Insulated Roof & Wall Panels. Product Data Sheet. Roof Tile Effect Insulated Panel KS1000 RT

Similar documents
Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

ALUMINIUM. Product Data Sheet

Longspan. Insulated Panels. Architectural Frame to Frame Insulated Panel System. CI/SfB (4-) Rh2 September 2008

Kingspan Roof Tile. Insulated Panels. Insulated Tile Effect Roofing System. Building to the Power of. CI/SfB. September 2008

Kingspan Envirodek Structural Green Roof System

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

Building to the Power of

Composite Panel Firewall Systems

Upstand Rooflight Natural Light Translucent Upstand Systems

Master Panel 1000 R5 Roof

Master Panel 1000 W Wall

Colours from Kingspan

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

All Weather Hall. Efficient, multipurpose & quick to build

PROFILED METAL ROOFING DESIGN GUIDE

Rockwool Flexi Insulation Application Guide

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

INSTALLATION. General. Important Note. Design. Transport

Installation Detailed installation instructions are provided which should be strictly followed.

Low Energy Low Carbon Buildings

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

PART 1 GENERAL 1.1 SECTION INCLUDES

FIREPROOF Panels Trimoterm

Low Energy Low Carbon Buildings

How To Certify The Scottsdale Construction System

The Kingspan Insulation Price List 1 st January 2013

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Architectural composite panels

Corus Panels and Profiles. Roof and Wall Composite Panels

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Energy Company Obligation (ECO): Technical Monitoring Questions

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Series 456 Commercial Awning Window

Asphalt Shingle Application Requirements

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

How To Make An Oriented Strand Board

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

Initial Type Testing Report

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Mineral fibreglass insulation

Smooth & Seamless Hygienic Doors for the Food Sector

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

technology UICK progressive sustainable any design, any shape, any colour, anywhere you like!

ProRox Slabs (formerly known as RW slabs)

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings

ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

Cable Trays Technical Instructions & Specifications

December J-Ply Roofing, Flooring and Decking

BETONYP building boards. The modern way of living.

Timber Decks. Technical Note. March 2007

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Rockwool Cladding Roll

Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility

CDW Systems Ltd Contemporary Doors & Windows

Fire Safety Requirements for Child Care Centre

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Dubai Municipality Standard DMS 1: Part 5: 2004

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Module 3.7. Thermal bridging

HDA

Confort 160. Sliding Systems. Sapa Building System

POST AND FRAME STRUCTURES (Pole Barns)

TechPractices: Home Front Homes:

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Quality Regulations for Profiles


The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

DELTA SYSTEMS DELTA. The company, products and the service. in 150 mm to 600 mm modules are formed on a

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

B. Related categories: The following categories contain requirements that relate to this section:

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Approved Document Q: Security

Prefabricated building PVC vertical sliding window

Multi-layer Insulation Blanket for Roofs

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

COMMONLY USED RESIDENTIAL BUILDING CODES

sound reduction systems for commercial, educational and industrial environments

Unbeatable energy efficient glass curtain wall system

Passive Fire Protection

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Transcription:

Insulated Roof & Wall Panels Effect Insulated Panel KS1000 RT

Applications KS1000 RT looks like a traditional tiled roof but it is a modern Kingspan insulated panel with a shaped exterior that performs better than any tiling system. The insulation is built-in and can be used for any domestic or commercial building with a roof pitch of 12 or more after deflection. The traditional look hides a sophisticated system that is easy to construct and complies with all contemporary building standards. Available Lengths Standard Lengths 2.1 11.5m Longer Lengths (non-standard) 11.5 15.7m Shorter Lengths (non-standard) Below 2.1m Note: Panel lengths are based on tile module of 325mm plus 150mm for cutbacks of 160mm or 100mm for 100mm cutbacks. Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK). 1000mm cover width Core Thickness Dimensions, Weight & Thermal Performance Core Thickness (mm) 45 60 80 100 Overall Thickness (mm) 85 100 120 140 U-value (W/m²K) 0.45 0.32 0.25 0.20 Weight kg/m² 0.5/0.4 Steel 10.7 11.3 12.2 13.1 The KS1000 RT insulated roof panels have a Thermal Transmittance (U value), calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Section 6 (Scotland). 1

Insulation Core KS1000 RT insulated roof panels are manufactured with an ECOsafe and FIREsafe polyisocyanurate (PIR) core. Fire The external and internal faces of the panel to be Class 0 in accordance with the Building Regulations when tested to BS 476: Part 6: 2009 and Part 7: 1997. The panel is rated SAA when tested to BS 476: Part 3: 2004. This FIREsafe system has passed all the requirements of LPS 1181: 2005: Part 1: Issue 1.1, ceiling lining tests by the Loss Prevention Certification Board (LPCB) certified to LPS 1181 Grade EXT B. Biological Kingspan panels are normally immune to attack from mould, fungi, mildew and vermin. No urea formaldehyde is used in the construction, and the panels are not considered deleterious. Materials Substrate Kingspan XL Forté, Kingspan AQUAsafe, and Kingspan CLEANsafe: Material S220GD+ZA hot-dip zinc/aluminium Galfan coated steel to BS EN 10346: 2009 Standard external sheet thickness 0.5mm, standard internal sheet thickness 0.4mm. Polyurethane & Bright White Polyester: Hot dip zinc coated to BS EN 10346: 2009, Standard internal steel thickness 0.4mm, Stucco embossed. Coatings - External Weather Sheet Environmental This ECOsafe system may achieve a Green Guide A+ rating and is subject to project specific assessments. Air Leakage An air leakage rate of 3m 3 /hr/m 2 at 50Pa or less can be achieved when using Kingspan insulated roof and wall panels. Acoustic Sound Reduction Index (SRI) Hz* 63 125 250 500 1K 2K 4K 8K SRI (db) 20 19 21 22 22 32 38 44 * Frequency The KS1000 RT insulated roof panel has a single figure weighted sound reduction Rw = 25dB. Kingspan XL Forté: Consists of a multi-layer organic coating, embossed with a traditional leather-grain finish. Polyurethane Coating: High performance polymer coating applied to the weather side of the panel. Designed to achieve excellent endurance characteristics. Coatings - Internal Liner Sheet Bright White Polyester: The coating has been developed for use as the internal lining of insulated panels. Standard colour is bright white with an easily cleaned surface. Kingspan AQUAsafe: The coating has been developed for use as the internal lining of insulated panels to suit high humidity internal environments (class 5 as defined by the Building Regulations). Kingspan CLEANsafe: The coating has been developed for use as the internal lining of insulated panels where a high level of cleanliness and hygiene is required, and the panels are to be cleaned down on a regular basis. 2

Panel End Cut Back Standard Cut Back Cut Back for up to 6.275m lengths 160mm 100mm Note: We do not recommend end lapping KS1000 RT panels. Tolerance Cut to Length -0.05% +0.1% Liner Sheet Length -0.1% +0.1% Cover Width Thickness End Square Handing -0mm +3mm -2mm +2mm -3mm +3mm The KS1000 RT insulated roof panel can be manufactured in left to right handed (LH) only. Quality & Durability KS1000 RT insulated roof panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with BS EN ISO 9001 standard, ensuring long term reliability and service life. The panels are also being manufactured under Environmental Management System Certification BS EN ISO 14001. Compliant to BS OHSAS 18001 Occupational Health and Safety. Guarantee Kingspan Total Panel Guarantee covering the structural and thermal performance for a period of up to 25 years and Kingspan Coating Guarantee for a period of up to 40 years (subject to project specific information). Packing KS1000 RT insulated roof panels are stacked weather sheet to weather sheet (to minimise pack height). The top, bottom, sides and ends are protected with foam and timber packing and the entire pack is wrapped in plastic. Core Thickness (mm) No. of panels in Pack 45 60 80 100 10 8 8 6 Note: Applies to UK pack sizes. Please contact Kingspan Technical Services for export information. Quantities are reduced for exceptionally long panels. Sea Freight Fully timber crated packs are available on projects requiring delivery by sea freight shipping, at additional costs. Alternatively, steel containers can be used. Special loading charges apply. Delivery All deliveries (unless indicated otherwise) are by road transport to project site. Off-loading is the responsibility of the client. Site Installation Procedure Site assembly instructions are available from Kingspan envirocare Technical Services. 3

Data Structural Tables Unfactured load/span table (use unfactored calculated design wind load values). Outer Sheet 0.5mm (Steel), Inner Sheet 0.4mm (Steel) Single Span Condition Panel Thickness (mm) 45 60 80 100 Double Span Condition Panel Thickness (mm) 45 60 80 100 Uniformly distributed loads kn/m² Load Types Span L in metres 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Downwards 4.33 2.92 1.98 1.37 0.96 0.69 - - - - - Suction 4.47 3.12 2.31 1.78 1.42 1.16 - - - - - Downwards 5.34 3.68 2.68 2.00 1.45 1.06 0.79 0.58 - - - Suction 5.49 3.83 2.83 2.18 1.74 1.42 1.19 1.01 - - - Downwards 6.68 4.61 2.36 2.55 1.99 1.59 1.30 1.01 0.77 0.60 - Suction 6.86 4.79 3.54 2.73 2.17 1.77 1.48 1.25 1.08 0.94 - Downwards 8.03 5.54 4.04 3.07 2.40 1.92 1.57 1.30 1.09 0.93 0.79 Suction 8.22 5.74 4.24 3.26 2.60 2.12 1.77 1.50 1.29 1.12 0.99 Uniformly distributed loads kn/m² Load Types Span L in metres 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Downwards 4.33 2.98 2.17 1.64 1.28 1.02 0.83 0.68 0.57 - - Suction 4.47 3.12 2.31 1.78 1.42 1.16 0.97 0.83 0.71 - - Downwards 5.34 3.68 2.68 2.03 1.59 1.27 1.03 0.85 0.72 - - Suction 5.49 3.83 2.83 2.18 1.74 1.42 1.19 1.01 0.87 - - Downwards 6.68 4.61 3.36 2.55 1.99 1.59 1.30 1.07 0.90 0.76 0.65 Suction 6.86 4.79 3.54 2.73 2.17 1.77 1.48 1.25 1.08 0.94 0.83 Downwards 8.03 5.54 4.04 3.07 2.40 1.92 1.57 1.30 1.09 0.93 0.79 Suction 8.22 5.74 4.24 3.26 2.60 2.12 1.77 1.50 1.29 1.12 0.99 Notes: 1. Values have been calculated using the method described in BS EN 14509: 2013, for medium and light coloured panels. 2. Deflection limit for: downward loading is L/200 and suction loading is L/150. 3. The actual wind suction load resisted by the panel is dependent on the number of fasteners used and the purlin thickness as well as the fastener material. 4. The fastener calculation should be carried out in accordance with the appropriate standards. For further advice please contact Kingspan envirocare Technical Services. 5. The allowable steelwork tolerance between bearing planes of adjacent supports is +/- 5mm. 6. Load span tables for the panel specifications not shown are available from Kingspan envirocare Technical Services. 4

Data Kingspan Limited Greenfield Business Park No.2, Greenfield, Holywell, Flintshire, North Wales CH8 7GJ t: +44 (0) 1352 716100 f: +44 (0) 1352 710161 www.kingspanpanels.com Registered Office at Greenfield Business Park No.2, Greenfield, Holywell, Flintshire, N. Wales CH8 7GJ. Company Reg. No. 1037468 5