TRS 06 TRANSPONDER READER- AND CONTROL UNIT. (Door Access Control System) Mounting Manual and Operating Manual

Similar documents
Digital Keypad Use s Manual

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

AC-115 Compact Networked Single Door Controller. Installation and User Manual

PROXIMITY CARD READERS C-10, C-20, C60, C70

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

PAC1 Door Access Controller

VARIO PROX CARD READER INSTALLATION MANUAL

User Manual. Before installation and use, please read the user manual carefully.

Shunt lock function 3066

AUTODIALLER / QUICKDIALLER - SA132

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

P10 - Standalone Access Controller and Reader

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

CONTENTS 4. HOW TO UNSET THE PANEL...7

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

SYSTEM 45. C R H Electronics Design

9452/9453 Installation and User Guide

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

INSTALLATION MANUAL XM3 Reader

FIREDEX Conventional Fire Panels

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

SYSTEM 4C. C R H Electronics Design

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

ABB Drives. User s Manual HTL Encoder Interface FEN-31

2M IR Mini Dome Quick Installation Guide

Microprocessor Home Security System

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

ACTIVE 5 ENGINEERING MANUAL

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

PUSH BUTTON START INSTALLATION MANUAL

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Modular I/O System Analog and Digital Interface Modules

Automatic Telephone Dialer TD-101(W)

WD-AMX Water Detection Controllers

User manual DinaSys DTC/DTS and DTC/DTZ

FSLIMRF

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Adaptability to Enhanced Security

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

IDS X-Series User Manual D Issued July 2012

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

Adaptability to Enhanced Security

Secure Keypads for access control

Combi B Alarm box. Mounting instructions

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

INSTALLATION GUIDE. FCC ID NOTICE

Installation manual. Version

Multi-Protocol decoder with Load regulation

Drayton Digistat +2RF/+3RF

Advantium 2 Plus Alarm

GSM HOME SECURITY SYSTEM

HERZ-Thermal Actuators

VTO6xxx. IP door stations. User manual

mecotron Safety relay ESTOP-2 For emergency stop monitoring

instabus KNX / EIB System System E F G H

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

INSTALLATION INSTRUCTIONS

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

PK5500 v1.1 Installation Instructions

Business/Home GSM Alarm System. Installation and User Manual

48 SERIES Relay interface modules 10 A

AR-721U/721K/661U User s Guide

Model SETR-50 and SETR-51 Trim Tab Control

How To Program An Autodialer

AD-01 Slave Auto Dialer. Owner s Manual

38 Series - Relay interface modules A

HM-W536 Install Guide

FLOOR INDICATORS CATALOGUE 2007

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

DALI RC BASIC SO. Control unit Operating instructions

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: Fax:

Multifunction devices

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

Fire Pump Controllers Remote Alarm Panels

TMS TANK MANAGEMENT SYSTEM

PRT3 Printer Module: ASCII Protocol Programming Instructions

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

MAGICAR M871A. Car alarm with two-way remote User s guide

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

GST301. (Single Protection Zone) Operation Manual

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Fire Alarm Control Panel. Family. Operating Manual

Transcription:

TRS 06 TRANSPONDER READER- AND CONTROL UNIT (Door Access Control System) Mounting Manual and Operating Manual

Table of Contents 1. Function and Description of the Device 2 2. Installation Instructions 3 2.1 Installing the Reader Head 3 2.2 Installing the Controller 4 2.3 Wiring Details of the Control Unit 4 3. Programming Instructions 6 3.1 Master Tag Programming Instructions 7 3.2 User Tag Programming Instructions 8 3.3 User Tag Deleting Instructions 10 3.4 Relay Output Time Programming Instruction 12 3.5 Last Tag Read Instructions 13 4. Technical Specifications 14 1. Function and Description of the Device The Transponder-System provides ideal access control to premises - for private as well as for office or industrial buildings and also to garages or multi-storey car parks up to 1000 users. Two versions of the Transponder-System are available: TRS06-01 has a standard reader head whereas TRS06-02 provides a vandal proof reader head. To gain access a Transponder Card registered at the control unit or a Transponder Tag can simply be held to or passed by the reader head. A high standard of security is offered by the 64-bit coding technology as it provides over a trillion coding alternatives. Special Features Auto frequency stabilization Auto deactivation Master Tag learning mode Master Tag deleting mode Individual Tag learning mode Individual Tag deleting mode Entire memory deleting Last tag reading display Sensor readerhead Fire alarm input Emergency exit Programmable relay output time (150 ms 9 s) Double reader head capability 2

2. Installation Instructions 2.1 Installing the Reader Head The reader head is pre-wired with a 2m cable. If the cable is to be replaced with a longer cable, please note the following restrictions: - unshielded cable: max. 5 m - shielded cable max. 15 m The reader head can be installed as follows: 1. Mount the reader head. Make sure that the cable is not pinched off. 2. Only regarding the standard reader head: place the reader head sticker onto the reader head and align the reader head sticker LED hole with the LED of the reader head. 3. Connect the reader head with the control unit according to the wiring details (page 5). Standard Reader Head Vandal Proof Reader Head LED Foil blue red black yellow green Connections blue buzzer (BUZ) red power supply (5V) black ground (GND) yellow loop + green loop - 3

2.2 Installing the Controller 1. Remove the cover. Insert the cables through the bottom of the cover from the backside. Secure the control unit in the preferred location using the screws and mollies. 2. Connect the reader heads (also see below) as well as the power supply and any auxiliary devices to the control unit according to the wiring details (page 5) and fasten the cover with screws. 2.3 Wiring Details Control Unit Power AC / DC 12 V AC / DC AC / DC 12 V AC / DC Reader Head + 5V red from reader head - 0V black from reader head Buzzer blue from reader head Loop + yellow from reader head Loop - green from reader head Aux - 0V bridge between RTE or Fire RTE request to exit input Fire fire alarm input (normally open) Relay N/O normally open relay contact Common common relay contact N/C normally closed relay contact Failure to follow the wiring instructions may result in permanent damage to the controller! Wiring Reader Heads In case two reader heads are to be installed the Jumper LOOP SELECT must be CLOSED and the second reader head must be wired in parallel to the controller. Please note, that this is a single door system and there is only one output relay. The two heads will therefore be fitted to the ENTRY and EXIT points on a single door. 4

Wiring Details 12 V AC/DC (1 A) + - LOOP SELECT - / AC + / AC BUZZER -OV +5V LOOP- LOOP+ -OV FIRE RTE N/C COMMON N/O Key switch Red Black Blue Yellow Reader Head Green Closing Contact Exit request Input fire alarm Magnetic Lock The fire alarm input is a facility whereby a fire alarm device such as an emergency glass break switch or fire alarm panel can close the circuit to open all doors immediately. Please note the fire alarm input is non latching, and fail safe locks should be used with this function. 5

3. Programming Instructions The Transponder TRS06 employs AUTO EXITING software for security reasons. In any of the programming modes, the controller will automatically revert back to standard operating mode if the user takes no action within 30 seconds. There are three different operating modes, as indicated by the display dot position: Standard Operating Mode Position 1 User Tag Learning Mode Position 2 Deleting Mode Position 3 Master tag learn mode Position 4 It is recommended that the user reads the user actions and controller responses carefully before attempting to program the controller. The column user action indicates the steps the user must take to accomplish a certain programming function. The column controller response indicates the response that the controller will give to a user action. 6

3.1 Master Tag Programming Instructions Only one transponder card can be used as master card. Only this card enables programming and deleting tags. Please keep your master tag in a safe place! On presenting a new master tag the entire memory will be deleted and all user tags will have to be reprogrammed! Programming Function User Action Controller Response Teaching the controller a new master tag 1. Press & hold button S1 (the top button). 2. While still holding button S1 press button S2 (the bottom button) The controller display changes to the last card read while pressing this button in standard mode. The controller will respond with three beeps immediately. After releasing buttons S1 and S2 the controller display will light up displaying: This indicates that the controller is in master tag learning mode and that the first tag to be presented to the reader will be the new mastertag. 3. Present the new tag to the reader (this will become the new master tag) The controller will respond with 3 beeps. This indicates that it has learned the new master tag and exited master tag learning mode. The controller is now ready for standard operation. 7

3.2 User Tag Programming Instructions Programming function Teaching the controller a new user tag User Action 1. Present the master tag to the reader for approx. 5 seconds. Controller Response The controller responds with a single beep. After a few seconds the controller responds with an additional 3 beeps indicating that it has entered the user tag learning mode: 2. Remove the master tag and present the new user tag(s) to be learned one at a time to the reader. Wait for response of the controller. 1 second after presenting a new user tag, the controller will respond with a single beep. This indicates that the controller has learned the new user tag. Note: Should the controller respond with 3 beeps instead, it is indicating that the 1000 user limit has been exceeded and that the controller has exited user tag learning mode. 8

Programming Function User Action 3. After teaching the controller the new user tag(s) present the master tag to the reader again to exit user tag learning mode. Controller Response The controller responds with 3 beeps indicating that it has left user tag learning mode: Note: In case the user forgets to exit user tag learning mode, the unit will automatically exit this mode after 30 seconds. Note: Deleting user tags can only be done if the number is known. After completing user tag programming present each tag to the reader again (see chapter Read Last User Tag ). Note down the number displayed e.g. together with the name of the owner. New user tags can be programmed any time. New user tags will be saved to the next free memory space. This can also be the space of a previously deleted number. 9

3.3 User Tag Voiding Instructions Programming function User Action Controller Response User tag voiding 1. Present the master tag to the reader and keep in the reader field. The controller responds with a single beep. After a few seconds, the controller responds with an additional 3 beeps indicating that it has entered user tag learn mode. 2. Press button S2 The controller responds with 3 beeps and after S2 is released is displayed. This indicates that the controller has antered user tag voiding mode. 3. Press button S2 to scroll to the user tag number that has to be voided from the system. Note: By holding button S2 in the scrolling speeed will increase. User tag that has to be voided is displayed e.g.3:: 10

Programming Function User Action Controller Response 4. To delete a user tag from the system press S1 button. The controller responds with a single beep and the display changes to:: 5. To exit user tag deleting mode do not make any input into the controller for 30 seconds. The user tag has been deleted. Unit responds with 3 beeps and enteres the standard mode. 11

3.4 Relay Output Time Programming Instruction Programming Function User Action Controller Response Adjust the door lock mechanism Relay Output Time. This function is used to set the time, for which the relay will provide an output to the door latch, in the event of a card/tag being introduced or fire exit (RTE) push button. The default setting is t1 (1 second). Note: When resetting the relay output time the door alarm settings will need to be reset at the same time. 1. Press S2 and release. 2. Continue pressing S2 to increment the timer until the required time setting is achieve. 3. Do not make any input into the unit for 30 seconds to exit this mode or press S1. Unit responds with 3 beeps and shows: t = 1 second The display shows: t = 2 seconds, up to t = 9 seconds or t = - (this is a special setting for a 150ms Pulse Output) Unit responds with 3 beeps and enteres standard mode.. 12

3.5 Last Tag Read Instructions Programming Function User Action Controller Response Looking for the last tag read 1. In standard mode press and hold S2 The number of the last tag read will be displayed. 2. Release button S2. 13

4. Technical Specifications Hardware Operating voltage: Average current consumption: 12 V AC/DC 33 ma (1 reader head) Maximum current consumption: 55 ma (12 V) Relay output rating: Operating frequency: Read Range: 24 V / 5 A Reader heads: 1 or 2 Reader head cable length: Cable: Degree of protection: Dimensions (L x W x D): Weight: 125 khz (50 Hz - 4 khz modulation) 6 cm 10 cm (dependant on tag type) 2 m standard, max. 5 m unshielded max. 15 m shielded 5-core reader head: IP54 controller: IP00 Operating temperature: -10 C to +60 C reader head: 75 mm x 39 mm x 15 mm controller: 104 mm x 94 mm x 25 mm reader head: 60 g controller: 70 g Indications: visual: bi-color-led, acoustic: Buzzer Software Programming: with master tag User tags: max. 1000 Code size: 64 bit Read time: < 2 seconds 14

83024 GB 0410