URSA GLASSWOOL URSA Timber Frame Roll & URSA Timber Frame Slab

Similar documents
Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Module 3.7. Thermal bridging

Rockwool Flexi Insulation Application Guide

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Multi-layer Insulation Blanket for Roofs

Rockwool Cladding Roll

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

The Kingspan Insulation Price List 1 st January 2013

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

The Pocket Guide To Insulation August 2013

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Energy Company Obligation (ECO): Technical Monitoring Questions

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

Rev Code of Practice. SIP Technology.

Timber Frame Walls Rethinking Construction

Composite Panel Firewall Systems

Including. Rubershield-Pro. Breather Membrane

Building Regulations for the Conservation of Fuel and Power

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

ProRox Slabs (formerly known as RW slabs)

PB301 July Lightweight Building Solutions. Bushfire Protection.

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

Low Energy Low Carbon Buildings

Innovation - High performance roof, wall and floor insulation board. delivering better performance

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Steel-framed Walls. Insulation

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

Post-insulation of cellar ceiling and cellar walls

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Low Energy Low Carbon Buildings

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

The Real Value of Space

How To Certify The Scottsdale Construction System

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

SIG SIG CAVITY WALL INSULATION

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

BLACK JACK ALL WEATHER ROOF COATING

European Organisation for Technical Approvals

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

Providing protection in construction

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Conventions for U-value calculations

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Residential Refurbishment. September ThermoShell Internal Wall Insulation System Design Guide

Mineral fibreglass insulation

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

INSTA-POLYPEARL CAVITY WALL INSULATION INSTA-POLYPEARL PLUS AND INSTA-POLYPEARL PLATINUM CAVITY WALL INSULATION

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Thermal Performance of Steel Beam Junctions using Different Connection Methods

Residential Inspection Guidelines

Manual lifting and handling

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Basements. I n s u l a t i o n. Low Energy Low Carbon Buildings

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

European Technical Approval ETA 13/0526

Internal wall insulation in existing housing

Airtight Intelligence

FLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation

DOMESTIC & GENERAL INSULATION LTD BLOWN-IN CAVITY WALL INSULATION THERMABEAD, THERMABEAD CARBON SAVER AND THERMABEAD DIAMOND CWI

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Agrément Certificate 06/4300 Product Sheet 1

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS

Chapter 2 Basis of design and materials

INSULATED PITCHED ROOFING

FIRE RATED GLAZING System Guide

Construction details. Technical specifications

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Regulatory Services. Asbestos in the Home. What is asbestos?

British Gypsum Guide to Timber Frame Construction. March 1998

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

Improving thermal insulation of concrete sandwich panel buildings

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

sound reduction systems for commercial, educational and industrial environments

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

The WANZ Guide to Window Installation

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

WATERPROOFING OF WET ROOMS

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Transcription:

URSA TF Roll (Tim & Met) - 065_Layout 1 22/07/2015 12:38 Page 1 URSA UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail : ursauk@ursa.com URSA GLASSWOOL URSA Timber Frame Roll & URSA Timber Frame Slab Insulation for Timber and Metal Frame Wall Systems BROUK-0023-07/15

URSA TF Roll (Tim & Met) - 065_Layout 1 22/07/2015 12:38 Page 3 The Company As a leading supplier of and insulating systems, URSA has succeeded in fully addressing user requirements for thermal and acoustic. Quality products for every application and excellent customer support are the cornerstones of the corporate culture. URSA is the number two manufacturer of glass wool and extruded polystyrene products in Europe. At 14 production sites, URSA has 2,000 employees generating sales revenues of over 500 million. URSA GLASSWOOL is manufactured in Spain, France and Belgium, at two sites URSA has in Germany, in Slovenia, Hungary and Poland as well as in two Russian plants. Our closely-woven network of sales offices stretches across Europe and Russia. Almost everywhere URSA is amongst the market leaders. In Russia and in a number of other Eastern European countries, we are number one in the glasswool segment. We have also enjoyed a strong position particularly on the growth markets of the new EU partner countries from the very beginning. URSA Timber Frame Roll & Timber Frame Slab URSA TF Roll is a lightweight, non-combustible, glass mineral wool product. It is suitable for use in both timber and metal framed walls. It has a thermal conductivity of 0.032 W/mK, 0.035 W/mK or 0.040 W/mK. URSA is a lightweight, semi-rigid glass mineral wool slab for use in timber framed walls. It has a thermal conductivity of 0.032 W/mK or 0.035 W/mK. Benefits Wider choice URSA TF Roll & will assist in meeting the appropriate Building Regulation standard with any form of timber or metal framed wall construction. Quality Outstanding product quality manufactured to ISO 9001 Quality Systems. User friendly Our new generation URSA GEO GLASSWOOL has a soft touch feel making it easier to handle and install whilst still maintaining its excellent mechanical properties. Global warming potential URSA TF Roll & do not use chemical blowing agents and so the Global Warming Potential (GWP) arising from them is zero. Insulation savings Used between studs in timber frame construction it is possible to meet the Building Regulation requirement with only 140mm of URSA TF Roll or. Acoustic URSA TF Roll & have excellent sound characteristics and enhance the acoustic comfort of the building. Environment Glass wool is manufactured from an abundant, sustainable resource and may utilise up to 80% glass waste. Reduced risk of condensation Walls fitted with URSA TF Roll & create more even warm conditions so reducing the risk of surface condensation. A vapour control layer is required when insulating between the studs. Handling URSA TF Roll & are lightweight yet tough, resilient and easy to install. They are easily cut using a sharp knife. Space saving Compaction of the rolls in their manufacture saves space in both storage and transport. Durability URSA TF Roll & are rot-proof, durable and maintenance free. They are non-hygroscopic and will not slump in normal use. All of our products carry the CE Mark to show compliance with the harmonised European Standard BS EN 13162. 2 URSA Timber Frame Roll & Timber Frame Slab 3 URSA Timber Frame Roll & Timber Frame Slab

URSA TF Roll (Tim & Met) - 065_Layout 1 22/07/2015 12:38 Page 5 Design Construction Principles There are three main forms of framed construction depending upon the position of the : Cold Frame all of the is fitted within the depth of the studs which results in the timber/steel bridging the. It is possible to add an insulated lining internally to both improve the thermal performance and mask the thermal bridge effect (see Figure 1). Warm Frame the is fitted externally to the framing, as a, to give a continuously insulated envelope. This form of construction has the advantages of preventing the thermal bridge problem and being inherently safe from harmful condensation risk (see Figure 2). Hybrid is fitted between the studs with an additional layer on the outside to reduce thermal bridging. Careful choice of the ratio of thermal resistances of each layer is required to avoid interstitial condensation (see Figure 3). Limiting Air Infiltration Ensure that the URSA TF Roll or is continuous and forms a tight joint at details such as corners. Where a timber floor meets the wall it is important to limit air infiltration by sealing around the perimeter of the floor. Expanding foam and/or mastic type sealants should be used under the sole plate to seal the floor edge. The polythene air and vapour control layer (AVCL) creates an additional air infiltration barrier. Wall Width The use of high efficiency has the benefit of achieving high standards of without a great increase in the overall wall thickness. Standard 140mm deep timber studs may be used whilst still achieving the current Building Regulation standard. Condensation An air and vapour control layer (AVCL) is generally required when insulating between the studs, this can either be a polythene sheet (minimum 500g) or a foil-backed plasterboard. When using the structural frame is maintained at the same temperature as the inside of the building and an air and vapour control layer (AVCL) may not be required. Surface condensation is generally not a problem with the correct choice of thickness, heating system and ventilation. Rainwater Penetration Projections and discontinuities within the cavity such as changes in wall thickness or beams will require the use of a cavity tray. When using in conjunction with a cold pitched roof ( at horizontal ceiling level) the top edge of the should be protected by the use of a cavity tray. Figure 1 Cold Frame Construction Figure 2 Warm Frame Construction Figure 3 Hybrid Construction Thermal Bridging Insulation installed between studs will introduce a series of repeating thermal bridges plus the effect of lintels, noggins and sole and top plates. This can significantly affect the calculated U-value as the framing may account for up to 20% of the wall area; the Building Regulations recommend a default of 15% framed area for calculation purposes. Figure 4 Wall/ Junction Insulation Below Slab DPM Figure 6 Wall/ Junction Insulation Above Slab (Screed) Edge Concrete slab Edge AVCL/Slip layer The use of an insulated is more thermally efficient as it eliminates these causes of thermal bridging. With increasing levels of it is vitally important to ensure continuity of the at the junction of elements and around door and window openings. At the junction of the floor and the wall a vertical section of, at the floor edge, or extending the below the floor level, can reduce thermal bridging (See Figures 4, 5, 6 & 7). Figure 5 Wall/ Junction Insulation Above Slab (Timber ) DPM Figure 7 Wall/ Junction (Timber ) AVCL Concrete slab Mastic sealant Timber battens DPM Screed 4 URSA Timber Frame Roll & Timber Frame Slab 5 URSA Timber Frame Roll & Timber Frame Slab

URSA TF Roll (Tim & Met) - 065_Layout 1 22/07/2015 12:38 Page 7 Design Around door and window openings careful detailing of the along with the use of proprietary insulated cavity closers can help to reduce thermal bridging (See Figures 8 & 9). In a cold roof construction the entire thickness of the loft should extend over the head of the main wall panel to the board (see Figures 10 & 11). Figure 8 Still Detail Figure 9 Jamb Detail At gable walls with warm roof construction the should be continued to the underside of the roof to ensure continuity of the wall and roof (see Figures 12 & 13). Fire Performance When used within a timber or metal framed wall constructed in accordance with this brochure URSA TF Roll & will not prejudice the fire resistance properties of the wall. Cavity barriers should be installed in accordance with Building Regulation requirements. Figure 12 Warm Pitched Roof Gable Verge Detail Warm roof Insulated cavity closer 30mm (min) Mastic sealant Vertical Pack verge with compressible mineral fibre Cavity barrier & AVCL 30mm (min) Mastic sealant Figure 10 Cold Pitched Roof Gable Detail Figure 11 Cold Pitched Roof Eaves Detail Figure 13 Warm Pitched Roof Eaves Detail URSA Loft Roll Eaves packed with compressible mineral fibre Warm roof type sarking URSA Loft Roll Eaves packed with compressible mineral fibre Mastic sealant & AVCL & AVCL Cavity barrier Cavity barrier & AVCL 6 URSA Timber Frame Roll & Timber Frame Slab 7 URSA Timber Frame Roll & Timber Frame Slab

URSA TF Roll (Tim & Met) - 065_Layout 1 22/07/2015 12:38 Page 9 Installation Heat Loss Calculations Insulation Between Timber Studs (see Figure 14) The usual procedure for construction is: 1. The timber frame, OSB or plywood, breather etc are all installed in the normal manner. 2. The external finish of brickwork, tile hanging or external render is then installed. 3. The is fitted tightly between the studs, normally fully filling the stud depth. 4. The internal lining of air and vapour control layer (AVCL) and plasterboard are then fixed in the normal manner. 5. An enhanced U-value may be achieved by installing additional internally or externally to the timber frame. Check with the timber frame manufacturer for specific requirements and details. Insulation Between Metal Studs (see Figure 15) The usual procedure for construction is: 1. The metal framing is installed in accordance with the manufacturer s instructions. 2. The external finish of brickwork, tile hanging or external render is then installed. 3. The is fitted tightly between the studs, normally fully filling the stud depth. 4. The internal lining of air and vapour control layer (AVCL) and plasterboard are then fixed in the normal manner. 5. An enhanced U-value may be achieved by installing additional, partial fill, cavity wall external to the steel frame. Check with the steel frame manufacturer for specific requirements and details. Other forms of external finish such as tile hanging, render, timber weatherboarding, PVC-U cladding etc are also suitable and should be fixed in accordance with the manufacturer s instructions. Figure 14 Insulation Between Timber Studs Figure 15 Insulated Metal Frame AVCL Structural timber frame Stainless steel wall tie sheating Waterproof breather External cladding Cavity Light steel studs The normal method of calculating U-values in floors, walls and roofs is the Combined Method (see BS EN ISO 6946) which as well as assessing the thermal bridge effect of mortar joints, timber studs etc also accounts for air gaps in the and mechanical fasteners penetrating the. Compliance with the Building Regulations is shown by limiting the overall CO 2 emissions from the building this gives considerable design flexibility but there are no specific U-values, except the worst allowable, that must be achieved. Typical Construction Between Timber Studs; 103mm brick 50mm clear cavity 9mm OSB URSA TF Roll, URSA or URSA HOMETEC 32 Vapour control layer 12.5mm Timber frame proportion of 15% In new build a U-value of 0.24 W/m 2 K or better will help ensure compliance. In extensions a U-value of 0.28 W/m 2 K is required and in refurbishment work 0.30 W/m 2 K is required. The Building Regulations (Scotland) require a U-value of 0.22 W/m 2 K or better. The Building Regulations (Wales) require a U-value better than 0.21 W/m 2 K in new dwellings. URSA TF Roll 40 (mm) U-Value (W/m 2 K) U-Value (W/m 2 K) (Standard breather ) (Reflective breather ) 90 0.42 0.34 140 0.30 0.26 URSA TF Roll 35/ U-Value (W/m 2 K) U-Value (W/m 2 K) 35 (mm) (Standard breather ) (Reflective breather ) 90 0.38 0.32 140 0.27 0.24 Cavity Wall tie system URSA HOMETEC 32/ U-Value (W/m 2 K) U-Value (W/m 2 K) 32 (mm) (Standard breather ) (Reflective breather ) 90 0.37 0.31 140 0.26 0.23 External cladding The use of an insulated plasterboard laminate can further improve these U-values. Please contact the URSA UK Technical Department for more information. 8 URSA Timber Frame Roll & Timber Frame Slab 9 URSA Timber Frame Roll & Timber Frame Slab

URSA TF Roll (Tim & Met) - 065_Layout 1 22/07/2015 12:38 Page 11 Technical Details Specification Clause The stud wall shall be... mm thick URSA TF Roll 40, URSA TF Roll 35, URSA 35, URSA TF Slab 32 or URSA HOMETEC 32 unfaced glass fibre roll/slab. Insulation to be installed as work proceeds in accordance with URSA UK Ltd instructions. Thermal Conductivity Declared thermal conductivity of URSA TF Roll 40 is 0.040 W/mK. Declared thermal conductivity of URSA TF Roll 35 and URSA 35 is 0.035 W/mK. Declared thermal conductivity of URSA HOMETEC 32 and URSA 32 is 0.032 W/mK. Declared thermal conductivity tested to BS EN 13162. Density Nominal density of URSA 40 is 12 kg/m 3. Nominal density of URSA TF Roll 35 and URSA TF Roll 35 is 18.5 kg/m 3. Nominal density of URSA HOMETEC 32 is 32 kg/m 3. Nominal density of URSA 32 is 29 kg/m 3. Designation Code URSA HOMETEC 32; MW EN 13162 T3 WS MU1. URSA 32; MW EN 13162 T3 WS MU1. URSA TF Roll 35; MW EN 13162 T2 DS(70,-) MU1 AFr5. URSA 35; MW EN 13162 T2 DS(70,-) MU1 AFr5. URSA TF Roll 40; MW EN 13162 T1. Reaction to Fire Euroclass A1 to BS EN 13501-1. Moisture Vapour Transmission has minimal resistance to the passage of water vapour thus allowing the wall to breathe. A practical value for the moisture vapour resistivity is 5 MNs/gm. Specific Heat Capacity The specific heat capacity is 0.84 kj/kgk. Environmental Information BRE Green Guide All URSA GLASSWOOL products achieve the best possible A+ rating under the BRE Green Guide. URSA TF Roll 35 Dimensions (mm) (m) (mm) URSA 90 6.50 2 x 570 140 4.25 2 x 570 URSA HOMETEC 32 (mm) (m) (mm) 140 2.70 1200 (mm) (mm) (mm) 90 & 140 1200 570 URSA TF Roll 40 (mm) (m) (mm) 90 9.50 2 x 570 140 6.50 2 x 570 Durability When correctly installed, URSA GLASSWOOL products are maintenance free and have an indefinite life at least equal to that of the building. Storage URSA GLASSWOOL products are supplied wrapped in polythene to provide short-term protection. On site the rolls should be stored clear of the ground, on a clean level surface and preferably under cover to protect them from prolonged exposure to moisture or mechanical damage. Chemical Compatibility URSA GLASSWOOL products are compatible with all common construction materials, alkalis, dilute acids, mineral oil and petrol. Products that have been in contact with harsh solvents, acids or saturated with water should not be used. Health and Safety URSA GLASSWOOL products are inherently safe to handle. During cutting or handling any dust generated is of nuisance value only; the wearing of dust masks, gloves and long sleeved clothing is recommended. Large scale machining should be connected to a dust extraction system. A comprehensive Health and Safety data sheet is available from URSA UK Ltd upon request. Availability is available nationally through distributors and builders merchants. References The Building Regulations and supporting documents. Thermal Insulation: avoiding risks (2002). Accredited Construction Details and Accredited Construction Details (Scotland). CIBSE Guide A3 - Thermal Properties of Buildings and Components. BS 5250 Code of Practice for Control of Condensation in Buildings. BS 5268 Structural Use of Timber. Code of Practice for Timber Frame Walls. BS EN 845 Specification for Ancillary Components for Masonry. Ties, Tension Straps, Hangers & Brackets. BRE Special Digest SD2 Timber frame dwellings: U-values and the Building Regulations. BRE Special Digest SD6 Timber frame dwellings: Section 6 of the Domestic Technical Handbook (Scotland): Energy. BRE Digest 465 U-values for light steel-frame construction. BRE Digests, Information Papers and Good Building Guides. 10 URSA Timber Frame Roll & Timber Frame Slab 11 URSA Timber Frame Roll & Timber Frame Slab