DRY TYPE PRESSURE GAUGES, VACUUM GAUGES, COMPOUND GAUGES.

Similar documents
Many Products...One Source

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

79 GAUGE / THERMOMETER H N O

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

4 Posiflow Proportional Solenoid Valves

Thermostatic valve Type AVTA

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

BaseCal 3. BaseCal, the web-based performance calculation tool for Diaphragm Seals

Solenoid valves 2/2-way direct-operated Type EV210A

O to 15,000 psi and media temperature between -130 F and 752 F. Examples of Typical Diaphragm Seal Applications

Compact pressure switch Flameproof enclosure Ex d Model PCA

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

Assisted lift operated 2/2-way solenoid valves Type EV250B

B-Series Switches Pressure, Differential Pressure & Hydraulic

Hose Clamps & Fittings

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Morrison Bros. Co. General Product Specifications

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

B-Series Temperature Switches

Self-operated Temperature Regulators Temperature Regulator Type 1u

Pressure transmitter For general industrial applications Model A-10

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS

Electronic Flow Switches

Toroidal Conductivity Sensor

Thermometer in stainless steel with capillary and switch contacts

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DIAPHRAGM & DIFFERENTIAL PRESSURE GAUGES. Keeping pressure under control AN ISO 9000 COMPANY

Boilers Compressors Chillers Pipe Systems. HVAC & Refrigeration Applications Pressure and Temperature Measurement

AIR LINE VALVES AND GAUGES

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Plastic tube flowmeters Series PT/PS

The Unique Accelabar Flow Meter

Screw Plug Immersion Heaters

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

REGULATORS 175/153 Series

VOYAGER 570G. 744A Sprayer Control

ORLANDO srl. M P R OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Stainless Steel Single and Dual Circulation Kits

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Flow switches Series AD/VH

3/2-way Solenoid Valve, direct-acting, NC or NO

Turbine Flow Sensor Series VTR

Variable V Area Flowmeter Rotameter The Original

VSO MAX HP High Flow Proportional Valve

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Bimetal thermometer Model 52, industrial series

Commercial Gas Cooking Thermostats

HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I.

Models SFP33 & SFP32 Pressure Transmitters

Powers Controls TH 192 S Single Temperature Room Thermostat

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Pressure calibration equipment

OPTIMASS 6000 Technical Datasheet

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

KNC Model 3666 Automatic Pressure Calibration System

How To Use A Flowmeter

Steam System Best Practices Condensate System Piping

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F

Chokes. Types Reasons Basics of Operations Application

VEGAPULS PULSE RADAR FOR LEVEL MEASUREMENT VEGAPULS 60 SERIES

Stainless steel grade chart

Single sub-base valve

Operating Instructions for Plastic Flow Meter. Model: KSK

Fisher 657 and 667 Diaphragm Actuators

Check Valves & Actuated Valves

Blowdown vessels Meeting the requirements of HSE PM60

Oil Sight Glass BENEFITS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

OPTIMASS 1400 Technical Datasheet

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Selecting TEMA Type Heat Exchangers

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

WIKA INSTRUMENT CORPORATION

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

Bypass level indicator With magnetic display Model BNA

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Application Guide. Compensators Hose Assemblies Expansion Joints FLEX-WELD INCORPORATED FLEX-WELD.COM. Manufactured By:

Accu-Switch Instruction Booklet The Direct Drive Difference in Switch Gauges

Digital inductive conductivity transmitter

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

V47 Series Temperature Actuated Modulating Water Valves

2 H OW TO ORDER 2 D ESIGN FEATURES 3 P RODUCTS INDEX 35 O VAL FLANGES 35 B LEED 35 C ONDENSING POTS 36 S YPHONS 36 A IR FEED HEADERS

Relative and absolute pressure switch type 529

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

08.08 Vic-Check Valves

OEM-EP Pressure Controllers

In-Line Electronic Flow Switches

Transcription:

DRY TYPE PRESSURE GAUGES, VACUUM GAUGES, COMPOUND GAUGES. SUITABLE FOR MEASUREMENT OF AIR PRESSURE, WATER PRESSURE, VACUUM PRESSURE, TOWN GAS, ETC. DIAMETER = 1",1.5",2",2.5",3",4",5",6"(25,40,50,60,75,100,125,150,) CONNECTION = 1/8",1/4",3/8",1/2" NPT OR PT PRESSURE GAUGE = -76cm Hg ~ 0 ~ 500kg/cm 2 ( in Hg / psi) MATERIAL = CASE: STEEL, STAINLESS STEEL, PLASTIC. ACCURACY = 1.5%F.S. -1- - 1 -

LIQUID FILLED PRESSURE GAUGES, VACUUM GAUGES, COMPOUND GAUGES. LIQUID FILLED GAUGES ARE FILLED WITH A LIQUID, USUALLY GLYCERIN OR SILICONE OIL AND ARE DESIGNED TO PERFORM AND ENGINEERED TO FUNCTION IN DIFFICULT CONDITIONS AND ENVIRONMENTS. THEY'RE ALSO MORE ECONOMICAL FROM A LONG-TERM PERSPECTIVE: PREVENT HIGH HEAT, PULSATION OR VIBRATION FROM LEADING TO INSTRUMENTS BREAKDOWN. SUITABLE FOR THE HEAVY DUTY SERVICE WHERE PRESSURE IMPULSE, SHOCK AND VIBRATION ARE ENCOUNTERED. DIAMETER = 1.5",2",2.5",3",4",6", (40, 50,60,75,100,150 mm) CONNECTION = 1/8",1/4",3/8",1/2" NPT OR PT PRESSURE RANGE = -76 cm Hg ~ 0 ~ 1000 kg/cm 2 (in Hg / psi) MATERIAL = CASE, BEZEL : SUS304, WETTED PARTS : BRASS ACCURACY = 1.5 % F.S. - 2 -

LIQUID FILLED PRESSURE GAUGES TYPES & DIMENSIONS TYPE A: BOTTOM CONNECTION TYPE B: BACK CONNECTION TYPE C: BACK CONNECTION WITH FRONT FLANGE DIMENSIONS(MM) DIAL TYPE D1 D2 H1 H2 FD1 FD2 40 A/B 47.5 / 47.5 41.1 / 41.1 26.4 / 25 20.7 / 19.4 50 A/B 57.5 / 57.5 50.9 / 50.9 27.5 / 27.5 23 / 23 C 57.5 50.8 27 20.6 69.8 64.5 63 A/B 69.3 / 69.3 61.8 / 61.8 29.5 / 29.5 23 / 22.8 C 69.3 61.8 29.5 22.8 88 79 75 A/B 82.5 / 82.5 73.2 / 73.2 35.7 / 35.7 29 / 29 C 82.5 73.2 37 24 104.9 94 100 A/B 105.8/105.8 98.2 / 98.2 37.2 / 37 30 / 30 C 105.8 98.2 37.2 28.5 131.5 117-3 -

STAINLESS STEEL PRESSURE GAUGES, VACUUM GAUGES, COMPOUND GAUGES. HIGH QUALITY STAINLESS STEEL MADE, FEATURING CORROSION AND HIGH TEMPERATURE PROOF AND WITH HIGH LOAD-SUSTAIN CHARACTERISTICS. SUITABLE FOR MEASUREMENT OF PETROCHEMICAL INDUSTRIES. IT ALSO CAN BE USED FOR MEASURING THE PRESSURE FOR ANY PIECE OF EQUIPMENT THAT IS CHARGED WITH AMMONIA DUE TO ITS HIGHLY INTENSIFIED CONSTRUCTION. DIAMETER = 2.5",3",4",5",6" (60,75,100,125,150 mm) CONNECTION = 1/4", 3/8", 1/2", NPT OR PT. MATERIAL = CASE, BEZEL : SUS304 WETTED PARTS : SUS304, SUS316 ACCURACY = 1.5%F.S. - 4 -

PRESSURE GAUGES, VACUUM GAUGES, COMPOUND GAUGE WITH ELECTRICAL CONTACT SUITABLE FOR AREAS WITH PRESSURE VARIATION. CAN BE USED AS AN ELECTRICAL CIRCUIT SWITCH TO AVOID EQUIPMENT BREAKDOWN FROM HIGH SWITCH FREQUENCY. DIAMETER= 4" (100 mm) CONNECTION = 3/8", 1/2" PT. PRESSURE RANGE = -76cm Hg ~0~ 1000kg/cm 2 (in Hg / psi) MATERIAL = CASE & BEZEL: SUS304 WETTED PARTS : SUS316 OR BRASS ACCURACY = +/- 1.5%F.S. MICRO PRESSURE GAUGES, VACUUM GAUGES LOW PRESSURE GAUGES ARE THE IDEAL CHOICE WHEN MEASURING VERY LOW PRESSURE AND VACUUM GASEOUS MEDIA. SUITABLE FOR TOWN GAS INDUSTRY, MEDICAL APPARATUSES & EQUIPMENT ETC. FOR MEASURING 100MM WATER INJECTION TO 10 PSI POSITIVE & NEGATIVE PRESSURE. DIAMETER = 2.5", 3", 4"; 3 IS OF ECCENTRIC THREAD WITH FLANGE. PRESSURE RANGE: -500/0 mmaq (mm H 2 O) ~ 0/5000 mmaq (mm H 2 O) OPERATING TEMPERATURE: WORKING TEMPERATURE 60 ; AMBIENT TEMPERATURE -20 ~ 60 ACCURACY = 1.5 %F.S. - 5 -

CAPILLARY DIAPHRAGM PRESSURE GAUGE PRESSURE GAUGES USED WITH DIAPHRAGM SEALS ARE WHEN THE PRESSURE MEASURING INSTRUMENT'S SENSING ELEMENT SHOULD NOT COME IN CONTACT WITH THE PROCESS MEDIUM. WHILE CONNECTING A CAPILLARY TUBE IS BECAUSE THE PRESSURE GAUGES CAN BE LOCATED FOR BETTER OPERATOR VISIBILITY. DIAPHRAGMS ARE AVAILABLE WITH 9 TYPES IH TYPE BASED ON USER'S REQUEST AS DESCRIBED IN THE DIAPHRAGM PART. PRESSURE RANGE = -76CMHG ~0~ 1000KG/CM 2 (INHG / PSI) MATERIAL = GAUGE CASE, BEZEL : SUS304; WETTED PARTS: SUS316 OR BRASS CAPILLARY DIAPHRAGM PRESSURE GAUGE W/ELECTRICAL CONTACTS PRESSURE GAUGES USED WITH DIAPHRAGM SEALS ARE WHEN THE PRESSURE MEASURING INSTRUMENT'S SENSING ELEMENT SHOULD NOT COME IN CONTACT WITH THE PROCESS MEDIUM. WHILE CONNECTING A CAPILLARY TUBE IS BECAUSE THE PRESSURE GAUGES CAN BE LOCATED FOR BETTER OPERATOR VISIBILITY. WITH CONTACTS, IT CAN BE USED AS AN ELECTRICAL CIRCUIT SWITCH TO AVOID EQUIPMENT BREAK- DOWN FROM HIGH SWITCH FREQUENCY. THESE GAUGES CAN BE CONFIGURED FOR A 1NO+1NC OUTPUT OR A 1NO OR 1NC. DIAPHRAGMS ARE AVAILABLE WITH 9 TYPES BASED ON USER'S REQUEST AS DESCRIBED IN THE DIAPHRAGM PART. PRESSURE RANGE = -76CMHG ~0~ 1000KG/CM 2 IH-C TYPE (INHG / PSI) MATERIAL = GAUGE CASE, BEZEL : SUS304; WETTED PARTS: SUS316 OR BRASS - 6 -

DIAPHRAGM PRESSURE GAUGE DIAPHRAGM ELEMENTS ARE DESIGNED TO PREVENT SOME SERVICE MEDIA FROM ENTERING INTO THE PRESSURE GAUGE OR TO BE EASY FOR CLEARING THE PLACE WHERE THE PRECIPITATION IS RESIDED. IT IS SUITABLE FOR MEASURING THE PRESSURE OF THE SERVICE MEDIA WHICH IS HIGH CORROSIVE AND EASILY CRYSTALLIZED, OR WITH FLOATING SOLID. PROCESS CONNECTIONS CAN BE FLANGED OR SCREWED. IT FEATURES A STAINLESS STEEL HOUSING AND DIAPHRAGM AND CAN BE SPECIFIED TO FIT YOUR NEEDS. ELECTRICAL CONTACTS, LIQUID FILLING OR THERMOWELL ARE OPTIONS SINGLE FLANGE-EXTRA LONG DIRECT OUTER THREAD- EXTRA LONG DIRECT OUTER THREAD DUAL FLANGE SINGLE FLANGE - 7 -

DIAPHRAGM PRESSURE GAUGE DIAPHRAGM ELEMENTS ARE DESIGNED TO PREVENT SOME SERVICE MEDIA FROM ENTERING INTO THE PRESSURE GAUGE OR TO BE EASY FOR CLEARING THE PLACE WHERE THE PRECIPITATION IS RESIDED. IT IS SUITABLE FOR MEASURING THE PRESSURE OF THE SERVICE MEDIA WHICH IS HIGH CORROSIVE AND EASILY CRYSTALLIZED, OR WITH FLOATING SOLID. PROCESS CONNECTIONS CAN BE FLANGED OR SCREWED. IT FEATURES A STAINLESS STEEL HOUSING AND DIAPHRAGM AND CAN BE SPECIFIED TO FIT YOUR NEEDS. ELECTRICAL CONTACTS, LIQUID FILLING OR THERMOWELL ARE OPTIONS NO. 5 HYGIENE GRADE FOR FOOD FACILITIES IN THE FOOD, BEVERAGES AND MEDICINE INDUSTRIES REQUIRE HIGH-PRECISION TEMPERATURE MEASUREMENT AND MONITORING IN HYBRID PRODUCTION PROCESSES. THE HYGIENE TYPE DIAPHRAGM PRESSURE GAUGE IS MOSTLY SUITABLE FOR SUCH AN APPLICATION. IT FEATURES A STAINLESS STEEL HOUSING AND DIAPHRAGM AND CAN BE SPECIFIED TO FIT YOUR NEEDS NO. 9 LONG DISTANCE TYPE (FOR HIGH TEMPERATURE & PRESSURE) THE DIAPHRAGM IS INSTALLED IN THE BOTTOM FOR EASY CLEANING. APPLICABLE FOR HIGH PRESSURE UP TO 1000KG/CM2. LONG SHAPE OF THE DESIGN CAN HELP TO LOWER DOWN THE TEMPERATURE TO PROTECT THE MEASURING INSTRUMENTS; OPERATING TEMPERATURE IS AVAILABLE UNDER 330. - 8 -

DIAPHRAGM PRESSURE GAUGES Connection Sealed Type No. 3 & Separable Type No. 4 APPLICATIONS Diaphragm pressure gauges are used when medium is corrosive, contaminated, viscous or with particles. Type No. 3 & 4 series are particularly used in chemical and petrochemical industry, mechanical engineering, plant and apparatus construction. SPECIFICATIONS Instruments: All series pressure gauges and pressure transmitters are available Connection (Thread) 1/4 ; 3/8 ; 1/2 ; 3/4 ; 1 PT / NPT, male or female thread Upper diaphragm Housing SS304 standard, SS316 available Diameter Ø70 & Ø90 mm Lower diaphragm Housing SS304 ; SS316 Diameter Ø70 & Ø90 mm Diaphragm SS316 standard Screws on housing SS304 standard, other materials available made-to-order Temperature medium +80 Filling fluid Glycerin or silicon oil standard Pressure ranges General type: 0 / 0.6 ~ 0 / 60 kg/cm2 (bar), positive, negative or compound - 9 -

FREON PRESSURE GAUGES, COMPOUND GAUGES MATERIAL AND WELDING METHOD USED CAN OBTAIN EXCELLENT LEAKING-PROOF, PRESSURE IMPULSE-PROOF AND VIBRATION-PROOF EFFECTS. SUITABLE FOR AIR CONDITION SYSTEM R12, 22, 502, R134. DIAMETER = BOTTOM CONNECTION: 2.6", LIQUID FILLED TYPE: 2.5" BACK CONNECTION : 2.5" CONNECTION = BOTTOM CONNECTION :1/8" NPT BACK CONNECTION = 7/16 " UNF PRESSURE RANGE = LOW PRESSURE = -76 cmhg ~0~250psi (15kg/cm 2 ), HIGH PRESSURE = 0~500 psi (30 kg/cm 2 ) MATERIAL = CASE & BEZEL: PLASTIC, STEEL, STAINLESS STEEL. WETTED PARTS : BRASS. ACCURACY = 1.5%F.S. - 10 -

NEEDEL VALVE NEEDLE VALVES ARE USUALLY USED IN FLOW METERING APPLICATIONS, ESPECIALLY WHEN A CONSTANT, LOW FLOW RATE MUST BE MAINTAINED FOR SOME TIME. A NEEDLE VALVE ALLOWS PRECISE REGULATION OF FLOW AND AS ITS ORIFICE IS SMALL AND THE FORCE ADVANTAGE OF THE FINE-THREADED STEM IS HIGH, NEEDLE VALVES ARE USUALLY EASY TO SHUT OFF COMPLETELY. MATERIAL: SS316. PULSATION DAMPNER PULSATION DAMPNERS ARE USED IN LINE WITH A PRESSURE GAUGE TO SUPPRESS LINE PULSATIONS AND KEEP THE POINTER STEADY. DAMPNERS CONSIDERABLY REDUCE THESE PULSATIONS AND MAKES THE GAUGE READING EASIER AND ALSO IMPROVES THE LIFE OF THE GAUGE. MATERIAL: BRASS SYPHON TUBE THE SYPHON TUBE IS CONNECTED BETWEEN THE PRESSURE GAUGE & PROCESS IN APPLICATIONS WHERE HIGH TEMPERATURE VAPORS, STEAM OR FLUIDS ARE PRESENT. IT ACTS AS A COOLING COIL AND PROTECTS THE GAUGE FROM HOT PROCESS MEDIA AND ALSO REDUCING THE EFFECT OF RAPID PRESSURE SURGES. MATERIALS: BLACK STEEL OR ZINC PLATED. - 11 -