Training Props For Rent

Similar documents
Live Fire Training Solutions Firefighter training that could save your life

NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE

Firefighter Review. Instructor Guide

A global leader in: Garner Environmental Services: Garner Decontamination Solutions:

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Decree of the Ministry of the Environment. on fire safety of garages

Section III Hazardous Materials Management

Warehouse Checklist. Warehouse Construction

Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Fire Apparatus Operator Aircraft Rescue and Fire Fighting

Walking and Working Surface Checklist:

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

A. Fire Protection Plan. B. Access and Parking

Certification: Building Plans Examiner. Exam ID: B3

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services

NFPA Fire Fighter II

MPA 65 THE TRIFECTA MPA 65 FINALLY,

BUILDING PERMIT SPECIFICATIONS

How To Build A Basement House

HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME

PRE-DESIGNATED DISPATCHING. Presented by The MCCC ROG Committee

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata Developer Premier Mica Mining And Manufacturing Company

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Name Of Occupancy Date. Yes No Describe

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

Al-Balqa Applied University

Town of Bellingham Fire Department

FIRE PROTECTION BUREAU ACCREDITATION AND CERTIFICATION PO Box Olympia WA (360) FAX: (360) FIREFIGHTER I

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

OREGON FIRE CODE Interpretations and Technical Advisories

RESIDENTIAL COURSE OF CONSTRUCTION QUESTIONNAIRE

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM ENGINE COMPANY SKILLS 1 ¾ RESIDENTIAL ATTACK LINES

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

FLAMMABLE AND COMBUSTIBLE LIQUIDS

The Real Dangers Threatening Workers Who Enter Permit Required Confined Spaces

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Arizona Health Care Association DISASTER PLANNING AND EMERGENCY MANAGEMENT GUIDE POST INCIDENT DAMAGE ASSESSMENT CHECKLIST

Building Code Clarifications - 7. Fire Resistance

Tank Farm and Bulk Storage Fire Incidents

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

CHAPTER 9 FIRE PROTECTION SYSTEMS

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Pollution CO CO 2. Carbonaceo us soot H 2 S, NOX, SO2

1402 Hybrid Firefighter I. Course Orientation Guide (Rev 1)

M E M O R A N D U M. DATE: March 26, 1997 Updated September 7, Alabama Department of Public Health Employees The RSA Tower

Elevating Your House. Introduction CHAPTER 5

MOTOR FUEL DISPENSING SAFETY

Survey: SFM Minimum Standards

Schedule B to By-law

CANTON FIRE DEPARTMENT

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Current as of 11/10/08 1 of 1

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Pre-Drywall Inspection Report

City of Bettendorf Fire Alarm System Requirements

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

Facility Assessment for East Main Street, Huntley, IL

FIREFIGHTER APPLICANT QUALIFICATIONS AND CHECKLIST

Schedule B to By-law Part A Fees Payable for Permits

Waste Oil Collection / Storage

Fire Safety In High Rise Building

October 5, 2015 Dear Client,

SHORELINE SANITATION

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

ACADEMIC CREDIT CLASSES

PUTTING YOU TO THE TEST. The Acclaimed ANSUL Fire School

Flammable Liquids 29 CFR

Errata has been identified as follows:

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

Self-Home Inspection Checklist

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

INTERNATIONAL FIRE CODE SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES

Concord Department of Fire and Life Safety FIRE MARSHAL S OFFICE

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

Prevention through Design: Eliminating Confined Spaces and Minimizing Hazards

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Estimated Cost of Repair

Special events and tents Fire and life safety requirements

Single Family Residential Building Permit Questions & Answers

St. John s University

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

SFFMA FIREFIGHTER CERTIFICATION PROGRAM

Building Information Packet

EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES CONDITIONS OF SITE LICENCE

CAREER OPPORTUNITY Brunswick Fire Department

FIRE PROTECTION SYSTEMS

Transcription:

Training Props For Rent Use of the facility outside of business hours (Monday-Friday 8am 4pm) and/or use of specialized equipment and activities that may present a hazard for the user or the facility may require the presence of a WMFR staff member. This will be billed at $50 per hour with a 4 hour minimum. Commercial Burn Building West Side of Commercial Bldg. Side View from top of tower Burn Buildings There are 3 separate buildings: 1. Commercial Burn Building: This building consists of a seven-story tower with a fourstory burn multi-level building and is approximately 9,500 square feet. It is equipped with LPG fueled props, theatrical smoke, and sound system. Movable walls allow for setting up different room configurations. Provisions ae in place for forcible entry and breaching evolutions. The building features the following props: 3 floor apartment setting (east side) Industrial setting (West side) Commercial Stove fire (1st floor west side, propane, Ceiling fire prop (1st floor west side, propane, Bedroom fire prop (2nd floor east side, propane, Commercial electric panel fire (1st floor, south side, lights, sound, Home office computer electrical fire (4th floor tower, lights, sounds, Fire Alarm scenarios (operational fire alarm panel, lights, strobes, horns) Stairs, Exterior and Interior Multiple room / level search area Ventilation training FDC connections Bailout window Ladder work (Hand, Ladder / Tower Truck, balconies, windows) Wall breach prop (1st floor west side) Forcible entry doors Roof Ventilation prop (4th floor roof, flat & sloped roof) Elevator Prop (3 floors / Doors, fixed platform) Page 1 of 5

Residential Building Fire Behavior Building 2. Residential Burn Building: This building is a multi-functional, multi-level building capable of simulating a residential or below surface fire. The building includes multiple entry points, forcible entry door, a multiple room search area, ventilation training, and bail out window, bedroom & basement fire (above grade prop, propane, and overhead ladder obstructions. It is equipped with LPG fueled props, theatrical smoke and sound systems. Movable walls allow for setting up different room configurations. The Residential Burn Building is over 1,600 square feet. The building also includes an attached garage which houses an LPG fueled car to simulate a garage fire. 3. Fire Behavior burn building (Class A): This building consists of 2 stories, multi-room facility and with multiple entry points. The burn chambers are burnable using wood pallets and straw allowing firefighters the opportunity to encounter live fire. The building has a vent over live fire prop to perform actual vertical ventilation over live fire. Car Fire Prop All of windows in this prop are set up for VEIS evolutions. Car Fire Prop The car fire prop offers a mid-size vehicle with interior seats and dash board accessories, but also includes integrated engine, passenger compartment, rear tire and flammable liquid spill fires. The car fire prop operating system utilizes a wireless handheld control remote that provides the operator with the ability to create flame spread throughout the vehicle and increase intensity while advancing with the students during the training exercise. Additional front bumper shock discharge and flammable fuel spill can enhance the training scenario from the wireless control unit. This prop can be a liquid or vapor fire. Drafting Hose Reel & Pond Drafting / Pumping Prop The Apparatus Drafting Pond provides engineers the opportunity to practice drafting water from an outside source. The 260,000 gallon drafting pond provides water for five on-site hydrants. Page 2 of 5

Vertical Ventilation (Ground based) Vertical Ventilation Training Prop We have a flat roof top and a peak roof; a vent over live fire Ground based roof ventilation: 4:12, 1:12 pitch Elevated (2 nd story) roof ventilation: 4:12, 7:12 pitch Vertical Ventilation (Elevated) Fire Stream Target Fire Stream Targeting Prop / Water Reclamation Tank This prop allows training for high rise and 3+ story buildings. This prop is part of our water reclamation tank, so all water is used on the grounds will be recycled for future trainings. Tower & Climbing Wall Training Tower & Tech Rescue Climbing Wall This is a 7 story training tower, with six-story climbing wall with multiple anchor points. This tower also includes an elevator prop, with 3 floors, doors, and a fixed platform. Included in this tower is also has a multi-story confined space rescue prop. Multiple anchor points, building work located on the tower & commercial (interior & roof) Page 3 of 5

Confined Space tunnel Confined Space Training Prop The underground confined space training prop is designed with four manhole entrances strategically located along 183 square feet of underground tunnel. The underground maze of tunnels range in size from 18 inches to 36 inches and incorporate elevation changes of several feet as the rescuers travel through the confined space tunnels. Trench Rescue Trench Rescue Simulator Prop A concrete trench of varying widths and depths helps personnel build confidence during shoring and cribbing training. The trench is connected to an underground confined space prop that consists four manhole entrances strategically located along 183 square feet of underground tunnel. Maze SCBA Obstacle Course Five shipping containers house the SCBA maze. The maze has 2 levels. One container has fixed props, while two containers have an open room with adjustable walls. There are multiple entry points through doors and windows with an interior fixed ladder and stairwell. This prop allows firefighters to practice search and ladder work. Driving Course Driver Operator Prop Driver instructors teach emergency response driving techniques. Instruction includes both classroom and a hands-on driving course that challenges reaction time, while providing the student with an opportunity to know the limitations of their response vehicles. The drivers track is multi-facet, as various courses can be set up. Our driving course is a NFPA based pre-marked course. The training includes a driver road course, hydraulics, hose work, ladder and platform work, and master stream targeting. Page 4 of 5

Part of the SCT props Structural Collapse Training (US&R) This area has a controlled rubble pile for search and rescue operations. This includes concrete breaking and breaching panels. Along with multi-level collapse structure and a parking garage structure. Additional Burn Props Burn Pans / Extinguisher training Class A & B Dumpster Fire Propane Tank Fire Downed Power Pole with Transformer Page 5 of 5