TRANSFORMER TYPES. Potential Transformers

Similar documents
Current Transformers

0.84" x 2.00" Z-TRAUQ INC. Tel.: (450) Fax: (450) z-trauq@qc.aira.com SPLIT CORE CURRENT TRANSFORMER MODEL 1SP.

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Current & Instrument Transformers

Z-TRAUQ INC. Tel.: (450) Fax: (450)

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

Tape Wound, Split Core and Ebony Current Transformers

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

GUIDE FOR TESTING POWER TRANSFORMERS

Medium-voltage transformers

T Substation Maintenance and Commissioning Test Equipment

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Safety technique. Emergency stop module BO 5988 safemaster

4 Posiflow Proportional Solenoid Valves

Tamura Closed Loop Hall Effect Current Sensors

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Table of Contents. TransformerIQ FAQs 1

Secondary Unit Substations

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Tape Wound, Split Core and Ebony Current Transformers

CURRENT TRANSFORMERS INSTALLATION GUIDE

LOW-VOLTAGE CURRENT TRANSFORMERS

Earth Fault Detection Basics in Theory

Everything you need for protection scheme testing

Vario-Series Accessories

Enhanced Quality with a Touch of Style

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

How To Choose A Transformer

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Current Transformer (CT) Selection Guide

Pluggable interface relays CR-P Pcb relays

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Unified requirements for systems with voltages above 1 kv up to 15 kv

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

UFES Active protection for switchgear

CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Vrieswijk, T & Srinivasan,A Amerongen,NL, 25 januari 2012

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

DS 600. A contact free flux gate based current measurement sensor 600A rms

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Voltage Regulator SPAU 341 C. Product Guide

leader in voltage regulators since 1946

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

LC/LCD ranges level controllers

Current Transformers Ratio / Polarity / Types

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Current transformers (CT) & Shunts

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

ACS-30-EU-EMDR-10-MOD

Quick Connect. quick - simple - efficient.

Power Meter Series 700

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Short Circuit Current Calculations

A project to optimise quality and energy efficiency must include metering

Electronic overload relay EF65, EF96 and EF146

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

DS1 Diode-based transient-free capacitor switch

Industrial Control Power Transformers

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Circuit Breakers. Next Generation of Protection Capabilities

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

49 Series - Relay interface modules A. Features

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

keep your measure under control

7.5 Watt AC-DC Switch Power Supply

The complete range of consumer switchboards and switchgear

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Medium voltage product. Instrument transformers for indoor applications Product overview

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Electronic overload relay EF19 and EF45

3-phase, bidirectional energy meter

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Digital Pressure Measuring Instrument MDR480

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

Metal Clad Indoor Instrument Transformer for Plug-In Systems

ABB PSPS Erich Steinmann; Generator control-2013

Heating, air-conditioning, cooling

Transcription:

Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 TRANSFORMER TYPES Instrument transformers Instrument transformers comprise a large category of current and potential transformers for various voltage, frequency and physical size ranges. We have broken them up into several different groupings: low voltage, which are system voltages under 15kV; high frequency, operating frequency over 1kHz; and size ranges from board mount parts up to current transformers with window sizes of 254mm by 610mm. Read through the different types we supply below and use our Instrument Transformer RFQ Form to request a specific part to meet your requirements. Potential Transformers Used primarily in a step down environment to monitor voltage. They are designed for connection line-to-line or line-to-neutral in the same manner as ordinary voltmeters. The secondary voltage bears a fixed relation with the primary voltage so that any change in potential in the primary circuit will be accurately reflected in the meters or other devices connected across the secondary terminals.

Potential transformers can be used with voltmeters for voltage measurements or they can be used in combination with current transformers for watt-meter or watthour meter measurements. They are used also to operate protective relays and devices, and for many other applications, Since they are used in a monitoring capacity, they generally require much greater accuracy in design. Metering Toroidal Current Transformers Traditional, window type current transformers for measuring 50-400HZ currents of 5A to 15000A with secondaries of 0.1A, 1A and 5A (special secondary currents are available). Burden: B 0.1 through 1.8 (2.5VA to 50 VA) with Accuracy class: 0.2 to class 5.0 as per IEC 185 or class 0.3, 0.6 or 1.2 as per ANSI C 57.13. Inside diameters of up to 8.00". Many models are available as U.L. recognized devices. Applications include: UPS systems Transfer switches Motor-generator sets Commercial sub-metering, 3 CT 's in one package for 3-phase metering Accurate measuring for metering/watt/var Current sensing, recording, monitoring & control Control panels and drives Standard CT used as measuring standard for comparison Winding temperature indicator (WTI) for power transformers Summation current transformers. Large Frame Current Transformers

For measuring 50-400HZ currents in bus bar and other large conductor systems. Typical configuration is 400A to 12000A primary current with secondary of 1A or 5A (special secondary currents are also available). Inside areas as small as 3.00" X 7.00" and as large as 7.00" X 27.00" and 10.00" X 24.00". All models are available with optional mounting plates for "bulk-head" mounting. Some models are U.L. recognized devices. Split-Core Current Transformers This type of current transformer is available to measure AC currents from 100A to 600A, at 50 to 400HZ. They are very popular in sub-metering applications where existing systems are being upgraded and it is impractical to isolate the primary conductor. It is even possible to install this type of transformer while the conductor is energized, however it is paramount that certain safety precautions be followed under such conditions. Rectangular in shape, standard split-core models are available with window dimensions up to 4.00" X 7.50". Even larger, custom designed sizes are available by special order. Secondary ratings of 5A, 1A, and 100ma are all common in split-core current transformers. Two model groups are available, SP and SPS. The former is provided with a stainless steel screw-clamp band securing the two core halves; the latter has a UV resistant nylon band. All ratios are available in either type. Electrical and magnetic performance is identical for the two groups. Miniature Current Transformers These are constructed using one of the following methods: Plastic casing, Resin casted, Resin dipped, Tape insulated,. Typical turns ratio: 4000 : 1 to 500 : 1 and Accuracy: Class 0.1 to Class 1.0. Applications include: Energy meters for accurate current measurement Current control Current signature of motors Load sensing Ground fault sensing

Monitoring of process parameters AC level to logic conversation & bar graph As a transducer in instrumentation Relay Class Protection Current Transformers This type of CT includes oil-immersed bussing and Resin molded versions. Primary current range from 5 Amp to 5000 Amp with secondary current 5A, 1A, or 01.A. Typical Burden B 0.1 through B 4.0 (2.5VA to 50 VA & more) and Accuracy Class As per ANSI C 57.13 and IEC 185. Applications include: Protection relays/relay panels Earth fault protection Bussing type, oil-immersed CT in power transformer Control panes and switch boards Air/Gas circuit breakers Motor control cubicles Power control centers Bus bar protection systems Differential protection systems Medium voltage Instrument Transformers These are used with a system voltage 3.3kV to 25kV and BIL 4.5 to 125 full wave crest kv. They are reliably constructed using vacuum cast with epoxy resin/polyurethane resin and are able to withstand heavy fault conditions but are not made for exposure to sunlight.. Single CT's can be built with multiple cores; for example - one for measuring and another for relaying are possible. Also multitap secondaries can be provided (up to 4). Typical primary current 5 Amp to 3000 Amp and secondary current 5A/1A/01.A. Applications include:

Metering and Relaying Energy meter panels Medium voltage switch gears and control panels Medium voltage circuit breakers Motor Control Panels PC mount 50 to 400Hz Current Transformers These offer a small footprint for the design engineer looking to sensor current on board. They can also be used for Metering Class (Burden from B O.1 to B 1.8 with accuracy class from 0.3 to 2.4 as per customer requirement. (As per ANSI C 57.13 and IEC 185) and for Relay Class Burden from B 1.0 to B 4.0 and relay voltage class from C 10 to C 400 or T200 as per customer requirement. (As per ANSI C 57.13 and IEC 185) Secondary current range from 0.1 to 5 amp. Typical constructions are plastic casing or resin molded. Applications include: Sensing current overload Ground fault detection Metering PC mount 2OkHz to 2OOkHz Current Transformers These are used for measuring high frequency primary currents up to 15 Amps with primary to secondary isolated to 2500 VAC and have optimum performance over designated current and frequency ranges. Applications include: Isolated current feed-back signal in switch mode power supplies Motor current load/overload Lighting Switch controls Ultra-sound current High resolution sonar current Isolated bi-directional current sensor with full wave bridge