Installation & Operating Instructions for DU / DC Series Area, Master & Combination Alarm Systems
|
|
|
- Brandon Moses Byrd
- 10 years ago
- Views:
Transcription
1 Manufacturer of Medical Gas Pipeline Equipment Installation & Operating Instructions for DU / DC Series Area, Master & Combination Alarm Systems Master Alarm Area Alarm Combination Alarm e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
2 Features & Benefits Introduction The Tri-Tech Medical gas alarm system monitors the status of the medical gas distribution system and provides audible and visual indicators. The master alarm can be furnished with building management interface circuit board(s) to communicate all master alarm/status information to the building management system. The alarm can be used in conjunction with the Tri-Tech Medical T-Net system to monitor the status of all T-Net equipped alarm and manifold systems on a PC. The Tri-Tech alarm system monitors the status of the medical gas sources in accordance with NFPA 99 and CSA Z Features & Benefits Microprocessor controlled State of the art maintenance free electronics provide excellent reliability. Easy to program One man adjustable digital pressure display (at the panel, not the transducer) Remote signal modules Each circuit board provides monitoring of 16 separate remote devices. Self test program alarm code display LED display reveals the nature of the malfunction and reduces maintenance time. Three year PC board warranty A quality product you can buy with confidence. Independent multiple master alarms When service is interrupted to one alarm the other(s) continue to operate independently. Transient signal filter Prevents or reduces nuisance (false) alarms signals (less than 0.7 seconds) created by EMI /RFI interference. Audio & visual signal indicators Audible alarm and visual display of both normal and abnormal status of each signal monitored assures prompt and informative indication of a problem. Optional building management interface circuit board(s) MCP boards Allows communication of remote signals (master alarm points) with building management system. Easy to install and service Hinged frame with lanyards for easy accessibility. Dry remote signal contacts (high & low) for each gas module Dry contacts are provided so that both the high & low line pressure alarms may be remotely wired to a remote or master alarm. Programmable remote signals (Master Module) Configure each remote signal independently (either normally closed, normally open or turn unused signals off). Digitized transducers Allow remote locating of transducers up to 5,000 feet away from alarm panel. Extremely resistant to RFI. Programmable gas module high and low set points Pre-programmed from factory at 60/40 psig for 50 psig delivery pressure gases, 200/140 for N2 and 12 in Hg for Medical Vacuum & WAGD/EVAC. Programmable in 0.5 psig or In Hg increments from 0.5 psig or In Hg up to 30 In Hg or 100 psig or 250 psig (depending on which type of transducer is used). Compact unit Requires minimal wall space. Monitors up to 14 area alarm signals or 64 remote (master) signals in one 5 slot panel. Alarm history recall Can recall previous alarm signals (both area and master alarms) even after the alarm condition has been corrected and the alarm panel has been cleared. Area Alarm repeat feature Adjustable from 1 minute to 240 minutes (factory programmed for 10 minutes. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
3 Contents Tri-Tech Features & Benefits Major components Introduction Alarm Panel Installation Rough-In Box Installation Mounting Wiring Plumbing Front Panel Installation Wiring alarm front to power supply Installing the Transducers Wiring the transducers Remote transducer wiring Wiring the Remote Devices Labeling the Alarm Front Alarm Displays & Functions Component identification Button module displays & functions - 17 Power on indicator Silence button Test button (up) button (down) button (right) button (left) button History button View Alarm History Clear Alarm History Gas (Area) module displays & functions System LED Pressure LED Digital Display Pressure LED Hi/Normal/Low Display- 19 Units of measure LED display Table of Contents Remote Signal (Master) module displays & functions Normal status LED Abnormal status LED Alarm Operation Remote signal (master) module Gas (area) module Silencing the alarm Testing the alarm System alarm/alert & error codes Programming the Alarm Keypad identification Accessing the Program Mode Hi/Low pressure limits Remote Signal Alarm Points Alarm Repeater Delay Units of Measure Display Adjusting the line pressure display Adding/removing modules Board Identification # Adding T-Net Interface Circuit Board Installation Adding Building Management (MCP) Circuit Boards & Wiring Appendix A Glossary of Terms Appendix B Alarm Specifications Appendix C Signal Wire Color Code Log - 30 Appendix D Wiring Diagram Appendix E Source Equipment wiring Appendix F Remote Transducer wiring Terms & Warranty Technical Assistance or e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
4 Introduction / Components Rough-in box or back box Front panel or front Riser assemblies (for installing transducers in alarm back box) Hinges and screws for attaching front panel to back box Transducer assemblies e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
5 Introduction / Components Introduction The Tri-Tech Medical gas alarm system monitors the status of the medical gas distribution system and provides audible and visual indicators. The master alarm can be furnished with MCP building management interface circuit board(s) to communicate all master alarm/status information to the building management system. The alarm can be used in conjunction with the Tri-Tech Medical T-Net system to monitor the status of all T-Net equipped alarm and manifold systems on a PC. The Tri-Tech alarm system monitors the status of the medical gas sources in accordance with NFPA 99 and CSA Z The Tri-Tech Medical gas alarm system is a two or three section assembly comprised of a rough-in box, a front panel and transducers (only if it is an area alarm or combination alarm). Rough-in box The rough-in box houses the power supply, fuse, on/off switch, and a terminal strip for electrical wiring. An isolated transformer reduces the 110V or 220V AC input to low voltage DC. Front panel The front panel includes enclosed printed circuit boards with programming circuitry. The Push Button module includes a power on indicator, programming buttons and an audible alarm. The Remote Signal module(s) can monitor up to 16 signals per circuit board. Multiple remote signal modules can be ordered in a single alarm. The signals can be configured to display an abnormal condition on either a normally closed (NC) or a normally open (NO) circuit. Each signal may also be turned off if it is not being utilized. The Remote Signal module(s) with MCP are equipped with all of the above described features as the standard Remote Signal module(s) described above. In addition, the remote signal module(s) with MCP are equipped with an extra set of remote signal dry contacts to interface with a building management system. The Gas (Area) module(s) on the front panel are identified with gas specific, color coded labels (per NFPA 99 or CSA Z7396.1). The gas displays include LED s which indicate high/normal/low pipeline pressure. A digital LED display shows the actual gas pressure. The gas pressure may be displayed in PSI and In Hg, or BAR or kpa. The unit is pre-programmed to display PSI / In Hg from the factory, but may be re-programmed in the field to display BAR or kpa. In addition there are LED s which illuminate to indicate System and Program failures. Each module is supplied with dry contacts for remote signaling of high and low pipeline pressure. Transducers The transducer converts pressure to an electrical signal and supplies the electrical signal to the alarm circuit board Gas module panels. After the initial 24 hour 150 psi standing pressure test (required per NFPA 99) has been completed the pressure/vacuum transducers may be connected to the medical gas pipeline. The transducers may be remotely attached to the piping system at distances up to 5,000 feet using standard 18 gauge stranded twisted pair wire. Tri-Tech Medical recommends mounting the transducers in the zone appropriate zone valve box (utilizing the Tri-Tech Medical E Z Backfeed and E Z Find features) or in the alarm back box. Should a transducer require service or replacement it is considerably more of a safety issue and more time consuming to locate and replace transducers which have been remotely located above the ceiling and eliminates contamination issues such as having to set up a tent in order to remote ceiling tiles. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
6 Alarm Installation Alarm Installation Installation of the Tri-Tech Medical alarm involves installing the rough-in box, the risers & the transducers (if it is an area alarm or combination alarm) and front panel and making the necessary conduit, plumbing and electrical connections. All installation and testing should be done in accordance with NFPA 99 or CSA Z WARNING: Electrical power intended for the alarm to be installed should be disconnected prior to installation. WARNING: This device should only be installed by qualified personnel. Installation should not be attempted by anyone not having general experience with the installation of devices of this nature. Rough-In Box Installation This is a rough-in box for a combination alarm. Your rough-in box should look the same or similar to this unit. The risers are shipped loose, for protection during shipment, and must be installed. If transducers are to be mounted remotely, it is recommended that they be connected to the DISS demand check valves installed in the corresponding zone valve box equipped with the Tri-Tech E Z Backfeed and E Z Find features. Refer to the building plans to determine the location of the alarm. The contractor is to provide rigid mounting that will support the alarm box on both sides. The metal flanges provided on both sides of the rough-in box are to rest against the rigid mounting brackets. Screws (contractor provided) are to be driven thru the holes in the metal flanges into the mounting brackets. Flanges are adjustable to allow for a drywall depth of 1/2 to 1 1/8. Mount alarm rough-in box so it will be flush or just below the finished wall surface using the adjustment feature on the flanges. (Side/end view of rough-in back box) e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
7 Alarm Installation The power supply hole is located in the bottom (left side) of the rough-in box. Remove the plaster cover and panel covering the power supply. Remove the plug from the hole. Make conduit connections for wiring from the facility emergency power source. To remove the power supply cover, loosen the two screws at the top of the cover and slide the cover to the right, then lift the cover over the screw heads. Slide the wiring harness strain relief to the left until it is free from the cover. Wiring Use either of the two ½ conduit knock-outs provided on the lower left side and bottom of the rough-in box to route conduit to supply either 120 or 240 VAC to the power supply. Note: Separate conduit should be used for low voltage wires (use knock outs provided on the top of the box). Neutral Line (Hot) Field Ground Route wires through the power supply conduit installed in the bottom and left side of the roughin box. Connect the 120 or 240 VAC facility emergency power source electrical wiring to the terminal strip provided on the lower left side of the box. (N = neutral, L = Line (hot), FG = field ground) e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
8 Alarm Installation The wiring harness will be provided pre-wired to the power supply. If by chance you are replacing a wiring harness, the single green ground wire should be fastened to the screw on the top left corner of the power supply board. The wiring plug in connector (which should contain the rest of the wires), plugs into the connector terminal on the upper left corner of the power supply board. The black wire will be on the top. This is how the power supply should look when the wiring is completed. Replace the power supply cover and plaster cover (to protect the unit while the drywall and wall covering work are being done) after wiring is complete Plumbing the Riser Extension Tubes Riser extension tubes Install the risers in the top of the back box as shown. After removing the protective plastic caps, connect the riser extension tubes to the gas piping system per NFPA 99. Make sure the drop is for the proper gas service. Using a purge gas to insure cleanliness in the tubes, silver braze the joints. Do not use soft solder. Conduct heat away from the check valves. (A purge kit is required for purge equipment connection to the system). The 150 psi standing pressure test of the piping system must be successfully completed and all pressure removed from the system before connecting the transducers to the system. Attaching transducers without depleting the 150 psi standing pressure first will result in damage to the transducers! Note: It is recommended that gas piping system tubing be connected from the extension tube to the ceiling for a future or blank gas display even though a transducer is not being installed. Cap the unused tube above the ceiling. This will simplify future expansion. Note: It is also possible to install the transducers remotely (not in the alarm box). In this type of installation the risers are connected to the gas piping system up to 5,000 feet away from the alarm panel. Note: Tri-Tech Medical recommends mounting the transducers either in the zone valve box (remote) in conjunction with the E Z Backfeed and E Z Find products or in the alarm back box not remotely above the ceiling. Should a transducer require service or replacement it is considerably more time consuming to locate and replace or service transducers remotely located above the ceiling. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
9 Alarm Installation Installing the Hinges After the walls are finished, the hinges may be installed onto the rough-in box. The two hinges should be fastened to the lower front edge of the rough-in box using the screws provided. The hinge should rest flat against the surface of the drywall. Installing the Alarm Front Panel Slide the rectangular holes cut into the bottom edge of the front panel over the front catch of the hinges. Support the front panel in the open position to attach the lanyards. Attach the two (left & right side) lanyard cables to the alarm front panel using the screws provided. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
10 Alarm Installation Wiring the Alarm Front Panel to the Power Supply Attach the green ground wire, which is in the wiring harness, to the ground screw on the left corner of the front panel just in front of the power supply. Attach the plug connector at the end of the wiring harness to the appropriate connector located at the top left corner of the button module circuit board. The plug should lock into place. The plug can only be inserted one way. This is how the wiring harness plug connector should look when properly installed on the back of the button module board. Installing the Transducers (non remote) After depressurizing the 150 psig standing pressure from the piping system, install the appropriate transducers to the appropriate riser extension tube connectors inside the rough-in box. Hand-tighten then torque lightly with a wrench. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
11 Alarm Installation Installing the Transducers (remote) Transducer assemblies with DISS gas specific fittings have also been provided and, after the 24 hour standing pressure test is completed and normal operating pressure has been restored to the medical gas piping system, they must be connected to the DISS demand valves. Note: maximum mounting distance of each remote transducer is 5,000 feet away from the alarm panel to which it will be wired. Follow the wiring instructions in Appendix F. The transducers have been designed so that they may be installed in a standard 4 x 4 x 2 1/8 electrical junction box for added protection. A panel mount feature has been provided to allow mounting of the transducer using standard 1/2 conduit connections and 4 x 4 x 2 1/8 junction boxes. Note: The DISS nut & nipple will need to be removed to allow installation of the conduit nut and then re-installed using oxygen safe Teflon tape. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
12 Alarm Installation Connecting the Transducer Wiring to the Alarm Front Circuit Board The wire terminal connector on the gas board has six wire connection slots. The two wires from the transducer should be installed in the BLK & WHT SENSOR slots. These are the two slots closest to the center of the gas board (as shown). It is preferred that the black wire be closest to the center of the gas board. The other four connection slots are for optional remote signals of the low and high line pressure alarms. The transducer plug may be removed from the gas module to make it easier to install the wires. Visually verify that the appropriate transducer wire pair has been attached to the appropriate gas module by looking at the front of the alarm panel. If there is not an Error Condition and a System alarm, the proper (matching gas service) transducer has been connected to the gas board. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
13 Alarm Installation Wiring the Remote Devices to the Remote Signal (Master) Board Locate the two banks of 16 terminal connectors on the back of the remote signal (master) board. There are a total of 32 connection points two connection points for each remote signal. The pairs are labeled 1 IN thru 16 IN on the circuit board. The NC (normally closed) labeled terminal of each pair is where the signal wire should be landed. The connector terminal may be unplugged from the circuit board to simplify installation of the remote signal wires. Remote signal #1 signal wire (white) Remote signal #1 common wire (black) Land the corresponding common wire on the C (common) terminal of each pair of terminal connectors. Remote signal #2 signal wire (red) Remote signal #2 common wire (green) e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
14 Alarm Installation Labeling the Alarm Front After all remote signal (master) wires have been landed, identified & cataloged (using appendix C in this manual), you are ready to apply the remote signal labels. Remove by unthreading the two nylon nuts shown here from the back of the alarm front panel. The panel will now lift out of the white frame. Provided in the packaging with the alarm front panel is a long white card and a pre-printed sheet of labels for the remote alarm signals. Wash your hands before handling these labels and cards! Apply the labels to the appropriate position on the card using the guide lines on the card. When complete, insert the card into the Monitored Signals label pocket of the Monitored Signals label. The gas modules are shipped pre-labeled from the factory. If a gas service is changed to a different gas or added to the alarm, it will be necessary to insert the appropriate label in the pocket of the gas module. The new gas label supplied by Tri- Tech Medical will slide into the gas module label pocket of the gas module label. A blank label has been provided at the bottom of each gas module for room identification. You may type directly onto this label or apply a pre-printed label. The label supplied by Tri- Tech Medical will slide into the gas module label pocket of the gas module label. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
15 Alarm Installation When the labeling is complete, install the plate into the white frame and re-attach with the two nylon nuts. You are now ready to supply power to the alarm. Restore power to the circuit feeding this alarm panel. The toggle switch on the front of the power supply should be placed in the ON position. Check the green power LED indicator on the front of the button module. It should be illuminated. If you haven t already, you are now ready to pressurize the piping system to normal operating pressures. The alarm is shown here with Oxygen & Medical Air at normal operating pressures. All remote signal points (master alarm signals) are shown in normal condition. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
16 Area and Master Alarm Displays & Functions Audible alarm indicator Alarm silence button Programming keypad Color coded gas identification label Power on indicator Gas (Area) Module Alarm test button Room ID label slot Digital pressure display Status code LED s Unit of measure indicators PSI, In Hg, Bar or kpa Programming keypad Alarm silence button Audible alarm Remote signal (master) description label Power on indicator Alarm test button Remote signals abnormal status LEDs - Red Remote signals normal status LEDs - Green Programming display for remote signal (master) circuit board e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
17 Alarm Displays & Functions Alarm Displays & Functions Button Module Power on Indicator The power on indicator (green LED) is illuminated whenever electrical power (120 or 240 VAC) is connected to the alarm and the on/off switch is turned on. Test Button When the Test button on the front panel is pressed, the alarm illuminates all segments of all lights and LED s and sounds the buzzer. Alarm Silence In the event of an alarm condition an audible alarm sounds. The audible alarm can be silenced by pressing the alarm silence button. The high or low pressure LED or the remote signal LED will remain illuminated until the alarm condition is rectified. If a Gas module (area alarm) had alarmed, depressing the silence button will silence the alarm for approximately 10 minutes (factory setting). After approximately 10 minutes, the audible alarm will sound again. History Button The History button may be pressed and held at any time to view alarm history. Viewing alarm history is only active while the History button is pressed, releasing the button returns the alarm to normal operation. Pressing the History Button will display the following: Gas(Area) Module - If there was an alarm condition for any gas (area) module, the High and/or Low Pressure LEDs will be illuminated. If both the High and Low Pressure LEDs are illuminated, the gas has had both a High and Low alarm. Remote Signal (Master) Module If there was an alarm condition for any Remote Signal the Red LED will be illuminated. All other LED s will be off. Clear Alarm History To clear alarm History you simply press the History button, hold it down and simultaneously press the Clear button. (up arrow) The up arrow may be pressed & held at any time to display the high line pressure alarm set points of the gas module (area) boards. When in the program mode, the up arrow is used to raise the high line pressure alarm set point on gas module (area) boards and to toggle between your choice of Green condition, Red condition or Disabled condition on remote signal (master) boards. (down arrow) The down arrow may be pressed & held at any time to display the low line pressure alarm set points of the gas module (area) boards. When in the program mode, the down arrow is used to lower the low line pressure alarm set point on gas module (area) boards and to toggle between your choice of Green condition, Red condition or Disabled condition on remote signal (master) boards. (right arrow) The right arrow may be pressed & held at any time to display the gas service for which the gas module (area) board is currently programmed. When in the program mode, the right arrow is used to toggle between the various options of services on the gas module (area) boards and to toggle to the next remote signal point on the remote signal master boards. (left arrow) The left arrow may be pressed & held at any time to display the type of transducer that is connected to each gas module (area) board. The 3 types are 0 30 In Hg, psig and psig. When the left arrow is pressed 30 will be displayed for a 0 30 In Hg transducer, 100 will be displayed for a psig transducer and 250 will be displayed for a psig transducer. When in the program mode, the left arrow is used to save the updated programming information. After the changes have been made and the left arrow is pressed three horizontal lines will appear on the digital pressure display of the gas module being programmed or on the programming display for the remote signal (master) board being programmed. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
18 Combination Alarm Displays & Functions Alarm silence button Programming keypad Clear button Audible alarm buzzer Remote signal (master) module Power on indicator History button Alarm test button Master labels ID slot Color coded gas identification label Gas (Area) Module Room ID label slot Program mode indicator Digital pressure display Remote signals abnormal status LEDs - Red Units of measure indicator PSI, In Hg, Bar, or kpa Status code LED s Remote signals normal status LEDs - Green Programming display for remote signal (master) circuit board e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
19 Gas Module (Area alarms) Pressure Reading Display The LED Digital Pressure Display displays the pressure as indicated by the transducer. The gas pressure may be displayed in PSIG/In Hg, BAR or kpa. PSIG and In Hg is the factory setting. Note: Vacuum & EVAC / WAGD are actually displayed as inches of Hg in the PSI mode. In kpa mode the Nitrogen gas display indicates one tenth of the actual pressure when the pressure exceeds 999 kpa (i.e kpa is displayed as 110 and the kpa and (x 10) LED is lit. Note: Alarm settings are maintained even if power is interrupted. Units of Measure Indicator The Units of Measure Indicator illuminates PSIG/In Hg, BAR or kpa (whichever is selected during programming PSIG and In Hg is factory setting) providing the unit of measure displayed on the LED pressure reading. In the kpa mode the Nitrogen gas display indicates one tenth of the actual pressure when the pressure exceeds 999 kpa (i.e kpa is displayed as 110 and the kpa and (x 10) LED is illuminated). High / Normal / Low Status Lights Should the line pressure of a gas exceed the programmed alarm set points for low or high line pressure, the corresponding low or high line pressure LED will be illuminated simultaneously with the buzzer sounding to announce an alarm condition has occurred. When the line pressure is neither high nor low it is considered within the normal range and the green Normal LED is illuminated. These indications are relative to the high and low pressure set points which have been programmed into the alarm. These high and low set points should be set in accordance with NFPA 99 and CSA Z at 20% of the normal operating pressure. System LED The System LED illuminates in the event of a system problem or malfunction. The following codes will be displayed when a System Error or Failure is detected, or when the History button is pressed: Alarm Displays & Functions Code Error 0 No error (History only) 1 Flash EE corrupt, defaults loaded 2 Sensor: open or broken line 3 Sensor: com timeout, data not received when expected 4 Sensor: Noise on line, or data errors 5 Sensor: Gas type/range mismatch Actual low psig Low pressure (History only) Actual high psig High pressure (History only) Remote Signal Status LED s (Master Module) Normal Status Light (Green) The normal green status light when illuminated signifies that the equipment being monitored is not in an alarm condition. Abnormal Status Light (Red) The abnormal status light when illuminated signifies that the equipment being monitored is in an alarm condition. Note: If no LED is illuminated the remote signal status LEDs have probably been set in the disabled or off position. This can be verified by placing the Remote Signal circuit board in the programming mode and pressing the to view the status of the remote signal point in question or by simply pressing the Test button to verify that the LED s are functional. Program Mode When a circuit board is placed in the program mode (see Programming Modules page 23) the board may be re-programmed. The brightness level of the circuit boards other than the one in the program mode is decreased. In addition, on Gas Displays (Area Modules) the PGM (Program) LED is illuminated, on Remote Signal Displays (Master Modules) the first Remote Signal point will blink e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
20 Alarm Operation Alarm Operation This section deals with the daily operational aspects of the alarm panel. The Programming The Alarm section covers the procedures to follow in order to configure the alarm if the preprogrammed settings are not appropriate, a module is added or deleted or if the alarm is being incorporated into a T-Net system. After installation has been completed and the alarm has been properly configured, it is ready for operation. Master Alarm Panels Remote Signal (Master) Module With electrical power applied to the alarm, it will monitor the status of the medical gas distribution system and the remote equipment connected to it. The remote signals (master) module displays (via LED indicators) the normal/abnormal status of the remote equipment connected to the alarm. All alarm panels are pre-programmed upon leaving the factory to monitor normally closed signals (per NFPA 99). In normal operation all active signals will be green. Whenever an abnormal status signal is detected the corresponding green LED will be extinguished and the red LED will illuminate. Simultaneously an audible alarm will sound. Pressing the Silence button silences the audible alarm (the Red LED continues to be lit). The appropriate personnel should be notified immediately of the alarm condition. When the alarm condition has been rectified the Red LED is automatically extinguished and the Green LED illuminates. Note: master alarm signals do not repeat only area (gas) modules are equipped with the Repeater Delay feature. Silencing the Alarm Press the Silence button when the alarm is sounding and the alarm will be silenced. Testing the Alarm Pressing and holding the Test button initiates a self-test of the alarm. All LED s and seven segment displays will illuminate for as long as the Test button is depressed. In addition the buzzer will sound. If any LED or seven segment display does not illuminate it is faulty and the circuit board should be replaced. If the buzzer does not sound, it is faulty and the circuit board should be replaced. Note: The alarms (both Area & Master) are programmed to ignore transient signals that are less than 0.7 seconds in duration. Area Alarm Panels Gas Modules With the electrical power applied to the alarm and the gas systems adequately pressurized, the following indicators are illuminated: 1) the Power On LED, 2) the pressure readings of the gas on each gas display, 3) the Normal LED (green) on each gas display. If the pressure of one of the gases drops below the programmed low limit setting, the following events take place simultaneously: 1) the Normal LED will be extinguished, 2) the Pressure Low LED (red) will illuminate, 3) an audible alarm will sound. If the pressure of one of the gases rises above the programmed high limit setting, the following events take place simultaneously: 1) the Normal LED will be extinguished, 2) the Pressure High LED (red) will illuminate, 3) an audible alarm will sound. Silencing the Alarm Press the Silence button when the alarm is sounding and the alarm will be silenced. The area alarm is equipped with a Repeater Delay feature which monitors only the Gas Module (Area) alarms. The Repeater Delay has been factory programmed to make the alarm re-sound every 10 (ten) minutes as long as the alarm condition exists. Note: Remote Signal (Master) alarms are not monitored by the Repeater Delay. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
21 Alarm Operation System Alarm The audible buzzer will sound, the System Led will illuminate and an Error Code Err will be displayed on the digital pressure display when a system failure occurs or the history button is depressed. The System LED and Err will illuminate and flash on and off and alternate with a number (per table below) being displayed on the digital display. Note: If Err should be displayed on the Gas Pressure Display of any gas module, this indicates a problem. Some possible problems and corrective actions are: The transducer is not connected to the Gas Module. To correct, check the transducer connection to the back side of the Gas Module. A transducer for a different gas service has been connected to the Gas Module. To correct, check the transducer and the Gas Module gas identification labels and make sure they match. If the above corrective actions do not correct the problem, contact the factory for assistance. Code Error 0 No error (history only) 1 Flash EE corrupt, defaults loaded 2 Sensor: Open or broken line 3 Sensor: Com timeout, data not received when expected. 4 Sensor: Noise on line, or data errors 5 Sensor: Gas type/range mismatch Actual Low pressure (history only) Pressure Actual High pressure (history only) Pressure PGM notification The PGM (program mode) LED will flash off & on when a gas module circuit board is manually placed in the program mode. It is important to note that while a gas module is in the program mode, it is not monitoring the medical gas pipeline. See the Programming the Alarm section of this manual for instructions on programming the gas module. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
22 Programming the Alarm Button Label Up button Toggle button Down button Silence button Test button Save button Clear button History button Gas Board (back view showing dip switch DIP Switch PGM/RUN (only outer switch labeled PGM/RUN should be used) Gas Board Program mode indicator Digital pressure display Units of measure LEDs SYSTEM LED HIGH Line Pressure LED NORMAL Line Pressure LED LOW Line Pressure LED Remote Signal (Master) Board Green LED Normal Remote signal indicators Red LED Abnormal Remote signal indicators Programming Display LED e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
23 Programming the Alarm Programming the Alarm The alarm has been programmed at the factory prior to shipment. Programming of the alarm may be necessary if: a) the high or low pressure limits for a gas need to be modified b) if a future gas module is being put into service for an added gas service c) if a gas service is being deleted d) if a gas service is being changed e) if a remote signal alarm point needs to be re-configured f) if a remote signal module is being added in the place of a blank module g) if the alarm identification number needs to be changed h) you wish to change the repeater delay time i) you wish to change the units of measure from psig and In Hg to either BAR or kpa j) the alarm panel is being set up on the T-Net system Note: Only authorized personnel should program the alarm! It is important to note that while the alarm is in the program mode, it is not monitoring the medical gas system and alarm conditions will not trigger an alarm. Accessing the Alarm Program Mode To program the alarm, the circuit boards must be placed individually, one at a time in the program mode. To place a circuit board in the programming mode, the dip switch located on the back side of the circuit board to be re-programmed, must be changed from the run to the pgm position. After this is done, the gas module (area) board being reprogrammed will be brighter than the rest of the gas module (area) boards (when viewed from the front) and the yellow PGM LED indicator will be flashing to indicate that the alarm is in the program mode and the board which is illuminated more brightly and has the flashing PGM LED is ready to be reprogrammed. The remote signal (master) board being reprogrammed will have the top (first) signal point flashing and the programming display LED s (at the bottom of the board) will illuminate displaying either an O (open circuit) or a C (closed circuit) or a d (disabled). The programming buttons, located on the front of the alarm, upper left corner (see photo on page 22) may now to be used to make the needed program changes. When you have successfully accessed the program mode, it is important to note that some of the buttons revert to their sub-functions: When programming a gas (area) module: The UP key is used to raise the pressure set point and / or to toggle upward thru the list of sub- options. The DOWN key is used to lower the pressure set point and / or to toggle downward thru the list of suboptions. The RIGHT key is used to toggle (scroll) thru the list of major options. The LEFT key is used to SAVE the new programming options after they are selected. When programming a remote signal (master) module: The UP key is used to toggle between the choices of the green LED or the red LED or both the green & reds illuminated (disabled). The DOWN key is used to toggle between the choices of the green LED or the red LED or both the green & reds illuminated (disabled). The RIGHT key is used to toggle (scroll) down to the next remote signal point. The LEFT key is used to SAVE the new programming options after they are selected. Note: In order to perform any of the following programming features you must first set the alarm in the program mode. Programming the High & Low Gas Pressure set points Immediately upon entering a gas module (area) board in the program mode, the high line pressure set point major option is displayed. If the gas module being programmed is a typical 50 psig delivery pressure gas, the board has been pre-programmed at the factory with the high line pressure set point at 60 psig, so the display should show the number 60. If you wish to raise or lower this setting, simply use the up or down keys to adjust the pressure setting. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
24 Programming the Alarm After the setting has been changed to the new desired setting, press the LEFT key (SAVE) to save the new setting. Note: if the SAVE LEFT key is not pressed after making the change to the programming and before pressing any other keys, the new setting will not be saved and the alarm will revert to the previously saved setting(s). When the SAVE key is depressed, three horizontal dashes will appear in the display. Press the key to move on to the low line pressure and repeat the above procedure. Note: The alarm is designed with a safety feature so that the high and low set points must be at least 0.5 (psig / in Hg), 0.05 (bar) or 5 (kpa) increments apart. The high set point will not be able to be set below the low set point and visa versa. Programming the Remote Signal (Master) Alarm Points While in the program mode, the top signal point LED will be blinking. At the bottom of the same remote signal board, the Programming Display LED set will display the contact state for the blinking signal point. O = open, C = closed and d = disabled. The contact point that is flashing is capable of being reprogrammed. (Note: in compliance with NFPA 99, all contacts are programmed as closed contact equals a normal condition from the factory). If it is necessary to re-program a signal point; press the key to view the next Remote Signal Alarm Point, when the desired Remote Signal (Master) point is flashing, use the or keys to alter the point to the desired status, after the desired change is achieved, press the to save the change. Note: Any contact point that has been disabled will have both the green (normal) and red (alarm) LED illuminated only when in the programming mode, to make it easy to identify them. In the normal mode of operation, both LED s of a disabled signal point will not illuminate nor will this signal point trigger an alarm. Note: When an alarm condition occurs the audible buzzer sounds simultaneously with the corresponding red LED illuminating and the green corresponding LED being extinguished. When the silence button is depressed, the audible buzzer is silenced and remains silenced until another alarm condition occurs. Master alarm signals do not repeat. Programming the Gas Alarm Repeater Delay After placing a gas board in the program mode, press until dly is displayed on the digital display of the gas module then let go of the key. A number will be displayed on the digital display. This number is the setting (in minutes) of the repeater delay. Using the or keys, adjust the repeater delay to the desired length of time (0 240 minutes). (Note: the repeater delay is preprogrammed from the factory at 10 minutes per NFPA 99). To save the change and return the alarm to the normal alarm mode, press the button, then change the dip switch back to the run setting. Note: this procedure must be repeated for all gas boards on the alarm panel. Note: master alarm signals do not repeat Note: If a value of 0 (zero) is programmed and saved for any board, the repeater is disabled. If left programmed this way after 72 hours, the board(s) will automatically revert back to the preprogrammed factory setting of 10 minutes. Programming the Units of Measure Displays While in the program mode, press the button until -U- is displayed on the digital display of the gas module then let go of the key. The letters PSI or baѓ or PA will be displayed on the digital display. This is the unit setting that the gas board is set to display. If you wish to alter the unit display, use the or keys to select the desired unit display, then press the SAVE key. Note: this procedure must be repeated for all gas boards on the alarm panel. Note: Vacuum & EVAC / WAGD Gas Modules will automatically display in in/hg when PSI is selected. Note: The kpa and x10 LED s will both illuminate on all high delivery pressure Gas Modules (i.e. Nitrogen and Instrument Air) when kpa is selected. Because the Gas Pressure LED Display is only able to display three digits and high delivery pressures viewed in kpa are four digits, the Gas Pressure LED must be read as a four digit number by multiplying the displayed number by ten. I.E. the Gas Pressure LED Display is displaying 125 in kpa. The pressure should be read as 1,250 kpa (125 x 10). e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
25 Adjusting the Digital Line Pressure The digital line pressure may be adjusted slightly (per the chart below) by following the simple procedure below. This can be done by one person at the alarm panel no need to open/adjust the transducers! 1. Put the gas module you want to adjust into the PROGRAM MODE. 2. Using the TOGGLE (right arrow) button go to the CAL mode. 3. Use the UP ARROW button to increase the pressure reading and the DOWN ARROW to decrease the pressure reading. The adjusted reading will be displayed as the changes are made. 4. Press the SAVE button (left arrow) to save the setting. 5. You can return to the original calibration setting by pressing CLEAR then press the SAVE button (left arrow) while at CAL in the PROGRAM MODE. This should be done if a transducer is ever replaced, as the reading offset will be applied to the new transducer readings. Range of adjustment: VAC or EVAC /WAGD ± 0.5 In hg 100 psig transducers ± 2.5 psig 250 psig transducers ± 6.0 psig Programming the Board Identification # Note: This feature is only used when the alarm is used in conjunction with a Tri-Tech Medical T- Net system. Note: Each gas and master (remote signal) circuit board must have a unique Identification Number no two can share the same number. After placing a gas board in the program mode, press until Cld is displayed on the digital display of the gas module then let go of the key. A number will be displayed on the digital display. This number is the board identification # assigned to that circuit board. Using the or keys, select the desired board identification #. Use the SAVE button when you are finished. Note: Each gas and master (remote signal) circuit board must have a unique Identification Number no two can share the same number. Programming the Alarm Note: Valid identification numbers are The alarm is pre-programmed at the factory with 0 (zero) as the zone identification number. Adding/Removing Modules or Changing the Gas Service of a Gas Board To remove either a gas board or a remote signal master board from an alarm you simply need to turn off the power to the alarm panel (using the switch on the outside of the power supply in the back box), unplug the ribbon cable from the board being removed and then turn the power back on. The alarm will automatically reset itself. To add a remote signal master board to an alarm you follow the same instructions above. Note: The following feature is only used if; an additional gas service is being added to an area alarm, a future gas module is being set up for a new gas service or and existing gas module board is being changed to a different gas service. The gas boards are pre-programmed for a specific gas service from the factory. After placing a gas board in the program mode, it is possible to change the gas service of the board. The following list cross references the number that is actually displayed on the gas board numeric display with the full names of the gases: Gas # displayed Gas service Transducer type 12 Nitrogen Oxygen Nitrous oxide CO2 or CO2-O2 mix Medical Vacuum Wagd / AGSS Medical air Helium or Heliox 100 H16 Instrument air 250 H24 Hyperbaric oxygen 100 H08 Medium pressure 100 carbon dioxide SP Gas mixture 100 HSP High Pressure gas mix 250 3SP Tri-Gas 100 e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
26 T-Net Interface Circuit Board Installation Tri-Tech Medical DU/DC series alarms may be ordered without T-Net Interface Circuit boards. The T-Net Interface Circuit boards may be installed later. The toggle switch on the front of the power supply should be placed in the OFF position. You will be installing one of three types of interface circuit boards, bracket and cable connector; RS485, Ethernet or Wireless. The Ethernet Interface board is shown here left and the Wireless board is shown here right. Note: Units incorporating the wireless interface circuit board contains FCC ID OUR-9XTEND. The enclosed device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Any of the three types installs into the bottom right corner of the alarm back box. The wireless antenna drops thru a hole in the bottom of the back box. The bracket mounts to the existing flange nut. The cable must be installed into the socket on the Button Board properly per the instructions on the cable. All of the gas boards and remote signal (master boards) will need to be re-programmed with a unique identification number and set up in the T-Net software per the T-Net installation instructions provided with the T-Net software. The power may now be restored to the alarm. The alarm is fully functional even if the T-Net software is not yet installed or is out of service. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
27 Building Management Interface (MCP)Board Wiring Tri-Tech Medical DU/DC series alarms may be ordered with standard remote signal circuit board(s) or with building management interface circuit board(s). The building management interface circuit board(s) may be installed later, replacing the standard remote signal circuit board(s). It is only necessary to install building management interface board(s) in one of the master alarm panels. The toggle switch on the front of the power supply should be placed in the OFF position. Output connections to building management system Refer to Wiring Remote Devices to Remote Signal (Master) Board page 13 the building management interface circuit boards (MCP boards) are wired the same way as the standard remote signal circuit boards. The additional two sets of connection terminal are the connection points for the wires outputting the signal information to the building management system. Input connections from remote signal devices The connector terminals may be un-plugged from the circuit board to simplify installation of the remote signal wires. There is no need to remove the wires, simply unplug the connectors from the standard remote signal board and plug them back into the new building management interface circuit board. Be certain to match the label on the socket with the label on the plug. The additional connector terminals are labeled 1 OUT thru 16 OUT and are located on the left edge of the new building management interface circuit board. These correspond with the pairs labeled 1 IN thru 16 IN on the right edge of the circuit board. The NC labeled terminal of each pair is where the signal wire should be landed. The C labeled terminal of each pair is where the common wire should be landed. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
28 Appendix A Appendix A Glossary of Terms AC DC Alternating Current An electric current that reverses direction or polarity at regular intervals. Direct Current An electric current that flows in one direction. The current can be steady or pulse. IN Hg Inches of Mercury A measurement of the force in a gas vacuum system. 1 IN Hg = 3.38 kpa. KPa LED Kilopascals A measurement of the force in a compressed gas system. 1 kpa =.14 PSI Light Emitting Diode A semiconductor diode that converts applied voltage to light. NFPA National Fire Protection Association The National Fire Protection Association is an association engaged in standards development. NO Normally Open An electrical circuit in which the switch is normally open. No current flows through the circuit in normal operation. Only when the switch is closed is the flow of current started. NC PSI V Normally Closed An electrical circuit in which the switch is normally closed. Current flows through the circuit in normal operation. Only when the switch is opened is the flow of current stopped. Pounds per Square Inch A measurement of the force in a compressed gas system. 1 PSI = 6.9 kpa Transducer A device that converts pressure into an electrical signal. Voltage Voltage is electrical pressure or force. One volt is equal to the difference of electrical potential between two points on a conducting wire carrying a constant current of one ampere when the power dissipated between the points is one watt. Transient Signal An intermittent and brief signal that quickly corrects and returns the alarm to a normal operating mode before monitoring personnel can silence the alarm. e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
29 Appendix B Appendix B Medical Gas Alarm Specifications Operating Ambient Temperature range: +10C(50F) to +50C(122F) Storage Temperature: -20C(-4F) to +85C(185F) AC Input: volts AC Hz DC output (to remote signal devices): 5 VDC Input Fuse: 5 amp input AC line fuse protects the input wiring to power supply Power Consumption: 45W 120 V 50 W 240 V Pressure Measurement Accuracy: 0-30 inhg transducer +/-1% Vacuum, Gas Evacuation Dimensions PSIG transducer +/-1% Oxygen, Nitrous Oxide, Medical Air, Carbon Dioxide 0-250PSIG transducer +/-1% Nitrogen Rough-in Box - All dimensions are in inches and cover the basic box only (mounting flange excluded) Two vertical slot panel 8.125W x H x 4.000D Three vertical slot panel W x H x 4.000D Five vertical slot panel W x H x 4.000D Front Panel Two vertical slot panel W x H x 1.250D Three vertical slot panel W x H x 1.250D Five vertical slot panel W x H x 1.250D Transducers: Housing dimensions: 1.990W x 1.990H x Length including inlet fittings e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
30 Appendix C Remote Signals Tri-Tech Signal Wire Color Code Log Appendix C Signal Position # Remote Signal Label Signal Wire Color Common Wire Color Remote Signals Signal Position # Remote Signal Label Signal Wire Color Common Wire Color e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
31 Appendix D Wiring Diagram e5755ra 9/17/13 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No
32 Appendix E Source Equipment Wiring Diagram e5755ra 9/17/13 Tri-Tech, Avon Commerce Parkway, Avon, Ohio No
33 Appendix F Remote Transducer Wiring Diagram e5755ra 9/17/13 Tri-Tech, Avon Commerce Parkway, Avon, Ohio No
34 Terms and Conditions and Warranty Buyer s purchase order is subject to the following conditions of sale: Prices and transportation Seller s published prices, terms of payment, including discounts, and transportation terms in effect at date of shipment of goods, shall apply. Prices are subject to change without notice. All pricing is in U.S. dollars. Taxes Liability for all taxes, licenses, or other fees imposed upon the production, sale, shipment, or use of the Seller s products or services covered by this catalog and resulting in quotations shall be assumed and paid for by buyer. If Buyer is a health care facility and a sales tax should be paid, it is Buyer s responsibility to file a Use Tax Return in your state. Shipment Delivery will be made F.O.B. Seller s shipping point or Vendor s plant, all risk of loss shall pass to Buyer upon delivery to carrier, and Buyer shall be responsible for obtaining insurance if desired. Seller will ship by carrier selected by Seller unless specified by Buyer in its order. Payment Unless otherwise specified, invoices shall be due and payable with thirty (30) days of the invoice date. Payments shall be in U.S. dollars. A 1.5 % per month finance charge will be added to any invoice not paid within terms. A $20.00 bank charge will be added to any returned checks. Cancellations and Returns Order may not be cancelled without the prior written consent of the Seller. Products may not be returned without the prior written consent of the Seller. Transportation charges for returned products will be paid by the Buyer. Cancellation and restocking charges will be assessed to the Buyer where applicable. Assignment No rights or obligations arising under any contract between the Seller and Buyer may be assigned or transferred by Buyer without the prior written consent of the Seller. Patent or Trademark Infringement If the goods sold hereunder are to be prepared or manufactured, in whole or in part, according to Buyer s specifications, Buyer shall indemnify and hold Seller harmless from an against any and all claims or liabilities with respect to or arising out of actual or alleged patent or trademark infringement on account of such preparation or manufacture and shall, at the option of Seller assume the defense thereof. Warranty and Remedy The Seller warrants the products described herein to be free from defects in material and workmanship at the date of shipment. Seller makes no warranty with respect to products manufactured by others and furnished hereunder; provided however, Seller shall extend to Buyer any warranties which it receives from such vendors. NO OTHER WARRANTY, WHETHER EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF SUCH PRODUCTS. In the event of breach of any warranty hereunder, Seller s sole and exclusive liability shall be at its option either to repair or to replace F.O.B. point of shipment, any defective product, or to accept return, transportation prepaid, of such product and refund the purchase price; in either case provided that written notice of such defect is given to Seller within twelve (12) months from date of shipment to Buyer, that the product is found by Seller to have been defective at the time of such shipment, that the product has been installed and/or operated in accordance with Seller s instructions, that no repairs, alterations or replacements have been made by others without Seller s written approval and that Buyer notifies Seller in writing within fifteen (15) days after the defect becomes apparent and promptly furnishes full particulars in connection therewith; and provided further that in no event shall the aggregate liability of Seller in connection with breach of any warranty or warranties exceed the purchase price paid for the product purchased hereunder. Seller may, at its option, require the return of any product, transportation and duties prepaid, to establish any claim of defect made by Buyer. Unless otherwise agreed in writing (a) Seller will not accept and shall have no responsibility for products returned without its prior written consent, and (b) Seller will not assume any expense or liability for repairs to products made outside of its plant by third parties. In the event Seller elects to replace a defective product; costs of installation, labor, service, and all other costs to replace the product shall be the responsibility of Buyer. Seller shall not, except as set forth above, be otherwise liable to Buyer or to any person who shall purchase from Buyer, or use, any products supplied hereunder for damages of any kind, including, but not limited to, indirect, special or consequential damages or loss of production of loss of profits resulting from any cause whatsoever, including, but not limited to, any delay, act, error or omission of Seller. Minimum billing $ e5755ra 9/17/13 Tri-Tech, Avon Commerce Parkway, Avon, Ohio No \
DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0
Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm
IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION
Form No. 74-00-4001 S168-527-001 Rev. B IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION Allied Healthcare Products, Inc. s IMPACT alarms are designed
DC Series Digital Conversion Alarm Operator s Manual
DC Series Digital Conversion Alarm Operator s Manual Ver. 2012 - Rev. 1004 Class 1 Inc. design manufacture installation service world class innovation Call us for your next project. Area Alarm Conversion
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Operating & Maintenance Manual. Alert-2 Microprocessor Based Digital Alarm System v5.9
Operating & Maintenance Manual Alert2 Microprocessor Based Digital Alarm System v5.9 w w w. a m i c o. c o m Contents User Responsibility 5 Introduction 5 6 Features Description of the Alarm Shipment Details
MICROPROCESSOR BASED DIGITAL ALARM SYSTEM
MICROPROCESSOR BASED DIGITAL ALARM SYSTEM ALERT- 2 Installation and Maintenance Manual v4.0 Table of Contents USER RESPONSIBILITY... 4 INTRODUCTION... 5 FEATURES... 6 DESCRIPTION OF THE ALARM... 7 SHIPMENT
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Alert-3 LCD Alarm v2.1
Operating & Maintenance Manual Alert-3 LCD Alarm v2.1 1ST FLOOR ROOM 12 2ND FLOOR ROOM 25 3RD FLOOR ROOM 37 MAINTEN EXT 302 4TH FLOOR ROOM 47 5TH FLOOR ROOM 58 w w w. a m i c o. c o m Contents User Responsibility
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
PK5500 v1.1 Installation Instructions
PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on
T a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.
INTRODUCTION The information provided herein covers the range of products known as the 'Sensor 901' series. The range of equipment is designed to meet the requirements of BS 5839 parts 1 & 4 1988. The
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
OHIO MEDICAL CORPORATION. Medical Gas Alarms. Installation and Maintenance Manual. Area Alarm. Master Alarm. Combo Alarm. P/N 255098 (Rev.
OHIO MEDICAL CORPORATION Medical Gas Alarms Installation and Maintenance Manual Area Alarm Master Alarm Combo Alarm P/N 255098 (Rev.8) 07/08 Page 2 NOTES Page 3 SQUIRE-COGSWELL COMPANY WAS FORMED IN 1916
LST-3800. In-Dash Digital Sonar Gauge. Installation & Operation Instructions
Pub. 988-0064-351 LST-3800 In-Dash Digital Sonar Gauge Installation & Operation Instructions The LST-3800 is a depth and temperature gauge that comes with a 200 khz transducer, features deep and shallow
Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases
Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
Repair Parts/Beacon Medaes/Area Line Pressure Alarm
Repair Parts/Beacon Medaes/Area Line Pressure Alarm Description Part Number Module Gauge Assembly Part Number 1. Front Panel #0221-6804-100 2. PC Board, Control/Display #0631-5010-700 3. Screw, 6-32 x
Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
Applied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system Remote Control Motorcycle Alarm System Installation & Operation Instructions Sistema de Alarma de
WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA 02745 USA
Thank you for purchasing the Maximum wind speed alarm. The Maximum wind speed alarm is a dual set point wind speed indicator with a two digit LED display. It contains a yellow light to display one set
MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system 1017 2-way pager system
MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system 1017 2-way pager system Remote Control Motorcycle Alarm System Installation & Operation Instructions Sistema de Alarma de
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Fire Pump Controllers Remote Alarm Panels
Fire Pump Controllers Remote Alarm Panels Remote Alarm Panels 1.8 Remote Alarm Panels FDAP-M Electric... DFDAP-M Diesel... Product Specifications... 2 6 9 Features 1-1 DFDAP-M / FDAP-M Remote Alarm Panel
CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual
SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL
CONTENTS 4. HOW TO UNSET THE PANEL...7
Pi-8 USER MANUAL CONTENTS 1. THE KEYPAD AND ITS OPERATION...3 1.1 DESCRIPTION OF THE KEYPAD LEDS... 3 1.1.1 READY LED (RED)...3 1.1.2 TAMPER LED (RED)...3 1.1.3 POWER LED (GREEN)...3 1.1.4 CIRCUIT LEDs
EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual
EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: [email protected]
PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter
MODEL PRO-9744 INSTALLATION MANUAL Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter This System Allows The Transmitter Buttons To Be
site monitoring Kit Site Monitoring Kit User Manual we prove it.
site monitoring Kit 1 User Manual Site Monitoring Kit User Manual we prove it. 2 site monitoring Kit Content 1. Introduction 3 2. Content of the Site Monitoring Kit 4 3. Preparation 6 1. Positioning of
Contractors Guide Central Inverter System Installation
Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.
Remote Alarm Monitoring System
Remote Alarm Monitoring System Operation and Service Manual Model RA1 RA4 A A Version HELMER SCIENTIFIC 14400 Bergen Boulevard Noblesville, IN 46060 USA PH +1.317.773.9073 FAX +1.317.773.9082 USA and Canada
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
Single Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
Installation Instructions
Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX INSTALLATION INSTRUCTIONS Step 1. Determine the position for the Hands-free phone in the elevator phone
HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate
HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate 1 Swing Plate Assembly-RM1-0043 1 Swing Plate Kit-5851-2766 (RM1-0043 plus RM1-1091 gear) CAUTION: Fuser may be hot. Turn off printer, unplug it and allow
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
i ChatterBox! Motorcycle Security
i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before
BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS
BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS WG2 Dimensions: LxHXW: 26 x 14.5 x 29.5 cm INTERNAL Alarm Terminals EXTERNAL Alarm Terminals WG2 Control Unit WaterGuard
A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS
A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS 1. Check your gauges before you take them out of the packaging to make sure they are at 0 (zero) psi for both boost and fuel pressure.
Before installation it is important to know what parts you have and what the capabilities of these parts are.
INSTALLATION GUIDE Before installation it is important to know what parts you have and what the capabilities of these parts are. The Recon XZT is the smallest and most powerful gauge of its kind. With
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet The NX-591NE-GSM is a microprocessor-controlled GSM interface module used to connect the NetworX series of control panels to GSM cellular networks
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
Installation and Operation Guide PD4600 Series Converter Replacement
Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your
Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
Fire Fighter Phone System Installation Instructions
Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).
Operating and Maintenance Instructions MEDIPOINT 125 MEDICAL GAS CENTRAL ALARM
Operating and Maintenance Instructions MEDIPOINT 125 MEDICAL GAS CENTRAL ALARM CONTENTS SECTION 0. SAFETY, STORAGE AND HANDLING DATA 0.1 Indentification of symbols 0.2 Environmental conditions 0.3 Environmental
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
TSn SERIES Surge Protective Device
Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 [email protected] Fax 804.355.8900 Page: 2 of 8 Quick
AUTODIALLER / QUICKDIALLER - SA132
AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING
CRYPTOPAY QUICK START GUIDE
Coordinator installation - install the coordinator at the car wash, preferably in the pump room, near an electrical outlet and the internet connection. Power Cord plug in the supplied power cord to coordinator
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Wash Select II to WashPay Integration Field Retrofit Installation Guide
Wash Select II to WashPay Integration Field Retrofit Installation Guide Wash Select II Software Version 6.00 and above POS4000 Software Version 8.25 Unitec www.startwithunitec.com WASH SELECT II TO WASHPAY
SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service
RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
AMICO Information. Management System (AIMS)
AMICO Information Management System (AIMS) ALERT- 2 Installation and Maintenance Manual v 2.5 Table of Contents INTRODUCTION...3 Theory of Operation... 3 Network Diagram... 4 INSTALLATION... 5 Medical
STC 3S012-020-A Series Solenoid Valves
STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,
UM-X Field display for continous level sensors
Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90
SmartLogger1000. Quick Installation Guide. Issue 05. Date 2013-12-15 HUAWEI TECHNOLOGIES CO., LTD.
Issue 05 Date 2013-12-15 HUAWEI TECHNOLOGIES CO., LTD. 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of
POWER WAVE 455M/STT & (CE)
Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-450 P-450 PARTS LIST FOR POWER WAVE 455M/STT & (CE) P-450-A P-450-A ILLUSTRATION
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
8900 EMR (WITH DETECTOR)
00 EMR (WITH ) GENERAL DESCRIPTION Each 00 EMR series unit contains a door closer, hold open electromagnet and smoke detector. The unit can be used as a single installation or as a series of singles powered
LED Security Spotlight User Manual
MOT ION-TR ACKING LED Security Spotlight User Manual www.jascoproducts.com 1-800-654-8483 2 TABLE OF CONTENTS Parts List 3 Questions? Missing Parts? 4 Installation (Wall mount) 6-9 Installation (Eave mount)
Porter Instrument Division
AA173200i Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA Tel: 215-723-4000 Ref. 10545100 Rev. F CE Notice The symbol on this product indicates compliance
NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL
NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
GSM-EXT Cable Assembly Installation Guide
GSM-EXT Cable Assembly Installation Guide For Documentation and Online Support: http://www.security.honeywell.com/hsc/resources/mywebtech General Information The GSM-EXT cable assembly is used to connect
Chapter 9 N.C. C. N.O. Single-Pole Double-Throw
rather than providing multiple choices. The sensor modules used may only be suitable for use with the matching controller so it is wise to read the specifications to make sure the unit suits your application.
How To Wire Wireline Cable To A Cell Phone (New Zealand)
Installation Guide EnerNOC Site Server - S2 Installation Guide - AUS, NZ v 1.7 EnerNOC New Zealand Limited 2 Collina Terrace PO Box 12-202 Thorndon Wellington NZ 6144 +64 4 909 7546 1 Table of Contents
Product and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 FUSION CULTURE TABLE OF CONTENTS There s no point doing something if no one notices. We ve always believed the way to make things happen is by getting
Wireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
Automatic Phone-Out Home Monitoring Systems
Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
