BA410. Microscope. Clinical&Lab Platform

Similar documents
How To Use An Asbestos Microscope

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

ISO9001 ISO Environmentally-friendly product All optical components in CX41 microscope use lead-free eco-glass.

MICROSCOPES & REFRACTOMETERS for laboratory, industry and food

euromex microscopen bv The Netherlands page1/16

Compound microscope (Hund)

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Biological Microscope. Biological Microscope ECLIPSE E200

OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE

LABORATORY MICROSCOPEs

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10. Macro View. The first true macro fluorescence imaging system

The Kaps SOM -Series. Stereo Examination Microscopes for ENT Specialists. The variable space-saving system for every ENT practice

Olympus BX51 Microscope & DP70 Digital Camera System

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

THE COMPOUND MICROSCOPE

GLobAL Dental Microscopes. Dentists First Choice

The new standard in research microscopy

Leica MZ125. Modular high-performance stereomicroscope with 12.5:1 zoom

Care and Use of the Compound Microscope

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

Product Range Overview

POLARIZING MICROSCOPE BX51-P BX2 SERIES

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Leica DM500 & DM750. A New Generation s Choice of Innovative Educational Microscopes

SERIE SZR. Stereomicroscopi da laboratorio. 13

microscope OP-Dent-5

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

SLIT LAMP BQ 900 Sophisticated microscopy

EyeMag Medical Loupes from ZEISS Seeing is believing NEW! LED illumination

Leica DM LS2 and DM LB2. Life Science System Microscopes with New Ergonomic Concept

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

The upright transmitted microscope is most suited to our purpose of observing samples of compost, soil and compost tea, etc.

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

Microscopes 2014 Microscopes PB Microscopes 1

Inverted Microscope. Inverted Microscope ECLIPSE TS100

MICROSCOPY MARKETING GUIDE

Powerful Upright Microscope Solutions for Life Science and Clinical Applications

Review: Amscope Metallurgical Trinocular Microscope. Michael Reese Much FRMS EMS Bethlehem, Pennsylvania USA

VICKERS HARDNESS TESTER. HBS HBW Kc

Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03

MICROSCOPE & OPTICAL CATALOG

EXPERIMENT #1: MICROSCOPY

OLYMPUS SYSTEM MICROSCOPE. Model BHT OLYMPUS

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

OLYMPUS STUDENT MICROSCOPES IINSTRUCTION MANUAL I CBA& CBB MODELS

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

Operating Manual. Axiostar plus. Transmitted-Light Microscope

Chapter 12 Filters for FISH Imaging

Swift Optical Catalog. Microscope and Digital Microscopy Solutions

MEASURING QUALITY. SINCE 1796 MICROSCOPES. RELIABLE SOLUTIONS FOR ANY APPLICATION

Rodenstock Photo Optics

Rauserv Steam Sterilizers, Laboratory and Hospital Equipment. Brewery Laboratory Equipment

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Biomedical & X-ray Physics Kjell Carlsson. Light Microscopy. Compendium compiled for course SK2500, Physics of Biomedical Microscopy.

Inspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.

Measuring the Point Spread Function of a Fluorescence Microscope

Leica StereoZoom line. Complete solutions for industry, laboratory and training

TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.

The Sigma DP3 Merrill, the latest in the series of compact cameras incorporating the 46 megapixel Foveon X3 direct image sensor.

Infrared Viewers. Manual

HISTOLOGY LABORATORY. Microscope Orientation and Blood Smear Lab

Optical laser beam scanner lens relay system

LOUPES AND HEADLIGHTS HEADLIGHTS. HEINE Headlights. Type of Light LED LED F.O. Light Intensity (at 250 mm working distance)

Light and its effects

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

HEINE 3S LED HeadLight

Leica M651. Manual surgical microscopes for microsurgical disciplines. Living up to Life

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Firearms & Tool Marks Comparison Microscope. Discovery. Leeds Forensic Systems. Your Forensic Imaging Source

IMPORTANT. 2. Avoid the use of the microscope in direct sunlight, high temperature and humidity, dust and vibration.

Leica DM300 User Manual

OLYMPUS STUDENT MICROSCOPES INSTRUCTIONS ST. HS&HSC MODELS OLYMPUS

Alpy guiding User Guide. Olivier Thizy François Cochard

ADAPTING DIGITAL POINT-AND-SHOOT CAMERAS TO OLYMPUS MICROSCOPES

Forensic Science: The Basics. Microscopy

Endoscope Optics. Chapter Introduction

ST-80 MICROSCOPE With Electronic Eyepiece #6810. User Guide

TABKAM X1 Tablet camera system evolution of video microscope systems

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Information. From the LowVision Specialists. Guidelines for the fitting of telescopic systems

9/16 Optics 1 /11 GEOMETRIC OPTICS

Flat-Field IR Mega-Pixel Lens

Microscopy and Cellular Morphology

Living up to Life. Leica LAS Live Image Builder Dynamic Software for Fast Widefield Imaging and Extended Depth of Focus

Microscopy from the very beginning

Experiment 3 Lenses and Images

Fig.1. The DAWN spacecraft

Profile Projector PH-3500

Transcription:

BA410 Microscope Clinical&Lab Platform

BA410 Clinical&Lab Microscope Platform Motic s premier BA410 is the flagship model of its BA Upright Compound Series, and exhibits Motic s advancing optical development approach in creating this high-end microscope. Designed for multiple disciplines from University through Clinical, Laboratory, and Research applications, the BA410 offers true professional quality with a full complement of accessories, making it a valued addition for any biological application. The BA410, when combined with any Moticam digital camera, also provides a powerful documentation tool for reporting or teaching assignments.

BA410 Clinical&Lab Microscope Platform Microscope Stand Through continuous professional usage, ergonomic functionality is increasing in importance in the design of a quality microscope stand. With this in mind, Motic s BA410 design was formulated around actual user parameters in order to maximize comfort during prolonged usage times. Eyepiece Tubes Eyepieces Designed with a comfortable viewing angle of 30, the standard BA410 eyepiece tubes (binocular and trinocular) offer a 22 mm Field of View (FOV 22). The interpupillary distance can be adjusted in the range of 48-75mm. Aside from the regular Binocular tube, Trinocular photo tubes can be obtained with 3 optical beam splitter options: Standard configuration: 100:0 / 20:80 Recommended for Fluorescence: 100:0 / 0:100 Maximum flexibility: 100:0 / 20:80 / 0:100 Motic s Infinity Corrected CCIS Optical system with a field flatness up to 22mm and the high eye point principle of the BA410 s eyepieces ensure true colour and sharp images, while minimizing eye fatigue and strain. As a standard, diopter adjustment is integrated to assist spectacle wearers and for reticule usage. All standard eyepiece tubes now offer an extended butterfly swivel adjustment to increase the viewing height to accommodate individual user s positioning.

Ergo tube Ergo Plus tube Ergonomic Tubes For prolonged viewing demands, the BA410 offers a complement of ergonomic viewing head options, with a FOV 22 and an interpupillary distance of 55-75mm. Two different ergonomic tubes are available: The Binocular Ergo tube has a variable viewing angle of 4-30. The Binocular Ergo-Plus tube also offers an additional extension movement of 35mm.

Objectives The Motic BA410 offers a new class of EC-H optics that sets the standard in price-performance in optical quality. Multilayer coated glass for enhanced contrast and lead-free manufacturing according to RoHS standards are significant features of this new class of Motic CCIS objectives. With excellent spherical aberration correction to significantly improve each lens field flatness and better resolution, the EC-H optics offer superior colour reproduction and fidelity. Documentation Today, accurate documentation is becoming an increasingly important part in most natural science applications. The combination of the BA410 with a member of the Moticam series of digital cameras delivers excellent live images, which can easily be stored for future usage. All Motic cameras come equipped with software to transform the BA410 into an analysis and documentation station. Illumination The BA410 introduces a new collector lens assembly with a secure, screw-on holder for frequently used daylight or other image enhancement filters - an integral part of any illumination package. The complete inner light path of the microscope has been enlarged to minimize diffraction effects at high illumination apertures. The standard Illumination is a 6V/30W Halogen Koehler system. Interchangeability with a LED module (4500K or 6000K) gives maximum flexibility. Motic offers a complete range of digital cameras starting with a basic resolution of 1.3MP (CMOS), up to the Research grade Moticam Pro Line (CCD) with a maximum of (at the moment) 5MP, including Monochrome and Cooled versions. These Moticam cameras deliver sharp live images with easy post-capture handling.

BA410 with fluorescence package Contrast Techniques Phase Contrast and Darkfield For Phase Contrast and Darkfield, the BA410 offers a slider solution of easy handling for single Phase contrast lenses, using an optional slot condenser for each magnification of 10X, 20X, 40X and 100X in combination with phase slider PH1, PH2 and PH3. The new EC-H Phase lenses give a phase image with improved contrast and flatness. A respective Darkfield slider can be used from 4X to 40X lens magnification (N.A. up to 0.65). As a standard, positive phase contrast lenses are supplied. Negative phase contrast is available on request. For more advanced Phase contrast demands, a turret condenser with phase rings for all objectives, including a DF stop, is also available. Like the slider solution, the turret carries the light rings matching both positive and negative phase lenses. Fluorescence Microscopy The modular concept of the BA410 allows an easy upgrade to an EPI-Fluorescence microscope by using the fluorescence attachment. This device may carry up to 4 filter cubes. A complete range of filter cubes is available, covering all routine applications from UV up to NIR excitation. Supplied with band pass barrier filters, multi colour applications can also be performed. General Specifications Binocular/Trinocular head Siedentopf type, 30 inclined, 360 rotating (light split 100:0/20:80) Interpupillary distance 48-75mm Widefield high eyepoint eyepieces, N-WF10X/22mm, with diopter adjustment on both eyepieces and rubber eyecups Reversed quintuple/sextuple revolving nosepiece CCIS EC-H Plan 4X, 10X, 40X S and 100X S-Oil Coaxial coarse and fine focusing system Hard anodized coated stage with built-in low position coaxial mechanical stage (right hand control) Achromatic swing-out condenser N.A. 0.90/0.13 with iris diaphragm Koehler illumination quartz halogen 6V/30W with external lamp house and intensity control Universal power supply 100-240V Blue filter, immersion oil, power cord, Allen hexagonal key, thumb screw and vinyl dust cover are included

EN ES FR DE IT PT RU Motic Incorporation Limited Copyright 2002-2010. All Rights Reserved. Updated: August 2011 Motic is a certified ISO9001, ISO14001 and ISO13485 company. Designed in Barcelona (Spain) www.motic.com Canada China Germany Spain USA