eurammon Symposium 2015 Ecodesign Regulations for Liquid Chillers for Hermann Renz, BITZER GmbH

Similar documents
WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS

Ecodesign Directive 2009/125/EC & Energy Labelling Directive 2010/30/EU State of Play. Eurovent General Assembly

Technical comments on the proposal on Eco-design and Energy label requirements for boilers ENER Lot 1 June 2011

Appendix C. Minimum Equipment Efficiency Standards

REFRIGERATOR AND AIR-CONDITIONER TESTING IN THE REPUBLIC OF KOREA

New energy evaluating methodology of Air conditioner and Heat pump

EcoDesign & Labelling Directive (ErP)

The new Ecodesign regulation for heaters: what does it mean for heat pumps?

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

European actions to improve the energy efficiency of buildings. Olli Seppänen, professor Federation of European Heating and Airconditioning

Energy efficient room air conditioners best available technology (BAT)

Air-cooled Chillers with High Speed Centrifugal Compressors

INFO. Legally binding regulations on relating to energy efficiency and environmental protection. Eco-Design Directive and EC-Commission Regulation

LG Electronics AE Company, Commercial Air Conditioning

News in Data Center Cooling

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

Heating & Cooling Efficiency

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

HVAC Efficiency Definitions

Shaping the future. For room air conditioners of up to 12 kw (Lot 10) Information brochure for specialists, decision-makers and operators

DIABLO VALLEY COLLEGE CATALOG

ENERGY STAR Central Air Conditioners & Air-Source Heat Pumps

Air conditioning systems Final report of Task 6

OJ L 191, , p. 26. OJ L 2, , p. 1.

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

APPLICATIONS AND DEFINITIONS

Cooling kw Heating kw

Chapter 3.4: HVAC & Refrigeration System

2015 C&I HVAC RETROFIT APPLICATION FOR PRESCRIPTIVE REBATES

Percent per Degree Rule of Thumb for Refrigeration Cycle Improvement

Simulation of a small size solar assisted adsorption air conditioning system for residential applications

HVAC Basic Science - System Capacity

An overview of energy efficient products used at reducing energy consumptions in buildings

The Mean Green Cooling MachineTM

Natural geothermal energy.

Elements of Energy Efficiency in Data Centre Cooling Architecture

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Technical aspects of ErP for boilers and water heaters, Ecopliant Workshop for MSAs

Time to Rethink Heating

Regency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July Prepared by

Test Report issued under the responsibility of:

Heating, Ventilation & Air Conditioning Equipment

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Energy Efficiency in HVAC equipment applications

Eurovent Certification

HVAC, Motors, VFD, Compressed Air, Refrigeration, MISC, Custom

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

Heating, Ventilation & Air Conditioning Equipment

Commercial Gas Heat Pump - VRF

New technical solutions for energy efficient buildings

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Silicagel-water adsorption cooling prototype system for mobile air conditioning

Building Energy Systems. - HVAC: Heating, Distribution -

Non-Domestic Building Services Compliance Guide

Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015

Rules of Thumb Energy Efficiency in Buildings

Evaluation of Pump and Air Pumps

Glossary of Heating, Ventilation and Air Conditioning Terms

Energy Depot for Business Energy Audit Question Set

Daikin Altherma. hybrid heat pump. The natural combination

How to Build a Data Centre Cooling Budget. Ian Cathcart

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

The Seasonal Efficiency of Multi-Boiler and Multi-Chiller Installations

Setting the Scene. Fuelling the Future, Heat Pumps and more. What are the Drivers? Have we reached Peak Oil? Heating Technologies.

Consumers Energy Business Solutions. Commercial and Industrial Energy Efficiency Program April 18, 2013

SOLAR-POWERED COOLING, DEHUMIDIFICATION AND AIR CONDITIONING

Evaporative Cooling for Residential and Light-Commercial

ROTEX Gas-Hybrid-Heat Pump

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

forair optimal air environments ResidentialPresentation

POSITION PAPER Brussels, 29 th November 2011

3/29/2012 INTRODUCTION HVAC BASICS

Testing methods applicable to refrigeration components and systems

COMMERCIAL HEATING VENTILATION & AIR CONDITIONING (HVAC)

Abstract. Efficiency potentials today

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005

Energy Efficiency Tips for Businesses

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

How to Test a Heat Pump For Risk

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

Factsheet. FAQ s regarding ErP Directives. 1) What is ErP?

Product overview Air conditioning service units

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

SMM. Installation Operation Maintenance

Inverter technology. bulletin

Your energy costs. A room-by-room guide. P.O. Box San Diego, CA Connect at sdge.com

Commercial Energy Efficiency Program. Save money, reduce energy use and earn incentives. Save money, reduce energy use and qualify for incentives

Energy Efficiency Standards and Labeling in India

Air-to-water heat pumps: Making the most of renewables. Richard Pickford, Daikin UK

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Intertek Testing Services 70 Codman Hill Road Boxborough, MA WORLD LAB

york air-conditioning products Residential & VRF News 2015

Transcription:

eurammon Symposium 2015 Ecodesign Regulations for Liquid Chillers for Hermann Renz, BITZER GmbH Hermann Renz, BITZER GmbH Schaffhausen, 25 th /26 th June, 2015

Ecodesign Regulations for Liquid Chillers Contents Main objectives of Ecodesign Framework Directive Projects within the Ecodesign Framework Directive ENTR Lot 1 / ENER Lot 21 Application ranges Mandatory requirements for placing on the market Load and temperature profiles Calculation method Efficiency requirements MEPS Summary Schaffhausen, 25 th / 26 th June, 2015 Page 2

Ecodesign Framework Directive 2009/125/EC The four main objectives Ensure the free movement of energy-related products within the EU Improve the overall environmental performance of these products and thereby protect the environment, Contribute to the security of energy supply and enhance the competitiveness of the EU economy, Preserve the interests of industry, consumers, and other stakeholders Schaffhausen, 25 th / 26 th June, 2015 Page 3

Projects (Lots) within the Ecodesign Framework Directive 2009/125/EC Commissions Energy (ENER) and Enterprise (ENTR) ENER Lot. ENTR Lot. 1. Boilers 10. Air cond. < 12 kw 20. Local room heating 1. Refrigeration 2. Water heaters 11. Motors, fans,.. - under revision 21. Central heating, cooling products 2. Transformers 3. PC 12. Com. Refrigerators.. 3. Multimedia 4. Copiers 13. Domestic Refrig... 4. Industr. furnaces 5. TV, 14. Dish washers 30. Motors / Drives 5. Machine tools 6. Stand-by losses 15. Fossil fuel burner 31. Compressors 6. A/C and Ventilation HT Process Chillers Comfort A/C Chillers Air Heating Heat Pumps 7. Battery charger 16. Laundry Driers 32. Windows 7. Steam boilers 8. Office lights 17. Vacuum cleaners 8. Power cables 9. Street lights 18. Set top boxes 9. Enterprise servers MT & LT Process Chillers Condensing Units HVAC&R Involvement 19. Domestic lighting Current main work items for HVAC&R Schaffhausen, 25 th / 26 th June, 2015 Page 4

Major Projects for HVAC&R Current Major Focus ENTR Lot 1 Professional Storage Cabinets, Blast Cabinets, Condensing Units and MT/LT Process Chillers ENER Lot 21 Air Heating Products (incl. Air HP), Cooling Products (incl. A/C Chillers) and High Temp Process Chillers Both Lots are still in a draft stage Regulation acc. to Lot 1 expected for July! Further Lots of Relevance ENER Lot 1(2) (EU) No 813/2013 Space heaters and Combi Heaters ENER Lot 11 ENER Lot 12 ENER Lot 30 (EU) No 327/2011 Fans Driven by Motors Revision Commercial Refrigerators and Freezers Motors & Variable Speed Drives ENTR Lot 6 A/C and Ventilation Units (merged with ENER Lot 10) Schaffhausen, 25 th / 26 th June, 2015 Page 5

ENTR Lot 1 / ENER Lot 21 Application Ranges for Chillers (1) Process Chillers (2) Comfort A/C Chillers LT -25 C brine MT -8 C brine HT +7 C water A/C +7 C water air-cooled and water-cooled air-cooled and water-cooled air-cooled and water-cooled air-cooled and water-cooled ENTR Lot 1 ENER Lot 21 Schaffhausen, 25 th / 26 th June, 2015 Page 6

ENTR Lot 1 Process Chillers (LT / MT) Mandatory Requirements for Placing on the Market Minimum Efficiency Performance Standards MEPS Process Chillers LT / MT SEPR SEER LT (brine -25 C) Cooling capacity < 200 kw // 200 kw MT (brine -8 C) Cooling capacity < 300 kw // 300 kw t amb (A) 35 C t amb (B) 25 C t amb (C) 15 C t amb (D) 5 C Criteria for MEPS* Application of the Regulation from.. full load part load part load part load Tier-1 01.07.2016 Tier-2 01.07.2018 SEPR Seasonal Energy Performance Ratio - calculated from EER at full and part load points Schaffhausen, 25 th / 26 th June, 2015 Page 7

ENER Lot 21 Process Chillers (HT) Mandatory Requirements for Placing on the Market Minimum Efficiency Performance Standards MEPS Process Chillers SEPR h s,c (SEER) HT (water 7 C) Cooling capacity < 400 kw // 400 kw // 1500 kw (water-cooled condenser) t amb (A) 35 C t amb (B) 25 C or 30 C t amb (C) 15 C or 25 C t amb (D) 5 C or 20 C Criteria for MEPS* Application of the Regulation from.. full load part load (25 ) part load (15 ) part load (5 ) Tier-1 01.01.2017?? Tier-2 01.01.2020?? or* full load part load (30 ) part load (25 ) part load (20 ) * Not yet confirmed SEPR Seasonal Energy Performance Ratio - calculated from EER at full and part load points h s,c Seasonal Space Cooling Efficiency [%] ISC 05.2015 Schaffhausen, 25 th / 26 th June, 2015 Page 8

ENER Lot 21 Comfort A/C Chillers Mandatory Requirements for Placing on the Market Minimum Efficiency Performance Standards MEPS Comfort A/C Chillers SEPR h s,c (SEER) A/C (water 7 C) Cooling capacity t amb (A) 35 C t amb (B) 30 C t amb (C) 25 C t amb (D) 20 C Criteria for MEPS* Application of the Regulation from.. < 400 kw // 400 kw // 1500 kw (water-cooled cond.) full load part load part load part load Tier-1 01.01.2017?? Tier-2 01.01.2020?? ISC 05.2015 h s,c Seasonal Space Cooling Efficiency [%] - calculated from SEER by CC (PEF) = 2.5 SEER Seasonal Energy Efficiency Ratio - calculated from EER at full and part load points Schaffhausen, 25 th / 26 th June, 2015 Page 9

Load and Temperature Profiles ENTR Lot 1 ENER Lot 21 LT Process Chillers MT Process Chillers HT Process Chillers A/C Comfort Chillers Reference Condition aircooled t amb [ C] watercooled t water [ C] load [%] Reference Condition aircooled t amb [ C] watercooled t water. [ C] load [%] A 35 30 100 B 25 23 93 C 15 16 87 D 5 9 80 A 35 30 100 B 30 26 74 C 25 22 47 D 20 18 21 Schaffhausen, 25 th / 26 th June, 2015 Page 10

Load profile [%] Liquid Chillers Load Profile vs. Ambient Temperature Ambient temperature [ C] Schaffhausen, 25 th / 26 th June, 2015 Page 11

BIN hours per year Temperature Profile Strasbourg ENTR Lot 1 Process Chillers Ambient temperature [ C] Schaffhausen, 25 th / 26 th June, 2015 Page 12

BIN BIN Stunden hours per pro year Jahr Temperature Profile ENER Lot 21* (EN 14825) for A/C Chillers vs. Temperature Profile Strasbourg Efficiency Evaluation SEPR Efficiency Evaluation h s,c (SEER) Umgebungstemperatur [ C] Ambient temperature [ C] * based on EN 14825 Schaffhausen, 25 th / 26 th June, 2015 Page 13

SEPR and SEER Calculation Method Seasonal Energy Performance Ratio Seasonal Energy Efficiency Ratio SEPR SEER EER bin SEPR, SEER = seasonal cooling demand seasonal electrical energy demand T j = BIN temperature j = BIN number with j {1,2, n} P R (Tj) = Refrigeration (cooling) demand for the corresponding BIN temperature T j h j = Number of BIN hours occurring at the corresponding BIN temperature T j COP PL (T j ) = COP values of the unit for the corresponding BIN temperature T j EER bin (T j ) = EER values of the unit for the corresponding BIN temperatur T j Schaffhausen, 25 th / 26 th June, 2015 Page 14

Cooling demand [-] Duration per bin in hours Degradation Coefficients for EER Correction Example: Process Chillers w/o Capacity Modulation 1,4 1,2 1,0 0,8 0,6 0,4 0,2 0,0 bin hours Demand D -20-15 -10-5 0 5 10 15 20 25 30 35 40 C Ambient temperature in C Capacity characteristic w/o modulation Degradation (Cd) of EER Cd B A 450 400 350 300 250 200 150 100 50 0 Schaffhausen, 25 th / 26 th June, 2015 Page 15

EER Correction: Chillers w/o Modulation Part load EER for chillers (compressors) w/o capacity modulation: Calculation according to EN 14825 Degradation Coefficient (Cd), (Cdc) at part load (CR = capacity ratio): Cdc can be determined by test (EN 14825) A/C Chillers incl. power demand of all auxiliaries during standstill (e.g. oil heater). If not to be determined by test Cdc = 0,9 Process Chillers: Due to very high running hours over the year, power demand for oil heaters is not relevant for Cdc Schaffhausen, 25 th / 26 th June, 2015 Page 16

Excel Sheet for SEPR Calculation Example: Process Chillers Temperature range for SEPR calculation from -19 C to 38 C in 1 K increments 4 Reference Conditions: 35, 25, 15, 5 C ambient Schaffhausen, 25 th / 26 th June, 2015 Page 17

ENTR Lot 1 / ENER Lot 21 Projects Efficiency Requirements for Liquid Chillers Minimum Energy Performance Standards MEPS Schaffhausen, 25 th / 26 th June, 2015 Page 18

ENTR Lot 1 / ENER Lot 21 Status Following slides are showing the current status of minimum efficiency requirements (MEPS) Process Chillers: MEPS are accepted by Commission Officials and Stakeholders and will most likely not be changed in the final Regulation Comfort A/C Chillers: Very challenging (some non-plausible) MEPS were not lowered during the current Inter-service Consultation Process despite of convincing counter proposals from Stakeholders at an earlier stage Further initiatives are taken with the target to reach a consensus with the hope that MEPS (at least for Tier-1) will be changed Schaffhausen, 25 th / 26 th June, 2015 Page 19

ENTR Lot 1 / ENER Lot 21 Liquid Chillers Proposed Minimum Energy Performance Standards MEPS Process Chillers SEPR Analysis LT air-cooled MT air-cooled HT air-cooled Cooling capacity MEPS Tier-1 MEPS Tier-2 < 200 kw 200 kw < 300 kw 300 kw < 400 kw 400 kw 1,48 1,6 2,24 2,8 4,5 5,0 1,7 1,84 2,58 3,22 5,0 5,5 LT water-cooled < 200 kw 200 kw 1,82 2,1 2,09 2,42 MT water-cooled < 300 kw 300 kw 2,86 3,8 3,29 4,37 HT water-cooled < 400 kw 400 kw 1500 kw (ISC 05.2015) 6,5 7,5 8,0 7,0 8,0 8,5 Schaffhausen, 25 th / 26 th June, 2015 Page 20

A/C Chillers Conversion of SEER to Seasonal Space Cooling Energy Efficiency h s,c 1 CC h s,c [%] = SEER [%] F (i) [%] Subject for misinterpretation to be clarified with Commission SEER 100 1 h s,c [%] =? 2,5 1,03 h s,c [%] = SEER 40 1,03 Conversion Coefficient CC = 2,5 (PEF) reflecting the estimated 40% average efficiency for generating electrical energy within the EU acc. to Directive 2012/27/EU, Annex IV Summation of Corrections F (i) = 3% accounts for the negative contribution due to adjusted contributions of temperature controls Schaffhausen, 25 th / 26 th June, 2015 Page 21

ENER Lot 21 Liquid Chillers Proposed Minimum Seasonal Space Cooling Efficiency Comfort A/C Chillers h s,c / SEER Analysis Refrigerants GWP > 150 air-cooled water-cooled Cooling capacity h s,c (SEER) Tier-1 h s,c (SEER) Tier-2 < 400 kw 400 kw < 400 kw 400 kw 1500 kw 157% (4,0) 173% (4,4) 196% (5,1) 256% (6,6) 256% (6,6)?? 161% (4,1) 185% (4,7) 200% (5,2) 272% (7,0) 272% (7,0)?? Comfort A/C Chillers h s,c / SEER Analysis Refrigerants GWP < 150 air-cooled water-cooled Cooling capacity h s,c Tier-1 h s,c Tier-2 < 400 kw 400 kw < 400 kw 400 kw 1500 kw 141% 156% 176% 230% 230%?? 145% 167% 180% 245% 245%?? ISC 05.2015 Schaffhausen, 25 th / 26 th June, 2015 Page 22

Ecodesign ENER Lot 21 A/C Chillers < 400 kw Market Influence within EU Tier-2 Tier-1 Tier-1: 2017 ~ 87% 80% Tier-2: 2019 ~ 92% 88% MEPS are not achieved by Eurovent data base 05.2015: ESEER translated into SEER net Schaffhausen, 25 th / 26 th June, 2015 Page 23

Further Requirements Process and Comfort A/C Liquid Chillers Requirements for tolerances: SEPR, h s,c (SEER), EER at Reference Conditions Comfort A/C Chillers (air-cooled) Limits for maximum sound power levels General formal requirements acc. Directive 2009/125/EU Conformity assessment acc. Article 8 (2) CE Marking including Declaration of Conformity Technical Documentation acc. Annex IV and V Information on disassembly, recycling and disposal Schaffhausen, 25 th / 26 th June, 2015 Page 24

Example: Process Chillers Data sheet for performance declaration Schaffhausen, 25 th / 26 th June, 2015 Page 25

Summary Ecodesign Regulations Liquid Chillers are setting very high Energy Efficiency requirements in future Regulations still in draft stage ENTR Lot 1 expected for July 2015 Minimum Energy Performance Standards (MEPS) will become mandatory for being allowed to place products on the EU Market Tier-1 for CU and LT / MT Process Chillers as of July 1, 2016 Liquid Chillers for Comfort A/C will in future be assessed on basis of Seasonal Space Cooling Energy Efficiency Eurovent data base shows that the majority of currently produced products must be dropped from the market Proposed MEPS from the EU Commission are overstated request from Stakeholders to set lower levels Schaffhausen, 25 th / 26 th June, 2015 Page 26

Thank You for Your Attention! Contact: Hermann Renz Eschenbruennlestr. 15, D-71065 Sindelfingen Germany +49 7031 932 240 +49 7031 932 5240 hermann.renz@bitzer.de