Custom Express Exhaust Air Energy Recovery: User Guide

Similar documents
Applying Schedules and Profiles in HAP

IES <Virtual Environment> training. Trainee notes. ASHRAE 90.1 Appendix G - PRM Navigator. Version

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

By Tom Brooke PE, CEM

The sample report format is applicable to many different building types and systems and the examples provided cover a variety of applications.

85 F 80 F 50% 75 F 70 F 73.0/ F 10% Figure 1

Tom Brooke, PE, MBA, CEM

Heating, Ventilation & Air Conditioning Equipment

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Florida Power & Light Company. Business Heating Ventilation & Air Conditioning ( HVAC ) Program Standards. Effective: November 9, 2015

Innovent LASER Packaged Fresh Air Conditioning Units

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

How To Design A Building In New Delhi

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

Commissioning - Construction Documents (Page 1 of 6)

TODAY S PARADIGM FOR AIR TO AIR HEAT RECOVERY

Section 2: Estimating Energy Savings and Incentives

Heating, Ventilation & Air Conditioning Equipment

Heating & Cooling Efficiency

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

National Grid Your Partner in Energy Solutions

3/29/2012 INTRODUCTION HVAC BASICS

HVAC Systems: Overview

How to Build a Data Centre Cooling Budget. Ian Cathcart

EnergyPro Building Energy Analysis. Assisted Living Building

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Analysis of data centre cooling energy efficiency

Comparing Energy Savings of Different VAV Systems

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

NetApp Data Center Design

Preliminary Final Proposal

FLORIDA SOLAR ENERGY CENTER

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Creating Efficient HVAC Systems

L ABORATORIES FOR THE 21ST C ENTURY: ENERGY ANALYSIS. U.S. Department of Energy Energy Efficiency and Renewable Energy

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

REAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

for K-12 School Buildings

ULTRA-EFFICIENT HVAC DESIGN AND CONTROL

HVAC Processes. Lecture 7

Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX

Selecting the Supply Air Conditions for a Dedicated Outdoor Air System Working in Parallel with Distributed Sensible Cooling Terminal Equipment


COMPARATIVE LIFE-CYCLE ANALYSIS OF ENERGY-EFFICIENCY MEASURES AT TVA S CHATTANOOGA OFFICE COMPLEX: PHASE II RESULTS & FINAL DESIGN

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Case Studies: Infrared Heating in Industrial Applications

Role of Economizers in Dedicated Outdoor Air Systems

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Bring the fresh in. Dedicated Outside Air Systems

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Moisture Control. It s The Dew Point. Stupid! Its not the humidity.

Heat Recovery In Retail Refrigeration

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

Award-Winning Innovation in Data Center Cooling Design

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, November 2015

Air Side Economizers and Energy Recovery - Improvements and New Regulations. Richard Lord

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

APPLICATION GUIDE. Moisture Management in Waterborne Climate Systems

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

CONTROL STRATEGIES FOR HVAC SYSTEMS

newsletter Let s take a high-level look at airside economizing: what it is, what it requires, and how it s done. How does economizer cooling work?

What are the Carrier ChillerVu Energy Dashboards?

Mail Merge Creating Mailing Labels 3/23/2011

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

Tips and Tricks for Estimating Energy Savings. Celeste Cizik, P.E. Project Manager E M C Engineers, Inc.

Energy Recovery Ventilation Equipment

Defining Quality. Building Comfort. Precision. Air Conditioning

IES <Virtual Environment> Tutorial. Apache Sim (Version 6.0)

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Catalyst RTU Controller Study Report

Datacenter Efficiency Program

Amplification of Notice ; Deduction for Energy Efficient Commercial Buildings

Glossary of Heating, Ventilation and Air Conditioning Terms

Energy Efficiency in Industrial HVAC Systems

Mechanical Systems Proposal revised

ASHRAE Rocky Mountain Chapter. RickPhillips Phillips, P.E., PE LEED AP Senior Mechanical Engineer The RMH Group, Inc.

Improving Data Center Energy Efficiency Through Environmental Optimization

Data Centers WHAT S ONTHEHORIZON FOR NR HVAC IN TITLE ? SLIDE 1

Whole House Dehumidification for Occupant Comfort and Energy Savings

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

Data Center Energy Profiler Questions Checklist

J O U R N A L. Energy Performance for. Proper Specification of Air Terminal Units Future Climate Impacts on Building Design

ASHRAE Student System Selection Competition New Office Building - Nashville, Tennessee Spring 2009

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Outline. CC objectives Site and building description Typical data floor overview CC measures Results Lessons learned

Pool Dehumidification Basics

HOURLY ANALYSIS PROGRAM QUICK REFERENCE GUIDE

CRITICAL COOLING FOR DATA CENTERS

Optimizing the Efficiency of the NCAR-Wyoming Supercomputing Center Facility. Ademola Olarinde Mentor: Aaron Andersen

Evaporative Cooling System for Aquacultural Production 1

Using Microsoft Project 2000

Transcription:

Custom Express Exhaust Air Energy Recovery: User Guide Introduction In systems with exhaust air energy recovery, some of the energy from the exhaust air stream is used to precondition the incoming fresh air stream. A variety of devices can be used to mediate the energy exchange. Some devices transfer sensible heat only (e.g. heat pipe, sensible plate, sensible wheel, glycol run-around systems), while some transfer both heat and moisture between air streams (e.g. enthalpy plate, enthalpy wheel). Good applications of exhaust air energy recovery include systems with large ventilation air requirements in hot or cold climates. Systems that include moisture recovery are beneficial when outdoor humidity levels are very different from controlled indoor conditions. In addition to producing energy savings, exhaust air energy recovery may allow downsizing of heating and cooling systems due to reduced ventilation loads at design conditions. The Exhaust Air Energy Recovery Custom Express spreadsheet calculates the annual energy savings associated with exhaust air energy recovery systems, and produces a preview of the available incentive. (Incentive amounts are subject to approval by National Grid.) Applicability This spreadsheet is designed to be applied to a wide range of situations, including: New construction ( D2 ) and retrofit ( EI ) applications Heat recovery devices of the following types: sensible wheel, sensible plate, enthalpy wheel, enthalpy plate, heat pipe, glycol run-around Systems with constant supply airflow and variable air volume systems This tool must not be used in the following situations: If the proposed energy recovery system does not exceed the requirements of the applicable building code (assumed to be referenced to ASHRAE 90.1-2007). This condition applies to new construction projects only; no energy savings can be associated with a new system which does not exceed code requirements. For more information on code requirements, please see the section titled Part 4: Measure Cost on page 8 of this guide. If the proposed energy recovery is not exhaust air energy recovery, e.g. the tool cannot be used to calculate savings due to wrap-around precool/reheat ( desaturation ) cooling coils If the proposed system is to be equipped with demand-controlled ventilation in addition to exhaust heat recovery If the performance of the installed heat recovery equipment is expected to be significantly degraded by dirt or other site conditions Compatibility The spreadsheet is compatible with MS Excel 2003 and later versions. Questions? Please contact Dinesh Patel at National Grid (dinesh.patel@nationalgrid.com) with any questions on the applicability or use of this spreadsheet tool. Contact the facility owner s representative, design engineer, equipment vendor, or facility manager for assistance in obtaining the information requested in the spreadsheet. National Grid Page 1 of 8 Exhaust Air Energy Recovery

Usage instructions Open the spreadsheet (ERV Custom Express.xls) in MS Excel. Work through the spreadsheet s tabs in sequence, starting with the Instructions tab. Instructions tab: This tab contains a brief version of the instructions contained in this user guide. Please pay particular attention to the first instruction: you must enable macros to allow the sheet to work. Authorized National Grid representatives wishing to view or edit the detailed calculations should enter Yes in the input box and then enter the password when prompted. Otherwise, please do not modify the No input. Authorized NGrid representative? No Basic Info tab: Enter all requested information on the Basic Info tab. The calculation will not function properly if certain fields are not completed. National Grid ERV Custom Express Tool Date: Application #: NGrid contact: Please make sure to complete the next three fields before proceeding: Facility name: Facility street address: Weather location: (pick closest match) State: (must be completed) Number of non-identical ERVs: 1 (for more than 5 ERVs, continue on a second spreadsheet) New AHUs or retrofit ERVs? (use separate spreadsheets for different types of installation) Customer contact: Customer phone #: Notes: Customer email address: Type of facility: Type: Notes on specific fields: Weather location: choose from the dropdown list. Choose the location whose climate most closely matches the climate at the facility s location. The available locations are: Boston, Worcester, Providence, New York City, Albany, Buffalo, Syracuse, and Watertown, NY. Number of non-identical ERVs: Enter the number of unique systems you wish to include in the application. Identical systems can be entered using a multiplier, so you don t have to enter the same data twice. For example, if your project contains four AHUs with energy recovery, of which three are identical, enter 2 in the box. An input tab will appear for each unique system (named ERV-1 inputs, ERV-2 inputs, etc.). If you have more than 5 unique systems, please continue on a separate copy of the spreadsheet. Note: if input tabs do not appear, please ensure that macros are enabled and that you have entered the number of non-identical systems. New AHUs or retrofit: if energy recovery is to be installed on an existing air handling system, choose Retrofit. If the entire air handling system is new (or being replaced at the end of its life), choose New Construction. If your project contains both retrofit and new construction portions, please use a separate copy of the spreadsheet for each. National Grid Page 2 of 8 Exhaust Air Energy Recovery

ERV Input Tab Layout ERV-1 inputs Please complete all fields colored green. Some fields incomplete Some fields inc Some fields incomplete Click to clear sheet Copy all inputs from ERV- 2 GO 1. AHU design information 2. Energy recovery design information Number of identical systems: Equipment brand and model #: AHU/ERV name(s): Location(s): New AHU or ERV retrofit? 0 Design supply airflow: Supply fan hp: Return/relief fan? cfm hp Age of existing AHU: Type of heat recovery: Variable airflow or constant volume? Design outside airflow: cfm Error: OA > SA Interior conditions: Space temperature: Space relative humidity: Supply air temperature: Summer: Winter: Cooling coil Mechanical cooling? Cooling source: DX efficiency: Chiller plant total efficiency: Heating coil Source: Thermal efficiency: Humidification? If yes, humidification type: Minimum %RH setpoint: Thermal efficiency: 1 2 Summer F Winter Design exhaust airflow: cfm Error: EA>SA F Heating % Sensible effectiveness: % Latent effectiveness: % (Effectiveness values must be at AHRI conditions with balanced airflow.) F Rated OA cfm (if different from design OA cfm): cfm EER Self-contained ERV or integrated in AHU? Do ERV fans turn off when not recovering heat? kw/ton Heat exchanger air pressure drop: Supply: " w.g. % Exhaust: Air bypass when heat recovery is off? Bypass air pressure drop: If glycol run-around, pump hp: Does glycol pump have VFD? 0 % Retrofit % yrs " w.g. " w.g. hp Cooling If rated cfm is different from design OA cfm, pressure drop values provided below must also be at rated cfm. 3. Usage Patterns 4. Measure Cost AHU schedule of operation: Season 2 Month Day Retrofit: Two seasons? Start date End date Materials: Labor: 4 Fan Schedule Season 1 Fan Schedule Season 2 New AHU: System Start Time System Stop Time System Start System Stop Cost of unit: (24hr) (24hr) Time (24hr) Time (24hr) Base unit cost: Weekdays Weekdays Base unit shall include no heat recovery. Weekends/holidays Weekends/holidays 3 Measure cost: (calculated) Typical hourly airflow profile Materials: $0 Labor: $0 Minimum supply airflow ratio: OPTIONAL: To override default profile shown in figure, enter percentage flow values in table below ERV-1 supply airflow profile 5. Notes (optional): Hour # AM PM 12-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11-12 100% 90% 80% Supply airflow (% of design) 70% 60% 50% 40% 30% 20% 10% 0% 0 6 12 18 24 Hour # Season 1 WD Season 1 WEH Season 2 WD Season 2 WEH ERV-1 Savings Calculate ERV-1 Savings Installed on: Sensible recovery (heating): Sensible recovery (heating): Total electric savings (kwh) 0 Latent recovery (heating): Latent recovery (heating): RECALC REQUIRED Total heating savings: Total heating savings: Dec 0.0 Humidification savings: Humidification savings: Some fields incomplete Jan 0.0 Sensible recovery (cooling): Sensible recovery (cooling): Peak demand Jun 0.0 Latent recovery (cooling): Latent recovery (cooling): savings (kw) Jul 0.0 Cooling electric savings: Cooling electric savings: Enter State on Basic Info tab Measure Cost ($) Aug 0.0 Fan/aux electric penalty: Fan/aux electric penalty: % on-peak savings 0% Total electric savings: Total electric savings: Total gas savings (therms) Other fuel savings (MMBtu) Program Measure Life (yrs) 0 0 Total gas savings: Total gas savings: 0 Total other thermal savings: Total other thermal savings: Demand savings: PROPOSED CASE Results preview BASE CASE (if applicable) Demand savings: Materials $0 Dec kw Dec kw Labor $0 Jan kw Jan kw Jun kw Jun kw EI Jul kw Jul kw 15 Aug kw Aug kw on-peak kwh on-peak kwh 0 off-peak kwh off-peak kwh National Grid Page 3 of 8 Exhaust Air Energy Recovery

ERV Input tabs: Complete all of the visible ERV Input tabs (the number of tabs displayed is equal to the number of non-identical systems specified on the Basic Info tab). Except where a cell is marked as optional, enter requested information in all cells colored green. When all the required data has been entered, the words Fields complete will appear at the top of the worksheet. If required information is missing, the savings calculation will not run and the words Some fields incomplete will be visible. ERV-1 inputs Please complete all fields colored green. ERV-1 inputs Please complete all fields colored green. Some fields incomplete Fields complete Please read all explanatory comments attached to the input cells. (Cells with comments are marked with a red triangle in the upper right corner of the cell. To read the comment, hover the mouse pointer over the cell.) Part 1: AHU design information In this section, you will enter design information on the air handling system on which energy recovery is to be installed. Most of the entries should be self-explanatory. Notes on specific fields: Number of identical systems: enter the total number of systems like this one (if there are no other identical systems, enter 1 ). Please remember to enter all the corresponding unit names and locations in the next two fields. Interior conditions: enter the typical summer and winter interior space conditions. If the system includes humidification, the calculation will assume that the minimum humidity setpoint is equal to the typical winter interior relative humidity. Cooling efficiency: chilled water plant or DX efficiency can be left blank if unknown. A default value will then be used by the energy savings calculation. Chilled water plant efficiency should include pumps and cooling towers (if applicable). Thermal efficiency of heating or humidification: enter the annual average thermal efficiency of the heating or humidification equipment. These fields cannot be left blank (if the system does not include humidification, the humidification thermal efficiency can be left blank). Variable airflow or constant volume: If you choose VAV (variable air volume), you will be able to enter the typical daily airflow pattern in Part 3 (see below). For VAV systems, the calculation assumes that supply and return fans are equipped with variable frequency drives (VFDs) for capacity control. (It is safe to use the spreadsheet even for different types of capacity control the associated error will be small.) Note: for the purposes of this spreadsheet, the VAV category includes single-zone systems with variable airflow. National Grid Page 4 of 8 Exhaust Air Energy Recovery

Part 2: Energy Recovery Design and Performance Information Here you will enter information about the proposed heat recovery equipment, including system type, heat recovery effectiveness, design outside and exhaust airflow, and air pressure drop. As noted on the spreadsheet, the heat recovery effectiveness values must be at AHRI rating conditions with balanced (i.e. equal) outside air and exhaust airflows. Please refer to ANSI/AHRI Standard 1060 for details on the rating procedure. Rated performance information (including effectiveness and air pressure drop) is available for many energy recovery ventilation units on the AHRI website: http://www.ahridirectory.org/ahridirectory/pages/erv/defaultsearch.aspx If the proposed equipment appears on the AHRI, please include a copy of the AHRI performance data with the custom express spreadsheet when you send the completed sheet to National Grid. If the proposed equipment does not appear on the AHRI website, please provide a manufacturer s cutsheet showing all requested performance data at AHRI conditions with balanced airflow (outside airflow and exhaust airflow both equal to the design outside airflow for the system). If the airflow at which the energy recovery device is rated is not the same as the design outside airflow of the proposed system, enter the value of the rated airflow in the Rated OA cfm cell. If rated and design airflows are the same, leave the box blank. Rated OA cfm (if different from design OA cfm): cfm Important: if you enter a value in the Rated OA cfm box, all pressure drop information must be entered for the rated airflow. Important note about heat recovery effectiveness: you must enter the effectiveness as defined by AHRI and ASHRAE (i.e. defined in terms of the amount of heat recovered as a fraction of the maximum recoverable heat at rating conditions), not any other performance measure (e.g. efficiency ) of the proposed heat recovery system. System type definitions: Self-contained ERV or integrated in AHU? o o In an integrated system, the main AHU supply and return/relief fans are used to draw air through the heat recovery device. This can be either a new construction or retrofit application. A self-contained ERV contains separate dedicated fans to draw outside air and exhaust air through the heat recovery device (this is typically a retrofit application, in which an ERV module is added to an existing air handler). Air bypass question: please enter Yes if the outside and exhaust air streams do not pass through the heat recovery device when the system is not recovering heat (e.g. when the system is in airside economizer mode). You will then be asked to enter the air pressure drop of the bypass path, which is preferably less than the air pressure drop through the heat recovery device. National Grid Page 5 of 8 Exhaust Air Energy Recovery

Part 3: Usage Patterns Here you will enter the AHU s schedule of operation and, if the unit is VAV type, the typical hourly supply airflow profile. Please note that the AHU schedule of operation could be different from the occupancy schedule of the building. AHU schedule of operation: Two seasons? If there are two distinct seasons of operation, e.g. if the facility is a school which closes in summer, choose Yes. If the AHU s hours of operation do not change throughout the year, enter No. For each season, enter the weekday and weekend/holiday AHU start and stop times (use the 24 hour clock). For example, for an AHU that operates between 8am and 8pm on weekdays, and between 9am and 1pm on weekends and holidays, the table should look as follows: Fan Schedule Season 1 System Start Time (24hr) System Stop Time (24hr) Weekdays 8 20 Weekends/holidays 9 13 To indicate that the system remains off for the entire day, enter 0 for both start and end times. VAV profiles: If you chose VAV operation in Part 1, enter the average minimum supply airflow ratio (minimum supply airflow as a fraction of the design supply airflow): Minimum supply airflow ratio: Please note that the VAV category applies to both classic multi-zone VAV systems and to single-zone systems with variable airflow. The supply airflow profile plot will then show the default airflow profile for the day. If desired (this is optional) you can override the default flow ratio for any hour by entering a value in the table provided. If you are not sure what to enter, just leave the table blank to use the default profile. A custom profile could be useful for e.g. a lab system which operates at design flow (100%) during the day and at 50% flow during nights and weekends. ERV-1 supply airflow profile 100% 90% 80% Supply airflow (% of design) 70% 60% 50% 40% 30% 20% 10% 0% 0 6 12 18 24 Hour # ERV-1 supply airflow profile Season 1 WD Season 1 WEH Season 2 WD Season 2 WEH For a constant volume system, the plot is still a useful check of the start and stop times entered in the usage table. 100% 90% 80% Supply airflow (% of design) 70% 60% 50% 40% 30% 20% 10% 0% 0 6 12 18 24 Hour # Season 1 WD Season 1 WEH Season 2 WD Season 2 WEH National Grid Page 6 of 8 Exhaust Air Energy Recovery

Part 4: Measure Cost Please enter cost information in the cells highlighted in green. Retrofit project: provide labor and materials costs for adding energy recovery to the existing air handling system. New construction project: in this case, the measure cost is the incremental cost associated with adding the proposed energy recovery equipment and controls to the air handling system. You must enter base and proposed case AHU costs. o Proposed unit cost: enter the cost of the proposed AHU, including heat recovery equipment and controls. o Base unit cost: the base case for the measure depends on whether the proposed system is required by ASHRAE 90.1-2007 to include exhaust air heat recovery (future versions of this tool will include ASHRAE 90.1-2010 requirements). In all climate zones covered by this tool, systems with design supply airflow of 5,000 cfm or greater and with minimum outside airflow of 70% or more of the design supply airflow are required to include exhaust heat recovery with total effectiveness of at least 50% at design conditions. Part 5: Notes If the proposed system is not required to include exhaust heat recovery, the base cost must represent the cost of an air handling system without heat recovery but otherwise the same as the proposed system. If the proposed system is required to include exhaust energy recovery, the base cost must represent the cost of an air handling system which includes heat recovery with 50% effectiveness at design conditions. The system must otherwise be the same as the proposed system. The spreadsheet calculation automatically includes baseline heat recovery (assumed to be an enthalpy plate with 50% sensible and latent effectiveness at the design OA flow and balanced flow conditions) if applicable. This section is optional. Please enter any relevant notes you wish to submit to National Grid. Results Preview Once all required fields are complete, the text at the top of the sheet will read Inputs OK. If it does not, please review your inputs to ensure that all required fields have been completed. Once Inputs OK is displayed, click on the button labeled Calculate ERV- # savings. The results table should populate accordingly. The calculation may take a minute, depending on your computer s capabilities. A summary of the savings associated with the heat recovery system will then appear at the bottom of the sheet. For new construction systems which require code baseline heat recovery (see Part 4 above), the savings associated with the base case (relative to no heat recovery) will also be shown. The summary table on the left then shows the difference between base and proposed cases, i.e. the measure savings. National Grid Page 7 of 8 Exhaust Air Energy Recovery

Other ERV Input tabs: Enter information in the same way on all the other ERV tabs. If many of the inputs are the same, all inputs can be copied from another ERV sheet using the button at the top right of the sheet. All entries can also be cleared if desired. Savings Summary Tab: Once all ERV Input tabs are complete, a summary of the savings is available on the Savings Summary tab. If any Calculation Status field indicates that recalculation is required, click on the button below the table: Click to calculate Savings for all ERVs The Savings Summary tab shows the savings associated with each system, multiplied by the number of identical systems of each type. A preview of the available incentive is shown for each group of systems, along with the total savings and costs for all systems. Incentive amounts are subject to approval by National Grid. If any of the Input status fields does not show Inputs OK, or if any warnings appear below the table, please address the issues and then recalculate the savings before forwarding the spreadsheet to National Grid. Measure cost and annual savings summary Installed on: ERV-1 AHU-1 Total # of identical systems: 1 -- Total electric savings (kwh) -5,256-5,256 Dec -1.3-1.3 Jan -1.3-1.3 Peak demand Jun 0.7 0.7 savings (kw) Jul 2.0 2.0 Aug 2.0 2.0 % on-peak savings 31% 31% Total gas savings (therms) 8,168 8,168 Other fuel savings (MMBtu) 0 0 Measure Materials 20,000 20,000 Cost ($) Labor 5,000 5,000 Program EI EI Measure Code ERV ERV Measure Life (yrs) 15 15 Gas Incentive ($) 12,500 12,500 Simple Payback incl. incentive (yrs) 1.3 1.3 Calculation Status: Click to calculate Savings for all ERVs Calc OK All Calc OK Input status: Inputs OK Inputs OK MRDs tab: The minimum requirements document (MRD) for the project will be generated automatically. It can be previewed on the MRDs tab. This page can be printed to collect required signatures, if requested by your National Grid representative. Submitting to National Grid Please save and forward the completed spreadsheet to your National Grid representative, along with the AHRI certification or other required documentation. The spreadsheet file size will probably remain under 10 MB, which should not cause a problem for most email services. If the file is too large to email, or if you are sending multiple files at the same time, please compress it/them and send the zip file instead. Please contact National Grid with any questions or concerns. National Grid Page 8 of 8 Exhaust Air Energy Recovery