0898. Comply with BS EN 0947-3 : 1992. Additional safety requirements for Disconnectors and Switch Disconnectors as referred to in BS 771. Trip-free handle ensures tripping even when the circuit breaker handle is held or locked in the ON position. To restore service, simply switch the indicative buttom from OFF to ON position once the fault has been cleared, which completely eliminates the cost and inconvenience of replacing fuse links or fuse wire. Full Range of QO Series Miniature Circuit Breaker Breakers 2
QO Series RCBO QOvsRCBO Residual Current Circuit Breakers with Integral Overcurrent Protection QO1vsRCBO Used in Schneider Electric consumer units, LoadCentre Distribution Boards. Compliance with International Standards: IEC 09-2-2 and BSEN 09-1, CE marked. Rated voltage: 240V AC, +%, -15%. Frequency: 50...0 Hz. Class: AC. Ratings: -45 A to 40ºC. Breaking capacity as per IEC 09: ka. Tripping characteristics: Type C (5- In). Tripping time is in compliance with IEE wiring regulations BS771. Sensitivities: or ma (for protection against direct and indirect contact). ON/OFF Indication: - Trip-free handle through an over-center toggle mechanism that ensure tripping even when the handle is held or locked at the ON position. - Overload, short circuit, and earth fault currects are indicated by location of the handle in the OFF position. Push-to-test Function: - A Yellow push-test button T is positioned on the front of the device for testing that product is operational - The smallest operating voltage for the test button: 0V AC (0.85 Un) Connection: - Phase in: plug-on tyep - Phase & Neutral out: 1 to 2 flexible or rigid cable (tightening torque 2 N.m) Catalogue Number Single Pole Sensitivity ma Rated Current A QO1vsRCBO QO0vsRCBO QO1vsRCBO QO1vsRCBO QO140vsRCBO QO145vsRCBO QO1vsRCBO QO0vsRCBO QO1vsRCBO QO1vsRCBO QO140vsRCBO QO145vsRCBO 40 45 40 45 3
QO Series RCBO QOE QWIK-GARD Residual Current Circuit Breakers with Integral Overcurrent Protection QOE1C03 Rated voltage of 2V to 240V AC, 50/0Hz, operating voltage: 50V 250V AC, 50/0Hz. Used in Schneider Electric Consumer Units, LoadCentre Distribution Boards and can be retrofitted to existing installations. Compliance with International Standards : Certfiied to IEC 0898 and IEC 09, ka at 240V AC, 50/0Hz, CE market. ON/OFF Indication: ON/OFF marketings are on the face of the circuit breaker along with the international I/O markings. Handle Operation: Trip-free handle through an over-centre toggle mechanism that ensures tripping even when the handle is held or locked in the ON position. Trip Indication: Indication of a tripped circuit breaker on overload or short circuit is by location of the handle in the OFF position. Indication of a tripped circuit breaker on residual current ground fault is by location of the handle in an intermediate position. Push-to-test Function: A push-to-test button is positioned on the front of the device for testing the residual current electronic trip circuit and mechanism tripping interface. Thermal Trip Element: Thermal trip elements are factory calibrated at ºC ambient temperature. Instantaneous trip level: - Type B: (3-5In) Overcurrent protection for sensitive equipment - Type C: (5-In) Overcurrent protection for all application types Class: AC Residual Current Protection: Residual ground-fault trip currents are factory set at ma, ma or 0mA. Trip Mechanism: - Loss of neutral Protection: Device will trip on loss of neutral and is sensitive to both AC and pulsating DC fault current. Device will trip on voltage between neutral and earth greater than 50V AC. - Protection against reversed polarity (Phase and Neutral) - Protection against nuisance tripping (compliance with IEC 1543 for EMC) Mounting: Plug-on connection. 4
QO Series RCBO QOE QWIK-GARD Residual Current Circuit Breakers with Integral Overcurrent Protection Short Circuit Capacity (Icn) : 000A Catalogue Number Single Pole Rated Current A Residual Tripping Current ma Terminal Capacity Load L&N 2 Pigtail Wire Connection Color & Length Earth Yellow & Green Neutral Blue Maximum Earth Fault Loop Impedance Zs OHMs at 50V AC (RCCB) 5 Seconds 0.4 Seconds Type B Instantaneous Trip (3In to 5In) QOEB01 QOE1B01 QOE1B01 QOE1B01 QOE1B01 0 0 0 0 0 0 0 0 0 0 QOEB03 QOE1B03 QOE1B03 QOE1B03 QOE1B03 QOE1C03 Type C Instantaneous Trip (5In to In) QOEC01 QOE1C01 QOE1C01 QOE1C01 QOE1C01 0 0 0 0 0 0 0 0 0 0 QOEC03 QOE1C03 QOE1C03 QOE1C03 QOE1C03 QOEC QOE1C QOE1C QOE1C QOE1C 0 0 0 0 0 5
QO Series Miniature Circuit Breakers QOvs Miniature Circuit Breaker Black in color. Instantaneous trip level type C. Indication of tripped circuit breaker on overload or short circuit is by location of the handle in the OFF position & trip status window. In compliance with specifications: BS EN 0898, IEC 898 - Miniature Circuit Breaker BS EN 0947-3 : 1992 Additional safety requirements for Disconnectors and Switch Disconnectors as referred to in BS 771. Short Circuit Capacity (Icn) : 000A Catalogue Number Rated Current Teminal Capacity Single Pole Double Pole Triple Pole A 2 QO1VSC QO1VSC QO1VSC QO1VSC QO1VSC QO125VSC QO1VSC QO140VSC QO150VSC QO3VSC QO2VSC QO2VSC QO2VSC QO225VSC QO2VSC QO240VSC QO250VSC QO23VSC Type C Instantaneous Trip (5In to In) QO3VSC QO3VSC QO3VSC QO5VSC QO3VSC QO340VSC QO350VSC QO33VSC 25 40 50 3 1-25 1-25 1-25 1-25 2.5-35 2.5-35 2.5-35 2.5-35 Short Circuit Capacity (Icn) : 000A Catalogue Number Rated Current Teminal Capacity Single Pole Double Pole Triple Pole A 2 QO2VSC QO1VSC QO1VSC QO1VSC QO125VSC QO1VSC QO140VSC QO150VSC QO3VSC QO2VSC QO2VSC QO2VSC QO225VSC QO2VSC QO240VSC QO250VSC QO23VSC Type C Instantaneous Trip (5In to In) QO3VSC QO3VSC QO3VSC QO5VSC QO3VSC QO340VSC QO350VSC QO33VSC 25 40 50 3 1-25 1-25 1-25 1-25 2.5-35 2.5-35 2.5-35 2.5-35 QO3VSC
QO Series Miniature Circuit Breakers QOvs Miniature Circuit Breaker Technical data Main characteristics QOvs ka QOvs ka Insulation voltage (Ui) V AC Operating voltage (Ue) 240/415 V AC Rated impulse withstand voltage (Uimp) 4 kv according to IEC 0898-1 Reference temperature 40 C Operating frequency 50/0 Hz Pollution degree 3 Magnetic tripping Curve C 5 to In b b b b According to IEC/EN 0898-1 Limitation class 3 Rated breaking capacity (Icn) 1P, 240 V AC 2P, 240/415 V AC 000 A 000 A 3P, 240/415 V AC Service breaking capacity (Ics) 0 % Icn 75 % Icn Additional characteristics Degree of protection Device only IP (IEC 0529) Device in modular enclosure IP40 Insulation classe II Endurance (O-C) Electrical 4000 cycles Mechanical,000 cycles Operating temperature -5 C to +0 C Storage temperature -40 C to +85 C Tropicalization (IEC 008-1) Treatment 2 (relative humidity 95 % to 55 C) Weight (g) Circuit-breaker Type QOvs 1P 4 2P 8 3P 312 Circuit-breaker Type Number of poles A B C C' D E QOvs 1P 78.3 18.7 58.8 51.4 81 8.3 2P 78.3 37.4 58.8 51.4 81 8.3 3P 78.3 5.1 58.8 51.4 81 8.3 DB404541 Dimensions () 7
LoadCentre Distribution Boards with Finger Safe Protection Specifications Finger safe design for plug on - main busbar to maximize safety (live part have been totally insulated). Built-in with 4 pole main switch for complete isolation (TPN Type). Quick and easy to install. Accepts 1, 2 & 3 pole Plug-on circuit breakers and RCBOs. Range of incoming devices, including 4 pole. Brass neutral and earth terminal bars for every single pole outgoing way. Plenty of cable space, with knock-outs provided at top and bottom. Used in offices, banks, IT buildings, hotels and coercial premises. Bluish white color epoxy powder paint. Zinc coated corrosion resistant steel enclosure. Rated voltage up to 415V AC three phase. Main switch comply with BS EN 0439-3. Enclosure protection to BS EN 0529 IP41 (on request for higher IP rating). Comply with BSEN 0439 & IEC 0439. Finger Safe Full Range of Miniature Circuit Breaker Boards 8
LoadCentre Distribution Boards Rated Current 0A Catalogue Number No. of Ways Height Dimensions Width Depth SQDLC4-0 SQDLC-0 SQDLC8-0 SQDLC1-0 SQDLC112-0 SQDLC114-0 SQDLC1-0 SQDLC118-0 SQDLC1-0 LoadCentre TPN Type (Installed with 0A TPN Main Switch) 4 8 12 14 18 453 5 57 24 81 738 795 852 909 SQDLC4-0 SQDLC-0 SQDLC8-0 SQDLC2-0 SQDLC212-0 SQDLC214-0 SQDLC2-0 SQDLC218-0 SQDLC2-0 LoadCentre Lug Type (For direct connection w/o Main Switch) 4 8 12 14 18 453 5 57 24 81 738 795 852 909 SAFE For installation of Circuit Breaker or Residual Current Circuit Breaker with Integral Overcurrent Protection Main isolator SQDLC112-0 9
LoadCentre Distribution Boards Rated Current 0A Catalogue Number No. of Ways Height Dimensions Width Depth SQDLC4-0 SQDLC-0 SQDLC8-0 SQDLC1-0 SQDLC112-0 SQDLC114-0 SQDLC1-0 SQDLC118-0 SQDLC1-0 LoadCentre TPN Type (Installed with 0A TPN Main Switch) 4 8 12 14 18 57 24 81 738 795 852 909 9 23 SQDLC4-0 SQDLC-0 SQDLC8-0 SQDLC2-0 SQDLC212-0 SQDLC214-0 SQDLC2-0 SQDLC218-0 SQDLC2-0 LoadCentre Lug Type (For direct connection w/o Main Switch) 4 8 12 14 18 57 24 81 738 795 852 909 9 23 SAFE For installation of Circuit Breaker or Residual Current Circuit Breaker with Integral Overcurrent Protection SQDLC112-0 Main isolator
CLASSIC Metal Consumer Units with Finger Safe Protection Specifications Finger safe design for plug on main busbar to maximize safety. Used in apartments. IT buildings, banks, hotels and coercial premises. White color, epoxy power paint. Zinc coated corrosion resistant steel enclosure. Rated voltage up to 240V AC single phase. Comply with BS EN 0439 & IEC 0439. Plug-on main switch complies with BS EN 0947-3 : 1992. Plug-on circuit breakers provide positive connection to the busbar in one quick operation, saving up to 50% on wiring and connection time. Rated Current 0A Catalogue Number No. of Ways Dimensions Weight Height Width Depth kg 0A Rated With Space for Incoming Device SDCS14 SDCS SDCS1 SDCS114 SDCS118 4 14 18 0 238 315 391 517 98 98 98 98 98 1.9 1.9 2.5 3.1 4 Catalogue Number Description Terminal Capacity Dimensions Weight 2 Height Width Depth kg QOMBX Plug-on Incoming Device 0A double pole main switch 35 80 40 85 0.28 Main Isolator Finger Safe Main Busbar SAFE SDCS14 Circuit Breaker or RCBO 11
Certificates Miniature Circuit Breaker 12
Certificates Consumer unit / LoadCentre 13
Certificates Distribution Board Schneider Electric (HK) Ltd. 13th Floor, East Wing, Warwick House, Taikoo Place, 979 King s Road, Quarry Bay, Hong Kong Tel: (852)255 021 Fax: (852)2811 29 Customer Care Centre: (852)2579 999 www.schneider-electric.com/hk Macau Branch Office: Alameda Dr Carlos D Assumpcao 180, Tong Nam Ah Central Comercio 13G, 13H & 13I, Macau Tel: (853)2871 7488 Fax: (853)2871 7499 As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. SEHK/SQD/008 05/12