HC EXPANSION MODULE. Hydrawise Ready. Quick Start Guide. hunterindustries.com

Similar documents
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Installation Instructions

AMS 120. EFT Guest Card Terminal & Refund unit

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Hollow or Cinder Block Wall Mount Job Aid

CRYPTOPAY QUICK START GUIDE

ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Installation & Operations Manual

Alarm Security Kit - NVR

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

Dell E Series Monitor VESA Mounting Bracket Installation Instructions

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

PROXIMITY CARD READERS C-10, C-20, C60, C70

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business

ipdatatel Wi-Fi BAT Installation and Configuration Guide

iloq P10S.10/20 Programming device User's Guide

Time and Attendance System

Installation GUIDE IMPORTANT: KEEP THIS MANUAL AND THE PRODUCT ID LABEL IN A SAFE PLACE

Before You Begin You must have at least the following: Web Browser Wired Hub/Switch/Router OR Wireless b Router CD-ROM Drive

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

SmartLogger1000. Quick Installation Guide. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.

HMI display Installation Guide

VOYAGER 570G. 744A Sprayer Control

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

DIRECTV Wireless Cinema Connection Kit

How To Wire Wireline Cable To A Cell Phone (New Zealand)

How to Install a Motherboard

LED 18W/12V SWIMMING POOL LIGHT WITH REMOTE CONTROL INSTALLATION AND OPERATING INSTRUCTIONS

Installation Guide for Hive Active Heating

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

GV- RK1352 Card Reader

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

WAVELET WATER QUALITY MONITORING KIT

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Installation Guide Solar Connect-11

Model 201 Wiegand Touchpad Reader Installation Guide

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

Scorpius Installation Guide Version 1.7

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

HEAT PUMP PROGRAMMABLE THERMOSTAT

Precision Clocks When you absolutely can't afford a time shift Installation and Operation Manual

DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Using the enclosed installation diagram, drill three holes in the wall with the lower hole 1150mm from the floor.

Quick Start Guide. Cisco SPA100 Series Analog Telephone Adapters. SPA112 Two Port Phone Adapter SPA122 ATA with Router

FG MOISTURE MONITOR Installation & Operation Manual

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Document number RS-PRD Revision 05 Date 20/10/2009 Page 1/30

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

UV100A Ultraviolet Air Treatment System

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

10/ English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point

ALARM SYSTEM INSTALLATION GUIDE

RM410. Hardware Installation Guide. Quick Start Guide. Rack Mounting Kit. Version 1.00 Edition 1, 12/2012

Quick Start Guide. RV0xx Series Routers

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Step 2. You will see an interface as shown in the diagram below. Please insert your Help Desk username and password.

Cooktop Low-Profile Ventilation Hoods

Install Guide 3M-50. Caution. Caution

BIX Termination Blocks

SELF INSTALLATION GUIDE

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Installation Instructions For Slider Casement Air Conditioners

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

MAGELLAN CONNECTING TO CASH REGISTER EXPRESS

Energy Communication Unit (ECU)

BUILDINGA 1/10 SCALE FLATBED TRAILER

I. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06

1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.

Control Box Wiring For PRSstandard Tool

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

TS1 Ultra Sonic Tank Sender Training. 27 November 2007


How does your heart pump blood in one direction?

Checking the Package Contents. Installing the Printer Software. Connecting. Unpacking the. the Printer. Printer. Attaching

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT

PORTABLE PA SYSTEM #1 LAST UPDATED: FEBRUARY 2011

Powers Controls TH 192 S Single Temperature Room Thermostat

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

AMPSEAL* Automotive Plug Connector and Header Assembly

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Firewall Cover Installation Instruction Sheet

To Install EdiView IP camera utility on Android device, follow the following instructions:

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

FUSION R400 RAID USB 3.0

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Transcription:

HC EXPANSION MODULE Hydrawise Ready Quick Start Guide hunterindustries.com

TABLE OF CONTENTS Installation 3 Hydrawise App Configuration 7 Troubleshooting 8 HC SUPPORT Thank you for purchasing the Hunter HC Expansion Module. In this Quick Start Guide you will learn how to install and configure the HC Expansion Module. For support for Hydrawise cloud software or help with your Hydrawise account, please visit hunter.direct/hchelp. Your expansion module is shipped with A 12 Zone Expansion Module with a blue wiring cover. 36in (900mm) Expansion Cable. Bag containing 2 x screws and 2 x conical wall anchors for wall mounting.

INSTALLATION Expansion Module Location The Hydrawise Expansion Module is designed for installation in a protected location. The chosen location for the expansion module should be within 20in (500mm) of the main controller. Cable Entry The Expansion Module has 2 cable entry options from the rear of the case or via a conduit from the bottom of the Expansion Module. 1. Entry from rear of module- Using a sharp knife, remove the 2 cutouts on the rear of the expansion module as indicated on the diagram as 1. 2. Entry via ¾ inch conduit- Using a sharp knife, cut around the semi-circular line on the expansion module as indicated on diagram as ➋. Cut around the matching line on the blue controller wiring cover. 3

Mounting The Expansion Module 1. Using a drill bit of 3/ 16 inch diameter, drill a hole to a depth of 1 inch (25 mm). 2. Insert plastic anchor so it is flush with the surface of the wall. 3. Screw 1 inch screw into anchor leaving the head protruding about 1/8 inch (4 mm). 4. Slide the controller case over the screw head. 5. Mark second mounting point (see 3 in diagram), remove expansion module, drill hole, insert plastic anchor, slide controller case over first screw head and screw into place. 1 Rear cable entry point (remove with knife) 4 6 7 2 Conduit cable entry point (remove with knife) 3 Wall mounting screw 4 Power indicator 5 Expansion module cable entry 6 Go to previous screen 7 Go to home screen 1 3 4 2 5

Connecting Solenoid Valves Your expansion module has 12 zones. If you have a master valve, it must be connected to the master controller. Refer to your HC Controller Quick start guide or hunter.direct/hchelp for wiring instructions. Connecting The Expansion Module To The Master Controller Power for the Expansion Module is supplied by the master controller via a cable between the units. Note that only the 12 zone controller supports expansion modules. MASTER CONTROLLER EXPANSION MODULE Expansion Module Cable Hydrawise HC HC Expansion module cabl e To other Expansion Modules Expansion Module Cable To Other Expansion Modules 5

Connecting The Expansion Module Power for the Expansion Module is supplied by the master controller via a cable between the units. Note that only the 12 zone controller supports expansion modules. 1. Using the cable supplied, connect the Master Controller and Expansion Module. The Master Controller has a single expansion module port. Each Expansion Module has 2 expander ports. Connect the cable between the port on the Master Controller and the port on the Expansion Module. 2. Once the cable is connected the Expansion Module will power up. 3. Click the blue wiring cover into place to seal the controller and protect the wiring. Note: You must use the Expansion Module cable supplied other cables may damage your controller or Expansion Module. Two Expansion Modules can be daisy chained to create a maximum of 36 zones using the spare Expansion Module port (labeled as ➎ on the diagram) on the Expansion Module. Configure The Expansion Module ID Each Expansion Module must have an Expansion Module ID configured you need to do this only once. You can choose any Expansion Module ID between either 1 and 2 as long as it is unique to your installation. 1. Select the Expansion Module ID by touching the number on the Expansion Module s touch screen. 2. The ID will change to an orange color indicating the configured Expansion Module s ID. When the Expansion Module ID is configured for your controller (see next section) this color will change to green and the status will change to Online to indicate a successful connection between the master controller and the expansion module. 6

HYDRAWISE APP CONFIGURATION Your Hydrawise controller needs to be configured for the new expansion module. Once you have added an expansion module to your controller you will be able to configure extra zones. Log Into Your Hydrawise Account 1. Log into your account as you did when first registering your controller. Add Your Expansion Module To Your Controller s Configuration 2. In the Configuration section, add a new Expansion Module. Give it a name and an ID number between either 1 and 2. This ID number must match the ID you configured on the Expansion Module s touchscreen. Within 60 seconds the Expansion Module ID on the Expansion Module should change to a green color and the status will change to Online to indicate successful configuration. Add New Zones 3. Go to Zones to add your new irrigation zones. You have now successfully finished installation. 7

TROUBLESHOOTING My Expansion Module ID Color Is An Orange Color Check that you have added an expansion module for your controller in the Hydrawise App (see section Hydrawise App Configuration above for instructions). Check that the configured Expansion Module ID on your Expansion Module matches your Hydrawise controller configuration. Check that the master controller is connected to wireless. All Expansion Module ID Colors Are A Grey Color You have not configured an Expansion Module ID on the Expansion Module. Touch either button 1 or 2 on the Expansion Module to set the Expansion Module ID. Expansion Module Zone Not Starting Check that the Expansion Module ID on the Expansion Module is a Green color and the status is Online. If your old controller had a master valve (sometimes referred to as MV) then you must configure a master valve in the app and wire this to a spare zone on the controller. Detailed instructions can be found on the Hydrawise website. Check that your wiring is correct. If no solenoids start then check that your COMMON wire is correctly wired. Find more helpful information on your product? Find tips on installation, controller programming and more... 8 hunter.direct/hchelp LIT-694-QS-EM US 10/16