Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Similar documents
This section applies to the design and installation of transformers.

SECTION SUBSTATION TRANSFORMERS

Secondary Unit Substations

Low Voltage Transformers Sealed, General Purpose, Dry Type

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

SECTION DRY-TYPE TRANSFORMERS

Distribution Dry Type Transformers

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Unit Substation Transformers

600 Volt Class Transformers

Presentation of the France Transfo factories

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Primary and Secondary Electrical Distribution Systems

Transformer Design & Design Parameters

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

Multi-tap Transformers

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Receiving, Installing, Operating and Maintaining Dry Type, VPI Sealed, Cast Coil and UNICLAD Transformers

Distribution Dry Type Transformers

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

2.2 NEMA Premium and E3 Super Efficient Transformers NEMA Premium Efficient Transformers... E3 Super Efficient Transformers...

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Lightning Arresters P KVA P KVA. Description & Installation

Single Phase Three Phase Single Phase Export Model Transformers Single Phase Buck and Boost Transformers Stainless Steel Enclosed Transformers

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Distribution Voltage Regulators

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

DRY TYPE TRANSFORMER

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Explosion-Proof Electric Unit Heaters

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Transformer Manufacturing Processes

Medium Voltage Electrical Distribution

Generators TEM. for small hydroelectric power stations. Electric Machines

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Table of Contents. TransformerIQ FAQs 1

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

Fusible Disconnect Switch

Single Phase Soft Starter

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

TRANSFORMER DICTIONARY

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components


CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

SECTION HEAT PUMPS

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Transformer Questions & Answers

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Power Plant Electrical Distribution Systems

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Data Center Solutions. Envirotran HDC Transformers Deliver Superior Reliability and Efficiency for Substantial Savings Everyday

Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators

ECOCIAT. Domestic hot water heat recovery unit

Enhanced Quality with a Touch of Style

Sample - No Commercial Use

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Split System Cooling Product Data

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

Instructions for Secondary Unit Substation Transformers KVA, Three Phase

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Some important Indian Standards related to Transformer are as follows:

WINDING RESISTANCE TESTING

A. Shop Drawing submittals shall include, but not be limited to, the following:

Evaluating Water-Damaged Electrical Equipment

Rotary Phase Converters

Atlanta Chapter IEEE Industry Applications Society

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

S Y N C H R O N O U S G E N E R A T O R S

ELECTRIC HEATER COMPANY Operating and Maintenance Manual For Immersion Heating Elements

Variable Transformers Product Design & Engineering Data

Engineers Edge, LLC PDH & Professional Training

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

ACME ELECTRIC CORPORATION PDPD-01

Buck - Boost Transformers

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

Split System Heat Pump Product Data

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

HP switch LP switch Discharge thermo Comp. Surface thermo

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

GUIDE FOR TESTING POWER TRANSFORMERS

Arc Terminator Active Arc-Resistant Switchgear

Evaluating Fire- and Heat-Damaged Electrical Equipment

LOW-VOLTAGE CURRENT TRANSFORMERS

INFRARED RADIANT HEATERS. air heaters

Transcription:

Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class

GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial plants, commercial buildings and any place requiring safe and dependable power. Ventilated dry-type transformers offer an economical solution and are extremely reliable when properly installed and maintained. General Construction Coils are vacuum-pressure-impregnated (VPI) with solventless polyester resin, ensuring complete impregnation of the windings and insulation. The finished VPI coils are incredibly strong, readily dissipate heat and are protected against moisture, dirt and most industrial contaminants. Ventilated dry-type winding designs vary depending on the voltage, basic impulse level (BIL) and current of the individual winding and/or application of the transformer. For all units, the insulation system will be 220 C regardless of the average winding rise. Vent Dry Transformer; standard arrangement, (HV left) with forced air cooling Safe, Convenient and Environmentally Sound Installations of ventilated dry-type transformers do not require a liquid confinement area, automatic fire extinguishing system or fire vault. Dry-type transformers use no insulating liquids, virtually eliminating the risk of local environment contamination and simplifying routine maintenance by eliminating the need to check, replace or clean liquid. Dry-type units are relatively lightweight and can be conveniently installed on upper floors, balconies, roof trusses or roofs. Insurance companies generally offer lower premiums for installations of dry-types than for liquid-filled transformers. Core and Coil internal assembly

Coils Generally, low voltage (LV) windings less than 2,400 volts are either multi-conductor barrel or sheet conductor types. Multi-conductor windings may be more economical and preferred in smaller kva low voltage applications in which the current and axial short circuit forces are relatively small. High voltage (HV) windings 2,400 volts or greater may be single-section barrel, multi-section barrel or disk types. Ventilated dry-type coils may be either round or rectangular through about 2,000 kva. Transformers larger than 2,000 kva generally are designed with round windings unless there are special considerations, such as limiting dimensions. Enclosure The standard indoor enclosure is NEMA 1, Category C construction. Enclosures are suitable for lifting, jacking, rolling or skidding with provisions for lifting from the transformer base. High voltage and low voltage ANSI ground pads are provided. The enclosure paint finish is neat, clean and highly resistant to corrosion. Metal surfaces are thoroughly cleaned of scale, oil, grease, rust and other foreign matter before painting. Unless specified otherwise, paint color shall be ANSI 61 (light gray). NEMA 3R outdoor enclosures are available for applications that prohibit indoor installation. Cores The transformer cores are constructed of non-aging, high grade, grain oriented silicon steel laminations with high magnetic permeability. Magnetic flux densities are kept well below the saturation point. Core laminations are free of burrs and stacked without gaps. Mitered and step-lap construction cores may be provided when specified. The core clamping brackets are designed to provide even distribution of clamping forces to the core yokes and legs. The core is electrically isolated except for the factory-installed core ground strap, which provides a single path from the core to ground. Outdoor NEMA 3R enclosure

Forced Air Cooling All units rated 750 kva and higher have provisions for adding fans, including capacity in all currentcarrying parts for the fan-cooled rating and capability to add a thermometer relay to control fans. When specified, the transformer shall be provided with fans to give a forced air-cooled rating of 33% above the self-cooled rating. Control wiring (wire markers included), a thermal sensor and a fan controller will be supplied. Vent-Dry Sound Levels: (db) Equivalent Self- Fan- Two Winding Cooled Cooled Base kva db db 500 60 N/A 750 64 67 1000 64 68 1500 65 69 2000 66 71 2500 68 71 3000 68 73 Product Coordination When specified, transformers can be close-coupled to a multitude of GE equipment, including but not limited to Power Break, AKD-8 Switchgear, POWER/VAC Switchgear, Limitamp Motor Control, SCP Switchboards, Spectra Series Switchboards, AV Switchboards, Motor Control Centers, Spectra Series Busway, and Medium Voltage Load Interrupter Switchgear (MVS). Typical Close-Coupled Reverse Arrangement (HV on Right) Load-Center Unit Substation with Ventilated Dry-Type Transformer Three-Phase Temperature Monitor Audio Sound Levels The transformer shall be designed to meet or exceed ANSI and NEMA sound levels for dry-type transformers. As an option, transformers designed at -3dB below ANSI and NEMA standard sound levels are available. x LV Outgoing Section x Transformer Section x HV Incoming Section x

Ventilated Dry-Type Case Outline Shown with High Voltage and Low Voltage Air Terminal Compartments HV ATC LV ATC H D W Approximate Enclosure Dimensions and Weights Based upon 15kV class, 150 C rise. Al windings kva Height Width* Depth Weight Inches Inches Inches lbs 225 90 56 50 2,350 300 90 56 50 2,650 500 90 64 50 3,950 750 90 72 50 4,650 1000 90 72 50 5,800 1500 90 90 50 8,100 2000 90 90 50 9,500 2500 100 100 60 10,650 3000 100 100 60 12,350 *Add 18 to width for each ATC. NOTES: 1. Coordination to GE Equipment may require Transition/Throats. Width may increase up to 42. 2. Depth dimension may increase approximately 4 to 8 each for outdoor NEMA 3R enclosures. 3. Dimensions may vary with special requirements. 4. Dimensions and weights are subject to change without notice and should not be used for construction purposes.

Dry-Type Standard Features Vacuum Pressure Impregnated (VPI) windings 80, 115, 150 C average winding rise ratings 60 Hz operation 220 C insulation system Aluminum or copper windings ANSI ground pads Core ground strap Indoor ventilated enclosure - NEMA 1 Paint ANSI 61 finish Provisions for future fans (750 kva & up) Provisions for lifting Removable front and rear panels Vibration isolating pads (2) 2 1 / 2 % full capacity taps above and below nominal Dry-Type Accessories or Options Electrostatic Shield Enclosure hinged panels Enclosure knockdown Fans for 133% FA kva rating Future fan wiring and control Ground bus - full length copper Impact indicator - Mechanical Outdoor enclosure NEMA 3R Paint polyurethane overcoat Screened ventilation openings Space heaters Temperature monitor/fan controller Thermostat for space heaters UL listing Special Design or Application Low loss designs Rectifier transformer designs Special ambient designs High overload capacity designs Special/low sound level designs 50 Hz designs Seismic zone IV designs Five-legged core designs Series/parallel windings HV Wye connection to LV Delta Retrofit to specific dimensions K-factor ratings Special Paint Testing Each transformer shall receive the following standard production tests in accordance with ANSI C57.12.90 Resistance test Polarity & phase relation test Turns ration test No-load loss & exiting current test Impedance and load-loss test Applied potential test Induced potential test Test results, when requested, are available by transformer serial number. In addition, the following special tests can be performed on each transformer in accordance with applicable ANSI standards at an additional cost. Temperature test Impulse test Sound test Insulation power factor test Partial discharge test Vent-Dry Basic Impulse Ratings Nominal Standard Option System HV BIL HV BIL LV BIL Voltage kv kv kv kv 1.2 10 30 10 2.5 20 30, 45 20 5.0 30 45, 60, 75 30 8.7 45 60, 75, 95 N/A 15.0 60 75, 95, 110 N/A For additional information contact your local GE Electrical Distribution and Control Salesperson. MGM Transformer Company 5701 Smithway St, Commerce, CA 90040 1997 MGM Transformer Company