Wireless controls Individual room temperature control for surface heating and cooling systems

Similar documents
HERZ-Thermal Actuators

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Heating Controller. Building Technologies HVAC Products

Drayton Digistat +2RF/+3RF

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RF 1. Contents: Connecting diagram. Detailed information:

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

RRV934. Multi-controller. Synco living

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

ABB i-bus KNX Fan Coil Controller FC/S 1.1

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Controls for fan coil units and cassettes

Thermostats. Technical information

FT-100 Fire Training Fog Machine User Manual English

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

OZW30. Central Unit SYNERGYR

User and installation manual

SMART COMFORT & EASY EFFICIENCY HEATING CONTROLS

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

EK908FHL - Thermostat for floor heating

Electronic Control Devices The European Product Catalogue 2007

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Electric Rotary Actuator - On/Off or programmable control actuator

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Data Sheet. Electro-mechanical counters Hengstler 800 series

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Adjustable room thermostat for heating only or cooling only systems

REMOTE CONTROL MANUAL

MasterINTERFACE 39 Series - Relay interface modules

Safety technique. Emergency stop module BO 5988 safemaster

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Wireless 7 Day Programmable Room Thermostat

ELECTRIC CENTRAL HEATING FLOW BOILER

Voltage Regulator SPAU 341 C. Product Guide

Air conditioning, electrical testing

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

ABB i-bus KNX SA/S Switch Actuators Product Manual

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

IN-OUT Thermometer with Cable Free Sensor and Clock

Inwall Room Temperature Unit

User Manual of WT 493

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

1 Technical Description Lokal-200PC

Quick Connect. quick - simple - efficient.

ABB i-bus EIB Logic Module LM/S 1.1

HCE80/HCC80/HCE80R/HCC80R

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS

How To Use A Power Supply On A Powerline 2.2 (Ai)

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

3466 Building Energy Management Training Systems

GB/DAS User Instruction

Drayton Digistat +2RF

Honeywell, Kieback & Peter, Sauter, Siemens, etc. DynaTemp. Interface (BACnet/IP) Central individual room temperature control.

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

TIG INVERTER INSTRUCTION MANUAL

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

LCD Display. Function keys. Stand. Adapter socket

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

HVAC and Lighting Control Products for Open Building Automation Systems

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Please refer to the chapters below for detailed information about all aspects of the products usage.

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Product and functional description

SYSTEM 45. C R H Electronics Design

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

ATS-505. GB Version 1

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

STERILIZERS, LABORATORY DRYING OVENS

MasterINTERFACE 39 Series - Relay interface modules

Installation & User Instructions

Preset Counter signo 721

User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

Programming Logic controllers

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

Product Name LED Panel light Product Models

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

T5000 T000 LCD Digital Fan Coil Thermostat

SYSTEM 4C. C R H Electronics Design

mecotron Safety relay ESTOP-2 For emergency stop monitoring

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Transcription:

Technical information Application: The range of Oventrop wireless controls includes a room thermostat and a room thermostat-clock with wireless transmitter, wireless receivers with 1, 4 and 6 channels as well as a wireless receiver with time switch for 8 channels. On the one hand, the wireless controls are suitable for use in surface cooling systems and on the other hand they are part of the Oventrop Cofloor surface heating system. Combined with a wireless receiver, electrothermal two point actuators and stainless steel distributors/collectors Multidis SF, the room thermostat with wireless transmitter serve the individual room temperature control of hot water surface heating and cooling systems. As no cabling between the room thermostats and the receiver block is required, existing systems may subsequently be equipped with the radio control. Other applications are wall heating systems and radiant ceiling panels in which the flow rates are regulated at a distributor/collector with actuators. Tender specifications: Room thermostat with wireless transmitter, including 2 batteries, 1.5 V each (round cells, alkaline, type LR03 or AAA) Operating current: 3 V Batteries life span: about 3 years Transmitter frequency: 868.95 MHz Transmitting power: about 10 mw Transmission interval: 10 min. Radio range: 100 m of open air or 1 ceiling and 2 or 3 walls Types of operation: automatic operation, permanent comfort temperature, permanent temperature setback, controller inactive heating or cooling, convertible Timer function: 1 to 15 h, in steps of 1 h Light: function display for adaptation mode, timer, battery replacement, reset Temperature range: 5 C up to 30 C, setting by turning the rotary knob Limitation of nominal value: concealed inside the control knob Temperature setback/ increase: 2 K or 4 K, convertible Regulation behaviour: pulse-width-modulation (PWM, preset) or two point, convertible Hysteresis PWM: about ± 5 K Hysteresis two point: about ± 1 K Valve protection function: switched on for 3 min. every 24 h, can be switched off Operating temperature: -25 C up to +40 C Storage temperature: -25 C up to +70 C Protection: IP 30 (condensation not allowed) Wall attachment: e.g. on flush socket, base: black Item no.: 1150551 System illustration 2014 Oventrop 1

Room thermostat-clock with wireless transmitter: including 2 batteries, 1.5 V each (round cells, alkaline, type LR6 or AA) Power supply: 2 x AA 1.5 V alkaline batteries Operating current: 3 V Batteries life span: about 2 years Temperature range: 5 C up to 32 C Transmitter frequency: 868.95 MHz Transmission interval: 10 min. Radio range: 100 m of open air or 1 ceiling or 3 walls Types of operation: automatic operation (choice of 3 preset programmes with up to 6 switching times per day and individual temperature setting), holiday function, party function, manual operation, inactivate thermostat Operation: via 4 setting keys LDC display: room temperature or nominal temperature, time, weekday, type of operation, switching times heating or cooling, self-learning heating curve Regulation behaviour: pulse-width-modulation (PWM) or two point, convertible Operating temperature: 0 C up to 40 C Storage temperature: -20 C up to +85 C Ambient humidity: operation and storage 45% up to 93% (without condensation) Protection: IP 30 Item no.: 1150553 74 74 Dimensions room thermostat with wireless transmitter 137 96.5 Dimensions room thermostat-clock with wireless transmitter Wireless receiver, 1 channel: Operating current: 230 V Power consumption: < 1.5 W Load circuit: relay, 1 closing contact volt free, AC 24 250 V max. 16 A cos = 1 max. 12 A cos = 0.6 Number of actuators: (electrothermal, 3 W) 230 V: max. of 20 24 V: max. of 28 Received frequency: Key button: 868.95 MHz heating or cooling, convertible, valve test function, master/slave function, pump logic function 1 for adaptation 1 for reset function Indicator lights: 1 Operating temperature: 0 C up to 40 C Protection: IP 30 Wall attachment: e.g. on flush socket Item no.: 1150560 oventrop 75 Reset! Dimensions wireless receiver, 1 channel 75 2 2014 Oventrop

Wireless receiver, 4 channels/6 channels: ready for plug-in Operating current: 230 V Power consumption: 3 VA Load circuits: 4/6 change-over contacts AC 24-230 V, volt free 8 A cos = 1. 2 A cos = 0.6 Number of actuators: (electrothermal, 3 W each) 230 V: max. of 10 per contact 24 V: max. of 14 per contact Received frequency: 868.95 MHz heating or cooling, convertible, valve test function, time switch signals on channel 1 can be used as master for channels 2 to 4/6, channel 4/6 can be used as pump logic Key buttons: 4/6 for adaptation 1 for reset function Indicator lights: 4/6 for adaptation 1 for operating current Operating temperature: 0 C up to 50 C Protection: IP 40 Wall attachment: e.g. on top rail Item no.: 1150561 (4 channels) Item no.: 1150562 (6 channels) 374 Dimensions wireless receiver, 4 channels 454 Dimensions wireless receiver, 6 channels 310 95 57 57 Wireless receiver with time switch, 8 channels: ready for plug-in Operating current: 230 V 50 Hz Power consumption: 4 VA Fuse: 4 A time-lag Loading circuits: 7 contacts sum of all currents 2 A Channel 8 pump logic: 1 contact, volt free, 4 (2) A the pump must not be supplied by the device Number of actuators: 3 W per channel, max. of 10, a max. of 15 actuators can be connected to one device (fuse) Received frequency: 868.95 MHz Indicator lights: preset clock, programming of the clock and adaptation of the transmitter after having removed the cover, heating/ cooling convertible via external signal, pump logic, valve test function, valve protection, deactivation of cooling via external signal in case of condensation 8 for adaptation 1 for operating current about 4 years Batteries life span: Operating temperature: 0 C up to 50 C (without condensation) Protection: IP 40 / shockproof Wall attachment: on top rail Colour of casing: white Item no.: 1150563 Dimensions wireless receiver with time switch, 8 channels 2014 Oventrop 3

Function: The room thermostats and room thermostats-clocks with wireless transmitter detect the temperature, compare the nominal and actual temperature and transmit the information required for the drive of the actuators to the wireless receiver. To guarantee an optimum temperature control, the short-time transmission of the information at intervals of 10 minutes is sufficient and also environmentally friendly. The wireless receiver converts the information of the transmitter into control signals for the electrothermal two point actuators which serve to control the flow rates of the individual heating and cooling circuits. The room thermostat with wireless transmitter, item no. 1150551, is easy to use. Temperature is set by turning the rotary knob, the type of operation is chosen via a switch. During automatic operation, the switching times for comfort temperature and temperature setback are specified by an external time switch, for instance by the room thermostat-clock with wireless transmitter, item no. 1150553. The room thermostat supports two control systems: - An almost constant room temperature is achieved with the pulse-width modulation being comparable to a constant control. - The two point control is recommended for pump or burner controls if operation shall only be switched when the room temperature is exceeded or not reached. When used for room temperature control, the switching times are more diverging; the temperature of the given value is higher. The functions heating or cooling can be chosen via a concealed switch. The valve protection function avoids blocking of the valves. The actuators are switched on once a day. The room thermostat provides a means to test the function control of the transmitter. To guarantee a perfect regulating function, the room thermostat has to be mounted in such a way that it is not influenced by other heat sources. Beyond the functions of the room thermostat, item no. 1150551, the room thermostat-clock, item no. 1150553, not only allows a comfortable timed room temperature control but also offers extensive programming options for an individual adaptation of the room climate. The menu command on the LCD display and the setting via few a key, allow an easy operation. As standard setting, the room thermostat-clock works with a self-learning heating curve. As a result, room temperature is reached at the set time. The function can be inactivated. The time switch signals can be used for the control of further room thermostats. The wireless receivers with 1, 4 and 6 channels as well as the 8 channel wireless receiver with time switch are the connecting link between the room thermostats and the actuators. A clear allocation between the transmitter and the receiving channel is made with the help of a self-learning addressing (adaptation mode). The wireless receivers offer multiple options regarding control. As for the wireless receivers with 4 or 6 channels, one room thermostat and up to 10 electrothermal actuators 230 V can be allocated to each receiving channel. Alternatively, a maximum of 4 actuators 24 V can be connected. The current supply of 24 V has to be made via a separate power pack. An incoming time switch signal on channel 1 may also control the remaining channels. During automatic operation, one room thermostat-clock and up to 5 room thermostats can thus simultaneously switch between comfort temperature and temperature setback. Channel 4 or 6 can work as pump logic. The pump is switched off if the transmitters connected to the remaining channels do not request more heat. In case of malfunction, an acoustic signal is to be heard. Regarding the wireless receiver with 1 channel, one room thermostat and up to 20 electrothermal actuators 230 V can be allocated to the receiving channel. Alternatively, a maximum of 8 actuators 24 V can be connected. The current supply must also be made via a separate power pack. One room thermostat and up to 10 electrothermal actuators 230 V can be allocated to each receiving channel of the 8 channel wireless receiver with time switch, whereas a maximum of 15 actuators can be connected to it. Several receiving channels can be controlled by one transmitter. 100% 0% On Off Pulse-width-modulation control On Off Actuator Two point control Pulse-pause-ratio Actuator Nominal temperature 10min 10min 10min 10min Nominal temperature Nominal temperature Temperature Time t 4 2014 Oventrop

The integrated 8 channel time switch allows a timed temperature control. Programming of the time switch and adaptation of the transmitter can only be carried out after having removed the cover (device must be disconnected from the power supply). Only the room thermostat without clock (item no. 1150551) follows the time profile of the 8 channel wireless receiver. If a room thermostat-clock (item no. 1150553) is teached in, all succeeding channels will follow the time switches of the room thermostat-clock (master-slave). The time switch in the 8 channel wireless receiver will not be taken into account for these channels. Further functions, such as switching from heating to cooling and switching off of cooling in case of condensation are possible via external signals. Installation and fitting: Detailed information regarding the installation and operation of the Oventrop wireless controls can be taken from the enclosed installation and operating instructions. All functions and other applications are also described therein. Examples of installation: System illustration 1 shows a wireless receiver with 4 channels for a surface heating system. The receiver works with a supply voltage of 230 V. The bridges BR4 and BR5 are separated. A voltage of 24 V for corresponding electrothermal actuators is supplied via the terminals 7 and 8. The example shows actuators 24 V open with current off. The model closed with current off is connected to the terminals b and c. A room thermostat-clock is allocated to channel 1 allowing an automatic, timed setback of the room temperature via the room thermostats allocated to channels 2, 3 and 4. System illustration 2 also shows a wireless receiver with 4 channels. The supply voltage for the receiver and the electrothermal actuators ( open with current off ) is 230 V. Room thermostats are allocated to the channels 1, 2 and 3, similar to system illustration 1. Channel 4 controls the circulation pump via the integrated pump logic. If none of the room thermostats requests heat, i.e. all valves close, the pump is switched off. System illustration 3 shows a wireless receiver with 6 channels. The supply voltage for the receiver and the electrothermal actuators ( open with current off ) is 230 V. Room thermostats are allocated to the channels 1, 2, 3 and 4 as in system illustration 1. Channel 5 is controlled by a further room thermostat-clock. This way, the temperature in the associated room can be reduced or increased at different time switches. As in system illustration 2, channel 6 controls the circulation pump via the integrated pump logic. Advantages: - Part of the Oventrop surface heating system Cofloor all components from one supplier - Economic possibilities of subsequent installation of a room temperature control in existing surface heating systems - Time- and cost-saving installation in new systems - Exact room temperature control - High safety against disturbances owing to transmitter frequency 868 and multiple transmission methods - Short-time emitter pulses avoid electric smog - Simple installation and operation - Multiple programming options and special functions - Valve protection function System illustration 1 with connection diagram System illustration 2 with connection diagram OVENTROP GmbH & Co. KG Paul-Oventrop-Straße 1 D-59939 Olsberg Germany Telephone +49(0) 2962 82-0 Fax +49(0) 2962 82-450 E-Mail mail@oventrop.de Internet www.oventrop.de Subject to technical modification without notice. Product range 2 ti 150-0/20/MW Edition 2014 Gedruckt For an auf overview chlorfreiof our global presence visit gebleichtem www.oventrop.de Papier. System illustration 3 with connection diagram 2014 Oventrop 5