Ku-Band Redundant LNA Systems

Similar documents
328 Innovation Blvd. 1 Wheaton Road, Witham

sat-nms SMU Signal Management Unit

Chassis, Power Supply, and Element Management

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

Application. Benefits. Contact us. Solution for Indoor TETRA coverage. TETRA/TETRAPOL Repeater RF/OF High Power. To ensure TETRA coverage everywhere

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Research RF Sputtering Packages

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

User Guide Ku Band Solid State Amplifiers SSPA Redundant Configuration

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

LT-82 Stationary IR Transmitter

SATCOM Fiber Optic Products

650W Single Output Power Supply

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

HDO700 P FIBRE OPTIC TRANSMITTER

Uninterruptible Power Supply

F2400 FOM II Series Fiber Optic Modem Technical Manual

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

MCR1900 Media Converter 19-Slot Chassis

Product Specifications

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Unidirectional Transmitter/ Receiver Units Introduction

Applications. Key Features. Benefits. Contact us. Solution for TETRA coverage. AIR Repeater TETRA / TETRAPOL 400 RF/RF

Phase Modular Finally the benefits of Modular ups are for all

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Redundant System Controllers RCP2-1100/RCP FPRC-1100/FPRC-1200 Operations Manual

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

TrueAlarm Fire Alarm Systems

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

Series Six Plus Programmable Controller

Power Supplies 3. SDN-P DIN Rail Series

Rack mounted telephone- and leased line modem for industrial applications

Applications. Key Features. Benefits. Contact us. Solution for TETRA coverage. AIR Repeater TETRA RF/RF High Single

User manual Rev. 1.2 (17/04/2015)

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

I STAR COMPUTER CO., LTD

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

R&S ZCxxx Millimeter-Wave Converters Specifications

DCS Series 1 kw, 1.2 kw, & 3 kw

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Repeaters and Mimics Data Sheet

Application Server V240 Platform

NC-12 Modbus Application

Thyristor-controlled power supplies and battery chargers

TELECOM HF VHF UHF over IP

INPUT SWITCH OPTIONS:

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Model #: SMART2200CRMXL

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

HCS-3600MB2 Conference Main Unit

RC-1SP4T-A18. Key Features. Mini-Circuits P.O. Box 35166, Brooklyn, NY (718)

MASW T. HMIC TM PIN Diode SP2T 13 Watt Switch for TD-SCDMA Applications. Features. Functional Diagram (TOP VIEW)

Compact EGC Amplifier Model 93251

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Maxiva UAX Compact Class

Voltage Regulator SPAU 341 C. Product Guide

Telephone- and leased line modem for industrial applications TD-36

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Cisco 7816-I5 Media Convergence Server

Safety technique. Emergency stop module BO 5988 safemaster

LOXONE 12 Channel Amplifier

Overview of Cisco 2600 Series Routers

MLC TM Maximum Productivity and Versatility for Control without Compromise!

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

R&S SMZ Frequency Multiplier Specifications

Symbol Parameters Units Frequency Min. Typ. Max. 850 MHz

Cisco Redundant Power System 2300

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Waveguide Access Point WGA631. Product Guide

LDG DTS-4/4R Desktop Coaxial Switch / Remote

RS - SPM. Serial parallel translator module

UMEC International Corporation

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

CREATING YOUR OWN RF SWITCHING SYSTEM

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

FlexPoint T1/E1 Copper to Fiber Line Driver

IRT Eurocard. Types DAX-3200

SYSTEM DESCRIPTION Termination Boards

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

HIGH RELIABILITY POWER SUPPLY TESTING

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Model GS Port Node 1 GHz with 40/52 MHz split

Electronic Control Devices The European Product Catalogue 2007

ETL Systems. RSSC Dubna July Global Leaders in Satellite RF Engineering & Custom Build ROUTE AMPLIFY SPLIT SWITCH

SPECIAL SPECIFICATION 6819 Wireless Ethernet Microwave Radio

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

Transcription:

Ku-Band Redundant LNA Systems LRK-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon failure of a primary LNA. A 1:1 system provides one spare LNA for one primary LNA. A 1:2 system provides a spare LNA for either of two primary LNAs. The systems consist of an outdoor plate assembly which mounts at the antenna hub, an indoor control panel and interconnecting control cable. Typical Ku-Band 1:2 LNA Plate Assembly System Block Diagrams Plate Assembly Features 1:1 System LK-12000 Series Ku-band Low Noise Amplifiers (LNAs) High quality dual waveguide/coaxial switches Manual override Waveguide input flanges Output coaxial isolators standard Transmit reject filter(s), input crossguide coupler(s), output coax couplers, and offline I/O options available Redundancy Controller Features 10/100 Base T Ethernet network interface Supports SNMP v1, v2c, and v3 Rack-mount chassis, 19" wide, 1¾" (1 RU) high Dual, redundant power supplies Manual or automatic operation Monitors unit currents, external alarms, or both Automatically switches RF path to standby unit when unit failure occurs User-selectable RS-232/-422/-485 serial I/O M&C interface Parallel I/O M&C interface Menu-driven user configuration of all options Front panel graphically depicts switch positions and unit status Worldwide universal AC input capability standard; consult factory for DC prime power Audible alarm CE certified and RoHS compliant; EAR 99 RF IN TEST IN -40 db IN CONTROLLER 1:2 System POL 1 IN TEST IN -40 db POL 2 IN TEST IN -40 db IN CONTROLLER TRANSMIT INPUT REJECT CROSSGUIDE FILTER COUPLER PLATE ASSEMBLY CONTROL/STATUS TRANSMIT INPUT REJECT CROSSGUIDE FILTER COUPLER TRANSMIT INPUT REJECT CROSSGUIDE FILTER COUPLER PLATE ASSEMBLY CONTROL/STATUS LNA 1 LNA 2 LNA 1 LNA 3 LNA 2 RF COUPLED (-20 db) POL 1 COUPLED (-20 db) POL 2 COUPLED (-20 db)

System Specifications * Parameter Notes Min. Nom./Typ. Max. Units Frequency Range Band E 10.95 12.75 GHz Band R 10.70 12.75 GHz Noise Temperature, System At +23 C See Table 1 Versus temperature See Table 2 Gain Standard LNA 60 63 db LNA with Option 1 50 53 db Gain Match Between LNAs 1 db Gain Flatness Full band ±0.5 db Per 40 MHz ±0.2 db Gain Stability Per day, constant temp ±0.2 db Versus temperature -0.04 db/ C VSWR Input, standard 1.20 1.25 :1 Input, with system option B, Tx filter 1.25 1.30 :1 Output 1.20 1.25 :1 Power Output at 1 db Standard LNA +10 +13 dbm Compression (P 1 db) LNA with Option 2 +18 +20 dbm LNA with Option 2 & system option D, output couplers +17 +19 dbm Third Order Output Standard LNA +20 +23 dbm Intercept Point (OIP 3) LNA with Option 2 +28 +30 dbm LNA with Option 2 & system option D, output couplers +27 +29 dbm AM/PM Conversion At -5 dbm out 0.05 /db Group Delay per 40 MHz Linear 0.02 ns/mhz Parabolic 0.002 ns/mhz 2 Ripple 0.2 ns p-p Maximum Input Power Without damage 0 dbm Desensitization Threshold for Standard system -20 dbm 13.75 14.50 GHz in With system option B, Tx filter +30 dbm Connectors RF Input WR75F Waveguide Flange RF Output Type N Female A Offline In/Out, Coupler In/Out Type N Female A Temperature Range Switch Plate Assy -40 +60 C * System specifications depend on choice of LNA and various options. Specifications shown are for a typical system using LK-12000 series LNAs (Specification 5908). When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. A SMA Female connectors available on request (custom option). 2

Part Number/Ordering Information Ku-Band LNA Systems (a) L R K 0 0 0 0 0 0 0 0 0 0 0 System Type: 1:1..... 1 1:2..... 2 LNA Frequency: 10.95-12.75 GHz E 10.70-12.75 GHz R LNA Noise Temp.: 65 K (b)..... 6 5 70 K...... 7 0 80 K...... 8 0 90 K...... 9 0 LNA Options: 60 db gain (standard).. X 50 db gain (option)... 1 +12 dbm output (standard). X +20 dbm output (option).. 2 System Options: No filter.......... X Tx reject filter, -60 db.... B 13.75-14.50 GHz reject band No input coupler(s)...... X Input CG coupler(s), -40 db... C No output coupler (s)...... X Output coaxial coupler(s), -20 db.. D No offline I/O........... X Offline I/O, terminated, with isolator.. E Control Cable: No cable............. X (Standard service) 100 ft. (30 m)............ 1 150 ft. (45 m)............ 2 200 ft. (60 m)............ 3 250 ft. (75 m)............ 4 Examples: 1:1 system with 10.95-12.75 GHz, 80 K LNAs, no LNA options, no system options, and 100 ft. cable: Order Number L R K 1 E 8 0 - X X X X X X 1 1:1 system with 10.70-12.75 GHz, 65 K LNAs (b), no LNA options, Tx Reject filter, CG coupler, and 200 ft. cable: Order Number L R K 1 R 6 5 - X X B C X X 3 1:2 system with 10.95-12.75 GHz, 90 K LNAs with low gain option, input CG coupler, output coax coupler, offline I/O, and 150 ft. cable: Order Number L R K 2 E 9 0-1 X X C D E 2 1:2 system with 10.70-12.75 GHz, 70 K LNAs with high power output and low gain options, Tx filter, input and output couplers, offline I/O, and 250 ft. cable: Order Number L R K 2 R 7 0-1 2 B C D E 4 Notes: (a) Consult factory for custom configurations. (b) Consult factory for delivery of 65 K LNAs. Table 1 Typical System Noise Temperature with Various Options (Add to T LNA ) System 1:1 1:2 Configuration: Pol. 1 Pol. 2 Standby Standard Configuration (Add to T LNA)... 5 K... 5 K 9 K 14 K With 40 db Crossguide Coupler(s)... 7 K... 7 K 11 K 16 K With Transmit Reject Filter(s)... 18 K... 18 K 22 K 27 K With Tx Filter(s) and Coupler(s)... 20 K... 20 K 24 K 29 K Table 2 Noise Temperature vs. Ambient Temperature Noise temperature vs. ambient temperature can be found from the equation, where: NT 2 /NT 1 = (T 2 /T 1 ) n NT 2 = Noise Temperature at T 2 NT 1 = Noise Temperature at T 1 T 2 T 1 n = Temperature 2 in K = Temperature 1 in K = 1.8 for the LNAs or = 1.0 for passive losses For the case where T 1 = 296 K (+23 C), the ratio NT 2 /NT 1 is shown in the table below for both LNAs (n = 1.8) and for passive losses (n = 1.0): Ambient Temperature T 2 ( C) n = 1.8 NT 2 /NT 1 n = 1.0 NT 2 /NT 1 0 0.86 0.92 +23 1.00 1.00 +40 1.11 1.06 +50 1.17 1.09 +60 1.24 1.13 Example: For a 1:1 system with Tx filter, crossguide coupler and 80 K LNAs, T LNA = 80 K at +23 C and passive losses = 20 K at +23 C; thus, T SYS = 100 K at +23 C. What is T SYS at +50 C? From the table, NT 2 /NT 1 at 50 C = 1.17 for the LNAs and 1.09 for the passive losses: NT 2 = 1.17 x (80 K) + 1.09 x (20 K) = 94 K + 22 K = 116 K at +50 C. 3

Redundant System Controller 1:2 Redundant System Controller, Model RSC12V1-AC The RSC series redundant system controllers for 1:1 and 1:2 systems directly power the LNAs and monitor the output voltages and currents to detect faults. The RSC can also monitor external alarm signals or a combination of output currents and external alarm inputs. Upon detecting a fault, the RSC drives an RF transfer switch to activate the spare unit. The RSC offers monitoring and control of auxiliary RF hardware; remote monitor and control via network, serial interface, or parallel I/O; flexible configuration of system behavior; remote disable of local controls for security; and the ability to detect and report certain failures within the controller itself. A second RSC can be linked to a primary RSC to provide full system control from an alternate control site. When set up this way, the secondary RSC is referred to as a remote control panel, or RCP. The configuration and settings of the primary RSC are transferred to the RCP, which then mimics its controls and interfaces. This permits system operation from a location that is up to 4000 ft (1200 m) distant from the primary controller. Controller Specifications Unit Status Monitor Methods Unit Current Window Width Switchover Time Unit Power Outputs Switch Drive Outputs External Alarm Inputs Serial I/O Interface Controller monitors unit bias current; alarm is generated if current goes outside of allowed tolerance window (LNA or LNB systems). Controller also monitors external alarm inputs (SSPA and other systems) or combinations of both internal unit current and external alarm inputs. ±5% to ±25% of nominal; user selectable in 5% steps (applies to all monitored unit currents) 100 ms maximum +14.3 to +15.0 Vdc, 700 ma maximum -22 to -28 Vdc, 2 A maximum Optionally up to one per unit; require sinking 5 ma at 5 Vdc to negate alarm RS-232/RS-422/RS-485 2- or 4-wire; user selection Parallel I/O Interface Control inputs: Contact closures to ground; require sinking 20 ma at 15 Vdc Status outputs: Form C dry contacts; 100 Vdc, 0.5 A, 3 W max (resistive load) Controller Dimensions Chassis Slides Cable Length to Plate Assy AC Input (standard) DC Input (option) 19 (483 mm) W x 1.72 (43.7 mm) H x 17.5 (445 mm) D; 7.6 lb (3.4 kg) Standard. Radio relay rack-mount brackets available on request. Order cable separately. 100 ft (30 m) to 250 ft (75 m) lengths in 50 ft (15 m) increments are standard; other lengths (up to 500 ft or 150 m) are available by special order. 90-264 Vac, 47 63 Hz, 100 W; Dual AC inputs and dual redundant power supplies. Requires DC-AC inverter. Consult factory. Temperature Range Operating: 0 to +50 C (indoor equipment environment) Storage: -40 to +70 C Relative Humidity Operating: 5% to 95% non-condensing Altitude Reliability Up to 10,000 ft (3000 m) above mean sea level MTBF: 48,200 hours; MTTR: less than 30 minutes with spares and proper technical person. 4

Controller Front Panel Controls and Indicators Unit Status Alarms PS Indicator Panel Test RF Switch Pushbuttons and Indicators Auto/Manual Switch and Indicators Remote/Local Switch and Indicators LED Indicators glow green when OK, red when a fault is detected. Glows red to show fault with either dual redundant power supply. Pushbutton lights all indicators & tests audible alarm. Pushbuttons are used to manually switch units. Front panel indicators show which units are on-line. Unit indicators light red to show faulted units. In a typical 1:1 system, Unit 1 is the primary unit and Unit 2 is on standby. In a 1:2 system, Unit 1 is the primary unit for Pol 1 and Unit 2 is the primary unit for Pol 2. Unit 3 is on standby and can be selected for either Pol. In a dual 1:1 system, Unit 1 is the primary unit and Unit 2 is on standby for Pol 1; Unit 3 is the primary and Unit 4 is on standby for Pol 2. In Auto mode, a unit failure initiates automatic switchover to the standby unit. In manual mode, the on-line unit can be selected from the front panel or by serial I/O, parallel I/O or network command. Selects local (front panel) control, or remote control from serial I/O, parallel I/O, or network. An optional second RSC, configured as a Remote Control Panel, provides the means to operate the system from a physically distant, alternate location. Controller Rear Panel Interfaces 100-135/180-240 V; 47-63 Hz; 1.5A Fusing 100-135V: 250V 2A SLO-BLO 180-240V: 250V 1A SLO-BLO Consult O&M manual for installation instructions. Refer servicing to qualified personnel. J6 SERIAL LOOP J9 NETWORK J1 J2 J3 PLATE ASSY J7 SERIAL I/O J5 REMOTE LINK J4 EXT ALARM J8 PARALLEL I/O J1, J2 LINE 1, LINE 2 (IEC 320-C14) J3 PLATE ASSY (37-pos D, Female) J6 SERIAL I/O and J7 SERIAL LOOP (9-pos D Female) J5 REMOTE LINK (9-pos D Male) J9 NETWORK (RJ-45) J4 EXT ALARM (9-pos D Female) J8 PARALLEL I/O (37-pos D Male) Dual power entry modules contain the AC line input connectors. System can be powered from separate AC lines if desired. Either or both power supplies are capable of operating the system. Cable to plate assembly carries unit power (for line drivers, LNAs or LNBs) and switch drive signals. Order cable separately. Standard lengths are 100 (30 m) to 250 (75 m) in 50 (15 m) increments; other lengths are special order. An adapter cable mates the controller to legacy system cables. RS-232/RS-422/RS-485 connector for user M&C System. Commands provide monitoring, controlling, and configuration. Interconnect cable lengths to 4000 ft (1200 m) with RS-422 or RS-485. A serial loop connector provides a convenient connection for daisy-chained systems. For connection via a proprietary RS-422 link (up to 4000 ft/1200 m) to an optional, second RSC, which duplicates Local control functions at a secondary site. 10/100 Base T Ethernet connection port via standard RJ-45 connector. Supports SNMP v1, v2c and v3. External Alarm inputs. Substitute for or combine with internal unit current monitor alarms. Allows an external signal to indicate unit failure. Unused inputs can be used as status inputs to M&C system. Parallel I/O (discrete logic) connection for limited control and monitoring of the system. Form C relay contact outputs (1:2 system example; others are similar): Unit 1 status PS 1 status Pol 1: Unit 1 or Unit 3 Unit 2 status PS 2 status Pol 2: Unit 2 or Unit 3 Unit 3 status Local/Remote mode Auto/Manual mode Control inputs contact closure to ground (1:2 system example; others are similar): Pol 1 Unit 1 select Pol 2 Unit 2 select Auto/Manual select Pol 1 Unit 3 select Pol 2 Unit 3 select 5

1:1 Plate Assembly Outline Drawing, with Various Options Installed 0.75 [19.0] OPTIONAL RF INPUT 0.25 [6.3] WAVEGUIDE MOUNTING SURFACE 6.40 [162.6] LNA 2 3.40 [86.4] 9.00 [228.6] 7.25 [184.2] S1 LNA 1 W3 OPTIONAL INPUT CROSSGUIDE COUPLER OPTIONAL TRANSMIT REJECT FILTER 0.28 x 0.75 SLOT [7.1 x 19.0] (4 PLACES) 0.63 [15.9] 7.25 [184.1] 8.50 [215.9] 11.50 [292.1] NOTES: 1. PUT ISOLATOR INCLUDED WITH STANDARD SYSTEM. 2. OPTIONAL TRANSMIT REJECT FILTER, CROSSGUIDE COUPLER, PUT COAXIAL COUPLER AND INPUT/PUT SHOWN. 3. DIMENSIONS ARE IN INCHES [mm]. 7.4 [188] 3.50 [88.9] 0.12 [3.2] TO CONTROL PANEL OPTIONAL PUT OPTIONAL COUPLED PUT PUT - Outline 12670-2 6

1:2 Plate Assembly Outline Drawing, with Various Options Installed 8.50 [216] 0.75 [19] LNA 2 OPTIONAL INPUT LNA 3 0.25 [6.3] WAVEGUIDE MOUNTING SURFACE 6.40 [163] OPTIONAL POL 1 COUPLED OPTIONAL POL 2 COUPLED 20.00 [508] 9.00 [229] 7.25 [184] S2 S1 OPTIONAL INPUT CROSSGUIDE COUPLERS 3.40 [86.4] 4.50 [114] POL 1 INPUT POL 2 INPUT 0.28 x 0.75 SLOT [7.1 x 19.0] (4 PLACES) LNA 1 0.62 [16] 7.25 [184] 11.25 [286] 14.6 [372] NOTES: 1. PUT ISOLATORS INCLUDED WITH STANDARD SYSTEM. 2. OPTIONAL INPUT CROSSGUIDE COUPLERS, TRANSMIT REJECT FILTERS, INPUT/PUT AND PUT COAX COUPLERS SHOWN. 3. DIMENSIONS ARE IN INCHES AND [mm]. 3.00 [76.2] 8.1 [205] OPTIONAL TRANSMIT REJECT FILTERS 3.50 [88.9] 0.12 [3.2] 0.60 [15] TO CONTROL PANEL POL 2 PUT - POL 1 PUT - PUT - (ISOLATOR OPTIONAL) Outline 12671-3 7

Other Products Solid-State Power Amplifiers and SSPA Systems Solid-State Power BUCs and SSPB Systems Low Noise Amplifiers and LNA Systems Low Noise Block Converters and LNB Systems Block Up and Block Down Converters Synthesized Converters Line Drive Amplifiers Power Supply Monitors Redundant Control Panels for SSPAs, SSPBs, and LNAs 60 Decibel Road, Suite 200 State College, PA 16801 USA Tel. +1-814-238-2700 FAX +1-814-238-6589 11841 Rev. F Email: satcom@gd-ms.com www.gdsatcom.com/electronics.php 2015 General Dynamics. All rights reserved. General Dynamics reserves the right to make changes to its products and specifications at any time and without notice. All trademarks indicated as such herein are trademarks of General Dynamics. All other product and service names are the property of their respective owners.