Fire and Smoke Damper Actuator Field Replacement Guide

Similar documents
Use the UL555S tested area results given in damper OEM sections below.

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

Fire and Smoke Dampers: Best Practice Design Tips. An AMCA International White Paper. July 2015

Y7230A CO 2 Alarm System

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

DUCT SMOKE DETECTOR D4120

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

T7079A,B Solid State Remote Temperature Controllers

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Fire-Rated Doors and Hardware. A Guide to Field Inspection

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES. Level III Content Outline

HERNANDO COUNTY FIRE ALARM GUIDELINES

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

I. Basic Smoke Control Strategy and Tactics

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

Series 71, 72, and 76 Modutrol IV Motors

NATIONAL FIRE ALARM AND SIGNALING CODE

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

D287/D288/D292/D293A/D293E

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM

Digi-Motor Installation Guide

AMD-33 Air Measuring Station with VCD-33 Control Damper

Fire Pump Controllers Remote Alarm Panels

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

NFPA Edition Fire dampers shall be permitted to be installed in exhaust systems in the following situations:

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

Understanding Emergency Power Off (EPO)

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

FIRE SAFETY INSPECTION REPORT

INSPECTION AND TESTING OF FIRE ALARM SYSTEMS

Fire Alarm Systems Certification

BERMAD Fire Protection

FIRE DAMPER APPLICATION GUIDE

E-PDD Duct Smoke Detector Installation Sheet

ViZion Installation Guide

ACS-30-EU-EMDR-10-MOD

conventional system operation

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Module 5. Fire and Emergency Alarm System Part I- Basics

Fire Alarm Systems Permit Packet. City of Greer Fire Department

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

PLAN REVIEW GUIDE FOR FIRE ALARM

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

National Archives and Records Administration (NARA) Facility Standards for Federal Records Storage Facilities

General Fire Code Requirements Within Commercial Tenant Spaces

BERMAD Fire Protection

CalMod Design-Build Electrification Services

Water Leak Detection System

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Fundamentals of HVAC Control Systems

INSPECTION AND TESTING FORM

LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market

WEBs-AX Enterprise Security

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

Fire Alarm System Plans Review Checklist Property location Date of Review

How To Install A Carbon Monoxide Detector

Module 4, Lesson 12 Fire Alarm Systems

Building Commissioning

Commercial Fire Inspections

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

ADDENDUM TO THE CONTRACT. for the. Bartlett Regional Hospital Server Room Cooling System Replacement. Contract No. E12-149

GST301. (Single Protection Zone) Operation Manual

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

Office of the State Fire Marshal. Fire Rated Doors

EMF/EMR. Holder/Release Devices with Integral Door Closers

AlarmSense 2-wire detection and alarm system. Product Guide

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Technical Data. Installation

Cross Reference Modutrol IV Motor Cross Reference For Honeywell and Competitive Motors

Errata NFPA 70. Proposed 2014 Edition

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

UV100A Ultraviolet Air Treatment System

City of Columbus Department of Building and Zoning Services

Tool Turrets and Tool Discs

HM-W536 Install Guide

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

SECTION DETECTION AND ALARM

Fire Alarm System Monitoring - CAN/ULC-S561-03

Environment of Care Fire Safety Management Plan 2014

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

Transcription:

Fire and Smoke Damper Actuator Field Replacement Guide REPLACEMENT GUIDE The following guidelines are crucial to keep fire and smoke damper assemblies operating properly, and to stay in adherence to standards and codes. FIRE CODE REFERENCES AND INFORMATION Honeywell Fire and Smoke Actuators are designed to meet both UL555 and UL555S safety requirements for combined fire and smoke applications, if applicable. The following maintenance guidelines are a summary of the National Fire Protection Association (NFPA) Codes as well as Air Movement and Control Association (AMCA) and Honeywell manuals. We recommend that you become familiar with NFPA 80, 90A, 92A & B, and 105 and AMCA publication 503. Be aware that other codes, such, International Building Code (IBC), regional, state and local codes, may also apply to your area. REPLACEMENT GUIDELINES APPLICATION Safety should never be left to chance. Honeywell fire and smoke actuators are designed to meet both UL-555 and UL555S 350 F safety requirements for fire and smoke applications, if applicable. Fast-acting actuators close dampers in 15 seconds, and the integral spring return ensures the consistent, proper level of torque. For the highest level of occupant safety, you can count on Honeywell. Fire and Smoke actuators and assemblies must function properly during a fire or life-safety emergency. Honeywell Fire and Smoke Actuators provide fast action when timeliness is key in preventing the spread of fire and smoke. Proper installation and periodic performance testing are required to ensure fire and smoke damper assemblies will fully function should an emergency occur. Actuator Specifications UL555 and UL555S require fire and smoke actuators to be tested to 20,000 close and reopen cycles and close within 75 seconds. UL555 also requires them to be rated to either 250 F or 350 F. If UL does not apply to your region, please omit. Honeywell fire and smoke actuators are rated to 30,000 cycles, operate within 15 seconds, and are rated to 350 F. Applications Combined Fire and smoke dampers are used to maintain fire barrier ratings when walls and floors are penetrated by ductwork. Smoke dampers are used to prevent the passage of smoke through the HVAC system or from one side of a fire-rated separation to the other. They may be dedicated to this function or also function as HVAC dampers. 38-00001-02

Damper Manufacturer s Guidelines When replacing actuators, it is important to follow the guidelines that are provided by the damper manufacturer for the damper assembly. When replacing a fire and smoke actuator the replacement should be either like-for-like with the original, factory-mounted actuator, or a technically superior product where the total assembly has passed UL testing with the damper manufacturer. Please refer to the damper manufacturer s guidelines for details. MAINTENANCE INFORMATION Fire and Smoke damper assemblies must undergo periodic performance testing to be properly maintained and to ensure they are functioning and will function in a fire or life-safety emergency. The NFPA codes require combined fire and smoke dampers be tested and inspected at the time the system is commissioned, after it has been balanced, and one year after installation. Then they need to be tested and inspected every 4 years, except in hospitals, where they need to be tested and inspected every 6 years. See "Option 1 and Option 2 in this section for detailed test instructions. AMCA suggests that smoke dampers be tested at least semi-annually. Smoke dampers should be operated, and the correct outputs should be observed, to verify operation. These tests need to also be conducted under standby power, if used. c. Use the signal from the damper s position indication device to confirm that the damper reaches its fully-closed position. d. Re-apply electrical power to re-open the damper. e. Use the signal from the damper s position indication device to confirm the damper reaches its fully-open position. Option 2: Dampers without position indication: a. Visually confirm that the damper is fully-open position. b. Ensure that all obstructions, including hands, are out of the path of the damper blades. c. Remove electrical power or air pressure from the actuator to allow the actuator s spring return feature to close the damper. d. Visually confirm that the damper closes completely. e. Re-apply electrical power to re-open the damper. f. Visually confirm that the damper is in the fully open position. 3. If the damper is not operable, it must be repaired as soon as possible. If the actuator has failed, replace it with a UL approved actuator if required. See Table 1. See Figs. 2-3 for mounting and installation information and Figs. 4-9 for wiring. After these repairs, the damper should be tested again. 4. If there is a latch, verify that it is operable. 5. Perform any other damper manufacture recommended maintenance such as lubrication. 6. Following the test and any repairs, document the location of the damper, the date, the inspector, and deficiencies or repairs. Keep the record for the life of the damper, and have it available as you may need to show it to an inspector. Honeywell Fire and Smoke Actuators are found in combination fire and smoke damper assemblies that use a bi-metallic disc type thermostat to interrupt electrical power to the actuator at a specified temperature. Once the specified temperature is reached, power will be interrupted and the spring return of the actuator will close the damper. When these actuators are used in smoke damper applications, they are usually controlled by smoke detectors or fire alarms. Periodic inspection includes: 1. Verify that there is full unobstructed access to the damper 2. Test the damper with normal HVAC airflow and verify that it opens following either Option 1 or Option 2. There should be no interference due to rust, damaged frame or blades, or other moving parts. Option 1: Dampers with Position Indication Wired to indication Lights, or Control Panels: Switches can be wired to local or remote control panels or building automation systems (BAS) to indicate that the damper is in the fully-open position, fully-closed position, or neither. a. Use the signal from the damper s position indication device to confirm that the damper is in the fully-open position. b. Remove electrical power or air pressure from the actuator to allow the actuator s spring return feature to close the damper. Fig. 1. Typical Fire and Smoke Damper Assembly. Source: AMCA International: Guide for Commissioning and Periodic Performance Testing of Fire, Smoke, and other Life Safety Related Dampers, 2012. 38-00001 02 2

PRODUCT INFORMATION Torque 30 lb-in (3.4 Nm) 80 lb-in (9 Nm) 175 lb-in (20 Nm) Model Number MS4104F1010 Voltage SPST Aux Switch Legacy Honeywell 120 Vac 0 ML4115A1009 ML4115A1017 ML4115B1008 ML4115B1016 ML4115H1002 ML4115J1009 ML4202F1000 ML4302F1008 Belimo Cross FSLF120 US Siemens Cross None MS4104F1210 120 Vac 2 Internal None FSLF120-S US None MS4604F1010 230 Vac 0 ML4115C1007 ML4115C1015 ML4115D1006 ML4115D1014 ML4702F1009 ML4802F1007 FSLF230 US None MS4604F1210 230 Vac 2 Internal None FSLF230-S US None MS8104F1010 24 Vac 0 ML8115A1005 ML8115A1013 ML8115B1004 ML8115B1012 ML8115H1008 ML8115J1005 ML8202F1006 ML8302F1004 FSLF24 US None MS8104F210 24 Vac 2 Internal None FSLF24-S US None MS4109F1010 120 Vac 0 MS4209F1007 FSNF120 US GND221.1U MS4309F1005 MS4109F1210 120 Vac 2 Internal None FSNF120-S US GND226.1U MS4609F1010 230 Vac 0 MS4709F1014 FSNF230 US GND321.1U MS4809F1012 MS4609F1210 230 Vac 2 Internal None FSNF230-S US GND326.1U MS8109F1010 24 Vac 0 MS8209F1003 FSNF24 US GND121.1U MS8309F1001 MS8109F1210 24 Vac 2 Internal None FSNF24-S US GND126.1U MS4120F1006 120 Vac 0 None FSAF120 US GGD221.1U MS4120F1204 120 Vac 2 Internal None FSAF120-S US None MS4620F1005 230 Vac 0 None FSAF230 US GGD321.1U MS4620F1203 230 Vac 2 Internal None FSAF230-S US None MS8120F1002 24 Vac 0 None FSAF24 US GGD121.1U MS8120F1200 24 Vac 2 Internal None FSAF24-S US None Table 1. Fire and Smoke Cross Reference. 3 38-00001 02

INSTALLATION AND WIRING 2 (51) 1 (25) 3-15/16 (100) 2 (50) 90 0 (17) 11/16 6-3/8 (161) 1-9/16 (40) 10-11/16 (271) 8-15/16 (227) 8-5/8 (220) 4 (102) 2 (51) 3-1/4 (83) 1/16 (2) 9/16 (14) 5-1/8 (130) M34622 Fig. 2. Dimensions for MS4104, MS4109, MS4604, MS4609, MS8104, and MS8109 Series actuators. See the following literature for further details and mounting instructions: Product Data and Installation Instructions: 63-2740 Specification data: 38-00006 M20051A 1/4 (6) 2-15/16 (75) Fig. 3. Dimensions for MSXX20F actuators. See the following literature for further details and mounting instructions: Product Data and Installation Instructions: 63-2584 Specification Data: 63-2592 38-00001 02 4

Wiring For 30 lb-in and 80 lb-in (3.4 Nm, 9 Nm) models: For 175 lb-in (20 Nm) models: MS8120F 24 VAC BLACK RED 24 VAC BLACK RED M20053B Fig. 4. Typical 24 Vac wiring. M34624 Fig. 7. Typical 24 Vac wiring MS4120F 120 VAC WHITE BLACK 120 VAC WHITE BLACK M20056B Fig. 5. Typical 120 Vac wiring. M34625 Fig. 8. Typical 120 Vac wiring. MS4620F 230 VAC BROWN 230 VAC BROWN M34626 M20057B Fig. 6. Typical 230 Vac wiring. Fig. 9. Typical 230 Vac wiring. 5 38-00001 02

38-00001 02 6

7 38-00001 02

By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. Home and Building Technologies In the U.S.: Honeywell 1985 Douglas Drive North Golden Valley, MN 55422-3992 customer.honeywell.com U.S. Registered Trademark 2016 Honeywell International Inc. 38-00001 02 M.S. Rev. 11-16 Printed in United States