atalogue Series
Benefits of the new system olour coded lock lever according to coil voltage D Blue A Red A / D Grey ontact Type: 2 hange Over ontact Push Button and Lockable Lever with 3 functions 1. Lift to lever / lockable button 2. Push to test button / Manual test button 3. Slide Lever protection against unintentional activation of test button is a Two Pole Industrial Plug-in with all the In-Built Mechanical and Electronic features which are a must for Input / Output PL applications. Finger Grip for easy removal of relay from socket Industrial 2. mm Faston Terminals ontact NO 1(14), 7() Terminals O 2(11), 8(21) N 3(), 9() Inbuilt easy to use Retainer lip oil terminals (4, A1 +ve) (,A2 -ve) Socket marking label Industrial size combination screws ( M3 ) Standard 3mm DIN rail or Panel Mountable Socket learly visible Terminal numbering according to DIN & Euro Standards Large wire inlets (Upto 4sq mm ) for easy wiring Touch protected -Ve / A2 Looping Bridges (S2D-B1 / S2D-B4) Socket with width of 1mm S2D is a Two Pole Touch protected Interface Socket with Input / Output configuration oil Terminals ( A1 & A2 ) on one side and ontact Terminals ( NO, N, O ) on the opposite side. 1
Benefits of the new system olour coded lock lever according to coil voltage D Blue A Red A / D Grey ontact Type: 2 hange Over ontact Push Button and Lockable Lever with 3 functions 1. Lift to lever / lockable button 2. Push to test button / Manual test button 3. Slide Lever protection against unintentional activation of test button is a Two Pole Industrial Plug-in with all the In-Built Mechanical and Electronic features which are a must for Input / Output PL applications. Finger Grip for easy removal of relay from socket Industrial 2. mm Faston Terminals ontact NO 1(14), 7() Terminals O 2(11), 8(21) N 3(), 9() Inbuilt easy to use Retainer lip oil terminals (4, A1 +ve) (, A2 -ve) Socket marking label learly visible Terminal numbering according to DIN & Euro Standards Industrial size combination screws ( M3 ) Standard 3mm DIN rail or Panel Mountable Socket 16mm Socket with Width of 16mm S2LD is a Two Pole Touch protected Socket with Input / Output configuration oil Terminals ( A1 & A2 ) on one side and ontact Terminals ( NO, N, O ) on the opposite side. 1
Two Poles, hange-over ontact 6A 20V A1 0.A 110V D1 6A 30V D1 0.2A 2V D1 N NO N NO 3 1 9 7 4 14 A1 + OIL 11 21 A2-2 8 OM OM ontacts Materials: Standard, Optional, code 1 Optional, code 2 Max. switching current Max. Peak inrush current ( ms.) Max. Switching voltage Max. A load (Graph 1)* AgNi AgNi + 0.2µ Au AgNi +.0µ Au 6 A 30 A 20 V 1.A See Graph 2* 6 Graph 1 Electrical life, ops x 10 Graph 2 00 1000 100 oils (Ohms ± 10% @ º) Pull-in voltage Drop-out voltage Nominal coil power VA Ω ma VD Ω ma 11 230 Insulation 290 1.0 7.300 28.800 4.0 23.0 9. 4.7 110 Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts & coil Isolation resistance at 00VD Isolation, IE 61810- : < 0.8 x Un 0.1 x Un 1.1 VA (A) / 0.7 W (D) 2 742 3.00 19.900 < 3.0 32.0 13.7. 1.000 V 3.000 V > 3GΩ 4 KV / 3 Vdc Operate Time + Bounce Time Release Time + Bounce Time Ambient Temperature Mechanical life ops. Electrical life at nominal load Operating frequency at nominal load Protection degree 10 ms. 8 ms. -40º (no ice). +70º 10 Million A, Million D relays > 100,000 ops. 1,0 / hour IP40 / RT1 21 gms. 0. 2. 36 13 Max. 7. 7 1 A1 A2 4 9 29 Max Standard types A 0 Hz :,, 11, 230 F = Mechanical Flag Indicator P = LED R = R, (Snubber ircuit) D,,, 110 F = Mechanical Flag Indicator P = LED W = Free Wheeling Diode Z = Polarity & Free-Wheeling Diodes I = Lockable & Manual Push Button B = A/D Bridge Rectifier (/V) Suitable Sockets : S2D, S2LD, S2P -F -FP -FPR -F. VD -FP. VD -FPW... VD -FPZ -FPZI -FPB. VA. VA... VA. VD. VD. AD
-FW() Two Poles, hange-over ontact 6A 20V A1 0.A 110V D1 6A 30V D1 0.2A 2V D1 N NO N NO 3 1 9 7 4 14 A1 + OIL 11 21 D A2-2 8 OM OM 6 Graph 1 Electrical life, ops x 10 00 1000 100 ontacts Materials: Standard, Optional, code 1 Optional, code 2 Max. switching current Max. Peak inrush current ( ms.) Max. Switching voltage Max. A load (Graph 1)* oils (Ohms ± 10% @ º) Pull-in voltage Drop-out voltage Nominal coil power VD Ω ma 110 2 742 3.00 19.900 3.0 32.0 13.7. AgNi AgNi + 0.2µ Au AgNi +.0µ Au 6 A 30 A 20 V 1.A See Graph 2* < 0.8 x Un 0.1 x Un 0.7 W (D) < Graph 2 Insulation Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts & coil Isolation resistance at 00VD Isolation, IE 61810- : 2.000 V > 3GΩ 4 KV / 3 Vdc Operate Time + Bounce Time Release Time + Bounce Time Ambient Temperature Mechanical life ops. Electrical life at nominal load Operating frequency at nominal load Protection degree 10 ms. 8 ms. -40º (no ice). +70º 10 Million A, Million D relays > 100,000 ops. 1,0 / hour IP40 / RT1 21 gms. Standard types 13 Max. 7. 7 1 D :,,, 110 F = Mechanical Flag Indicator W = Free-Wheeling Diodes -FW. VD 8 2 36 9 3 29 Max 0. 2. A1 A2 4 9 Suitable Sockets : S2D, S2LD, S2P
-A Two Pole, Normally Open ontact 6A 20V A1 0.8A 110V D1 6A 30V D1 0.4A 2V D1 NO NO 1 7 4 14 A1 + OIL 11 21 A2-2 8 OM OM ontacts Materials: Standard, Optional, code 1 Optional, code 2 Max. switching current Max. Peak inrush current ( ms.) Max. Switching voltage Max. A load (Table 1) AgNi AgNi + 0.2µ Au AgNi +.0µ Au 6 A 1 A 20 V 1.A See Table 3 Graph 1 6 Electrical life, ops x 10 oils (Ohms ± 10% @ º) Pull-in voltage Drop-out voltage Nominal coil power < 0.8 x Un 0.1 x Un 1.1 VA (A) / 0.7 W (D) < 00 1000 100 VA Ω ma VD Ω ma 11 230 290 1.0 7.300 28.800 4.0 23.0 9. 4.7 110 2 742 3.00 19.900 3.0 32.0 13.7. Graph 3 Insulation Dielectric strength (1 minute): Open contacts Between adjacent poles Between contacts & coil Isolation resistance at 00VD Isolation, IE 61810- : 1.000 V 3.000 V > 3GΩ 4 KV / 3 Vdc Operate Time + Bounce Time Release Time + Bounce Time Ambient Temperature Mechanical life ops. Electrical life at nominal load Operating frequency at nominal load Protection degree 10 ms. 8 ms. -40º (no ice). +70º 10 Million A, Million D relays > 100,000 ops. 1,0 / hour IP40 / RT1 21 gms. 36 13 Max. 7. 7 1 A1 A2 4 9 29 Max Standard types A 0 Hz :,, 11, 230 F = Mechanical Flag Indicator P = LED R = R, (Snubber ircuit) D:,,, 110 F = Mechanical Flag Indicator P = LED W = Free-Wheeling Diodes Z = Polarity & Free-Wheeling Diodes B = A/D Bridge Rectifier (/V) -A-F -A-FP -A-FPR -A-F -A-FP -A-FPW -A-FPZ -A-FPB Suitable Sockets : S2D-A, S2LD-A, S2P. VA. VA. VA. VD. VD. VD. VAD. VAD 0. 2.
...M MAGNETI BLOW OUT Two Pole, hange-over ontact 6A 20V A1 1.2A 2V D1 6A 30V D1 0.30A 2V D13 A1 + A2 - ontacts Materials: Standard Max. switching current Max. Peak inrush current ( ms.) Max. Switching voltage Max. A load (Graph 1)* AgNi 6 A 30 A 20 V 1.A See Graph 4* Graph 1 6 Electrical life, ops x 10 00 1000 100 oils (Ohms ± 10% @ º) Pull-in voltage Drop-out voltage Nominal coil power VA Ω ma VD Ω ma 11 230 290 1.0 7.300 28.800 4.0 23.0 9. 4.7 110 < 0.8 x Un 0.1 x Un 1.1 VA (A) / 0.7 W (D) 2 742 3.00 19.900 < 3.0 32.0 13.7. Graph 4 Insulation D1 D13 Dielectric strength (1 minute): Open ontacts Between Adjacent Poles Between ontacts & oil Insolation resistance at 00VD Isolation, IE 61810-: 1 KV 3 KV >3GΩ 4 KV / 3 Vdc Operate Time + Bounce Time Release Time + Bounce Time Ambient Temperature Mechanical life ops. Electrical life at nominal load Operating frequency at nominal load Protection grade 10 ms. 8 ms. -40º (no ice). +70º 10 Million A, Million D relays > 100,000 ops. 1,0 / hour IP40 / RT1 21 gms. Standard types 0. 2. 36 13 Max. 7. 7 1 A1 A2 4 9 29 Max A :,, 11, 230 M = Magnetic Blow Out F = Mechanical Flag Indicator -FM. VA P = LED -FPM. VA D :,,, 110 F = Mechanical Flag Indicator -FM. VD P = LED -FPM. VD W = Free Wheeling Diode -FPWM. VD Z = Polarity & Free Wheeling Diode -FPZM. VD Suitable Sockets : S2D, S2LD, S2P
-A...M MAGNETI BLOW OUT Two Pole, Normally Open ontact 6A 20V A1 4A 2V D1 6A 30V D1 1A 2V D13 ontacts A1 + A2 - Materials: Standard Optional, code 1 Optional, code 2 Max. switching current Max. Peak inrush current ( ms.) Max. Switching voltage Max. A load (Graph 1)* AgNi AgNi + Au 0.2µ AgNi + Au.0µ 6 A 1 A 20 V 1.A See Graph * Graph 1 6 Electrical life, ops x 10 oils (Ohms ± 10% @ º) Pull-in voltage Drop-out voltage Nominal coil power < 0.8 x Un 0.1 x Un 1.1 VA (A) / 0.7 W (D) < 00 1000 100 VA Ω ma VD Ω ma 11 230 290 1.0 7.300 28.800 4.0 23.0 9. 4.7 110 2 742 3.00 19.900 3.0 32.0 13.7. Graph Insulation D1 D13 Dielectric strength (1 minute): Open ontacts Between Adjacent Poles Between ontacts & oil Insolation resistance at 00VD Isolation, IE 61810-: 1 KV 3 KV >3GΩ 4 KV / 3 Vdc Operate Time + Bounce Time Release Time + Bounce Time Ambient Temperature Mechanical life ops. Electrical life at nominal load Operating frequency at nominal load Protection grade 10 ms. 8 ms. -40º (no ice). +70º 10 Million A, Million D relays > 100,000 ops. 1,0 / hour IP40 / RT1 21 gms. Standard types 36 13 Max. 7. 7 1 A1 A2 4 29 Max A :,, 11, 230 M = Magnetic Blow Out F = Mechanical Flag Indicator -A-FM. VA P = LED -A-FPM. VA D :,,, 110 F = Mechanical Flag Indicator -A-FM. VD P = LED -A-FPM. VD W = Free Wheeling Diode -A-FPWM. VD Z = Polarity & Free Wheeling Diode -A-FPZM. VD Suitable Sockets : S2D-A, S2LD-A, S2P 0. 2. 9
-A-FW-M() MAGNETI BLOW OUT Two Pole, Normally Open ontact 6A 20V A1 ( L/R ratio:7msecs ) A 2V D13 ontacts A1 + A2 - Materials: Standard Optional, code 1 Optional, code 2 Max. switching current Max. Peak inrush current ( ms.) Max. Switching voltage Max. A load (Graph 1)* AgNi AgNi + Au 0.2µ AgNi + Au.0µ 6 A 1 A 20 V 1.A See Graph * Graph 1 6 Electrical life, ops x 10 oils (Ohms ± 10% @ º) Pull-in voltage Drop-out voltage Nominal coil power < 0.8 x Un 0.1 x Un 1.1 VA (A) / 0.7 W (D) < VD Ω ma 110 2 742 3.00 19.900 3.0 32.0 13.7. 00 1000 100 Graph Insulation D1 D13 Dielectric strength (1 minute): Open ontacts Between Adjacent Poles Between ontacts & oil Insolation resistance at 00VD Isolation, IE 61810-: 2 KV >3GΩ 4 KV / 3 Vdc Operate Time + Bounce Time Release Time + Bounce Time Ambient Temperature Mechanical life ops. Electrical life at nominal load Operating frequency at nominal load Protection grade 10 ms. 8 ms. -40º (no ice). +70º 10 Million A, Million D relays > 100,000 ops. 1,0 / hour IP40 / RT1 21 gms. Standard types 13 Max. 7. 7 1 D :,,, 110 M = Magnetic Blow Out F = Mechanical Flag Indicator -A-FM. VD P = LED -A-FPM. VD W = Free Wheeling Diode -A-FWM. VD 36 29 Max A1 A2 4 Suitable Sockets : S2D-A, S2LD-A, S2P 0. 2. 8.9
...H HEAVY RATING RELAY Two Pole, hange-over ontact 8A 20V A1 0.A 110V D1 8A 30V D1 0.2A 2V D1 A1 + A2 - ontacts Materials: Standard Optional, code 1 Optional, code 2 Max. Switching current Max. Peak inrush current ( ms.) Max. Switching voltage Max. A load ( Graph 6) * AgNi AgNi + Au 0.2µ AgNi + Au.0µ 8 A 30 A 20 V 2.0 KVA See Graph 7* Graph 6 Graph 7 Vdc 6 Electrical life, ops x 10 00 1000 100 00 oils (Ohms ± 10% @ º) Pull-in voltage Drop-out voltage Nominal coil power VA Ω ma VD Ω ma 11 230 Insulation 290 1.0 7.300 28.800 Dielectric strength (1 minute): Open contacts Between Adjacent poles Between contacts & oil Insolation resistance at 00VD Isolation, IE 61810-: 4.0 23.0 9. 4.7 110 Operate Time + Bounce Time Release Time + Bounce Time Ambient Temperature Mechanical life ops. Electrical life at nominal load Operating frequency at nominal load Protection grade < 0.8 x Un 0.1 x Un 1.1 VA (A) / 0.7 W (D) 2 742 3.00 19.900 3.0 32.0 13.7. 1.000 V 3.000 V >3GΩ 4 KV / 3 10 ms. 8 ms. -40º (no ice). +70º 10 Million A, Million D relays < > 100,000 ops. 1,0 / hour IP40 / RT1 21 gms. 0. 36 2. 13 Max. 7. 7 1 A1 A2 4 9 29 Max Standard types A :,, 11, 230 F = Mechanical Flag Indicator -FH. VA P = LED -FPH. VA I = Lockable & Manual Push Button -FPIH. VA R = R Snubber circuit (11 or 230V) -FPIRH. VA D :,,, 110 F = Mechanical Flag Indicator -FH. VD P = LED -FPH. VD W = Free Wheeling Diode -FPWH. VD Z = Polarity & Free Wheeling Diode -FPZH. VD I = Lockable & Manual Push Button -FPZIH. VD B = A/D Bridge Rectifier (/V) -FPIBH. VD Suitable Sockets : S2D, S2LD, S2P
-A...H HEAVY RATING RELAY Two Pole, hange-over ontact 8A 20V A1 1.0A 110V D1 8A 30V D1 0.A 2V D1 ontacts A1 + A2 - Materials: Standard Optional, code 1 Optional, code 2 Max. Switching current Max. Peak inrush current ( ms.) Max. Switching voltage Max. A load ( Graph 6) * AgNi AgNi + Au 0.2µ AgNi + Au.0µ 8 A 30 A 20 V 2.0 KVA See Graph 8* Graph 6 6 Electrical life, ops x 10 oils (Ohms ± 10% @ º) Pull-in voltage Drop-out voltage Nominal coil power < 0.8 x Un 0.1 x Un 1.1 VA (A) / 0.7 W (D) < 00 1000 100 00 VA Ω ma VD Ω ma 11 230 290 1.0 7.300 28.800 4.0 23.0 9. 4.7 110 2 742 3.00 19.900 3.0 32.0 13.7. Graph 8 Insulation D1 Dielectric strength (1 minute): Open contacts Between Adjacent poles Between contacts & oil Insolation resistance at 00VD Isolation, IE 61810-: 1.000 V 3.000 V >3GΩ 4 KV / 3 Vdc Operate Time + Bounce Time Release Time + Bounce Time Ambient Temperature Mechanical life ops. Electrical life at nominal load Operating frequency at nominal load Protection grade 10 ms. 8 ms. -40º (no ice). +70º 10 Million A, Million D relays > 100,000 ops. 1,0 / hour IP40 / RT1 21 gms. 0. 2. 36 13 Max. 7. 7 1 A1 A2 4 9 29 Max Standard types A :,, 11, 230 H = Heavy Duty s F = Mechanical Flag Indicator -A-FH. VA P = LED -A-FPH. VA I = Lockable & Manual Push Button -A-FPIH. VA R = R Snubber circuit (11 or 230V) -A-FPIRH. VA D :,,, 110 F = Mechanical Flag Indicator -A-FH. VD P = LED -A-FPH. VD W =Free Wheeling Diode -A-FPWH. VD Z = Polarity & Free Wheeling Diode -A-FPZH. VD B = A/D Bridge Rectifier (/V) -A-FPBH. VAD Suitable Sockets : S2D-A, S2LD-A, S2P
Input / Output Socket (6A / 8A) for O s DIN Rail or Panel Mountable Wiring Diagram Poles Nominal load : 2 hange Over ontact 6A / 8A @ 20V Ø6 Insulation: Di- electric strength, 1munitu Between contact and coil Between all terminals and DIN Rail Between adjacent terminals Brass Tin Plated Screw Max. Screw torque Screw dimensions Wire in-lets capacity: Solid wire Multi core Ferrule tip terminals 3 KV 1.2 Nm M3, Pozi 2 2 4 mm or 2 x 2.2 mm 14 AWG 2 4 mm 38 gms. 68 1 Max. 28 2.1 Ø2. 40 3 Ø3. 73 DIN Rail / Panel Mountable Integrated Hold Down lip Removable White Marking Label EN / DIN Sequential Numbering according to EN 60947 & IE 61810 84 Max. Accessories Bridge Bar S2D-B1 & S2D-B4 for oil Terminal (A2 / )
S2D-A Input / Output Socket (6A / 8A) for NO s DIN Rail or Panel Mountable Wiring Diagram Poles Nominal load : 2 Normally Open ontact 6A / 8A @ 20V Ø6 Insulation: Di- electric strength, 1munitu Between contact and coil Between all terminals and DIN Rail Between adjacent terminals Brass Tin Plated Screw Max. Screw torque Screw dimensions Wire in-lets capacity: Solid wire Multi core Ferrule tip terminals 3 KV 1.2 Nm M3, Pozi 2 2 4 mm or 2 x 2.2 mm 14 AWG 2 4 mm 38 gms. 68 28 2.1 Ø2. 40 36 Ø3. 73 DIN Rail / Panel Mountable Integrated Hold Down lip Removable White Marking Label EN / DIN Sequential Numbering according to EN 60947 & IE 61810 1 Max. 84 Max. Accessories Bridge Bar S2D-B1 & S2D-B4 for oil Terminal (A2 / )
S2LD Input / Output Socket (6A / 8A) for O s DIN Rail or Panel Mountable 16mm Wiring Diagram Poles Nominal load : 2 hange Over ontact 6A / 8A @ 20V Insulation: Di- electric strength, 1munitu Between contact and coil Between all terminals and DIN Rail Between adjacent terminals Brass Tin Plated Screw Max. Screw torque Screw dimensions Wire in-lets capacity: Solid wire Multi core Ferrule tip terminals 3 KV 1.2 Nm M3, Pozi 2 2 4 mm or 2 x 2.2 mm 14 AWG 2 4 mm 38 gms. DIN Rail / Panel Mountable Integrated Hold Down lip Removable White Marking Label EN / DIN Sequential Numbering according to EN 60947 & IE 61810 16 Max. 21 S2-LD A2 11 14 A1 9 8 7 3 2 1 4 13 49 13 23 21 3 41 2 78 Max. Accessories Accessories S2LD-B1-1 Way Bridge Fork / - Terminal for wire connection S2LD-B1 Terminal.10 7. 6.4 (± 0.) 3.7(-0 /+0.2).3 8 4 21 ( ±1.0) 2 6. 10 ( ± 0.0 ) S2LD-B1 1 Way Bridge for oil Ø 1.7 (±0.) Ø 4.0 (±0.30) Fork / type crimped Terminal used for wire connection
S2LD-A Input / Output Socket (6A / 8A) for NO s DIN Rail or Panel Mountable 16mm 49 16.0 Max. 21 11 14 S2-LD 13 23 A2 A1 8 7 2 1 4 Wiring Diagram Poles Nominal load : 2 Normally Open ontact 6A / 8A @ 20V 13 Insulation: Di- electric strength, 1munitu Between contact and coil Between all terminals and DIN Rail Between adjacent terminals Brass Tin Plated Screw Max. Screw torque Screw dimensions Wire in-lets capacity: Solid wire Multi core Ferrule tip terminals 3 KV 1.2 Nm M3, Pozi 2 2 4 mm or 2 x 2.2 mm 14 AWG 2 4 mm 38 gms.. 3 40. 2 DIN Rail / Panel Mountable Integrated Hold Down lip Removable White Marking Label EN / DIN Sequential Numbering according to EN 60947 & IE 61810 78 Accessories Accessories S2LD-B1-1 Way Bridge Fork / - Terminal for wire connection S2LD-B1 Terminal.10 7. 6.4 (± 0.) 3.7(-0 /+0.2).3 8 4 21 ( ±1.0) 2 6. 10 ( ± 0.0 ) S2LD-B1 1 Way Bridge for oil Ø 1.7 (±0.) Ø 4.0 (±0.30) Fork / type crimped Terminal used for wire connection
S2-P Printed ircuit Socket (6A / 8A) for s 1 Nominal load Dielectric strength 1 min. oil terminals to contacts Hard brass tin-plated terminals Integrated hold down clip 6A / BA @20V 0.3 x 1mm 6 gms. Ordering Information lassification General Purpose LED Indicator & Flag Indicator LED Indicator with Flag Indicator, Free Wheeling & Polarity Diode LED Indicator with Flag Indicator, Free Wheeling & Polarity Diode, Lockable & Manual Push Button oil Ratings A / D D Standard Types - DPDT (2/O) -F -FP -FPZ -FPZI 1 2 3 4 6 1 : Type Blank : General Purpose / Standard 2 : ontact Form Blank : DPDT (2 /O) A : DPST-NO(2 N/O) 3 : ontact Type Blank : Single Example : -FPZI-1-VD 4 : Features Blank : No features / Standard F : Mechanical Operation Indicator P : LED Indicator Z : Free Wheeling + Polarity Diode I : Lockable + Manual Push Button B : Bridge rectifier R : R/ (Snubber ircuit) M : Magnetic Blow Out H : Heavy Duty W: Free Wheeling Diode : ontact Material Blank : AgNi 1 : AgNi + Au 0. 3µ 2 : AgNi + Au.0µ 6 : Rated oil Voltage 6 / / / / 110 - VD 6 / / / 11 / 230 - VA means Standard, DPDT (2 /O ontact), with Mechanical Operation Indicator, with LED Indicator, with Free Wheeling and Polarity Diode, with Lockable and Manual Push Button, with AgNi ontacts and 0.2µ Gold Flash with VD oil
S2D is the World s most compact ( 1mm width) DIN Rail Mountable Socket for the relays with the below Pitch & Pin configuration Ø6 68 73 1 Max. 84 Max. 28 2.1 Ø2. 40 3 Ø3. 1mm width of the S2D DIN Rail Mountable Socket allows to mount 64 Sockets on a Standard 3 mm Din Rail with a length of 1 meter / 1000 mm length ( with a provision for Nos. of End stoppers each with a width of 8 mm). Generally the PL (Programmable Logic ontroller) / DS (Distributed ontrol System) output is 64 Bit output which requires 64 s to drive the load. All the 64 s driven by a particular PL / DS can be mounted on a single 3 mm standard 1 Mt / 1000 mm Din Rail. The provision to mount 64 s on a single 3 mm DIN Rail with 1 mt / 1000 length makes the wiring, identification of the relays from a particular PL / DS & maintenance very easy and convenient. Mounting Tracks All in mm 7
Schematic diagram showing typical mounting of 64 s & Sockets on a standard 3 mm Din Rail with 1 meter (1000 mm) length 1mm ( per socket ) x 16 nos = 0mm 1mm ( per socket ) x 16 nos = 0mm 1mm ( per socket ) x 16 nos = 0mm 1mm ( per socket ) x 16 nos = 0mm 8mm 8mm 8mm 8mm 8mm Socket 1 1 mm max. Socket 2 1 mm max....... Socket 16 1mm max. Socket 17 1 mm max. Socket 18 1 mm max....... Socket 32 1 mm max. Socket 33 Socket 34 1 mm max. 1 mm max....... Socket 1 mm max. Socket 49 1 mm max. Socket 0 1 mm max....... Socket 64 1 mm max. 14 14 14 14 14 14 14 14 14 14 14 14 7 1 7 1 7 1 7 1 7 1 7 1 7 1 7 1 7 1 7 1 7 1 7 1 4 4 DIN Rail White Label 4 4 4 4 4 4 4 4 4 4 nos. End Stopper (max. Width 8mm) ommon S2D-B1 / S2D-B4 oil Bridge S2 D Socket S2 D sockets can be interconnected through bridge bars in the coil line at the points A2 by using S2D-B1 and S2D-B4 oil Bridges
Paramount Industries #70, th ross, SSI Area, Rajajinagar, Bangalore - 60 010, India. Tel : +91-80-970010, 2317313, 2310828 Fax : +91-80-2330274, 28623 Email : info@paramount.net.in Website : www.paramount.net.in Specification may change in the view of product improvement without prior intimation.