GROUNDING AND BONDING. Table of Contents. Minimum Size Bonding, Equipment Grounding, Grounding Electrode Conductor Table

Similar documents
STREETLIGHT SYSTEM GROUNDING AND BONDING

Electrical Code Regulation

Grounding & Bonding Why it is done And How to Install Properly

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Hyperlinks are Inactive

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

IRRIGATION PUMPING Table of Contents - Section 900

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

Electrical Service Guidelines

BASIC NEC CODE RULES AND DESIGN PRACTICE

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Mobile Home Pre-Inspection Checklist

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

The Service Entrance. Technical Terms Drip loop Insulator Meter Meter enclosure

ELECTRIC SERVICE HANDBOOK General Information Residential Service Portable/Standby Generators Temporary Service Commercial Service Metering

Please check with your local inspection authority for any additional requirements before installation.

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

How To Get A Power Line Extension

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

MOBILE HOME SERVICE REQUIREMENTS GAS

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

800 Communications Circuits

Chapter 9. Bonding and Grounding

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

Residential Electrical Inspection. Checklist

Residential Electrical Inspection. Checklist

Customer Substation Manual 08/05/02

Electrical Grounding. Appendix C

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

TABLE OF CONTENT

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

New Residential Service Requiring Construction

City of Riverside Building & Safety Division Phone: (951)

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Residential Electrical Inspection Checklist

ELECTRICAL SAFETY Information Bulletin

ELECTRIC SERVICE HANDBOOK

Electric Service Guide for Residential Construction

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

How Much Voltage Drop Is Acceptable?

CITY OF LOS ANGELES CALIFORNIA

SERVICE - GENERAL Residential, Commercial, Industrial

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL

Policy and Guidelines for Electric Service

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

David Brender Copper Development Association Inc. Miramar, March 8, 2013

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

GROUNDING AND BONDING ELECTRICAL SYSTEMS

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

TC Grounding and Bonding for Telecommunications Systems

San Diego Area Chapter International Code Council

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

NEC 2014 Code Changes

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

Services. Three Phase Service

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

Underground Service Requirements and Instructions

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Electric Service Standards

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Requirements for Electrical Installations

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS

Electric Service Guide for Residential Construction

Electric Service Guide for Commercial Construction

CHAPTER 2 EXAMPLES AND TABLES

ELECTRICAL INSPECTION BULLETIN (Effective )

Electric Service and Meter Installations Manual SCANA Corporation 2013

County of Riverside Building and Safety Department

Application of Four-Pole Circuit Breakers within Data Centers

Entrances to and from Electrical Equipment Rooms

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

Electric Service Rules

Underground Commercial Electric Service

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

Questions and Answers for Heating and A/C Contractors

Short Circuit Current Calculations

Guide for Electric Service and Meter Installations

INSPECTION GUDELINES

Electric Service Manual

How To Plan Out An Array Of Solar Panels

2012 Edition Redbook 11.0 GENERAL DRAWINGS AND STANDARDS

Transcription:

GROUNDING AND BONDING Table of Contents Grounding Bonding Minimum Size Bonding, Equipment Grounding, Grounding Electrode Conductor Table Typical Residential Service Grounding and Bonding Drawing (overhead) Typical Residential Service Grounding and Bonding Drawing (underground) Typical Mobile Home Meter Pedestal Grounding and Bonding Drawing Proper Grounding and Bonding Drawing Short Circuit Protection

GROUNDING The ground electrode conductor shall be bare. Ground electrode conductors shall be a minimum size of No. 4 copper (solid or stranded) and must be securely fastened to the building or structure with approved fastening devices. The spacing of such devices shall not exceed 2 feet. Aluminum wire is not acceptable to be used as the grounding conductor. When a ground rod is used as the grounding electrode, it shall be a minimum 5/8 inch X 8 foot copper clad ground rod driven vertically into the ground. Where a rock bottom is encountered, the ground rod shall be driven at an oblique angle not to exceed 45 degrees from the vertical or shall be buried in a trench that is at least 2 1/2 feet deep. The ground rod shall be installed so that at least 8 feet of rod is in contact with the soil. The ground rod connector shall be of a type approved for direct burial. Not more than one conductor shall be connected to the grounding electrode by a single clamp, unless the clamp is listed for multiple conductors. The grounding electrode shall have a resistance to ground of 25 OHMS or less. Where the resistance exceeds 25 OHMS, two or more electrodes in parallel not less than 6 feet apart shall be used to obtain the necessary resistance to ground. When a concrete enclosed electrode (UFER Ground) is used, it shall be encased by at least two (2) inches of concrete foundation or footing that is in direct contact with the earth, consisting of at least 20 feet or more of bare solid copper conductor not smaller than No. 4 AWG. When a UFER Ground is used, it must be inspected by either the inspector within whose jurisdictional boundary it lies or, if in an area not requiring such inspection, by an approved Cooperative employee, prior to being encased in the concrete. The grounding electrode conductor shall contain no splices from the equipment it is intended to ground to the grounding electrode it is connected to. A natural gas or liquid propane gas line shall not be used as a grounding electrode.

BONDING (Unfused Areas) Bonding is required on all enclosures, equipment, raceways, and fittings which contain unfused service conductors. Nipples and bushings installed with eccentric or concentric lock nuts must be bonded with ground bushings, wedges, or other approved devices. Bond conductor size shall be determined by the ampere rating of the service entrance equipment as shown on the grounding and bonding table. Bonding jumpers shall be installed around any section of non-metallic duct, pipe, device or fitting that will break the continuity of the ground. Self bounding hubs (Myers or equivalent) shall not be used on multi-centric knockouts, unless the largest knockout is used. All metallic parts of an irrigation system which are not intended to carry current must be permanently bonded to an unfused and unswitched ground conductor which extends back to the transformer bank secondary ground. It is not satisfactory to merely bond the equipment to a driven ground rod or well casing if that ground rod or casing is not interconnected with the transformer ground by metallic conductor. This means that in all cases, the consumer's wiring must consist _ four wires. These wires are the three current-carrying phase conductors and a fourth wire called a grounding conductor. A grounding conductor is one which is not intended to carry load current, but instead, provides the interconnection between the transformer bank ground and all grounds on the consumer's equipment and shall be sized as shown in N.E.C. 250-94. Interior metal water piping systems shall be bonded to the service entrance enclosure with conductor sized to the ampacity of the main bus per National Electric Code (N.E.C.) 250-94. In multiple occupancy buildings where the interior metal water piping system for the individual occupancies is isolated from all other occupancies by use of non-metallic pipe, each water system may be bonded to the panel board or switch board enclosure supplying that occupancy sized per N.E.C. 250-95. Other metal piping systems (e.g. gas pipe) shall be bonded to the service equipment enclosure with a conductor sized to the largest branch circuit or feeder supplying the facility, sized per N.E.C. 250-95. Bonding of gas pipe shall be made on the House side of the insulated coupling located adjacent to gas meter. Non-conductive paint must be removed at threads terminal strips, etc., to assure a good electrical connection. Insulated bounding conductors shall have a green insulation.

GROUNDING AND BONDING TABLE MINIMUM SIZE OF BONDING/EOUIPMENT GROUNDING, GROUNDING ELECTRODE CONDUCTORS AND GROUND BUS Maximum Ampere Rating NOTES: Size of Equipment Grounding or Bonding Conductor Minimum (AWG or MCM) NEC 250-95 See Note 1 1. For sizing bonding conductor for gas line, per N.E.C. 250-122. For sizing any bond conductor required on The Load Side of Fuses or Circuit Breakers. 2. For sizing water bonds per N.E.C. 250-66. Size of Grounding Electrode Conductor Minimum (AWG or MCM) NEC 250-94 See Note 2 & 4 3. For sizing main bonding jumper from equipment grounding bus to neutral bus, per N.E.C. 250-102. For sizing conductor used for bonding unfused nipples and equipment. 4. Grounding electrode conductors need not be larger than #4 copper if there is only one connection between the concrete encased electrode or man made electrode (example ground rod) & grounded system conductor (neutral conductor), per N.E.C. 250-66 ex.1-a and b. Size of Main Bonding Jumper, Minimum (AWG or MCM) NEC 250-79 See Note 3 Copper Aluminum Coper Coper Aluminum 20 12 10 60 10 8 90 8 6 100 8 6 4 6 4 150 6 4 4 6 4 200 6 4 4 4 2 300 4 2 2 2 1/0 400 3 1 1/0 1/0 3/0 500 2 1/0 1/0 1/0 3/0 600 1 2/0 2/0 2/0 4/0 800 1/0 3/0 2/0 2/0 4/0 1000 2/0 4/0 3/0 3/0 250 1200 3/0 250 3/0 250 250 1600 4/0 350 3/0 300 400 2000 250 400 3/0 400 500 2500 350 500 3/0 500 700 3000 400 600 3/0 600 750 4000 500 800 3/0 750 1000 5000 700 1200 3/0 900 1250 6000 800 1200 3/0 1250 1500

GROUNDING AND BONDING TYPICAL RESIDENTIAL OVERHEAD SERVICE ALL IN ONE (SINGLE FAMILY) MAX 200 AMP SINGLE PHASE GROUNDED (NEUTRAL) SERVICE ENTRANCE CONDUCTOR SERVICE ENTRANCE RACEWAY MUST BE A RAIN TIGHT DEVICE IF BOLTED HUB OR SELF BONDING HUB IS USED BONDING JUMPER IS NOT REQUIRED (N.E.C. 250.97 a b c & d) size BONDING JUMPER PER N.E.C. 250.102 SERVICE DISCONNECT ENCLOSURE NEUTRAL TERMINAL BUS WHERE NEUTRAL TERMINAL IS INSULATED FROM THE ENCLOSURE, INSTALL A BONDING JUMPER OR SCREW (SEE N.E.C. 250.28 AND N.E.C. 250.102) NEUTRAL DISCONNECT MEANS (SEE N.E.C. 230.75) BARE OR INSULATED GROUNDING ELECTRODE CONDUCTOR (SEE N.E.C. 250.62 FOR MATERIAL N.E.C. 250.62(b)FOR INSTALLATION AND N.E.C. 250.66 FOR SIZE) SIZE BOND CONDUCTOR FOR METAL WATER PIPING PER N.E.C. 250.66 CONNECTION TO ELECTRODE CONNECT GROUNDING ELECTRODE CONDUCTOR TO GROUNDING ELECTRODE WITH APPROVED GROUND CLAMP (SEE N.E.C. 250.70) GROUNDING ELECTRODE SYSTEM (SEE N.E.C. 250.50) OTHER METAL PIPING N.E.C. 250.52(a7) SIZE BOND CONDUCTOR PER N.E.C. 250.122

GROUNDING AND BONDING TYPICAL RESIDENTIAL UNDERGROUND SERVICE (SINGLE FAMILY)MAX 200 AMP. SERVICE DISCONNECT ENCLOSURE WHERE NEUTRAL BUS IS INSULATED FROM THE ENCLOSURE. INSTALL A BONDING JUMPER OR SCREW (SEE N.E.C. 250.28 AND N.E.C. 250.102) NEUTRAL DISCONNECT MEANS (SEE N.E.C. 230.75) METAL WATER PIPING PER N.E.C. 250.66 PULL SECTION (N.E.C. 250.104(a)) OTHER METAL PIPING PER N.E.C. 250.122 (N.E.C. 250.52(a7)) IF BOLTED HUB OR SELF BONDING HUB IS USED, BONDING JUMPER IS NOT REQUIRED (N.E.C. 250.97 abc&d) SERVICE ENTRANCE RACEWAY BARE OR INSULATED GROUNDING ELECTRODE CONDUCTOR (SEE N.E.C. 250.62 FOR MATERIAL, N.E.C.250.64 FOR INSTALLATION, AND N.E.C. 250.66 FOR SIZE). CONNECTION TO ELECTRODE CONNECT GROUNDING ELECTRODE CONDUCTOR TO GROUNDING ELECTRODE WITH APPROVED GROUND CLAMP SEE N.E.C. 250.70 GROUNDING ELECTRODE SYSTEM SEE N.E.C. 250.50 WHERE METALLIC SERVICE RACEWAY IS INSTALLED WITH LOCKNUTS, INSTALL A GROUND BUSHING OR DEVICE AND BOND TO THE ENCLOSURE (SEE N.E.C. 250.97 a b c & d) GROUNDED (NEUTRAL) SERVICE CONDUCTOR.

WHERE NEUTRAL BUS IS INSULATED FROM THE ENCLOSDURE, INSTALL A BONDING JUMPER OR SCREW TO THE PEDESTAL (SEE N.E.C. 250.28 NEUTRAL DISCONNECT MEANS SEE N.E.C. 230-75 NEUTRAL LANDING TERMINAL GROUNDED (NEUTRAL) SERVICE CONDUCTOR GROUNDING ELECTRODE CONDUCTOR (SEE N.E.C. 250.62 FOR MATERIAL, N.E.C. 250.64 FOR INSTALLATION, AND N.E.C. 250.66 FOR SIZE CONNECTION TO ELECTRODE CONNECT GROUNDING ELECTRODE CONDUCTOR TO GROUNDING ELECTRODE WITH APPROVED GROUND CLAMP. (SEE N.E.C. 250.70) GROUNDING ELECTRODE SYSTEM. (SEE N.E.C. 250.50, AND N.E.C. 250.52 a thru b)

CONNECTION FOR MAIN BOND JUMPER AHEAD OF NEUTRAL DISCONNECT LINK. NEUTRAL DISCONNECT LINK MAIN BONDING JUMPER(S) N.E.C. 250.28 N.E.C. 250.102 SIZE PER N.E.C. 250.102 ALL NEUTRAL WIRES TO BE PLACED ON NEUTRAL BUS. ALL BOND WIRES N.E.C. 250.28 TO BE PLACED ON BOND BUS. ENCLOSURE GROUNDED N.E.C. 250.80. (A WIRE MAY NOT BE NECESSARY IF GROUNDING BUSBAR HAS BEEN INSTALLED ON A CLEANED SURFACE OF THE FRAME WITH BOLTS OF ADEQUATE SIZE AND STRENGTH.) TO GROUNDING ELECTRODE N.E.C. 250.70 SIZE PER N.E.C. 250.66 PIPING SYSTEMS PER N.E.C. 250-80 METAL WATER PIPING PER N.E.C. 250.104a, SIZE PER N.E.C. 250.66 OTHER METAL PIPING PER N.E.C. 250.52a7, SIZE PER N.E.C. 250.122

SHORT CIRCUIT PROTECTION The national electric code, state, county and municipal codes and/or regulations require that service entrance equipment shall be suitable for the short circuit current available at its supply terminals. It is the responsibility of the consumer to install service entrance equipment and protective devices (fuses or circuit breakers) capable of interrupting and withstanding the available fault current. RESIDENTIAL The cooperative will design its facilities, where practicable, so that the maximum fault current will not be greater than 10,000 amperes-symmetrical at new single-family residences having service entrances nominally rated at 200 amperes or less. (There may be exceptions to this rule due to size and location of transformers, and also when serving townhouses, condominiums and apartments, consult with the cooperative in such cases.) COMMERCIAL & INDUSTRIAL (600 AMPS & BELOW) Table No. I specifies the minimum interrupting rating of service entrance equipment that shall be installed. In some cases, the available fault current may exceed these values and higher rated equipment may be required when the company elects to serve from a larger multiple service transformer. (See Table No. III) TABLE NO. I Current values shown are symmetrical amperes at the secondary terminals of the transformers. Minimum Short Circuit Rating (AMPS) Service Single Phase Three Phase Entrance 120/240 V 120/208 V 277/480 V 120/240 V Ampacity Pole Pad Pole Pad Pole Pad Pole Pad 200 or Less 13,000 10,700 13,000 21,700 11,300 12,400 11,300 N/A 400 26,000 20,000 26,000 21,700 22,500 23,600 22,500 N/A 600 41,000 31,300 39,000 41,800 35,500 24,300 34,000 N/A N/A Not Available

COMMERCIAL & INDUSTRIAL (800 AMPERES & ABOVE) Sometimes it is necessary to order switchgear before sufficient design data is available to make a detailed fault study. For this reason, the cooperative lists maximum fault tables that should permit the proper sizing of pre-ordered switchgear. Care must be exercised in using these tables. Table No. II gives maximum faults at the seconday bushing of the transformer. Table No. II may be used only when the cooperative will serve the section with a single transformer installation. Example: A commercial enterprise has had a facility designed and the electrical engineer has determined that the SES will be 1,000 AMPS and the voltage will be 120/208 3ø. From Table No. II it can be found that the short circuit available is 52,100 for pole type transformers and 54,400 for pad type transformers. TABLE NO. II Current values shown are symmetrical amperes at the secondary terminals of transformers. Service Entrance Equipment Capacity Assumed SES Loading at 80% Capacity 120/240 V 120/208 V 277/480 V Pole Pad Pole Pad Pole Pad 800 640 45,000 39,000 41,800 35,500 24,300 1,000 800 66,100 52,100 54,400 47,500 24,300 1,200 960 70,800 81,700 56,100 47,500 24,300 1,600 1,280 70,800 81,700 56,100 54,700 24,300 2,000 1,600 95,000 81,700 56,100 75,300 31,500 Not Available

COMMERCIAL & INDUSTRIAL Table No. III shall be used when the cooperative serves the customer from a transformer with multiple services. This table can be used only when the ultimate size of the transformer is known. (Consult with the cooperative for that decision) Example: A commercial enterprise is bding built in an existing shopping center where the electrical facilities are already established. The requirements are for a 400 AMP SES 277/480 V. Verification with the cooperative reveals that a 500 KVA pad mounted transformer is already serving adjacent businesses and could accept this load. From Table No. III, after 500 KVA transformer, find the utility short circuit current available to be 24,3000 AMPS. TABLE NO. III Current values are symmetrical amperes at the secondary terminals of the transformer. Transformer Bank KVA 1 ø 120/240 V 120/240 V 120/208 V 277/480 V 240/480 V 1 ø or Pole Pad Pole Pad Pole Pad Pole Pad Pole 25 * * N/A N/A N/A N/A N/A N/A N/A 37 ½ * * N/A N/A N/A N/A N/A N/A N/A 50 13,000 13,000 N/A N/A N/A N/A N/A N/A N/A 75 19,500 19,500 11,300 N/A 13,00 10,420 * * * 100 26,000 26,000 N/A N/A N/A N/A N/A N/A N/A 122 ½ N/A N/A 16,900 N/A 19,500 21,700 * * * 150 N/A N/A 22,600 N/A 26,000 28,500 11,300 12,400 11,300 167 40,900 40,900 N/A N/A N/A N/A N/A N/A N/A 225 N/A N/A 33,800 N/A 39,600 41,800 16,900 18,100 11,900 300 N/A N/A 45,100 N/A 52,100 54,400 22,500 23,600 22,500 500 N/A N/A 71,00 N/A 81,900 56,100 35,500 24,300 35,500 750 N/A N/A 95,00 N/A ** ** 47,500 24,300 47,500 1000 N/A N/A N/A N/A ** ** 54,700 24,300 54,700 1500 N/A N/A N/A N/A ** ** 75,400 36,100 75,400 * Available short circuit current 10,000 AMPS or less ** Conlult with the cooperative *** transformer installations assume three equal sixe transformers. If transformers are not equal in size, use larger transformer and table for 3 transformers N/A Not available