DC Series Digital Conversion Alarm Operator s Manual



Similar documents
Installation & Operating Instructions for DU / DC Series Area, Master & Combination Alarm Systems

IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION

Before installation it is important to know what parts you have and what the capabilities of these parts are.

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

with installation dynafact boost GAUGE this manual is for use with systems

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

WAYNE-DRESSER HARMONY SERIES DISPENSER RETROFIT for HEALY SYSTEMS, INC. MODEL VP1000 VAPOR RECOVERY ASSIST SYSTEM OUTLINE

1998½-2007 Dodge Ram 5.9L Cummins

Installation Instructions

INSTALLATION INSTRUCTIONS

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

INSTALLATION INSTRUCTIONS

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

HM-W536 Install Guide

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

GEET Fuel Processor Plans

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

OPL BASIC. Dosing System for Professional Laundry machines. Contents

FTC DIY Mountain Build Guide

Part Name/Description Part Number Quantity. Power Cable

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

Installation Instructions

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

MGB Chrome Bumper Conversion

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

INSTALLATION INSTRUCTIONS BL-8704

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec

2003/2004/2005 TOYOTA COROLLA

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Seismic Installation for Attic Storage System

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Cooktop Low-Profile Ventilation Hoods

123 Industrial Loop Road Paynesville, MN Phone:

Fan, Cypress / GreenField Installation Instructions (sku )

Installation Guide for Artic Air 24 Volt R134A Air Conditioner

Porter Instrument Division

Manual for Fire Suppression & Methane Detection System

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

OHIO MEDICAL CORPORATION. Medical Gas Outlets. Installation and Maintenance Manual

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

CoolWave r 2 Phase Control Board and Cable Replacement Kits

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

HEAT WAVE DUCT KIT KIT #

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Your safety and the safety of others are very important.

INTRODUCTION INTERLOCK KIT K-8110

For 100 Amp Automatic Transfer Switch/Load Center Models: 10 Circuit, 12 Circuit and 16 Circuit. Installed with 7, 10, 13 and 16kW Generators.

Operating & Maintenance Manual. Alert-2 Microprocessor Based Digital Alarm System v5.9

Guidelines for Earthquake Bracing Residential Water Heaters

INSTALLATION INSTRUCTIONS MK-8704

Model 2300DR Installation Guide

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

Self Purging Liquid Trap (SPLT ) User s Manual

Part Number:

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

HEAVY DUTY STAIR LIFT SYSTEM Installation and Service Manual

FG MOISTURE MONITOR Installation & Operation Manual

Guidelines for Earthquake Bracing of Residential Water Heaters

Combustible Gas Transmitter RK-05

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

INSTALLATION INSTRUCTIONS

COMMERCIAL GAS DRYER

Installation Guide for the TJ LCG PRO Suspension System (Low Center of Gravity) Available 4 or 5

Generator Transfer Switch Model # HTS15-AUTO

VOYAGER 570G. 744A Sprayer Control

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Flextec 450 PARTS LIST FOR RETURN TO MAIN INDEX

Control Box Wiring For PRSstandard Tool

FRONT TURN SIGNAL RELOCATION KIT

Spill Containment Manholes

Installation Instructions S

Installation Instructions For Slider Casement Air Conditioners

Connecting the Channel A

Installation Guide 2010 BMW S1000RR Full Exhaust System

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Malibu Monte Carlo El Camino

Repair Parts/Beacon Medaes/Area Line Pressure Alarm

5800 Temperature Sensor Cable Assembly

MICROPROCESSOR BASED DIGITAL ALARM SYSTEM

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Advantium 2 Plus Alarm

MP8000 Series Pneumatic Valve Actuators

DC400 Dispensing Cutoff System

R O A D M A S T E R, I N C.

Transcription:

DC Series Digital Conversion Alarm Operator s Manual Ver. 2012 - Rev. 1004 Class 1 Inc. design manufacture installation service world class innovation Call us for your next project.

Area Alarm Conversion Kit Installation Instructions Operator s Manual This product has been designed to convert an existing area alarm to a Tri-Tech Medical Inc. area alarm. Installation of this kit involves the removal of the existing alarms front panel, power supply, and transducer(s). Installation also involves installing a flange, power supply, transducers and alarm front panel and making the necessary plumbing and electrical connections. All installation and testing should be done in accordance with NFPA 99 or CSA Z7396.1-06. WARNING: Installation of this product requires the temporary shut down of medical gases to the affected area of the medical facility. All medical gases supplying the alarm to be converted must be shut down until the conversion is complete. It is the responsibility of the installer to obtain approval from the proper facility personnel before beginning this conversion. WARNING: Electrical power supplying the alarm to be converted should be disconnected prior to beginning this conversion. WARNING: This device should only be installed by qualified personnel. Installation should not be attempted by anyone not having general experience with the installation of devices of this nature. Locate the medical gas zone valve box providing service to the area alarm to be converted. After approval has been granted by the proper facility personnel, close all gas valves providing service to the area alarm to be converted. Disconnect electrical power to the area alarm to be converted. Note: This manual illustrates the conversion of an Ohio area alarm. There are many other models of area alarms that may also be converted and there will be differences in the kits used to convert them. Remove the existing front panel, power supply and transducers. Note: Gas labels corresponding to the gas services being monitored have been placed on the wall adjacent to the alarm before disassembly. This is to help prevent a possible mismatching of gas services during the conversion. These labels will be covered when the alarm is converted. Note: the transducers may be located in the back box or remotely in the ceiling or remotely located in Tri-Tech Medical zone valve boxes as shown here). Note: If the transducers are to be installed remotely, see Appendix F of the DU/ DC Installation & Operating Instruction Manual for the proper techniques to wire remote transducers.

The Ohio area alarm (pictured here) must be disassembled from the bottom module up. Note there is a short hose connected to a Hanson quick connect coupling that must be disconnected in each gas module. There is also an electrical plug connector on each gas module that must be disconnected. Remove existing power supply from back box If the gas connection fittings are not DISS gas specific demand valves, they must be removed. In this conversion the Hanson couplings should be removed. When the fittings are removed the remaining fitting in most cases will be either a 1/8 or a ¼ NPT Female thread. In some conversions, the threads are flare fittings and adaptors are provided as part of the conversion kit. Special adaptors provided with conversion kit. The demand check valve fittings are stamped with either the abbreviated gas name or the chemical symbol of the gas. Take special note as to which gas service is being provided by each gas riser as they may not be labeled on the back box as shown here. If they are not labeled or marked, do so now. The special adaptors which have been included must be used. In some cases, there is insufficient clearance for the poppet in the demand check to open allowing gas to flow. These adaptors provide sufficient clearance to allow the demand valves to operate properly when engaged with mating fittings.

In this photo the adaptors and demand valves are installed. Install the transducers onto the demand valves. This photo shows all of the transducers installed. The power supply comes pre-installed on the flange. It may not be installed on the flange in the correct position to allow it to fit into the backbox. If necessary, the power supply may be removed from the flange (2 screws) and repositioned on any of the 4 sides of the flange. Pre-drilled and tapped holes have been provided. Position the flange with the power supply into the back box. The flange must cover the back box and the power supply must recess into the back box. As long as these requirements are met, the flange may still provide extra coverage and allow for centering as desired. Warning: The wall prints should be checked for power, water or other service lines that may be installed. After the desired position of the flange has been chosen, holding the flange assembly in place, mark the four hole positions on the wall. The four holes are located near the corners of the flange. It is recommended that a level be used.

Temporarily hold the flange in the desired position and mark the wall (thru the holes that are located near the corners of the flange). Remove the flange and drill the 4 holes using a 3/8 bit. CAUTION: The molly bolts provided can be used for wall thicknesses of 5/8 to 1 ¼. If wall thickness is outside this range another type of wall anchor must be used. Install the molly bolts (provided) into the four drilled holes. Tighten screws until snug. DO NOT OVERTIGHTEN. Remove the screws & washers. Position the flange assembly onto the back box lining up the flange mounting holes with the mollies. Thread the molly screws with washer thru the flange into the mollies and tighten. The power supply has been pre-wired for 110 VAC. Connect the three wires from the power supply (Black = Line, White = Neutral & Green = Ground) to the proper incoming 110 VAC wires using wire nuts.

The wire terminal connector on the gas board has six wire connection slots. The two wires from the transducer should be installed in the BLK & WHT SENSOR slots. These are the two slots closest to the center of the gas board (as shown). It is preferred that the black wire be closest to the center of the gas board. The transducer plug may be removed from the gas module to make it easier to install the wires. Attach the green ground wire, which is in the wiring harness, to the ground screw on the left corner of the front panel just in front of the power supply. Using the self-taping screw provided, attach the green ground wire harness originating from the ground lug terminal on the alarm front panel and power supply mount, to an appropriate grounding point in the back box.

The power supply has been provided with both a removable fuse and an on/off switch to provide for ease of any possible future service work to the alarm or changes to the medical gas piping system. Make sure the fuse is installed and the switch is in the on position. When closing the alarm front, be careful to not pinch any wires between the alarm front panel and the flange. Restore electrical power and medical gases to the converted area alarm. Before the facility restores this portion of the medical gas piping system to patient use, the alarm must be tested for high and low line pressure alarms for all gases (except vacuum & WAGD/evacuation which are tested for low line pressure only) and tested for possible cross-connection to ensure each gas module is monitoring the correct gas. It is recommended that this testing be done by an independent third party medical gas certification company. See the Tri-Tech Medical Alarm Manual for complete instructions on testing and operating the new alarm panel.