Access Floors. General Contractor s Guide for Constructing & Sealing Access Floor Air Plenums

Similar documents
Tate s Wire & Cable Solution

Data Center Optimization Services. Maximize Your Data Center

Raised Floor Data Centers Prepared for the Future

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

6 Reasons to Specify Air-Sealing Grommets in the Design of a New Data Center

Excerpts from the Canadian National Building Code (NBC)

Challenges and Failures in Green Building Design Using Under-Floor Air Distribution. Ken Urbanek, PE, HBDP, LEED AP Director of Engineering

REQUEST FOR BOARD ACTION HENDERSON COUNTY BOARD OF COMMISSIONERS. ATTACHMENTS: 1. Construction Management Update

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

Design Development Quality Management Phase Checklist Project Phase Checklist Series

T170 Interior Design Technology MTCU Code Program Learning Outcomes

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

OPEN ITEMS LIST - CONSTRUCTION Project Name: East Central Middle School - Jackson County CLA#: 11003

CLM 2014 Construction & Environmental Conference August 1, 2014 Boston, MA. Expert Strategies for Managing Construction Defect Litigation

Exterior Elevated Elements Inspection Guidelines

State of Connecticut Department of Public Health RADON PROGRAM

SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE NOTICE TO PROPERTY OWNER

Gramercy Place Condo Association, Inc.

Hartsfield-Jackson Atlanta International Airport s

Exhibit C: Scope of Work and Schedule of Deliverables

Commercial Building Permit Application & Submittal Guidelines

RULES AND REGULATIONS CONTRACTOR WORK

TOWN of NEW BOSTON. Bid Package. Refurbishment and Upgrade of Basement of the New Boston Town Hall

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

REQUEST FOR QUALIFICATIONS FROM FOUNDATION REPAIR CONTRACTORS BROOMFIELD DEPOT FOUNDATION REHABILITATION PROJECT

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

2012 BIM Guidelines and Standards (Rev. 00) University at Albany

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

BUILDING/PLUMBING PERMIT APPLICATION REQUIREMENTS

Fire Barriers & Fire Stopping

Important Information for Owners of Buildings in Flood Zones

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage

Structure Survey Findings:

Schematic Design: Quality Management Phase Checklist Project Phase Checklist Series

City of Fort Smith Building Permit Process Frequently Asked Questions

Basement Finishing 101: The Essential Guide to Finishing Your Basement

TD AMERITRADE Park Omaha

PLAN SUBMITTAL INFORMATION

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

City of St. Charles Basement Finish or Remodel

ACOUSTIC ISOLATION DETAILS

SAN FRANCISCO UNIFIED SCHOOL DISTRICT 2011 PROPOSITION A BOND PROGRAM Paul Revere School Modernization and Interim Housing ADDENDUM NO.

D Sample Notices to Property Owners, Sample Affidavits, and Other Material

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Hamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year

Building Code Clarifications - 7. Fire Resistance

Building, Plumbing, Electrical and Residential Water and Sewer Inspection Requirements

Repair and Remodeling Estimating Methods. 4th Edition. RSMeans

TENANT DESIGN MANUAL UPDATED JULY 2015

Renovations for a New 18 Bed Gero-Psych Nursing Unit August 7, 2014 Lower Bucks Hospital Second Floor 501 Bath Road, Bristol, PA Addendum No.

CITY OF YORBA LINDA P.O. BOX CALIFORNIA

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

2009 Housing Provider Forum. Ontario Environmental & Safety Network Ltd.

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Chapter 2: Foundations

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Total Building Commissioning: Case Study of the U.S. District Courthouse in Salt Lake City, Utah, USA

HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA

HomeSpec REPORT SUMMARY

TRANSBAY JOINT POWERS AUTHORITY

City of Oviedo Commercial Shell Building Permit Application Guidelines

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

Building Construction and Development in Norristown: A User s Guide to the Land Development and Building Permit Process 1/25/11

Construction Technologies Career Field Pathways and Course Structure

Notice to Property Owners

Indiana Building Rehabilitation Standard

APPLICATION FOR HISTORIC MIRAMAR COMMERCIAL REHABILITATION PROGRAM (TARGET AREA)

Name of course: Residential Construction Site Management (RCSM) Level 1

PARK COUNTY BUILDING PERMIT GUIDE PO Box 517 Fairplay, CO Fax: Inspections:

Building Condition Assessment Report

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

BUILDING PERMIT SPECIFICATIONS

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV ~ (702)

Lee, Here are the questions from bidders received between August 17, 2015 and August 24, 2015 followed by our responses.

FIRESTOPPING & SMOKE SEALS

Uniform Construction Code (UCC) Manufactured Homes. Modular Homes. Building Permit Application Package

32315 ADOPTED BOARD OF TRUSTEES COMMUNITY COLLEGE DISTRICT NO. 508 JUNE 5, 2014

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

Autodesk Revit LEARNING PATH BUILDING DESIGN SUITE

MOISTURE MANAGEMENT DURING THE CONSTRUCTION PROCESS

KIEWIT CM/GC Enabling/Utilities

Olilo's AEC Design Services. SrinSoft Inc, Partners of

Project Implementation Guide for CT, PET/CT, X-Ray, and Nuclear Systems

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

Saint Cloud Business Center

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

MONTHLY PROJECT CONSTRUCTION PROGRESS REPORT #5

Bureau Veritas Contact Information

Key energy-efficient features of your new home

Building Code Inspections and Fees

Revised Work Scope Dated April 23 rd, 2015

Scope: Communications and Electronic Systems addressed in this section include:

BUILDING PERMIT APPLICATION APPLICABLE TO CITY LIMITS AND ETJ CHAPTER 18, General

National Academy of Forensic Engineers FE ANALYSIS OF LATENT WATER DAMAGE TO BUILDINGS

Measurement Standards for Structures

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

Transcription:

Access Floors General Contractor s Guide for Constructing & Sealing Access Floor Air Plenums 1

Education and accountability are key to constructing an access floor air plenum. Downloadable Specifications & Details Visit Tate s website to download sealing details and recommended specifications. The details are available in AutoCAD dwg and PDF file formats. Specifications can be found in the architectural details section of the website, www.tateinc.com. www.tateinc.com 2

GC s Guide for Constructing & Sealing Access Floor Air Plenums Plenum Integrity is one of the most important aspects of designing, constructing and maintaining an underfloor air delivery (UFAD) system. It is vital that the entire design and construction team does their part to ensure the underfloor plenum is sealed properly. As the general contractor you have the responsibility of ensuring all the subcontractors are informed of, and perform to the sealing requirements as described in the specifications and details provided by the architect. To ensure the UFAD system operates as intended after occupancy every contractor working in the plenum space needs to be aware of their responsibilities before they submit their bids and should be equipped with the information they need to successfully complete their work while maintaining plenum integrity. Tate is providing the following plenum construction and sealing guidelines for consideration. The recommendations contained within this guideline are based on lessons learned through working on a wide range of UFAD projects. To that end, Tate believes a holistic approach to design and construction should be used and recommends regular consultation be held with key individuals on the construction team throughout the entire design process. There are five primary recommendations. An overview of each recommendations is provided below followed by a more detailed explanation. Design: Pre-Bid Meeting: Pre-Construction: Mock-up: Quality Inspections: Review the project specifications and construction details with the architect prior to issuance of the construction documents. Coordinate a meeting to inform all sub-contractors of the specified plenum sealing requirements and mock-up requirements as developed by the architect. Coordinate a pre-construction meeting to reaffirm specified plenum sealing requirements for each division. Coordinate the construction and testing of a mock-up that includes all actual building conditions relative to the UFAD system. Ensure that all subcontractors remediate any issues identified by the commissioning agent during inspections prior to the access floor installation whenever possible and/ or as a result of the access floor air plenum testing. 3

General Contractor Guidelines As the GC you should ensure the following action items are fulfilled before, during and after the construction phase of the project to ensure the proper construction on the UFAD plenum. This guide is intended to be used along with its companion documents Architect s Guide for Detailing & Specifying Access Floor Air Plenums, which facilitates the creation of a properly functioning plenum by providing plenum sealing specifications and details, and the Commissioning Agent s Guide for Inspecting and Testing Access Floor Air Plenums, which serves as a checklist of the plenum locations that need to be inspected and outlines proper air leakage testing procedures. 1. Pre-Bid Meetings: During this meeting you should make sure the CSI specifications and plenum details containing all applicable plenum construction and sealing requirements are used to solicit bids. Each division should also be informed of the requirement to construct a pre-construction mock-up for air leakage testing. The specification sections which should be involved are: Access Flooring, Sheet Rock, HVAC, Electrical, Communications, Plumbing and Finishes/Tile Carpeting. Other specification sections may have been added by the architect for any contractor who will build part of the plenum or penetrate into it. 2. Pre-Construction Meetings: The pre-construction meeting is to reaffirm the importance of plenum sealing integrity and point out areas of contractor responsibility. It s a good idea to make sure all successful bidders especially those who didn t attend the pre-bid meeting have copies of the architect s plenum sealing drawings and specifications before plenum construction begins. At this time you should also reiterate to the contractors and indicate that the sealing portion of their work will be inspected and that they will be required to correct deficiencies. 3. Plenum Mockup and Testing: You will need to coordinate and schedule all successful bidders to take part in building an on-site access floor plenum mockup in accordance with the design specifications and construction details for inspection and air leakage testing. The mockup should be representative of all scenarios present in the final structure including, but not limited to: at least one sheetrock wall with sealed joints below the access floor, sealed access floor perimeters, a sealed plenum divider, floor covering (and cove base if required), air diffusers, power/voice distribution boxes, sealed penetrations for ductwork, conduit, cabling and a pipe passing through the wall(s). 4. Auditor: You should coordinate with the independent quality auditor or commissioning agent to inspect the plenum construction and sealing work to verify that it complies with the specifications and drawing details. Audits should be done frequently and throughout construction with at least one audit-taking place immediately before the access floor is installed. The auditor or commissioning agent should provide you with www.tateinc.com 4

a detailed report identifying any construction conditions that do not comply with the specifications and construction details. (see example report below) 5. Testing: The commissioning agent mentioned in step 4 should be required to perform air leakage tests on both the completed mock-up and the finished plenum after construction is completed. It s best to work in conjunction with the commissioning agent to test the mock-up and plenum for air leakage. Total air leakage from the plenum should meet the project requirements specified by the architect based on the total designed air volume to be delivered. 6. Remediation: You should ensure that all sub-contractors remediate any issues identified by the commissioning agent during the construction process inspections prior to the access floor installation, and any remediation identified after access floor installation and subsequent air leakage testing. Plenum Inspections & Reporting Form The following checklist of structures, plenum seams, penetrations and openings should be submitted by the commissioning agent after every inspection. Some sealing requirements may not be applicable to all projects. All inspections should be coordinated and conducted along with the general contractor. Base Building Core and Shell Perimeter seam along slab and exterior wall. Enclosed column seam at slab line. Drywall partition condition at slab line. Base of stair landing. Top of stair landing. Elevator shaft below access floor line. Bathroom on raised core. Expansion joint in concrete deck. 5

HVAC System Opening in slab for vertical ducts. Opening in plenum wall for ducts. Plumbing System Pipe penetrations through concrete deck. Pipe penetrations through plenum walls. Electrical System Conduit through plenum walls. Open ends of conduits in the plenum space. Voice/Data System (Communications) Cable penetrations through the plenum walls with cable sleeves. Caps on empty conduits or cable sleeves. Access Floor ZONE PARTITIONING Plenum dividers. Air highways. Penetrations through plenum dividers. www.tateinc.com 6

Access Floors (Continued) ABUTMENTS Perimeter seam without wall base. Through wall without wall base. Perimeter seam with wall base. Through wall with wall base. Perimeter seam at non-smooth walls and columns. Access floor seal at fascia/exposed edge. Perimeter seam at elevator shaft. Perimeter seam at top of stair landing. Perimeter seam at base of stair landing. Perimeter seam at fire barrier below door threshold. Perimeter seam at curb where floor covering is continuous. Perimeter seam at curb where floor covering is not continuous. PENETRATIONS Cable cutouts and grommets. Power/voice/data distribution boxes in access floor panels. Pipe penetrations through the access floor. Inside walls through the access floor. 7

Corporate Headquarters: 7510 Montevideo Road, Jessup, MD 20794 Tate Hotline: 1-800-231-7788 Tel: 410-799-4200 Fax: 410-799-4207 Production Facilities: 7510 Montevideo Road, Jessup, MD 20794 52 Springvale Road, Red Lion, PA 17356 Canadian Sales & Support Office: 880 Equestrian Court, Oakville, ON L6L 6L7 Canada Tate Hotline: 1-800-231-7788 Tel: 905-847-0138 Fax: 905-847-0141 Australian Sales & Support Office: 28 Biloela Street, Villawood NSW 2163 Tel: 02-9728-4111 Fax: 02-9728-3088 Asia Sales & Support Office: 19 Cecil Street #05-03, The Quadrant Singapore 049704 Tel: 65-6653-5358 Fax: 65-6468-6681 Central and South American Sales & Support: Tel: 443-995-1808 European Sales & Support: B16 Ballymount Corporate Park, Ballymount Avenue, Ballymount, Dublin 12, Ireland Tel: 353-879-820-873 Middle East Sales & Support: Tel: 514-512-2605 tateinc.com Tate is a registered trademark of Tate Access Floors, Inc. 2007 Tate Access Floors, Inc. Revised 2016